| 1 | L1₹14.4 LAccepted-AOC H NO 199 W NO 6 NEAR OLD SDM OFFICE DISTT HAMIRPUR HP 177001 | HAMIRPUR | HAMIRPUR | HP | 177001 | L1 | Accepted-AOC Awarded to lowest bidder | |
| 2 | L2₹12.8 L+₹1.0 L (8.55%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹15.9 L+₹4.1 L (34.6%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | Rejected-Technical | - | Rejected-Technical Technically Not Qualified |
| Sl No | Description | Qty | Unit | SHARMA ELECTRICAL CO. L1 | pankaj saini L2 | JAMWAL ELECTRICAL WORKS L3 |
|---|---|---|---|---|---|---|
| 1.00Supplying, Installation , testing and commissioning of 40KVA/ 40KW True Online , DSP Controlled online UPS in with 3 phase AC input (Input Voltage Range 320V to 480V, 50Hz ) and 3 phase AC output 380/400/415V +/- 1%, 50+/-0.5HZ with 30 minutes backup with 12V SMF batteries Bank with open Rack along with inter connecting battery cables and DC cable from UPS to Battery bank ( min. VAH required for battery Bank =34000 VAH ) ,The UPS should be with IGBT Based Rectifier and Inverter both and with touch screen LCD/LED display for monitoring of its status along with same OEM Make inbuilt /external Galvanic Isolation Transformer at input side only .UPS should have EPO & cold start feature ,input phase sequence protection as well as correction with manual & automatic bypass inbuilt & dust filters also. | ||||||
| 1.01Technology | ||||||
| 1.02True Online Double Conversion with IGBT Based Rectifier & IGBT Based Inverter | ||||||
| 1.03INPUT | ||||||
| 1.04Input Voltage window 320 VAC - 480 VAC | ||||||
| 1.05Input Frequency window 45-65 Hz (Autosensing) | ||||||
| 1.06Nominal Frequency 50 Hz | ||||||
| 1.07Total Harmonic Current Distortion (THDI ) should be less than 5 % at full rated load | ||||||
| 1.08Input power factor (pf) greater than or equal to 0.99 | ||||||
| 1.09UPS should have input phase sequence protection as well as correction feature,EPO & cold start feature & with manual & automatic bypass inbuilt & dust filters . | ||||||
Tender Value
₹14.4 L
EMD Value
₹28,900
Closing Date
1 Aug 2022, 10:00 amClosed
Executive Engineer
Electrical Division HPPWD Palampur
Providing, installation, testing and commissioning of 40 KVA and 5 KVA online UPS for the new PSA Oxygen Plant at Civil Hospital Dehra, Tehsil Dehra, Distt. Kangra, HP
2022_PWD_63039_2
Elect. Division HPPWD Palampur
Open Tender
Electrical Works
Item Rate
30 days
Dehra in Distt. Kangra
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
₹28,900
26 Mar 2026
25 Jul 2022
1 Aug 2022
25 Jul 2022
1 Aug 2022
25 Jul 2022
Amount
Supplying, Installation , testing and commissioning of 40KVA/ 40KW True Online , DSP Controlled online UPS in with 3 phase AC input (Input Voltage Range 320V to 480V, 50Hz ) and 3 phase AC output 380/400/415V +/- 1%, 50+/-0.5HZ with 30 minutes backup with 12V SMF batteries Bank with open Rack along with inter connecting battery cables and DC cable from UPS to Battery bank ( min. VAH required for battery Bank =34000 VAH ) ,The UPS should be with IGBT Based Rectifier and Inverter both and with touch screen LCD/LED display for monitoring of its status along with same OEM Make inbuilt /external Galvanic Isolation Transformer at input side only .UPS should have EPO & cold start feature ,input phase sequence protection as well as correction with manual & automatic bypass inbuilt & dust filters also.
Technology
True Online Double Conversion with IGBT Based Rectifier & IGBT Based Inverter
INPUT
Input Voltage window 320 VAC - 480 VAC
Input Frequency window 45-65 Hz (Autosensing)
Nominal Frequency 50 Hz
Total Harmonic Current Distortion (THDI ) should be less than 5 % at full rated load
Input power factor (pf) greater than or equal to 0.99
UPS should have input phase sequence protection as well as correction feature,EPO & cold start feature & with manual & automatic bypass inbuilt & dust filters .
OUTPUT
Output Power Factor should not less than unity.
Output Power Capacity in watts (KW) 40KVA / 40KW
Output Voltage - 380/400 /415 Volts rms, adjustable via the user interface.
Total Harmonic Distortion : < 2% for linear load & <5% for 100% non-linear load
Output Frequency range 50/60 HZ.
UPS overall Efficiency upto 94% (without isolation TX)
Overload Capacity: A) 110% for 60 min, B)10 minutes at a load representing 125% , C) 60 second at a load representing 150%
Parallel option upto 4 Units should be available
Bypass UPS Should Be built in Automatic and Maintenance Bypass
Warranty Terms Two Years on UPS & Batteries with onsite service Support
Operating Temperature 40 degree C
Noise Level Less than 70 dBA
Battery Bank UPS should be with SMF battery bank of minimum VAH of 34000 suitable for 30 minutes backup on load PF of 0.8.
VDC flexibility AT least 4 batteries Flexibility /variable VDC ranges.
Communications Ports USB/ RS232 and SNMP optinal for future upgradation
Protection requried over volatage,short circuit ,overload at UPS O/p and Under Voltage at battery terminal , input phase sequence protection and correction as inbuilt feature .
Certifications & Standard ISO 9001 & 14001 certification ,Design as per IEC standard EN-62040 ,IP20 Protection
Other Features
UPS should have EPO & cold start feature ,input phase sequence protection as well as correction with manual & automatic bypass inbuilt & dust filters also
OEM should have 2-3 own /ASP based service centers in the state for better & timely service support , need to share atleast 2 engineers contact details with service centre address details in the region of installation and OEM Turnover should not be less than 300 Crores/year in last 3 financial years with profitability. 10 years presence of OEM in Govt. project segment And Quoted product should be available on OEM Website with as per asked technical compliance.
Approved Make: APC-Schneider /Emerson -Vertiv /Legrand-Numeric Only
UPS System Description
Supplying, installation,Testing and commissioning of 5KVA/ 4KW True Online , DSP Controlled online UPS with 1 phase AC input and 1 phase AC output with 30 min backup with 12V SMF batteries Bank with Rack ( min. VAH required =4900 VAH) ,The UPS should be with IGBT Based Rectifier and IGBT based Inverter both and with LCD/LED display for monitoring of its status along with same OEM make inbuilt Galvanic Isolation Transformer at input side side only .UPS should have EPO & cold start feature ,input phase sequence protection as well as correction with manual & automatic bypass inbuilt & dust filters also, as required complete in all respects.
Input (Rectifier)
Technology IGBT PWM BASED TECHNOLOGY for Rectifier & Inverter both
Primary source voltage 230 VAC 1 Phase
Input Voltage Range 160-300V AC
Power device IGBT Based Rectifier
Input Frequency 50Hz /60 Hz (Auto Sensing)
Input Frequency Range 45Hz-55Hz /55Hz-65Hz
Galvanic Isolation UPS Should be of same OEM make Inbuilt Galvanic Isolation Transformer at Input side
Input power factor > 0.99
Output (Inverter)
Technology IGBT Based Inverter
DC volts 240/192VDC
Output voltage 220/230/240V AC 1 Phase
Output frequency 50 Hz /60 Hz (+/- 0.1Hz)
Output wave form Pure Sine Wave
Output Power Factor not less than 0.8
Harmonic distortion THD <2% for linear loads, < 5% for non - linear loads.
overall Efficiency upto 92% without Isolation
Crest factor 3:1
Overload up to 110% for 3 Min. , upto 125% for 30 sec
General
LCD Pannel DSP Controlled LCD Pannel
Smart Battery Management Should be inbuilt within the UPS System
Cold Start Feature Cold start feature required as standard in UPS
Back-up 30 min with Min VAH Required -4900 VAH on 12V SMF batteries
Battery Make Exide /Amaron-Quanta/Panasonic Make Only
warranty 2 years on UPS & 2 years on Batteries
LCD Display information Normal Mode/Load on Battery/Load on Bypass/System Fault
Audible Alarm Mains Failure/Low battery /UPS Warning /Overload/Fault & Bypass Mode etc
Communication interface RS232/USB port for software interface and SNMP optional for remote Monitoring
Ambient temperature Standard: 0 - 40 Deg.C
Noice Level <60dB at 1 Meter
Cooling Forced Air
CERTIFICATIONS & Standard ISO 9001 & 14001 & CE, PEP certification ,BIS Certified & ROHS Compliance product
Compatibility DG Set
Preffered/Approved Brand APC /Emerson -Vertiv /Legrand-Numeric
Supplying, erection, testing & commissioning of VRLA-AGM maintenance free Battery 12V=16 Nos. 26AH extra lead acid battery with thicker tubes suitable for UPS as required complete in all respects and to the best satisfaction of Engineer-in-Charge
Makes: Exide Power Safe/ Quanta 12V SMF Batteries for 30 Minutes backup or any other make approved by Engineer-in-Charge.
Supplying, erection, testing & commissioning of VRLA-AGM maintenance free Battery 12V=38 Nos. 75AH extra lead acid battery with thicker tubes suitable for UPS as required complete in all respects and to the best satisfaction of Engineer-in-Charge.
Makes: Exide Power Safe/ Quanta 12V SMF Batteries for 30 Minutes backup or any other make approved by Engineer-in-Charge
Providing and fixing Enclosure for MCCB as required complete in all respects and to the best satisfaction of Engineer-in-Charge.
Makes: L&T( Cat No.CM90996OOOO),Schinder, Havells.
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.
2x2.5 Sq. mm. Make: SCI/Polycab/Havells
Providing and fixing following rating and breaking capacity MCCB in the existing cubical panel board including drilling holes in the cubicle panel, making connections, etc. as required.
100 Amp. -16 KA
Makes:-L&T/Legrand/Schneider.
Supplying and fixing 20 Amps, 240 volts, SPN industrial socket outlet, 2-pole & earth, metal enclosed plug top, sheet steel enclosure, suitable to accommodate a 20 Amp SPN-MCB/DP, on surface or in recess, with chained metal cover for the socket outlet, complete with connections, testing and commissioning etc. as required.
Makes:-L&T/Legrand/Schneider.
Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:-
Armoured cable 35 sq. mm (3.5 core)
Makes: KEI, Havells/SCI
pankaj saini
JAMWAL ELECTRICAL WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .