Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.2 LAccepted-AOC GANDHI CHOWK SHIV MANDIR MARG RANIKHET DISTT ALMORA UTTARAKHAND | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹20.6 L+₹2.3 L (12.3%)Rejected-Finance | L2 | Rejected-Finance Not being lowest tenderer |
Tender Value
₹23 L
EMD Value
₹46,000
Closing Date
15 Jun 2022, 6:00 pmClosed
GE Ranikhet
GE MES Ranikhet
PETTY REPAIR AND DAY TO DAY MAINT WORKS OF INTERNAL EXTERNAL ELECTRIFICATION AT RANIKHET CHAUBATTIA ALMORA NAINITAL AND KAUSANI UNDER GE RANIKHET
2022_MES_523083_1
GE/RKT/17 of 2022-23
Open Tender
Civil Works
Works
335 days
Ranikhet Chaubattia Almora Nainital Kausani
As per NIT
6 documents required · 6 mandatory
₹500
GE Ranikhet
₹46,000
Yes
5 Jul 2022
10 May 2022
17 Jun 2022
10 May 2022
15 Jun 2022
25 May 2022
Amount
BOQ ( SCH 'A') Attending of day to day complaints, petty repair wks of E/M nature pertains to internal electrification/External electrification/ internal electric wiring, comprise of checking of existing electrical circuits / items i.e. various lighting luminaries, appliances, exhaust fan,switch/socket & other accessories, DB / MCCB incomer, MCB / MCCB etc for continuous electrical supply;checking of LT/HT overhead/underground electric lines with necessery excavation/ refilling in any type of soil as requied, checking of LT Panels for detection of nature of fault / defect; carrying out minor repairs etc as required to make the items functional or to restore electric supply with and incl tightening of loose/broken connections/ overhead/underground electric lines, insulating the naked wire, opening of bakelite sheet/cover plates/DB etc and refixng the same after necessary repairs, checking of street/security lights by taking down and refixing the same after necessary repair, replacing defective items provided under relevant item(s) here-in-after with and incl petty repairs items/materials i.e. fuses, thimbles (upto 10 sqmm single core wire), small wires of any size and description upto 1.5 m, lugs, screw, washer, nut bolts etc with and incl cutting of bakelite sheet for fixing of accessories, making all electric connection etc, in Md/OTM Accn and in any location within the area of Ranikhet Cantt (Half Moon, Alma,S&T, Butchry,Adm top, DHQ, MH area, Jhula Devi area,Ranijheel, Dulikhet, walna range, Majhkhali and Ghingharikhal area) and, by deploying sufficient number of qualified electricians & helpers alongwith suitable T&P, safety equipment & other necessary devices, every day including Sunday and Holiday, during time from 8:00 AM to 04:00 PM, complete all as specified and directed.
Note for item No 01 to 05 : (a) All the complaint(s) received will be lodged & rectified by the contractor rep and will have to maintain a proper record as directed in complaint register and in complaint slip. (b) Complaint slip and complaint register will be provided by the contractor without any extra charge. (c) Complaint register will be produced on daily basis to JE and Engr-in-charge (d) If contractor or his tradesmen fails to attend and rectify the complaint(s), as described earlier, on same day or any stipulated time given by the JE/Engineer-in-charge, the penal recovery / penalty of Rs. 200.00 (Rupees Two Hundred only) per complaint per day for first day and after that Rs. 500.00 (Rupees Five Hundred only) per complaint per day shall be recovered from the contractor’s dues.
(e) Contractor shall provide and deploy adequate experienced professional to carry out day to day complaints and tradesman will remain present in Ranikhet area in one shift from 0800Hrs to 1600 Hrs from Monday to Saturday. For Ranikhet one electrician and one helper will be provided by the contractor per day. For Chaubattia, Almora, Kausani and Nainital Station one Electrician will be provided by the contractor per day for each ibid station. In case of any breakdown/ emergency, contractor shall make arrangement to attend and rectify the complaints in odd hours on sunday/ holiday also. The rates quoted in BOQ under respective items shall be deemed to be included the same and nothing extra shall be admissible on this account. (f) Whatever shall be the nature of electrcal complaint, the wholesole rectification responsibilty lies with the contractor.
(g) The quoted rate are deemed to be inclusive of petty repairs items/materials i.e. fuses, small wires single / twin / three core up to 1.0 sqmm, MCB connecting links, DIN rails, screws, nuts, bolts & washers, aluminium / copper lugs / thimbles, insulation tape, CTC and cotton waste for cleaning burnt area etc as required at site, during execution of petty repair wks or attending complaints. Nothing extra shall be admissible on this account at any stage.
(h) Any major items/materials which are required to be replaced with new one i.e. switch, socket, bell push, lamp holder, ceiling rose, fan regulator, modular accessories, ballast / chock, lamp, bakelite sheet, MCCB, MCB, casing & caping, plug top, light luminaries, PVC box, conduits etc shall be mesaured & paid separately under respective item(s) as supply only and labour charges of same shall deemed to be included in unit rate against item No 01 of Sch 'A' BOQ by the contractor.
(j) Quoted rate shall deemed to be inclusive of cutting chases for concealed conduit and insertion of metal boxes in the wall wherever required and making good of disturbed wall surfaces with cement plaster, putty and OBD etc to match with the existing surfaces and nothing extra shall be admissible on this account.
(k) The cost of transportation (to and fro) and other necessary T&P (i.e. screw driver set each sizes, line tester, combination and cutting pliers, cutting knife, hand gloves suitable for available voltages, Test lamp with conductor and holder etc), equipment and safety gear shall be arranged / brought by contractor to complete the job and nothing extra shall be paid to the contractor in this effect. (l) Old unserviceable materials retrieved during rectification of complaints/defects shall be the property of the contractor and necessary credits for the same shall be charged/recovered from the contractor as per sch of credit from his dues/RAR/Final bill as the case may be and no any claim on this account/quality/condition/quantum of material retrieved shall be admissibble and nothing extra shall be paid for the same by the Govt.
All as per item No 1 above but for Chaubattia Cantt Area including Highest Point and Nagpani area
All as per item No 1 above but for Almora Cantt Area
All as per item No 1 above but for Kausani Cantt Area
All as per item No 1 above but for Nainital Cantt Area
Supply only call bell ding dong AC, 230V single pole complete all as specified and directed.
Supply only bell push piano flush type single pole, one way 5 Amp complete all as specified and directed.
Supply only MCB single pole, 240 volts, 5 to 32 Ampere, rupturing capacity 10 KA, ‘B’ curve type including taking down complete all as specified and directed.
Supply only MCB single pole and neutral, 240 volts, 25-32 Ampere, rupturing capacity 10 KA, 'B’ curve type including taking down complete all as specified and directed.
Supply only MCB tripal pole and neutral, 415 volts, AC, 63 to 100 Ampere, rupturing capacity 10 KA, ‘B’ curve type complete all as specified and directed.
Supply only service connection cable, 1100 volts grade heavy duty PVC insulated aluminium conductor, 16 Sqmm 2 core size, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular, complete all as specified and directed.
Supply only High quility LED lighting fixture mirror type with high output diffuser 2 feet 1x5 Watt, 220V AC, complete with polycarbonate tube, white/warm white suitable for mirror light internally pre wired of 1.5 sqmm three core flexible cable complete all as specified & directed.
Supply only high quality indoor LED PLL base lamp 4 pin, 18 Watt (with inbuiled driver) complete all as specified and directed.
Supply only High quility LED T8 tube rod 20 Watt (with inbuild driver) with single side connection including connection with wire of 1.5 sqmm twin twisted flexible cable complete all as specified & directed.
Supply only switch piano flush type single pole, one way 5/6 Amp complete all as specified and directed.
Supply only socket out let multi 5 pin, 5/6 Amps, flush type complete all as specified and directed.
Supply only switch piano flush type single pole, one way 15 Amp complete all as specified and directed.
Supply only socket out let 2 in 1, 3 pin, 05 and 15 Amp, flush type complete all as specified and directed.
Supply only lamp holder angle type PVC/Polycarbonate type insulated body with back plate suitable for batten/wall fitting complete all as specified and directed.
Supply only modular switch 6/10A , 1 module, one way complete all as specified and directed.
Supply only modular socket out let 6/10 Amps, 2 module 2/3 pin combined complete all as specified and directed.
Supply only modular switch 16/20A , 1 module, one way complete all as specified and directed.
Supply only modular socket out let 16/20 Amps, 2 module, 2/3 pin combined complete all as specified and directed.
Supply only shackle type insulator, porcelain, vitreous, white, brown or green insulator of size 75 mm height and 90 mm dia for working pressure of 1100 volts, LT complete with galvanised mild steel strap of size 31 X 3 mm / flat iron 50 X 6 mm ‘D’ clamp or ‘U’ clamp of suitable size and holding clamp, washers, insulator bolts of 12 mm dia, washers and nuts complete all as specified and directed.
Supply only MCCB of Cap 350 Amp, 4 pole, 36 KA, with adjustable thermal release and earth fault protection, 415 volt grade including cutting and welding work for fixing of MCCB in existing panels any type and model complete all as specified and directed..
Supply only MCCB of Cap 200 Amp, 4 pole, 36 KA, with adjustable thermal release and earth fault protection, 415 volt grade including cutting and welding work for fixing of MCCB in existing panels any type and model complete all as specified and directed..
Supply only MCCB of Cap 100 Amp, 4 pole, 25 KA, with adjustable thermal release and earth fault protection, 415 volt grade including cutting and welding work for fixing of MCCB in existing panels any type and model omplete all as specified and directed..
AJA BUILDERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .