Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.0 LAccepted-AOC 364 MAHAVEERPURAM BEHIND FUN WORLD CHOPASNI ROAD JODHPUR RAJ | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹15.8 L+₹78,135 (5.20%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
11 May 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) No.2 Jodhpur
GE (AF) No.2 Jodhpur
DAY TO DAY E/M MAINT IN AOR (ENTIRE DOMESTIC AREA OTHER THAN OMQ AS DIAMOND JUBILEE MAP OFFRS CAMP AREA) AT AF STN JODHPUR UNDER AGE E/M, GE (AF) NO 2 JODHPUR
2021_MES_436516_1
8240/E8
Open Tender
Civil Works
Works
330 days
GE (AF) No.2 Jodhpur
As per Tender Documents
6 documents required · 6 mandatory
₹500
GE (AF) No.2 Jodhpur
₹70,000
Yes
8 Jun 2021
15 Apr 2021
13 May 2021
15 Apr 2021
11 May 2021
28 Apr 2021
60 days
Amount
Taking down ceiling fans of any type and size after disconnecting from existing ceiling rose to connector and clamp hooks and transportation to work shop, cleaning externally, dismantling and examining the rotor, startor, bearings, bushes, winding etc; for serviceability and repairing/replacing the defective parts subsequently oiling, greasing, assembling, testing for proper functioning,checking for safety security and proper locking, transporting back to building/site from work shop, hanging and connecting the New electrical connections with new two core flexible wire 01 mtr, testing for noise free smooth running etc as directed. Note :- (i) Minimum 15 Nos ceiling fan any type to be repaired in One Day. (ii) All repairs to be carried out in AGE E/M store Yard. (iii) Repair/replacement of parts will be measured and paid separately under respective items.
Taking down old unserviceable rusted ceiling fan blades and providing new ceiling fan blades with fixing new screws as appropriate shape and size suitable for ceiling fan of any make and size 1200mm sweep complete all as specified and directed by Engr in Charge.
Taking down old unserviceable rusted ceiling fan blades and providing new ceiling fan blades with fixing new screws as appropriate shape and size suitable for ceiling fan of any make and size 1400mm sweep complete all as specified and directed by Engr in Charge.
Taking out existing worn out nut, bolt, rubber bush, cotter pin, and supply and fix new metallic clamps, rubber bush, nut bolt, washer and cotter pin and for various types of ceiling fans to complete the repair work all as specified and directed by Engr in Charge
M & L for painting of ceiling fans along with blades of any make/model of size 1200 to 1400mm sweep with spray paint including filling cavities with filler white in colour synthetic enameled paint, etc complete all as specified and directed by Engr in Charge
Taking out defective/worn out bearing of any make and supply and fix new bearing suitable for various makes of ceiling fans of size 1200 to 1400mm sweep complete all as specified and directed by Engr in Charge
Taking out defective capacitor and supply and fix new capacitor of 2.5 mfd of approved make for various makes of ceiling fans complete all as specified and directed by Engr in Charge
Taking out worn out Gun metal bush and supply and fix new Gun metal bush for various makes of ceiling fans of size 1200 to 1400mm sweep complete all as specified and directed by Engr in Charge
Taking out defective/burnt out windings of ceiling fans of various makes of size 1200 to 1400mm sweep working on 230/250 volt single phase AC supply and rewinding with supper enamelled new copper wire of appropriate gauge including varnishing with good quality varnish' baking up, reassembling the fan, testing including replacement of connector, flexible wire of size 23/0.0040 three core up to one metre all as specified and directed by Engr in Charge.
Taking out rusted/defective down rod and supply and fix new down rod of medium grade GI tubing 15mm bore , 450mm length, having holes and threading at ends as per site requirement complete all as specified and directed by Engr in Charge.
Removing broken/cracked canopy of any make and type and supply and fix new canopy of existing make and size all as specified and directed by Engr in Charge
Taking down exhaust/wall mounted fans of any type and size after disconnecting the connections from existing ceiling rose to connector and transportation to work shop, cleaning externally, dismantling and examining the rotor, stator, bearings/bushes, winding etc for serviceability and repairing/replacing the defective parts subsequently oiling, greasing assembling, testing for proper functioning, checking for safety security and proper locking, transporting back to building/site from work shop, hanging/fixing and connecting the electrical connections, testing for noise free smooth running etc; as directed. Note :- (i) Minimum 05 Nos Exhaust fan any type to be repaired in One Day. (ii) All repairs to be carried out in AGE E/M store Yard. (iii) Repair/replacement of parts will be measured and paid separately under respective items.
M & L for painting of exhaust fans along with blades of any make/model of size 225 to 380mm sweep with spray paint black/existing colour supper enameled paint, writing MES No. in 20 mm letter size with white paint etc complete all as specified and directed by Engr in Charge
All as per item No. 13 above but of size 450mm sweep.
Taking out defective/worn out bearing of any make and supply and fix new bearing suitable for various makes of exhaust fans of size 225/380mm sweep complete all as specified and directed by Engr in Charge
All as per item No. 15 above but of size 450mm sweep by Engr in Charge
Taking out defective capacitor and supply and fix new capacitor of 4 mfd of approved make for various makes of exhaust fans complete all as specified and directed by Engr in Charge
Taking out defective/burnt winding of exhaust fans of various makes of size 225 to 380mm sweep working on 230 to 250 Volts, single phase, AC supply, and rewinding with supper enameled new copper wire of appropriate gauge including varnishing with good quality varnish baking up, reassembling the fan, testing, transportation, replacement of capacitor and connector, flexible copper wire of size 23/0.0040 three core up to one metre complete all as specified and directed by Engr in Charge
All as per item No 18 above but of size 450mm sweep.
Disconnecting water and electric connections and taking down electric water heater (geysers) of any capacity from its mounting place, transporting to workshop (if required) for repairs, re-assembling and refixing the same after repairs , connecting water and electric connections including testing complete all as specified and as directed by Engineer-in-charge.
M & L Copper inner tank/vessel heavy duty fixed in replacement of suitable to the existing 25 litres capacity geysers any make complete all as specified and as directed by Engr-in-Charge .
M & L Copper inner tank/vessel heavy duty fixed in replacement of suitable to the existing 50 litres capacity geysers any make complete all as specified and as directed by Engr-in-Charge .
Taking out old thermostat / heating element and refixing the same after descaling/cleaning and making electric connection and calibrating/adjusting to a temperature rating as per manufacturer recommendations including replacing unserviceable brunt worn out spare (syphon assembly , gyser assembly, non return valve , safety valve,NRV, drain out plug ,brass valve ,lamp indicators ) fixing the same aligned and resembling ensuring right DOR, complete all as directed by Engr in charge. Note:- Heating Element, Thermostat ,syphon assembly , gyser assembly, non return valve , safety valve,NRV, drain out plug ,brass valve ,lamp indicators shall be measured and paid for separately as supply only but fixing is included in this items)complete all as directed by Engr in Charge.
S & F Heating element triangular or square type of rating 1.5 KW, 230 volts ISI marked,including rubber washer fixed in repairs complete all as specified and as directed by Engineer-in-charge.
S & F Heating element triangular or square type of rating 2 KW, 230 volts ISI marked,including rubber washer fixed in repairs complete all as specified and as directed by Engineer-in-charge.
S & F Thermostat auto cut with thermal setting upto 80 degree centigrade, 230 V, for the geysers 25/35/50 Ltrs capacity as per site requirement fixed in repairs complete all as specified and as directed by Engr-in-Charge .
S & F Syphon assembly suitable for 25 litre capacity geyser any make, fixed in repairs complete all as directed by Engr in Charge
S & F Syphon assembly suitable for 50 litre capacity geyser any make, fixed in repairs complete all as directed by Engr in Charge
S & F Apparatus plate (Geysers assembly) suitable for existing Geysers of Cap 25 Litres of copper /brass complete with nuts and bolts and rubber washers fixed in repairs complete all as specified and directed by Engr in Charge
S & F Apparatus plate (Geysers assembly) suitable for existing Geysers of Cap 50 Litres of copper /brass complete with nuts and bolts and rubber washers fixed in repairs complete all as specified and directed by Engr in Charge
S & F Non return valve 15mm bore,as per site requirement fixed in repairs complete all as specified and as directed by Engr-in-Charge . ISI marked.
S& F Safety valve/high pressure valve 15mm bore,as per site requirement fixed in repairs complete all as specified and as directed by Engr-in-Charge . ISI marked.
M & L Insulating material (i. e. glass wool) fixed in 25/50 ltr capacity geyser. complete, all as specified and as directed by Engr-in-Charge.
S & F Indicator lamp red/green fixed in repairs complete all as diercted. by Engr in Charge
S & F Drain plug of suitable size for 25/50 ltr capacity geyser complete all as directed by Engr in Charge
S & F Ball brass valve 15 mm bore fixed in repairs complete all as directed
S & F Heat resistant heavy duty pressure grade 6 kg/sq cm ,braided PVC connecting pipe with brass adapters 450 mm long suitable for 15 mm dia pipe and fixed in position as in repairs complete all as approved by Engineer-in-charge.
S & F Metallic 3 pin top plug, 5 Amps fixed in repairs complete all as directed. by Engr in Charge
S & F Metallic 3 pin top plug, 15 Amps fixed in repairs complete all as directed. by Engr in Charge
S & F Single pole and neutral enclosure with a two pin socket complete with one single pole MCB 20 Amp complete all as specified and directed. by Engr in Charge
M & L in repair sub main wiring with 2 single core, 10 Sq. mm, PVC insulated unsheathed,multi stranded copper conductor FR cable 1100 Volts grade including 10 Sqmm PVC insulated unsheathed multi stranded copper conductor FR as continuous earth wire drawn through Casing caping and connecting to common earth terminals complete all as specified and directed by Engr in Charge. Note :- (i) Two runs of copper cable and one run of earth wire including conduit /PVC casing/caping shall be measured as one length.
All as per item No - 41 above but with 2 runs of 6 Sqmm cable with one run of 6.0 Sqmm cable for earthing.
All as per item No - 41 above but with 2 runs of 4 Sqmm cable with one run of 4.0 Sqmm cable for earthing.
All as per item No - 41 above but with 2 runs of 2.5 Sqmm cable with one run of 2.5 Sqmm cable for earthing.
Taking down carefully aluminium/copper point wiring (light ,fan, socket or power)complete, including fittings & fixtures such as switches, ceiling roses, pendents, regulators, sockets,bell push,bell,light fittings etc.removing materials to store for keeping in safe costudy or for taking credit (credit for shall be made as per Sch of credit) and making good disturbed surface of walls, floors etc. to match to the existing surfaces.
Material and labour for point wiring with two runs of stranded copper conductor PVC insulated unsheathed 1.5 Sqmm FRLS cable in and including PVC conduit / casing caping of suitable size with PVC boards of appropriate sizes and all requisite accessories complete with PVC terminals box for mounting switches, sockets, fan regulators etc with one single core continuous 1.5 Sqmm,FRLS copper cable for earth wire complete all as specified and as directed by Engr in Charge for One light point controlled by one switch.
All as per Item No-46 but One light point controlled by two two way switches.
All as per Item No-46 but One fan point controlled by one switch
All as per Item No-46 but One 3 pin socket outlet 5 Amps on the same board.
All as per Item No-46 but One 3 pin socket outlet. 5 Amps on the Independent. board
All as per Item No-46 but One bell point controlled by one switch
Material and labour for point wiring with two runs of stranded copper conductor PVC insulated unsheathed 2.5 Sqmm FRLS cable in and including PVC conduit /casing caping of suitable size with PVC boards of appropriate sizes and all requisite accessories complete with PVC terminals box for mounting switches, sockets, fan regulators etc with one single core continuous 1.5 Sqmm,FRLS copper cable for earth wire complete all as specified and as directed by Engr in Charge for One 15 A socket outlet independent .
All as per Item No-47 but One 15 A socket outlet on the same board
S&F in repair switch piano, flush type 230 Volt 5 amps single pole one way ISI marked all specified
S&F in repair switch piano, flush type 230 Volt 5 amps single pole two way ISI marked all specified
M & L for switch socket combination 2 in 1 3 pin 5 Amps flush type (multi purpose ) complete all as specified and as directed.
M & L for switch socket combination 2 in 1, 3 pin, 5 and 16 amp flush type universal complete all as specified and as directed.
S&F in repair Bell Push, flush type 5Amps 240 volt ISI marked
M&L in repair for ceiling rose surfaces bakelite 65 x 50mm white coloured 2 to 3 terminals
S&F in repair electric Bell ding dong AC. 230volt single pole.
S&F in repair angle holder, insulated polycabonate body with back plate complete.
Supply and fixing fan electronic regulator 300w step type all as specified and as directed by Engr-in-Charge.
Supply and fix Modular type switch, 1 way,10 Amps, 1 module (as per site reqmt)
Supply and fix Modular type switch, 1 way, 16 Amps, 1 module (as per site reqmt)
Supply and fix Modular type socket, 6A 3 pin, combined, 2 module (as per site reqmt)
Supply and fix Modular type socket, 6/16A 3 pin, combined, 2 module (as per site reqmt)
Supply and fix Modular type fan regulator step type 120 W 2 module (as per site reqmt)
Taking down old MCB DBs any size incl MCBs complate all as specified and as directed by engr-in-charge.
S&F MCB distribution board, powder coated, CRCA steel sheet, degree of protection IP 43 - IK 09 with reversible double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with SPN, 240 volts, 4 ways.
S&F MCB distribution board, powder coated, CRCA steel sheet, degree of protection IP 43 - IK 09 with reversible double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with SPN, 240 volts, 8 ways.
S&F MCB distribution board, powder coated, CRCA steel sheet, degree of protection IP 43 - IK 09 with reversible double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with TPN, 415 volts, 4 ways.
S&F MCB distribution board, powder coated, CRCA steel sheet, degree of protection IP 43 - IK 09 with reversible double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with TPN, 415 volts, 8 ways.
Supply and fix in repair MCB four pole 415 V 100 Amps C Curve 16KA complete all as specified and directed by Engr in Charge. Make : L&T/ Legrand/ Siemens
Supply and fix in repair MCB triple pole and neutral 415 V 63 Amps "C' Curve 16KA complete all as specified and directed by Engr in Charge. Make : L&T/ Legrand/ Siemens
Supply and fix in repair MCB TP 40 to 63 Amps, 'C' Curve 240 volts complete all as specified and directed by Engr in Charge. Make : L&T/ Legrand/ Siemens.
Supply and fix in repair MCB SPN 20 to 40 Amps, 240 volts complete all as specified and directed by Engr in Charge. Make : L&T/ Legrand/ Siemens.
Supply and fix in repair MCB SP 5 to 32 Amps, 240 volts complete all as specified and directed by Engr in Charge. Make : L&T/ Legrand/ Siemens.
Supplying and Fixing/connecting for service connection/ Garden light connection, 1100 volts grade heavy duty Cable PVC insulated aluminium multy sranded conductor, twin core cable circular of sizes 10 Sqmm 2 Core complete all as Specified and directed.
----Ditto---- above item no- 73 but sizes 6 Sqmm 2 Core.
----Ditto---- above item no- 73 but sizes 4 Sqmm 2 Core.
S & F Three core copper conductor cable flexible of size 1.5 sqmm complete all as directed.
S & F Three core copper conductor cable flexible of size 2.5 sqmm complete all as directed.
S & F PVC casing/caping of size 32/25 mm fixed in repairs complete all as directed.
S & F PVC conduit pipe of size 20/25 mm fixed in repairs complete all as directed.
S&F Building security light fittings, with pressure die cast aluminium housing, suitable for 25 W LED, complete pre-wired, incl suitable bracket for fixing light on wall or any indicated locaction all as specified and as directed by Engr in Charge. Make: Havells (Cat No: ENDURAPEARLSL25W) or equivalent model in Philips / Syska.
Earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick burried directly in ground vertically at a depth not less than 2.25 metre deep below normal ground level with top edge of the plate not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt, filling in alternate layer and electrode connections by using galvanized iron earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers made of galvanized iron or steel and protected by light grade 15 mm dia GI pipe connected to main switch board or main control board, and GI pipe light grade 20 mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC 1: 2: 4 type C2 including excavation and earth work, disposal of surplus soil to a distance not exc. 50 mtr all as specified and as shown on Plate No 5 of SSR Part I (2009) including dismantaling of existing unserviceable earth pit all as specified and directed by Engr-in-Charge.
M/s Bakiyalakshmi Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .