| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.3 LAccepted-AOC GSTIN: 16BEIPP2332F1ZPAMBASSA COLONY P O AMBASSA AMBASSA DHALAI TRIPURA | AMBASSA | DHALAI | TRIPURA | 799289 | ₹4.3 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹4.4 LRejected-Finance NARAYAN PUR DUMBURNAGAR BAC GONDACHERRA DHALAI TRIPURA | GONDACHERRA | DHALAI | TRIPURA | 799284 | ₹4.4 L | L2 | Rejected-Finance Being L2 |
| 3 | L3₹4.5 LRejected-Finance VILL HARINMARA P O KULAI BAZAR AMBASSA DHALAI TRIPURA PIN 799204 | AMBASSA | DHALAI | TRIPURA | 799204 | ₹4.5 L | L3 | Rejected-Finance Being L3 |
| 4 | L4₹4.9 LRejected-Finance BIRGANJ AMARPUR GOMATI DISTRICT TRIPURA 799101 | GOMATI | TRIPURA | 799101 | ₹4.9 L | L4 | Rejected-Finance Being L4 |
| 5 | L5₹5.1 LRejected-Finance GSTIN: 16CVCPB9154P2Z5 | ₹5.1 L | L5 | Rejected-Finance Being L5 |
Tender Value
₹7.4 L
EMD Value
₹14,838
Closing Date
5 Feb 2026, 3:00 pmClosed
Executive Engineer, PWD (WR D-V), Kamalpur
Executive Engineer, PWD (WR D-V), Kamalpur
Renovation of KC Para DC Para Ratan Nagar F1 LI Schemes under WR sub Division Gonda Twisa during the year 2025 26 SH Repairing of UPVC distribution system hydrant points sluice valve chamber Manifold etc.
2026_CEWR_69558_1
39/EE/WR/D-V/KMP/2025-26
Open Tender
Civil Works - Water Works
90 days
Gonda Twisa
Please refer to the tender documents
4 documents required · 4 mandatory
₹1,000
₹14,838
Yes
27 Mar 2026
22 Jan 2026
5 Feb 2026
22 Jan 2026
5 Feb 2026
22 Jan 2026
Excavating trenches of required width for pipes, cables, etc. including excavation for sockets and dressing of sides ramming of bottoms , depth minimum 1.25m including getting out the excavated soil and then returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layers by ramming watering etc. and disposal of surplus excavated soil as directed within a lead of 50 m as per CPWD Specification & direction of Engineer-in-charge. A) All kinds of soil.
a) Pipe , cables etc. exceeding 75mm dia but not exceeding 160 mm dia .
b) Pipe , cables etc. exceeding 200 mm dia but not exceeding 315 mm dia .
Labour charge for repairing of leakage in existing UPVC distribution system including required earth cutting and fitting fixing of necessary coupler etc. complete and refilling the trench with available excavated earth as per direction of the Engineer-incharge. (Payment of couplers, tees, reducers etc will be made separately)
315 mm dia
250 mm dia to 110 mm
Labour charge for laying different dia rigid UPVC pipes of Working Pressure 4.0 kg/ sq.cm. complete with necessary coupler and solvent cement joints.( pipes, coupler andsolvent cement will beissued free of cost ) as per CPWD Specification & direction of Engineer-in-charge.
90 mm dia
110 mm dia
140 mm dia
160 mm dia
200 mm dia
250 mm dia
315 mm dia
Providing and fitting fixing rigid UPVC Reducing socket (one size lower at one end, both end socketted) suitable for pipes of Working pressure 2.5/4.0 kg/sq.cm. as per CPWD Specification & direction of Engineer-in-charge.
315x250 mm dia
250x200 mm dia
200x160 mm dia
160x140 mm dia
140x110 mm dia
110x90 mm dia
Providing and fitting fixing of different dia rigid UPVC unequal Tee (including earth cutting & backfilling all socketted) suitable for pipes as per IS specification of Working pressure 2.5/4.0 kg/sq.cm confirming to IS: 10124 (Part-V) as per CPWD Specification & direction of Engineer-in-charge. Unequal Tee
200x200x110 mm dia
160x160x140 mm dia
160x160x110 mm dia
140x140x110 mm dia
110x110x90 mm dia
Providing and fitting fixing of different dia rigid UPVC equal Tee(including earth cutting & backfilling all socketted) suitable for pipes as per IS specification of Working pressure 2.5/4.0 kg/sq.cm confirming to IS: 10124 (Part-V) as per CPWD Specification & direction of Engineer-in-charge.
140x140x140 mm dia
110x110x110 mm dia
90x90x90 mm dia
Providing and fitting fixing of G.I hydrant suitable for PVC pipes as per standard specification complete as per direction of Engineer-incharge (Rate excluding the cost of NTP control valve). 80X50 mm dia
Providing and fitting fixing of M.S shore manifold made with 3mm thick MS sheet of size one way 315 mm dia & three way 125 mm dia made with suitable flange(all end) including coating with sheet primer(tailpiece if required will be paid separately) including proper alignment with pipe line & earth cutting ,backfilling complete as per direction of Engineer-in-charge.
Providing & fitting fixing rigid UPVC bend(30 degree, 45 degree, 60 degree, 90 degree) for UPVC pipes as per IS specification of working pressure 2.5/4.0 kg/sq.cm as per CPWD Specification & direction of Engineer-in-charge.
140 mm dia
110 mm dia
90 mm dia
Providing & fixing C.I. Sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) as per chapter-20 of CPWD specification and direction of the Engineer-in-charge.
150 mm dia.
125 mm dia.
100 mm dia.
Hiring charge of welding set of single phase with operating staff and carrying upto the site of work including loading and unloading (both way) complete as per direction of Engineer-incharge.
Dismentalling of existing PVC pipe from underground including necessary earth cutting etc.and dismentalled pipes,couplers,tees,etc properly stacking in safe site as per CPWD Specification & direction of Engineer-in-charge. a) Pipes,cables etc. exceeding 75 mm dia but not exceeding 315 mm dia.
Providing & fitting fixing PVC suction hose pipe overall thickness 5mm of best quality at site of work (Pankaj made) of approved quality 150 mm dia
Providing & fitting fixing C.I foot valve of heavy duty at site of work of approved quality. 150 mm dia
Providing & fitting fixing MS hose clamp with nuts & bolts etc. complete at site of work of approved quality. 150 mm dia.
Earthwork in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. -All kinds of soil
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - -All work upto plinth level:
1:3:6 ( 1 Cement: 3 fine sand : 6 graded well burnt brick aggregate 40 mm nominal size)
Supplying & filling in plinth, under floor, foundations etc. With sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete.
First class brick work in foundation and plinth including cost of all materials as required complete:- In cement mortar 1:4 ( 1 cement : 4 fine sand ).
12 mm cement plaster of mix Cement mortar 1:4 (1 cement : 4 fine sand)
Neat cement punning
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_70785.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.52 MB
DNIT.pdf
Tender Documents • 2.32 MB
BOQ_70785.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid