Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹25.7 L+₹99,710 (4.03%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹36.2 L+₹11.5 L (46.3%)Rejected-AOC THEERTHAM NADUVILEMURI PADANILAM POST NOORANAD ALAPPUZHA DIST KERALA 690529 | ALAPPUZHA | KERALA | 690529 | L3 | Rejected-AOC L3 |
Tender Value
₹37 L
EMD Value
₹74,000
Closing Date
30 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NS KOCHI
Military Engineer Services Garrison Engineer (Naval Services) Kataribagh, Naval Base Post
REPAIR/MAINTENANCE/SERVICING OF AUTOMATIC POWER FACTOR CORRECTION PANELS, FIXED CAPACITOR PANELS AND ALLIED ELECTRIC WORKS IN KATARIBAGH, NAY,GARUDA AREA AND NAVAL BASE KOCHI
2022_MES_541772_2
8943/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Kochi
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NS KOCHI
₹74,000
Yes
22 Oct 2022
16 Aug 2022
1 Sept 2022
16 Aug 2022
30 Aug 2022
17 Aug 2022
Amount
Servicing of Automatic Power Factor Correction (APFC) panel monthly of the capacity 100 kVAr complete comprising any type capacitors, APFC relay, MCCB, Cooling fan, Voltmeter, Ammeter, CTs with all other connected accessories, checking of serviceability of each component, cleaning all contact points, tightening of all connections including replacement of unserviceable components, thimbles, nut bolt and washers, etc if necessary, cleaning the entire panel by using hot blower complete all as directed by Engineer-in-Charge.
All as per item No.1 above but capacity 125 kVAr
All as per item No.1 above but capacity 250 kVAr
All as per item No.1 above but capacity 300 kVAr
All as per item No.1 above but capacity 375 kVAr
All as per item No.1 above but capacity 500 kVAr
Note for item No 1 to 6. (i) The above quoted rates are inclusive of the cost of replacement of nut, bolt & washers, thimbles and control fuses and fuse folders used while servicing the APFC panels or in any working time as directed by the Engineer-in-charge. (ii) The rent of the tools using shall deemed to be include in the above quoted rate. (iii) Spares for unserviceable components to be replaced shall be measured and paid separately. (iv) If the contractor is failed to carry out the monthly servicing of the panel, a penalty of double the quoted rate will be recovered. (v) Contractor shall be ensure the APFC panel functional throughout the contract period and power factor reading shall not be fall under 0.95 PF. (vi) If any APFC panel found not functional or the power factor falls to 0.94 or low PF, a penal recovery of Rs.500.00 per day shall be recovered in this connection Accepting officer's decision is final. (vii) Contractor shall be submitted a monthly maintenance programme with location to the Engineer-in-charge and the maintenance shall be carried put in the presence of JE/Engineer-in-Charge without fail.
Supply only Heavy duty capacitors 3 to 25 kVAr, voltage 440 volt, 3 Phase, cylindrical, having operating losses 0.35 W/kVAr.
Supply only APFC relay, 4 Stage, auto set function, having digital display.
Supply only APFC relay, 6 Stage, auto set function, having digital display.
Supply only APFC relay, 8 Stage, auto set function, having digital display.
Supply only APFC relay, 12 Stage, auto set function, having digital display.
Supply only thyristor switching module, 440 volt, 50 Hz, having high peaking inverse voltage of 2.2 kV suitable for 10 kVAr.
Supply only thyristor switching module, 440 volt, 50 Hz, having high peaking inverse voltage of 2.2 kV suitable for 25 kVAr.
Supply only thyristor switching module, 440 volt, 50 Hz, having high peaking inverse voltage of 2.2 kV suitable for 50 kVAr.
Supply only capacitor duty contactor, 415 volt, 3 phase,50 Hz, 1 NO, suitable for kVAr rating up to 5 kVAr.
Supply only capacitor duty contactor, 415 volt, 3 phase,50 Hz, 1 NO, suitable for kVAr rating up to 12.5 kVAr.
Supply only capacitor duty contactor, 415 volt, 3 phase,50 Hz, 1 NO, suitable for kVAr rating up to 15 kVAr.
Supply only capacitor duty contactor, 415 volt, 3 phase,50 Hz, 1 NO, suitable for kVAr rating up to 20 kVAr.
Supply only capacitor duty contactor, 415 volt, 3 phase,50 Hz, 1 NO, suitable for kVAr rating up to 25 kVAr.
Supply only capacitor duty contactor, 415 volt, 3 phase,50 Hz, 1 NO, suitable for kVAr rating up to 50 kVAr.
Supply only 3 pole contactor 70 amp, type MNX 70,415 volt,3 phase, 50 Hz, 2 NO+2NC.
Supply only 3 pole contactor 110 amp, type MNX 110,415 volt,3 phase, 50 Hz, 2 NO+2NC.
Supply only 3 pole contactor 140 amp, type MNX 140,415 volt,3 phase,50 Hz, 2 NO+2NC.
Supply only electronic time switch.
Supply only side mounting Add-on block on auxiliary contact block suitable for MOC, 1NO+1NC.
Supply only HRC fuse, DIN type fuse links, 250 Amps.
Supply only HRC fuse, DIN type fuse links, 160 Amps.
Supply only HRC fuse, DIN type fuse links, 125 Amps.
Supply only HRC fuse, DIN type fuse links, 80 Amps.
Supply only LED indicator lamp (RED, YELLOW, GREEN).
Supply only LED indicator lamp (AMBER, BLUE).
Supply only push button actuator with carrier any colour.
Supply only PVC Cooling fan for APFC panel 6” sweep as per sample.
Supply only VAF+PF meter, accuracy 1.0, 5 Amp, flush mounting 96 x 96 mm, 80-300V AC, 3 phase.
Material & Labour for painting to APFC panel with two coat of synthetic enamel paint by using spray paint after isolating the electric supply then thoroughly cleaning the surface to remove dirt, grease, oil stains and preparation of old painted surfaces, etc and making the surface ready to paint including re-connection of electric supply all as specified and directed by Engineer-in-Charge
Supply only capacitor duty contactor, 415 volt, 3 phase, 50 Hz, 1 NO, suitable for kVAr rating up to 10 kVAr.
Supply and fix in repair MCCB, Three pole 630 Amps with adjustable thermal release having breaking capacity 36 KA complete all as specified and directed.
Supply and fix in repair MCCB, Three pole, 400 Amps with adjustable thermal release, having breaking capacity 36 KA complete all as specified and directed.
Supply and fix in repair MCCB, Three pole, 250 Amps with adjustable thermal release, having breaking capacity 25 KA complete all as specified and directed.
Supply and fix in repair MCCB, Three pole, 200 Amps with adjustable thermal release having breaking capacity 25 KA complete all as specified and directed.
Supply and fix in repair MCCB, Three pole,160 Amps with adjustable thermal release , having breaking capacity 25 KA complete all as specified and directed.
Supply and fix in repair MCCB, Three pole, 125 Amps with adjustable thermal release, having breaking capacity 25 KA complete all as specified and directed.
Supply and fix in repair MCCB, Three pole, 63/100 Amps with adjustable thermal release, having breaking capacity 25 KA complete all as specified and directed.
Supply and fix Control wiring using 1.5 Sqmm 1100 volts FRLSH PVC insulated industrial grade copper conductor single core unsheathed cable complete all as specified.
Supply and fix Control wiring using 2.5 Sqmm 1100 volts FRLSH PVC insulated industrial grade copper conductor single core unsheathed cable complete all as specified.
Supply only HRC DIN type fuse base 250 Amps.
Supply and Fix MCB SP 6 to 32 Amp 'C' curve, 230 volt AC.
Supply and Fix MCB DP 6 to 32 Amp 'C' curve, 230 volt AC.
Supply and Fix MNX 9 three pole power contactor of AC 415 Volts 3 phase.
Supply only HRC DIN type fuse base, 160 Amps.
Supply and Fix MCB TP 6 to 32 Amp 'C' curve, 230 volt AC.
Supply and Fix control relay MXO 40E (4 NO) AC 415 Volt 4 Amp
Supply and Fix MCB FP 40 to 63 Amp 'C' curve, 230 volt AC.
Material and Labour for earthing as in repair complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, buried directly and preferably vertically in ground, earth pit not less than 2.25 Metre deep below ground level with top edge of the plate not less than 1.5 Metre below ground level connected with galvanised strip of 32x6 mm by means of nuts, bolts, check nuts and washers made of galvanised iron including welding all joints or steel earthing lead to be protected by galvanised iron pipe 40mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compact thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20 mm graded stone aggregate), 50mm thick precast RCC (1:2:4) cover slab (reinforced with 8mm dia TMT bar @ 15cm C/C both ways and suitable handle made of 10mm dia) including necessary earthwork in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50m etc all as shown in electrical plate No.3 of MES SSR Part I (2009) complete including testing on completion all as specified and directed by Engineer-in-Charge.
Material and Labour as in repair for earth continuity conductor or main earthing strip fixed to wall or recess or chases or buried in ground including drawn in GI pipe 40mm or any other indicated situation etc as required using galvanised iron strip of size 32x6 mm, all joints shall be properly welded complete all as specified and directed.
Supply only MPP heavy duty capacitors 5 to 15 kVAr, 440 volt, 3 phase, box type; resin filled having operating losses 0.35 W/kVAr, complete all as specified.
Supply only MPP heavy duty capacitors 20 to 50 kVAr, 440 volt, 3 phase, box type, resin filled having operating losses 0.35 W/kVAr, complete all as specified.
Shifting of APFC panels/LT panels of any capacity from one substation to another substation in side Naval Base and Kataribagh by using necessary vehicle, crane, men power etc complete all as specified and directed. Notes :- (i) Contractor shall take care of the equipment while shifting, if any damage found shall be rectified at his own risk. (ii) The labour charge for disconnecting/ connecting electrically and mechanically shall deem to be included in the above rate.
Servicing of LT fixed capacitor panel of any capacity by replacing unserviceable capacitor, MCCB, checking of each component, tightening of all connections, including replacement of unserviceable parts, thimbles, nut bolt and washers etc if necessary, cleaning the entire panel by using hot blower complete all as directed by Engineer-in-Charge. Note: - MCCB, MCB, capacitor if any replaced shall be measured and paid separately.
Supply and fix in replacement of fibre glass insulated flexible copper cable duly varnished class 'F' single core size 25 Sqmm
Supply and fixing in replacement flexible copper cable, multi stranded of size 2 core, 2.5 Sqmm, 1100 volt grade as per IS 694 : 1990, complete with including necessary tags, clips, etc complete all as specified and directed
Supply, laying in replacement and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with stranded aluminium conductors, 1100 volts grade of size 185 Sqmm 3.5 core all as specified and directed by Engineer-in-Charge
Supply, laying in replacement and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with stranded aluminium conductors, 1100 volts grade of size 240 Sqmm 3.5 core all as specified and directed by Engineer-in-Charge
Supply, laying in replacement and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with stranded aluminium conductors, 1100 volts grade of size 300 Sqmm 3.5 core all as specified and directed by Engineer-in-Charge
Supply and Fix control relay MXO 22E (2 NO + 2 NC) AC 415 Volt 4 Amp.
Supply, install in repair, testing and commissioning of indoor panel with angle iron of size 40 mm x 40 mm and thickness 5 mm suitable for APFC 150 kVAR, 6 step (2X5+3x25+1x50) (One 15 kVAR capacitor should be directly connected) IP42 protection, auto switching, indoor, bottom cable entry floor mounted including Phase indicating lamp = 01 Set, and Digital VAF meter = 01 No and all necessary control wiring with space for Heavy duty MPP capacitor non compartmentalised, space for suitable APFC relay and space for MCCBs and capacitor duty contactors, The Panel shall be made up of CRCA steel sheet , 2 mm thickness, powder coated as per RAL 7032 with, CTs, digital meters, phase indicating lamp, suitable aluminium bus bar with support and provision for cooling fan,complete all as specified and directed. Note: MCCBs, APFC relay, capacitors, Contactors, timers and cooling fans will be paid separately.
Supply and fixing CT 1000/5 Amp, insulated, class 1.0.
Supply and fixing CT 800/5 Amp, insulated, class 1.0.
Supply and fixing CT 500/5 Amp, insulated, class 1.0.
Supply and fixing CT 400/5 Amp, insulated, class 1.0.
Supply and fixing CT 200/5 Amp, insulated, class 1.0.
Supply and fixing CT 100/5 Amp, insulated, class 1.0.
Dismantling the existing HT three panel VCB after taking proper shutdown at 'H' substation inside Garuda by disconnecting all HT cables for raising the HT panel to avoid water ingress by providing angle iron platform of height 1.5 feet with suitable load carrying capacity and to provide block masonry with finish for racking out and placing VCB truck and reconnecting all HT cables all as specified and directed by Engineer in charge.
Supply and fix in replacement fibre glass insulated flexible copper cable duly varnished class 'F' single core size 4 sqmm
Amount of Credit Schedule shall be deducted to arrive the Contract Sum.
PHEJAYS AGENCIES
Green Ray Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .