| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹26.7 L+₹1.4 L (5.37%)Rejected-AOC | L2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | SREEJITH S G L1 | seasoncontrol L2 |
|---|---|---|---|---|---|
| 1.00Air conditioning | |||||
| 1.00 | OD84194/2024-2025: Round the clock Operation of 3 Nos 110 TR Air cooled Chiller A/C plant, in the Super Specialty Block, Govt. Medical College Hospital, Thiruvananthapuram including rectifying minor defects which are noticed in the A/C system and make the system in good working condition at all time.This contract will not include supply of any components or spares. But the contractor is liable to engage his workers, round the clock, who must possess ITI certificate in the Trade of AC Mechanic, under Govt. of India(after studying full time regular course) and must surrender the certificate of the personnel before the agreement authority as long as he/she is engaged, and should be sufficiently experienced,Mininimum 2 years after obtaining the certificate and must be capable of replacement of any spares/ components supplied from the department. The contractor shall engage one number the said qualified and experienced A/C Mechanic in each shift. | 365 | Day | 2,580 ₹9,41,700 Lowest | 2,718 ₹9,92,070 |
| 1.00 | OD84195/2024-2025:The Annual Maintenance Contract of one number of 110 TR water cooled DX Chiller includes:-
1. Check and render preventive maintenance service to all equipment every 3 month ie, four times in an year through m/s Blue star limited
2.Attend all breakdown calls immediately
Each service will include;-
a.Checking the functioning of chiller units/AHU Unit/Pumps/Cooling Towers/Controls and all such equipment connected with the chiller machines
b.Free replacing of defective/ worn out parts with new or repaired parts of Compressor/Thermostat/Cutouts etc. as required..
c.Repairing of equipment at site/Service station as the case may be
d.Descaling of condensers /chemical cleaning of evaporator coils/replacement of pre filters.
(e)Replenishing refrigerant gas and compressor oil in the system arising out of system defect, excluding sealed compressor
,f.Checking of compressor for its proper functioning
g. Annual pumping down and re-starting as and when needed.
h.Checking of microprocessor control panel , Control boards ,transducers of packaged chillers/Condensing unit for their correctness and replace if necessary etc as required.
The rate is including the annual periodical servicing of AHUs, repairs and / or replacement of spares such as VFDs, AHU motors, AHU Coils, gate valve, glob valve and chilled water pump and minor repairs in chilled water pipe line, minor sheet metal works including replacement of front grille, dampers, diffusers, hinges and repairing the complaints in electrical control panels including replacement of damaged switch gears. | 3 | each | 2,12,000 ₹6,36,000 Lowest | 2,23,695 ₹6,71,085 |
| 1.00 | OD194601/2025-2026:Charges for filling Refrigerant gas of chiller unit 110TR | 100 | kilogram | 1,120 ₹1,12,000 Lowest | 1,183 ₹1,18,300 |
| 1.00 | 16.2.8:Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable rubber based adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS: 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 100mm dia. (32mm thick nitrile rubber insulation | 10 | metre | 3,500 ₹35,000 Lowest | 3,700 ₹37,000 |
| 1.00 | 16.3.8:Supplying, laying/ fixing, testing and commissioning of following nominal sizesChilled water piping of nominal size - 100mm dia. (50mm thick expanded polysterene) | 10 | metre | 4,060 ₹40,600 Lowest | 4,287 ₹42,870 |
| 1.01 | 16.5.1:Supplying, laying,fixing, testing and commissioning of following thicknessInsulation with nitrile rubber of thickness 32mm on existing pipe | 10 | sqm | 1,310 ₹13,100 Lowest | 1,385 ₹13,850 |
| 1.01 | 16.7.1.4:Supplying,fixing,testing and comissioning of following valves,strainers, guages in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) 100 mm | 29 | each | 8,250 ₹2,39,250 Lowest | 8,700 ₹2,52,300 |
| 1.01 | 16.7.1.5:Supplying,fixing,testing and comissioning of following valves,strainers, guages in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) 80 mm | 10 | each | 5,700 ₹57,000 Lowest | 5,989 ₹59,890 |
| 1.01 | OD194463/2025-2026:Supply of drier core in chiller unit 110TR in place of defective one | 4 | each | 2,350 ₹9,400 Lowest | 2,472 ₹9,888 |
Tender Value
₹25.4 L
EMD Value
₹50,000
Closing Date
29 Oct 2025, 6:00 pmClosed
EXECUTIVE ENGINEER
Office of The Executive Engineer PWD Electrical Division Thiruvananthapuram
DEPOSIT Operation and maintenance contract of SSB from 01/11/2025 to 31/10/2026 3Nos 110TR Air cooled chiller plant-General Electrical Work
2025_PWD_812761_1
EDT_ET_27_2025_26
Open Tender
Electrical Works
Item Rate
THIRUVANANTHAPURAM
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
Yes
₹50,000
Yes
3 Jan 2026
21 Oct 2025
3 Nov 2025
21 Oct 2025
29 Oct 2025
21 Oct 2025
Amount
Air conditioning
OD84194/2024-2025: Round the clock Operation of 3 Nos 110 TR Air cooled Chiller A/C plant, in the Super Specialty Block, Govt. Medical College Hospital, Thiruvananthapuram including rectifying minor defects which are noticed in the A/C system and make the system in good working condition at all time.This contract will not include supply of any components or spares. But the contractor is liable to engage his workers, round the clock, who must possess ITI certificate in the Trade of AC Mechanic, under Govt. of India(after studying full time regular course) and must surrender the certificate of the personnel before the agreement authority as long as he/she is engaged, and should be sufficiently experienced,Mininimum 2 years after obtaining the certificate and must be capable of replacement of any spares/ components supplied from the department. The contractor shall engage one number the said qualified and experienced A/C Mechanic in each shift.
OD84195/2024-2025:The Annual Maintenance Contract of one number of 110 TR water cooled DX Chiller includes:- 1. Check and render preventive maintenance service to all equipment every 3 month ie, four times in an year through m/s Blue star limited 2.Attend all breakdown calls immediately Each service will include;- a.Checking the functioning of chiller units/AHU Unit/Pumps/Cooling Towers/Controls and all such equipment connected with the chiller machines b.Free replacing of defective/ worn out parts with new or repaired parts of Compressor/Thermostat/Cutouts etc. as required.. c.Repairing of equipment at site/Service station as the case may be d.Descaling of condensers /chemical cleaning of evaporator coils/replacement of pre filters. (e)Replenishing refrigerant gas and compressor oil in the system arising out of system defect, excluding sealed compressor ,f.Checking of compressor for its proper functioning g. Annual pumping down and re-starting as and when needed. h.Checking of microprocessor control panel , Control boards ,transducers of packaged chillers/Condensing unit for their correctness and replace if necessary etc as required. The rate is including the annual periodical servicing of AHUs, repairs and / or replacement of spares such as VFDs, AHU motors, AHU Coils, gate valve, glob valve and chilled water pump and minor repairs in chilled water pipe line, minor sheet metal works including replacement of front grille, dampers, diffusers, hinges and repairing the complaints in electrical control panels including replacement of damaged switch gears.
OD194601/2025-2026:Charges for filling Refrigerant gas of chiller unit 110TR
16.2.8:Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable rubber based adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS: 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 100mm dia. (32mm thick nitrile rubber insulation
16.3.8:Supplying, laying/ fixing, testing and commissioning of following nominal sizesChilled water piping of nominal size - 100mm dia. (50mm thick expanded polysterene)
16.5.1:Supplying, laying,fixing, testing and commissioning of following thicknessInsulation with nitrile rubber of thickness 32mm on existing pipe
16.7.1.4:Supplying,fixing,testing and comissioning of following valves,strainers, guages in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) 100 mm
16.7.1.5:Supplying,fixing,testing and comissioning of following valves,strainers, guages in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) 80 mm
OD194463/2025-2026:Supply of drier core in chiller unit 110TR in place of defective one
16.26.2:Supply, Installation, Testing and commissioning of factory built floor mounted chilled water double skin type horizontal/vertical air handling units made of 25mm thick panels consisting of pre plasticized G.I. casing of thickness 0.8mm outside layer and 0.8 mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding machine, complete with blower section with blower suitable for static pressure as required, minimum 2 bend GSS/PVC eliminators, cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5mm) cooling coil of 6 row deep, filter section with 50mm thick metal viscous/ washable synthetic type air prefilters, belt drive package with TEFC drive motor of effecinecy class IE3 suitable for 415 ± 10% volts, 50Hz, 3 Phase AC supply suitably designed for variable frequency drive applications, drain connections, stainless steel (18G) drain pan with PUF insulation, 150 mm dia. dial type pressure gauges (2 nos.) and industrial type thermometers (2 nos.) at the inlet and outlet of coil, auto purge valve wherever required, necessary vibration isolation arrangement etc. complete as per specification and of following capacities.Double skin AHU Units of 6 row cooling of 5100CMH
OD195181/2025-2026:Supply and Installation of 5 HP pump motor in place of defective one and make the unit in good working condition (ABB make ACS380-01-012A-4) ,
OD195234/2025-2026:Supply (Top up) of compressor coil in 110 TR chiller unit and making the unit in good working condition
seasoncontrol (BID ID -2415532)
Bidder Name
seasoncontrol
SREEJITH S G
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.04 MB
BOQ_1358471.xls
BOQ • 0.31 MB
viewsbd.pdf
Additional Documents • 1.63 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .