Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.4 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹33.9 L+₹1.9 L (6.07%)Rejected-Finance 33 JAGGI GARDEN NARAINGARH ROAD AMBALA CITY 134003 | AMBALA | HARYANA | 134003 | L2 | Rejected-Finance Rejected being | |
| 3 | L3₹35.4 L+₹3.4 L (10.7%)Rejected-Finance 6313 14 PUNJABI MOHALLA AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L3 | Rejected-Finance Rejected being | |
| 4 | L4₹35.7 L+₹3.7 L (11.6%)Rejected-Finance | L4 | Rejected-Finance Rejected being | |
| 5 | L5₹38.9 L+₹6.9 L (21.7%)Rejected-Finance | L5 | Rejected-Finance Rejected being |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
1 Dec 2021, 6:00 pmClosed
GE(NORTH) AMBALA CANTT
GE(NORTH) AMBALA CANTT
SPECIAL REPAIR TO SINGLE LIVING JCOS ACCN BUILDING NO HT-11 AT HAIG LINE, PROVISION OF ADDITIONAL TOILETS TO BUILDING NO. P-35 AT MALL ROAD AND FOR TROOPS OF DEFENCE AND UPGRADATION OF BATHROOM AND TOILET ETC IN MD A
2021_MES_462684_2
GE(N)Amb-32/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE(NORTH) AMBALA CANTT
As per tender documents
7 documents required · 7 mandatory
₹500
GE(NORTH) AMBALA CANTT
₹84,000
Yes
21 Dec 2021
27 Oct 2021
3 Dec 2021
27 Oct 2021
1 Dec 2021
17 Nov 2021
27 Oct 2021 - 17 Nov 2021
Amount
Schedule 'B' Part-I (B/R itmes) Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation etc or for shafts, wells, manholes etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed by the Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and as directed by Engineer-in-Charge.
Removing excavated material to a distance exc. 250 metre and not exceeding 500 metre and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed by Engineer-in-Charge.
M & L PCC 1:4:8 Type D2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M & L sand filling including supply of sand under floors or in foundations including watering and consolidation complete all as specified and as directed by the Engineer-in-Charge.
M & L plain cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including formwork for rough finished surfaces of concrete complete all as specified and as directed by the Engineer-in-Charge.
M&L TMT steel bars 10mm dia and over cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge.
M&L TMT steel bars 6 to 8mm dia cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge.
M&L TMT steel bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge.
M & L formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports overhangs etc, also splays between floors and beams, etc., work in rough finished flat surfaces of concrete complete all as specified and as directed by the Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing servicable tiles to store and rubbish off the premises complete all as specified and as directed by the Engineer-in-Charge.
M & L RCC 1:1.5:3 (Nominal mix) type A1 using 20mm graded crushed stone aggregates as in beams, cantilevers, lintels over 1.5 mtr span complete all as specified and as directed by the Engineer-in-Charge.
M&L Non-skid ceramic coloured tiles joint free 1st quality (square/rectengular) 7 to 8 mm thick, area of each tile exc 0.11 sqm but not exc 0.18 sqm as in floors, set and jointed in neat cement slurry and pointed in coloured cement to match the surface over and including screed bed or bedding layer 15 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and as directed by the Engineer-in-Charge.
M&L glazed ceramic coloured tiles joint free 1st quality in vertical surfaces/skirtings/dados of size 450x300x7mm/450x350x7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement mixed with pigment to match over and including 10mm thick rendering on fair faces of brick / concrete surfaces in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M & L 25mm thick cement concrete 1:2:4 type B-0, using 12.5mm graded crushed stone aggregates as in sub base of floor and finished even and fair to receive tiles etc. complete all as specified and as directed by the Engineer-in-Charge.
S&F box type using ERW hollow 'P' section ventilators glazed/gauged, fixed type including MS grills of square bar 10mm dia @ 100 c/c complete with glazing bars dovetailed or welded complete all as specified and as directed by the Engineer-in-Charge.
Dismantling of plain or corrugated asbestos cement sheet of any thickness incl Nainital or similar pattern coverings, complete all as specified and as directed by the Engineer-in-Charge.
S & F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick having zinc coating 150 grams per Sqm (Az 150) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by the Engineer-in-Charge.
S & F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa having zinc coating 150grams/Sqm (Az-150) as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by the Engineer-in-Charge.
Taking down roof trusses, coupled rafters or trussed beams, clear span above 8 metres & upto 12 metres complete all as specified and as directed by the Engineer-in-Charge.
S & F rolled mild steel work in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. of Fe-410-W (Grade E-250) quality B complete all as specified and as directed by the Engineer-in-Charge.
S & F 16-20mm dia of shank mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 22.5cm but n exc 30cm long complete all as specified and as directed by the Engineer-in-Charge.
M & L mild steel work in hand rails, half round or other stock section or core for wooden handrail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc, and similar work conforming to Fe 410-W (Gde E-250) quality 'A' complete all as specified and as directed by the Engineer-in-Charge.
Demolition of brick work built in cement mortar or cement lime mortar including all quoins, arches, pillar etc but excluding ashlar facing, dressed stone work and precast concrete articles complete all as specified and as directed by the Engr-in-charge.
M&L brick work with sub class 'B' old size bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 complete all as specified and as directed by the Engineer-in-Charge.
M & L brickwork with sub-class `B` bricks old size in half brick thick wall straight or curved on plan to any radius built in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M & L damp proof course to horizontal or vertical surfaces including necessary formwork, 40mm thick, in cement concrete 1:2:4 type B0 using 12.5mm graded crushed stone aggregate complete all as specified and as directed by the Engineer-in-Charge.
M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), work in rough finished flat surfaces of concrete complete all as specified and as directed by the Engineer-in-Charge.
M & L formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide, for roughed finished surface of concrete complete all as specified and as directed by the Engineer-in-Charge.
M & L RCC 1:1.5:3 (Nominal mix) type A1 using 20mm graded crushed stone aggregates as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by the Engineer-in-Charge.
M & L taking down cement or cement lime plaster of any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed by the Engineer-in-Charge.
M&L 15mm thick internal cement plaster in cement mortar 1:6 on any faces of brick work or concrete surfaces, finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in charge.
M&L 15mm thick external cement plaster in cement mortar 1:4 on any faces of brick work or concrete surfaces using WPC @3% by weight of cement or as per manufacturer's instruction, finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in charge. (WPC shall be measured and paid for separately)
M&L rendering 5 mm thick on fair faces of brick work or concrete ceiling surfaces in cement mortar 1:3 and finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Supply only integral water proofing compound complete all as specified and as directed by the Engineer-in-Charge.
M&L rough cast plaster complete as specified in SSR Part-I, clause 14.22 shall consisting of following:- firstly apply under coat in cement mortar 1:3 not less than 10 mm thick and while still it is in plastic state the rough cast mixture consisting of crushed stone or fine gravel agg. which is generally of size between 6 to 12 mm depending on texture required mixed with coarse sand and cement in the ratio 1:1:1 shall be applied, complete all as specified and as directed by the Engineer-in-Charge.
M & L preparing new plastered surfaces of wall and applying two coats of oil emulsion distemper with painting roller over and including 1 to 2mm thick wall care putty white cement based in two or more coats to achieve smooth surfaces complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of newly plastered surfaces of wall and applying two coats of cement base paint complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of new plastered/ unplastered surfaces of brick/concrete ceiling and applying three coats of white lime wash complete all as specified and as directed by the Engineer-in-Charge.
M&L broken stone hardcore of gauge not exc. 63mm, deposited , spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface complete all as specified and as directed by the Engineer-in-Charge.
M & L providing 75 mm thick cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregates as in plinth protection laid in alternate bays (n exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight including form work complete all as specified and as directed by the Engineer-in-Charge.
Taking down chowkhats or frames with shutters (without taking off shutter from the frames) area n. exc 1.5 Sqm each and removal from site complete all as specified and as directed by the Engineer-in-Charge
Taking down chowkats or frames with shutters (without taking off shutters from the frames) area exc 1.5 sqm but not exc 4 sqm each and removing the same from site complete all as specified and as directed by the Engineer-in-charge.
Supply and fixing steel window box type using ERW hollow 'P' section comprising double frame for and including gauged and glazed skelton shutter 30mm thick, jointed internally with flat iron 25x3mm complete including hinges, handle, tower bolts, stops, lugs, guard bars and painting etc. all as shown on drawing No. TD-219 sheet 1/3 to 3/3 and TD-220 sheet 1/3 to 3/3 as applicable complete all as specified and as directed by Engineer in Charge. Note: (i) For the purpose of measurement and payment double shutter both glazed and gauzed with frames shall be considered as one unit. (ii) Unit rate quoted against this item shall also include the iron mongery and grill fabricated from 10mm square bar as shown on drgs. (iii) Glazing, wire mesh shall be measured and paid for separately.
M&L rolled mild steel framed work as in chowkats of door or gates of angle or other section with gusset plates, rails braces etc. complete. drilled for fixing for steel sheeting or other covering doors, etc to be prepared for hanging or sliding with and including either hooks and hinges and hanging ,door fitting (exclusive of steel sheeting or other covering, running rails and guides) also fastening and fixing conforming to Fe-410-(Gde E-250) quality 'A' complete all as specified and as directed by the Engineer-in-Charge.
M&L factory made 2nd class hard wood 35 mm thick plain framed panelled shutter( two panel) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on boths face . The size of rail and style as per IS:1003 (Part-1) kiln seasoned and chemically pressure treated complete all as specified and as directed by the Engineer-in-Charge.
M&L factory made 35 mm thick 2nd class hard wood glazed and skeleton shutters,open rebated and prepared to receive glass , gauze etc. (without sash bars) ,edges of framing plain chamfered or rounded , fitted with cut and mitred beads for securing glass etc size of members of shutters as specified in SSR Part-I, Section-8, clause 8.24 (a) (wood shall be kiln seasoned and chemically pressure treated) complete all as specified and as directed by the Engineer-in-Charge.
S&F 150 mm long aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing 300mm long aluminum alloy, anodized sliding bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloys to door shutter complete all as specified and as directed by the Engineer-in-Charge.
S&F 150 mm long aluminium handle cast type anodised complete all as specified and as directed by the Engineer-in-Charge.
S & F 2nd class hardwood small fittings such as brackets of any type, latch and hinge blocks, shapped door and window stops and the like, including all necessary labours; articles n exc 200 cu. cm each complete all as specified and as directed by the Engineer-in-Charge.
S & F bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required, hooks (stay), heavy, for large gates, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe 290 Gde-E-165 complete all as specified and as directed by the Engineer-in-Charge.
S&F stainless steel wire cloths 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with tinned tack or stainless steel wire staple complete all as specified and as directed by the Engineer-in-Charge.
M & L sheet glass 4.00 mm thick ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and as directed by the Engineer-in-Charge
M&L preparation of new plastered/ unplastered surfaces of brick/concrete wall and applying three coats of white lime wash complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and as directed by the Engineer-in-Charge.
S & F stainless steel butt hinges 100mm long medium weight complete all as specified and as directed by the Engineer-in-Charge.
Supply only stainless steel butt hinges 50mm long medium weight complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of new or previously untreated wooden surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed by the Engineer-in-Charge.
Dismantling wall and ceiling boards (fiber pulp, insulation etc) or insulation boards/ slabs/blankets any thickness including cover fillets and false ceiling frame /gird of any type/any description, fixed in position,complete all as specified and as directed by the Engineer-in-Charge.
S & F of fixing GI Metal Suspended ceiling of approved materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint and including GI Metal Ceiling laying perforated Tegular edge global white colour tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.
Taking up or down 20mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed by the Engineer-in-Charge.
M & L galvanised iron tubing 20 mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge.
Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed by the Engineer-in-Charge.
M & L galvanised iron tubing 15mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge.
M & L 500 Litres rotational moulded polyethylene water storage tanks triple layer (cylindrical vertical with closed top) 100% UA stablised, rust proof, hoisted and fixed in position all as specified in SSR Part-I complete all as specified and as directed by the Engineer-in-Charge. Note:- Tank shall be in white colour.
S & F vitreous china squatting pan, Orissa pattern, of size 580 mm x 440 mm white with integral foot rest complete including provn of cement concrete bedding and connection to trap, outgoing flushing pipe, anti syphonage pipe complete all as specified and as directed by the Engineer-in-Charge.
S & F 15mm bore cast copper alloy chromium plated stop valves, screwed down, high pressure with butterfly handle, scrwed both ends for iron pipe or for unions complete all as specified and as directed by the Engineer-in-Charge.
S & F 20 mm bore cast copper alloy chromium plated stop valves, screwed down, high pressure with butterfly handle, scrwed both ends for iron pipe or for unions as in repair complete all as specified and as directed by the Engineer-in-Charge.
S & F bib tap 15mm bore cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed by the Engineer-in-Charge.
S & F bib tap 15mm bore cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule and fixed as in repair complete all as specified and as directed by the Engineer-in-Charge.
S&F brass chromium plated overhead shower 200mmx200mm square shape single flow ABS body chrome plated with grey face plate with rubit clean system complete all as specified and directed by Engr-in-Charge.
M & L 16 to 18 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15mm thick rendering in CM 1:4 complete all as specified and as directed by the Engineer-in-Charge
M & L rounding to edges of stone slabs one edge, such as in steps in cooking platform and similar situation complete all as specified and as directed by the Engineer-in-Charge.
M & L precast RCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in CM 1:4 complete with joints to match, except blocks or slabs complete all as specified and as directed by the Engineer-in-Charge.
M&L machine pressed rubber moulded coloured precast concrete interlocking paver block, any shape and size conforming to IS 15658-2006 of 60 mm thickness, grade M-35 with grey cement and pigments over and including a layer of sand cushioning, 25 mm thick complete all as specified and as directed by the Engineer-in-Charge.
M & L 75 mm thick PCC 1:4:8 Type D2 using 40mm graded crushed stone aggregate as in sub base of floor/ hard standing etc and finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Cutting chases ,pinning in making good to facing where required and pointing in CM 1:3 to edges of landing , steps , cills , sunshades, shelves , lintel etc. and cutting chases for concealed water tubing etc and making good cutting not exc 10 cm girth complete all as specified and as directed by the Engineer-in-Charge.
S & F 10 ltr PVC valveless syphonic action type flushing cistern with brackets, flush pipe etc complete including inlet ball valve float and handle including brackets, of approved make including all connections & flush pipes for WC complete all as specified and as directed by the Engineer-in-Charge.
S & F 20 mm dia ball brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed by the Engineer-in-Charge.
S & F 20 mm bore Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed by the Engineer-in-Charge.
S & F 15 mm bore Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed by the Engineer-in-Charge.
S & F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall complete all as specified and as directed by the Engineer-in-Charge.
S & F 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed by the Engineer-in-Charge.
S & F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors or fixed to wall complete all as specified and as directed by the Engineer-in-Charge.
S & F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floor complete all as specified and as directed by the Engineer-in-Charge.
S&F 110mm bore PVC (SWR) vent cowl etc complete all as specified and as directed by the Engineer-in-Charge.
S&F 110mm bore PVC (SWR) juction single (Single T) equal are unequal complete all as specified and as directed by the Engineer-in-Charge.
S & F 110mm bore PVC (SWR) bends of any radius with access doors complete all as specified and as directed by the Engineer-in-Charge.
S & F PVC (SWR) gully trap 125/110mm, setting and jointing with solvent cement complete all as specified and as directed by the Engineer-in-Charge.
S & F vitreous china wash hand basin white, flat back of size 550mmx400mm fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe including fixing of waste fitting etc complete all as specified and as directed by the Engineer-in-Charge.
S & F vitreous china wash hand basin white, flat back of size 550mmx400mm fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe including fixing of waste fitting etc as in repair complete all as specified and as directed by the Engineer-in-Charge.
S&F 32 mm dia PVC waste pipe of standard length for wash hand basin / Kitchen sink etc complete all as specified and as directed by the Engineer-in-Charge.
Supply & fixing pillar tap 15mm bore, cast copper alloy with capstan heads, chromium plated, screwed down, high pressure, with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed by the Engineer-in-Charge.
Supply & fixing pillar tap 15mm bore, cast copper alloy with capstan heads, chromium plated, screwed down, high pressure, with long screwed shanks and fly nuts, screwed for iron pipe as in repair complete all as specified and as directed by the Engineer-in-Charge.
S & F PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and as directed by the Engineer-in-Charge.
S & F powder coated (minimum thickness of powder coating 50 micron) aluminum window sliding type made out of hollow extruded aluminium section of size 63.50mm x 38.18mm x 2mm thick for channel of window shutter, 45.50mm x 27mmx 1.40mm thick for frame of window shutter including necessary jointing cleats , glazing clips , aluminium powder coated snap beading ,screws, aluminium beading, PVC packing , aluminium fittings and other necessary fittings & fixtures such as 01 No 100mm size 'D' type handel (Decorative type), 02 Nos tower bolts 150mm long in each shutter with necessary fittings and fixtures complete all as specified and directed by Engineer -in-charge.
S & F anodised aluminium grill (anodized transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/ pattern, with approved standard section and fixed to the window frame with C.P brass/ stainless steel screws @ 200 mm center to center, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodized aluminium standard section around the opening, complete all as specified and as directed by the Engineer-in-Charge.
S&F powder coated (minimum thickness of powder coating 50 micron) aluminium door made out of hollow extructed aluminium section of size 101.60 x 44.45 x 1.55 mm for chowkhat, 85 x 44.45 x 1.56 mm for vertical style of shutter, 83.5 x 44.45 x 1.54 mm for middle rail of shutter , 85 x 44.45 x 1.54 mm for top rail of shutter and 150 x 44.45 x 1.54 mm for bottom rail of shutter including neccessary joining cleats, glazing clips, rubber packing, powder coated aluminium snap beading, screws, anodised aluminium fittings such as aluminium tower bolts 200 mm long (2 Nos.), hinges type B-21, 125 mm long (4 Nos.), 150 mm long aluminium handle D or disk type (2 Nos.) complete all as specified and as directed by the Engineer-in-Charge.
S&F aluminium (Diecast) body hydraulically door closer regulated,designation No.3, universal type,suitable for door shutters of 851 mm to 1000 mm in width and weight between 61 to 80 Kg complete all as specified and as directed by the Engr-in-charge.
Supply and fixing 5.5 mm thick tinted glass to aluminium frame work with glazing clips, rubber etc complete all as specified and as directed by the Engineer-in-Charge.
S & F 18mm thick lead free PVC celuka ply of both side plain white colour fixed with screws solvent cement/ adhesive to make kitchen/bed rooms cabinet sides, top and bottom and shelves inside the cabinets including fancy knobs complete all as per manufacturer,s specification/ instructions complete all as specified and as directed by the Engineer-in-Charge.
S & F Continuous (piano) hinges, width of flaps 30mm mild steel, bright finish or electro galvanised complete all as specified and as directed by the Engineer-in-Charge.
M & L carring out roof treatment consisting of following:- 1. Cleaning of concrete roof surface by roughening, picking, sweeping, cleaning and washing down with water to remove dust etc, 2. Brushing neat cement slurry with 3.0 kg of cement per sq. metre. 3. Material & Labour for providing and laying 3mm thick APP (atactic polypropylene polymer) modified prefabricated five layer weight not less than 3.60 kg /Sqm water proofing membrane black finish reinforced with non woven polyster matt and consisting of a coat bitumious primer @ 0.40 ltr /Sqm by the same membrane manufactures of density 0.87 to 0.89 kg/ltr at 25 degree centegrate temprature and viscosity 70-160 cps over the primer coat with overlap of 100mm at the side and 150mm at the end, the layer membrane shall be laid using butane gas torch and sealing all joints etc after preparing the surface complete as per standred practice as per manufacture's instructions . The vital physical and chemical parameters of the membrane shell be under ;- (i) Joint strength in longitudinal and transverse direction at 23 degree centegrate at 650/ 450 N /5 cms (ii) Tear strength in longitudinal and transverse direction at 300/250N/5 cms. Softing point of membrane not less then 150 degree centegrate when tested in accordance with ASTM (d-5147) (iii) The laying of membrane shell be got down through the authorised applicator of manufactures of membrane only complete all as specified and as directed by the Engineer-in-Charge.
S & F single piece water closet wtih PP soft close seat cover, hinges, fixing accessories and accessories set, cistern fittings, S or P Trap complete fixed complete all as specified and as directed by the Engineer-in-Charge. Make : Jaquar Cat Part No SLS -WHT-6855S /CERA Cat part No.S10131095 /Hindware Cat Part No.20085 (S-30)
S & F counter top vitreous china wash hand basin white of size 515mmx365mmx120mm, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe including fixing of waste fitting etc complete all as specified and as directed by the Engineer-in-Charge. Make : Jaquar Cat Part No FLS -WHT-5931 /CERA Cat part No.S2020108 /Hindware Cat Part No.91041
S & F brass CP toilet paper holder including fixing with brass screws to wall complete fixed complete all as specified and as directed by the Engineer-in-Charge. Make : Jaquar Cat Part No : AKP-35753PS/Cera Cat Part No.F5007109 / Hindware Cat Part No.F 840009
S & F brass chromium plated hand shower ( health faucut) with 8 mm dia 1.2 mtr long flexible tube and wall hook with NRV ( back flow preventor )complete fixed to wall complete fixed as in repair complete all as specified and as directed by the Engineer-in-Charge. Make : Jaquar Cat Part No : ALD577/Cera Cat Part No. F8030101
S&F brass chromium plated soap dispenser with glass bottle complete all as specified and directed by Engr-in-Charge. Make- Jaquar/Hindware/CERA
S & F brass CP Towel ring round between flanges including fixing with brass screws complete fixed complete all as specified and as directed by the Engineer-in-Charge. Make : Jaquar Cat Part No : ACN-1121BN/Cera Cat Part No.F5007105 / Hindware Cat Part No.F 880007
S & F brass CP SOAP DISH HOLDER including fixing with brass screws to wall complete fixed complete all as specified and as directed by the Engineer-in-Charge. Make : Jaquar Cat Part No : ACN-1131N/Cera Cat Part No.F500716 / Hindware Cat Part No.F 840006
S & F brass CP corner glass slelf (with bracket) including fixing with brass screws to wall complete fixed complete all as specified and as directed by the Engineer-in-Charge. Make : Jaquar Cat Part No : ACN-1173/Cera Cat Part No.F5005101 / Hindware Cat Part No.F 890009
S&F brass chromium plated concealed stop cock with long shank and wall flange scrwed down,high pressure with butterfly handle, screwed down both ends for iron pipe or for unions 15mm bore of make:- Jaquar cat part No.CON-083FTK or Hindware cat part No. F280027 complete all as specified and as directed by the Engineer-in-Charge.
S & F CP Brass wash hand basin mixer for mixing hot and cold water screwed down for 15mm dia pipe including waste popup waste with 450mm long braided hoses and all connecting fittings complete fixed all as specified and directed. Make :Jaquar Cat Part No QQP-7167BPM / Cera Cat Part No.F2007461 / Hindware Cat Part No.F 480011
S & F CP brass wall mixture 3-in-1 system with provision for both hand shower and overhead shower complete with 115 mm long bend pipe , connecting legs & wall flange without hand & overhead shower complete all as specified and as directed by the Engineer-in-Charge. Make :Jaquar Cat Part No QQT-7309 /Hindware Cat Part No.F 120019
S & F 150mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed by the Engineer-in-Charge.
M&L for concrete bed to drain pipes of bore 150mm including packing under,and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate including necessary shuttering and supports complete all as specified and as directed by the Engineer-in-Charge. Note:-(i) Thickness of bed belew barrel of pipe -10 cm (ii) Width of bed :- outer dia of pipe plus 30 cm.
M & L loose filling with broken bricks aggregate of gauge 80 to 150mm in soakage pits, soakage wells, complete all as specified and as directed by the Engineer-in-Charge.
M & L brickwork with sub-class `B` bricks old size in one brick thick honey-comb wall straight or curved on plan to any radius built in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
S & F 18mm thick lead free PVC celuka ply of both side plain of approved colour other than white colour fixed with screws solvent cement/adhesive to make kitchen /bed rooms cabinet sides, top and bottom and shelves inside the cabinets including fancy knobs complete as per manufacturer,s specification/ instructions complete all as specified and as directed by the Engineer-in-Charge.
S & F solid PVC door frame of size 50mm x 47mm made out of 5mm prelam PVC sheet on single side used instead of plain colour PVC sheet reinforced with MS square tube, edges will be painted to match with prelam sheet and fixed in opening complete all as specified and as directed by the Engineer-in-Charge.
S&F factory made solid PVC moulded door shutters with partical board core 28 to 30 mm thick (styles) with 2, 4, or 6 raised panel design with 2 mm thick prelaminated moulded PVC sheet on the front face and 2mm thick plain colour PVC sheet on back face fixing in frame at site as per specification and drawing complete all as specified and as directed by the Engineer-in-Charge.
S & F angular type 15mm bore cast copper alloy chromium plated stop valves, screwed down, high pressure with butterfly handle, scrwed both ends for iron pipe or for unions complete all as specified and as directed by the Engineer-in-Charge.
S&F 125 mm dia brass chromium plated shower rose swivel type with arms of standard length complete all as specified and as directed by the Engineer-in-Charge.
S & F brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and as directed by the Engineer-in-Charge.
Taking down loose plaster from ceiling of slab, edges and soffit of chajjas and the like, cleaning surface with wire brush to remove all dust/dirt/loose particles to expose old steel reinforcement, applying neat cement slurry@ 3Kg per sqm and 30mm thick (in two layers , each layer 15mm thick) plaster in cement mortar 1:3 not exc 3 sqm each patch including removal of rubbish/demolished material to a distance exceeding 250mtr and not exc 500mtr , including scaffolding complete all as specified and as directed by Engineer-in charge .
M & L preparation of old decorated brick/concrete, plastered / un--plastered surfaces of walls by brooming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of oil bound distemper with painting roller over prepared surfaces of the walls, pillars, cornices etc. complete all as specified and as directed by the Engr-in-charge.
M & L preparation of old decorated brick/concrete, plastered / un--plastered surfaces of ceiling by brooming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of white lime wash over prepared surfaces of the ceiling complete all as specified and as directed by the Engr-in-charge.
M&L preparation of old decorated brick/concrete, plastered / un plastered surfaces of walls, pillars cornices etc by brooming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of cement base paint on the walls, pillars, cornices etc. complete all as specified and as directed by the Engr-in-charge.
M&L preparation of old decorated wall Surfaces, and applying one coat of exterior acrylic emulsion paint with roller on extrnal surfaces of any description, not otherwise, described, over 10cm width or girth complete all as specified and as directed by Engineer-in charge .
S & F 15mm bore cast copper alloy chromium plated stop valves fancy type with long shank and cup (concealed type), screwed down, high pressure with butterfly handle, scrwed both ends for iron pipe or for unions complete all as specified and as directed by the Engineer-in-Charge.
S & F shelf of PTMT 3 tier fixed with and including chromium plated brass screws and wooden/plastic cleats (minimum weight 300gms) complete all as specified and as directed by the Engineer-in-Charge.
S & F vitreous china urinal, half stall type white (excluding flushing cistern, flush pipe) but including brass chromium plated spreader, PVC waste pipe , providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, grating and union for discharge pipe. (exclusive of fixing supply pipe to flushing cistern, trap) complete all as specified and as directed by the Engineer-in-Charge.
Surface excavation not exceeding 30cm deep and averaging 15 cm deep, getting out in soft/loose soil complete all as specified and as directed by the Engineer-in-Charge.
Removal of excavated material to a distance not exc. 50 m and depositing at a level nexc 1.5 m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
Excavation over areas not exc 1.5 m in depth for foundation etc and getting out in soft/ loose soil complete all as specified and as directed by the Engineer-in-Charge.
M & L cutting into existing manholes for connecting new drain, making good to pipe 150 mm dia and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required complete all as specified and as directed by the Engineer-in-Charge.
M & L PCC 1:3:6 Type C2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M & L PCC 1:2:4 Type B1 using 20mm graded crushed stone aggregate as in surface channel and draines complete all as specified and as directed by the Engineer-in-Charge.
M & L extra for forming fair finish drain or channel 30 cm inner girth in cement concrete using extra cement including forms mould mitered/ stopped end etc complete all as specified and as directed by the Engineer-in-Charge.
M & L preparation of old decorated brick/concrete, plastered / un--plastered surfaces of walls by brooming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of white lime wash over prepared surfaces of wall, pillar, cornices complete all as specified and as directed by the Engineer-in-Charge.
Schedule 'B' Part-II (E/M itmes) Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, pendant, lamp holder, regulators, socket outlet, bulk head fittings, tube light fittings, calling bell etc and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall surfaces and on surface on ceiling surfaces and incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new cover plate over sunken box for housing the modular switches , modular socket outlets,modular fan regulators etc. and making smooth the disturbed surfaces as per existing for one light/fan/exhaust fan point controlled by one way switch, complete all as specified and as directed by Engineer-in-Charge. Note :- a) .All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid for separately .
Description same all as per item No. 145 but for One 3 pin, 5 Amps, socket outlet controlled by one switch on independent board, complete all as specified and as directed by Engineer-in-Charge.
Description same all as per item No. 145 but for One 3 pin 5 Amps socket outlet controlled by one switch on same board, complete all as specified and as directed by Engineer-in-Charge.
Material and labour for point wiring with 2.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall surfaces and on surface on ceiling surfaces and incuding provision of 2.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new cover plate over sunken box for housing the modular switches , modular socket outlets,modular fan regulators etc. and making smooth the disturbed surfaces as per existing for 3 pin, 15 Amp socket outlet point controlled by one way switch, complete all as specified and as directed by Engineer-in-Charge. Note :- a) .All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid for separately .
Supply and fix modular switch 1 module, single pole, one way 6 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fix modular switch 1 module, single pole, one way 16 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply & fix modular socket outlet 2/3 pin, 6amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply & fix modular socket outlet 2/3 pin, 6/16amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified and as directed by Engineer-in-Charge.
S&F of electronic Fan regulator modular 120 watt, 2 module, 230 volts , 50 Hz, AC supply suitable for ceiling fan any type/make/sweep complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings,with one PVC block of size 75mm x75mm complete all as specified and as directed by Engineer-in-Charge.
Supply and fix MCB single pole, 240 volt, 6 to 32 amps, 10 KA 'C' curve complete all as specified and as directed by Engineer-in-Charge.
Supply and fix as in repair MCB single pole, 240 volt, 6 to 32 amps, 10 KA 'C' curve complete all as specified and as directed by Engineer-in-Charge.
Supply and fix MCB single pole 63 Amps 240 volt, 10 KA, 'C' curve including removing old unserviceable MCB complete all as specified and as directed by the Engr-in-charge.
Supply and fix sheet metal MCB DBs 12 way with 200 Amps rated bus bar single pole and neutral with acrylic double door IP-43 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surface after removing old Unserviceable MCB DB complete all as specified and as directed by the Engineer-in-Charge.
M & L for dry sand as cushioning to cable 8 cm before laying cable in trenches and 15 cm after laying the cable and compacting, complete all as specified and as directed by the Engineer-in-Charge. Note:- for measurement, punned thickness shall be measured and paid.
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1 flat, size 250 mm x 150mm x 40mm complete all as specified and as directed by Engineer-in-Charge.
Taking down ceiling fan, sealing cable end, dismantling blades and applying one coat of painting on ceiling fans with synthetic enamel paint by spraying incl filling cavaties with filler after cleaning all dust etc.and reassembling the same complete all as specified and as directed by the Engineer-in-Charge.
Fixing only the ceiling fan and connecting up including provision of flexible cable cable 23/.0076 from ceiling rose or connector to fan complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix over and Low voltage release 1 module, 230 volts AC, suitable for single phase adjustabe from 170 volts to 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fix sheet metal MCB DB SPN 8 way with 200 Amps rated bus bar single pole and neutral with acrylic double door IP-43 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge.
Supply and fix as in repair over and Low voltage release 1 module, 230 volts AC, suitable for single phase adjustabe from 170 volts to 230 volts complete all as specified and as directed by Engineer-in-Charge.
S&F LED Bldg Security Light Fittings of capacity 40 -45 watt made up of die cast aluminium housing with black epoxy powder coating with cover heat resistance glass safety input voltage range 170 to 270 volts, industrial model with IP-65 protection and other connected accessories including service bracket of GI pipe 32 mm bore medium grade of length 0.9 mtr with MS clamps, bolts, nuts, and washers and suitable reducer for connecting fitting to GI pipe as required at site and two coats of synthetic enamel paint over one coat of red oxide primer on mild steel work and making electrical connection complete all as specified and as directed by the Engineer-in-Charge.
S&F light grade GI Tubing of size 40 mm dia for cable protection and fixed with clamp to pole and wall with nut, bolts and washers complete all as specified and as directed by the Engineer-in-Charge.
Supply and laying or fixing or passing through pipe 1100 volts grade heavy duty 2 core, 25 sq mm nominal cross section cable with PVC insulated aluminium conductor multistranded served with an inner sheathing of PVC tape and overall PVC sheathed in service connection complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix sheet metal enclosure Vertical triple pole & neutral(VTPN) 415 volts, 4 way with 200 Amp rated bus bar, IP-43 flush /surface mounting double door including adjustable MCCB TPN 100 Amp with beaking capacity 16 KA as incomer and MCBs as out going with suitable size MS cabinet 2mm thick duly grouted in solid block wall or on wooden board in and including lugs/thimbles duly crimped for connection including making smooth the disturbed surface including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge.
Supply and laying XLPE insulated, armoured heavy duty electric cable 25 sqmm cross sectional area, 3.5 core with multi stranded aluminium conductor, 1100 volts grade complete all as specified and as directed by the Engineer-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for laying of cables. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed by Engineer-in-Charge.
Returning, Filling in excavated soils including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer-in-Charge.
Removing excavated material to a distance not exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
S&F mirror light 9/12watt LED wall mounting fixture, one feet , aluminium housing compact & energy efficient epoxy powder coated CRCA light luminaire, connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing indoor decorative LED tube light fitting Batten type 1x18/20 W with opal diffuser, high efficient aluminium housing body in CRCA body suitable for LED tube, high efficient, AC 220-240 volts, 50 Hz and including 1x18/20 W LED tube rod luminaries (Warm/Cool as per site requirement) environment friendly, high efficient, T5 with aluminium extrusion heat sink connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix MCB SPN 32/40 Amps, 240 volt,10 KA, 'C' curve complete all as specified and as directed by the Engr-in-charge.
S&F single pole and neutral enclosure with a two pin and earth plug and socket 20 Amp complete with and including one single pole MCB.20 Amp, 10 KA, 'C' curve complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix as in repair MCB double pole, 240 volt, 20 amps, 10 KA 'C' curve complete all as specified and as directed by Engineer-in-Charge.
S & laying sub main wiring with two run of 4 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 4 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall and surface on ceiling in PVC conduit medium grade ISI marked of adequate size for housing the wires complete all as specified and as directed by the Engineer-in-Charge. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length.
S & laying sub main wiring with two run of 6 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 6 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall and surface on ceiling in PVC conduit medium grade ISI marked of adequate size for housing the wires complete all as specified and as directed by the Engineer-in-Charge. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length.
Material & labour as in repair earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised iron wire earth lead of 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron, earth wire protected by GI pipe 15mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm c/c with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge and earth testing on completion .
S&F LED lamp 9 watt retrofit , warm/cool lamp type suitable for fixing on batten/angular holders complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix sheet metal MCB DB SPN 4 way with 200 Amps rated bus bar single pole and neutral with acrylic double door IP-43 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces complete all as specified and as directed by the Engr-in-charge.
Supply and fix as in repair MCB SPN, 240 volt, 40 amps, 10 KA 'C' curve complete all as specified and as directed by Engineer-in-Charge.
Supply and fix exhaust fan 300 mm sweep, anti corrsive metal body, sturdy metal bird guard, copper wounded, double ball bearing, five star rating,1320 RPM,50HZ, 240 volts complete with dynamically balanced blade for vibration free rotation, split pin, clamp and fixing at site on and including MS fabricated base frame using flexible wire after making hole in wall as required at site and making good the disturbed surfaces and including making the electrical connection by using three core wire with colour code complete all as specified and as directed by Engineer-in-Charge.
S & F 15mm bore cast copper alloy chromium plated stop valves, screwed down, high pressure with butterfly handle, scrwed both ends for iron pipe or for unions complete all as specified and as directed by the Engineer-in-Charge.
S & F galvanised iron tubing 15mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge.
Supply & Fix Water heater (Geyser) storage type electric of capacity 25 Ltrs , BEE 5 Star rated, ABS body, metal tank with glasss lined coating, multiple heating option, shock safe plug, puf insulation, incoloy glass coated anode rod / copper heating element of capacity 2KW with ISI mark , adjustable knob for temp setting with minimum 8 Bar high working pressure, multi functional safety valve & whirl/Swirl flow technology, thermostat electronic type, thermal cutout capillary type complete including superior quality copper connection pipe heavy duty 15mm dia 450mm long, brass adopter for water connection with nikhel coated ISI marked with fastner, nut bolts, washers duly grouted, giving shape to hole as suitable and plastering including making good of disturbed surface as per existing surface, connecting to inlet and outlet valves, testing complete all as specified and as directed by Engineer-in-Charge. Note :- Warranty certifcate to be produced by the Contractor from OEM for the following components before processing the bill. a) for Product - 02 Years b) for Heating element - 03 Years c) for metal tank - 07 Years
S & F copper connection heavy duty 15 mm bore nikhel coated, 450 mm long with brass adopter for water connection with complete all as specified and as directed by Engineer-in-Charge.
Supply & fix chromium plated Brass wall mixer, external fixed type for hot and cold water supply including required fixtures and fittings suitable for 15mm bore pipe complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing wall mounting LED light (bed side) with acrylic glass cover, AC, 220-230 volts, 50 Hz and fixed on wall with plastic gutties, brass chromium plated screws with and including LED 12 watt bulb complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing LED flat panel 2' x 2' size fully difused surface/ recess mounted fitting (grid/ gypsum type) 36-40 watt , 5700K, warm/cool white with powder coating and CRCA front cover including frame with provision of PVC flexible copper conductor cable to light fitting as in repair complete all as specified and as directed by the Engr-in-charge.
Durga Enterprises
Sham Sunder Bansal
M/s Vridhi Construction Co.
Swami Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .