Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.9 CrAccepted-AOC | ₹3.9 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹4.3 Cr+₹36.5 L (9.38%)Rejected-Finance | ₹4.3 Cr+₹36.5 L (9.38%) | L2 | Rejected-Finance High bid value |
| 3 | L3₹4.3 Cr+₹45.6 L (11.7%)Rejected-Finance B 87 SHAM NAGAR KHAYALA ROAD NEW DELHI 110018 | NEW DELHI | NEW DELHI | DELHI | 110018 | ₹4.3 Cr+₹45.6 L (11.7%) | L3 | Rejected-Finance High bid value |
| 4 | L4₹5.0 Cr+₹1.1 Cr (29.3%)Rejected-Finance B 22 HQ ADG NEI GUWAHATI BABULAR BAZAAR TINSUKIA 786125 ASSAM | TINSUKIA | ASSAM | 786125 | ₹5.0 Cr+₹1.1 Cr (29.3%) | L4 | Rejected-Finance High bid value |
| 5 | L5₹5.1 Cr+₹1.2 Cr (30.4%)Rejected-Finance | ₹5.1 Cr+₹1.2 Cr (30.4%) | L5 | Rejected-Finance High bid value |
Tender Value
₹4.4 Cr
EMD Value
₹5.2 L
Closing Date
4 Mar 2023, 6:00 pmClosed
HQ Chief Engineer Shillong Zone,S E Falls Shillong
HQ Chief Engineer Shillong Zone,S E Falls Shillong, Pin-793011
PROVISION OF CERTAIN WORKS SERVICES FOR WATER AND ELECTRICAL SUPPLY SYSTEM AND CERTAIN STRUCTURES REHABILITATION WORKS AT MASIMPUR MIL STN UNDER GE SILCHAR(PARA 35 AND 38 WORKS OF DWP)
2023_MES_580467_1
CESZ/MSP OF 2022-2023
Open Tender
Civil Works
Item Rate
180 days
Silchar
AS per NIT / Tender Documents
2 documents required · 2 mandatory
₹2,000
GE Silchar
₹5.2 L
Yes
10 Mar 2023
11 Feb 2023
6 Mar 2023
11 Feb 2023
4 Mar 2023
20 Feb 2023
13 Feb 2023 - 15 Feb 2023
Amount
NOTE (Applicable for all items):- The bidders/contractors are advised to read tender document & all corrigendum/ amendments and General conditions of contracts before entrying/quoting the rates. SCHEDULE 'A' BOQ
Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 but not exc 1.5m in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-in?charge complete all as specified and directed by Engineer-in-Charge.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc., n exc. 1.5m high from base complete all as specified and directed by Engineer-in-Charge.
Rough excavation not exceeding 1.5 m deep and getting out in Soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exceeding 1.50 m wide and not exceeding 1.50 m in depth for foundations,etc or for shafts, wells, cesspits, manholes, pier holes etc. not exceeding 10 Sqm on plan and not exceeding 1.50 m in depth and getting out in soft/loose soil.
Excavation in trenches not exceeding 1.50 m wide and exceeding 1.50 m in depth and not exc 3.0 m in depth for foundations,etc or for shafts, wells, cesspits, manholes, pier holes etc. not exceeding 10 Sqm on plan and exceeding 1.50 m in depth and not exc 3.0 m in depth and getting out in soft/loose soil.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm watering, and removing surplus soil to a distance n exc 50 m and making good surface
Excavating over areas, n exc 1.5 m deep and getting out in soft/loose soil complete all as specified and directed.
Excavating over areas, exc 1.5 m but not exc 3.0 m deep and getting out in any type of soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. as in soft/loose soil complete all as specified and directed.
Removing excavated material (soil) not exceeding 50 m and depositing where directed at a level n. exc. 1.50 m above the starting point complete all as specified and as directed.
Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed complete all as specified and directed.
M&L for cement concrete in foundation filling and mass concrete type D2 1:4:8 (40mm graded aggregate) complete all as specified and as directed.
M&L for cement concrete in foundation filling and mass concrete type C2 1:3:6 (40mm graded aggregate) complete all as specified and as directed.
M&L for Hardcore (Broken stone or boulders) of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface, complete all as specified and as directed
M&L Formwork to sides of concrete ( rough finished flat surfaces ) foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed.
M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions in rough finished surfaces of concrete (Square, rectangular or polyonal) complete all as specified and directed.
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc for rough finished surfaces of concrete (flat) complete all as specifed and directed.
M&L for Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete rail?ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specifed and directed.
M&L for Formwork to faces of walls (Rough finished flat surfaces ), retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter complete all as specifed and directed.
M&L for Formwork to soffits of suspended slabs(Rough finished flat surfaces )such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specifed and directed.
M&L mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
M&L mild steel TMT bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
M&L for Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
M&L for RCC M-25 design mix (20mm graded stone Aggregates) in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M&L for RCC M-25 design mix (20mm graded stone Aggregates) in Columns, pillars, piers, posts and struts, etc.; complete all as specified and as directed.
M&L for RCC M-25 design mix (20mm graded stone Aggregates) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
M&L for RCC M-25 design mix (20mm graded stone Aggregates) in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M&L for RCC M-25 design mix (20mm graded stone Aggregates) in Walls, retaining walls,basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and as directed.
M&L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed.
M&L for laying of 250mm spread thickness grannular sub base (GSB) of grade I as per table 400-2 of MORTH, IRC specification, in two layers each of 125mm thick laid rolled and compacted to required gradient and camber with 8 to 10 tonn power roller and vibratory roller complete all as specified and as directed.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed. complete all as specified and directed
M & L rendering 5mm thick on fair faces of new RCC/concrete surfaces in CM (1:3) finished fair and even complete all as specified and directed.
M&L rendering 5mm thick in CM(1:3) of column surfaces & mixed with water proofing compound finished even and smooth without using extra cement complete all as specified and directedd.(Cost of WPC included in quoted rate)
M&L for rendering 15mm thick in CM 1:4 on brick walls, finished fair & even complete all as specified and as directed.
M&L for 125mm thick PCC (1:3:6), C2 using 40mm graded stone aggregates as in sub base complete all as specified and as directed.
M&L for PCC, type B2 1:2:4 (40mm graded aggregate) as in foundation, sub base, filling and mass concrete complete all as specified and as directed.
Scarifying or picking gravelled, macadam or bituminous macadam surfaces in area exc 400 sqm, Exc 50 mm and n exc 100 mm deep complete all as specified and directed.
M&L for 100mm thick, PCC 1:3:6 type C-2(using 40mm graded aggregate) as in floor, sub base and base course etc complete all as specified and as directed.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. Note :- Only compacted thickness shall be considered for measurement purposes.
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade (with grey cement and no pigment) complete all as specified and as directed.
M&L for PCC (1:2:4) type B-1(using 20mm graded stone aggregate) as in coping/benching, slightly rounded or chamfered angles and throating, etc incl necessary formwork complete all as specified and directed.
M&L for PCC (1:2:4) type B-2(using 40mm graded stone aggregate) as in bed to drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested for 450mm dia pipes complete all as specified and as directed.
M&L for 450mm dia Reinforced concrete pipes, class NP3, laid and jointed complete with collars complete all as specified and as directed.
M&L for Walling of random rubble, coursed, well bonded, bedded and solidly hearted built in cement mortar (1:6) with lime/sand stone and PCC (1:3:6) type C1 precast bond stone (in lieu of stone bond stone) set in cement mortar(1:4) complete all as specified. Note's: (i)Pre-cast PCC bond stone shall be measured and paid separately against Srl Item no 46 of this BOQ here-in-after. (ii) RR masonry will be measured after deducting PCC bond stone
M&L for precast PCC bond stone of (1:3:6 Type C-1) for retaining wall, abutmants and similar works(set in cement mortar 1:4) including necessary form work complete all as specified and directed.
M&L for raised pointing to random rubble masonry, coursed or uncouresd in CM (1:3) complete all as specified and as directed.
M&L Hand packing with broken stone or boulders (any thickness) at back of walls over arches etc. and raising (or lowering) to the required level complete all as specified and as directed.
M&L 110mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specifed and directed
M&L for preparation of newly plastered surfaces and applying three coats of white wash on wall complete all as specified and as directed
M&L for Framed work as in steel gate framed and side hung incl pintle hinges, stops, hand made sliding bolt monkey tail bolts etc.complete all as specified and as directed.
M&L for Mild Steel angle, flat works as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc, flat iron fillets(for securing wire mesh etc) including all necessary drilling, bolting or riveting etc. conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
M&L for Mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips conforming to Fe.410 W.Gde-E-250 quality-A complete all as specified and as directed.
M&L for 10mm dia Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified and as directed.
Supply only Chain link MS galvanised fencing, any size or type as decided by GE complete all as specified and as directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire (Size of mess 100 x 100mm, or as decided by GE) complete all as specified and as directed.
M&L for preparation of new or previously untreated steel surface of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
M&L for prepration of new or previously untreated steel surface of any description, not exc 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Dismantling of ACSR or AAC conductors(any size), jumper from overhead line, removing unservicable material from site of work for disposal in credit complete all as specifed and directed
Dismantling unserviceable cross-arms of M.S. channel or angle sections etc. complete all as specified and as directed.
Dismantling unserviceable insulators any type, any size complete complete all as specified and as directed.
Dismantling of earth wire/craddle/stay/service distributon feeder complete all as specified and as directed.
M&L for Stay assembly complete with accessories as shown in electrical plate No. 1 (loop type insulator, stay clamps) complete all as specified and as directed. Note:- Excavation and concrete shall be measured and paid separately
M&L for loop type insulator, vitreous porcelain, white, brown or green, small size with overall dimension 90 x 140mm clearance of hole 25.5mm complete all as specified and as directed.
Design, engineering, supply, installation, testing & commissioning of 1.1KV Aerial Bunched Cable line on existing poles of size 3 core x 16sqmm + 1 core x 25sqmm consisting of all accessories such as MS flat, LT insulators, GI earth spikes, GI earth wires, suspension clamp with pole bracket and steel strap, dead end/anchor clamp with pole bracket and steel strap, SMC service main distribution box 415V, 250-140A with copper bus bar for LT AB cable on requirement basis, insulation piercing connectors, cable end cap etc as per site complete all as specified and as directed.
All as per Srl Item No 65 but size 3 Core x 35 Sqmm + 1 Core x 25 Sqmm.
All as per Srl Item No 65 but size 3 Core x 50 Sqmm + 1 Core x 35 Sqmm.
All as per Srl Item No 65 but size 3 Core x 70 Sqmm + 1 Core x 50 Sqmm.
All as per Srl Item No 65 but size 3 Core x 95 Sqmm + 1 Core x 70 Sqmm.
All as per Srl Item No 65 but size 3 Core x 120 Sqmm + 1 Core x 95 Sqmm.
All as per Srl Item No 65 but size 3 Core x 150 Sqmm + 1 Core x 120 Sqmm. Note for Srl Item No 65 to 71 :- (i) Three run of XLPE insulated 1.1 KV grade AB single core cable along with one run of bare aluminium messenger conductor shall be considered as 01 RM for measurement. (ii) Contractor shall submit the design details alongwith sag calculation etc for approval by Accepting Officer before commencement of work. (iii) Successful commissioning of the entire system shall be the responsibility of the contractor. All items required for successful commissioning shall deemed to be incuded in the quoted rate. Nothing extra shall be paid on this account.
Design, engineering, supply, installation, testing & commissioning of 11KV Aerial Bunched Cable line on existing poles of size 3 core x 95sqmm + 1 core x 70sqmm consisting of all accessories such as MS channel, MS angle, MS flat, HT insulators, termination box with provision of appropriate earthing system, suspension clamp, anchor clamp, eye hook, cable end cap, suitable tapping arrangement, joints & jointing material etc complete as per site complete all as specified and as directed. Note :- (i) Three run of XLPE insulated 11 KV grade AB single core cable along with one run of bare aluminium messenger conductor shall be considered as 01 RM for measurement. (ii) Contractor shall submit the design details alongwith sag calculation etc for approval by Accepting Officer before commencement of work. (iii) Successful commissioning of the entire system shall be the responsibility of the contractor. All items required for successful commissioning shall deemed to be incuded in the quoted rate. Nothing extra shall be paid on this account.
Supply laying / installation testing and commissioning of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 95 sqmm 3 Core complete all as specified and directed.
Supply laying / installation testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 240 sqmm 3.5 Core complete all as specified and directed.
M&L for Steel Tubular Swaged Poles Type 410-SP-31 (09 Metre long) including cast iron base plate, finial taper plug, cap, mild steel bolts, screws, etc. including applying two coats of black bituminous paint internally and externally upto planting depth and applying two coats of aluminium paint over a coat of aluminium primer (externally from top of RCC copping) including painting of black & white alternate strip of 30cm each externally from ground level upto 1.2m and writing MES Pole No. with synthetic enamel paint (first grade quality) complete all as specified directed by Engr-in-Charge. Note:- (a) Earthwork and PCC will be measured and paid separately (b) Volume occupied by Steel Pole shall be deducted to derive the quantity of PCC.
M&L for Steel Tubular Swaged Poles Type 410-SP-55 (11 Metre long) including cast iron base plate, finial taper plug, cap, mild steel bolts, screws, etc. including applying two coats of black bituminous paint internally and externally upto planting depth and applying two coats of aluminium paint over a coat of aluminium primer (externally from top of RCC copping) including painting of black & white alternate strip of 30cm each externally from ground level upto 1.2m and writing MES Pole No. with synthetic enamel paint (first grade quality) complete all as specified directed by Engr-in-Charge. Note:- (a) Earthwork and PCC will be measured and paid separately (b) Volume occupied by Steel Pole shall be deducted to derive the quantity of PCC.
Supply, install , testing and commissioning of outdoor LT distribution feeder pillar box (CPRI approved and with certification by ERDA for IP 65) of 1100mm x 1000mm x 350mm size, factory made (tested as per IS) totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear, made out of 3.15mm thick CRCA sheet duly fabricated and having proper front and rear locking arrangement duly powder coated and aluminium bus bar of suitable Amps, 415 volts, 50 Hz, 3 phase and 4 wired system with the following items including supply and fixing with MS channel 75mm x 40mm x 5mm duly painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer for fixing the feeder piller box to PCC foundation complete all as specified and directed :- In coming :- (i) MCCB 4 pole, 415 volts AC grade, 320 Amps, 25 kA, Icu = 100%Ics : - 01 No (ii) Danger notice plate made up of 1.6mm thick steel sheet. (iii) Multi function meter -1 No (iv) Phase indicator lamps (RYB)-1 set Out going :- (i) MCCB 4 pole, 415 volts AC grade, 100 Amps, 16 kA, Icu = 100%Ics : - 03 Nos (ii) MCCB 4 pole, 415 volts AC grade, 63 Amps, 16 kA, Icu = 100%Ics : - 03 Nos (iii) Multi function meter -1 No (iv) Phase indicator lamps (RYB)-1 set
Supply, install , testing and commissioning of outdoor LT distribution feeder pillar box (CPRI approved and with certification by ERDA for IP 65) of 1100mm x 1000mm x 350mm size, factory made (tested as per IS) totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear, made out of 3.15mm thick CRCA sheet duly fabricated and having proper front and rear locking arrangement duly powder coated and aluminium bus bar of suitable Amps, 415 volts, 50 Hz, 3 phase and 4 wired system with the following items including supply and fixing with MS channel 75mm x 40mm x 5mm duly painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer for fixing the feeder piller box to PCC foundation complete all as specified and directed :- In coming :- (i) MCCB 4 pole, 415 volts AC grade, 400 Amps, 36 kA, Icu = 100%Ics : - 01 No (ii) Danger notice plate made up of 1.6mm thick steel sheet. (iii) Multi function meter -1 No (iv) Phase indicator lamps (RYB)-1 set Out going :- (i) MCCB 4 pole, 415 volts AC grade, 250 Amps, 25 kA, Icu = 100%Ics : - 02 Nos (ii) MCCB 4 pole, 415 volts AC grade, 100 Amps, 16 kA, Icu = 100%Ics : - 03 Nos (iii) MCCB 4 pole, 415 volts AC grade, 63 Amps, 16 kA, Icu = 100%Ics : - 01 Nos (iii) Multi function meter -1 No (iv) Phase indicator lamps (RYB)-1 set
Supply, install , testing and commissioning of outdoor LT distribution feeder pillar box (CPRI approved and with certification by ERDA for IP 65) of 1100mm x 1000mm x 350mm size, factory made (tested as per IS) totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear, made out of 3.15mm thick CRCA sheet duly fabricated and having proper front and rear locking arrangement duly powder coated and aluminium bus bar of suitable Amps, 415 volts, 50 Hz, 3 phase and 4 wired system with the following items including supply and fixing with MS channel 75mm x 40mm x 5mm duly painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer for fixing the feeder piller box to PCC foundation complete all as specified and directed :- In coming :- (i) MCCB 4 pole, 415 volts AC grade, 400 Amps, 36 kA, Icu = 100%Ics : - 01 No (ii) Danger notice plate made up of 1.6mm thick steel sheet. (iii) Multi function meter -1 No (iv) Phase indicator lamps (RYB)-1 set Out going :- (i) MCCB 4 pole, 415 volts AC grade, 160 Amps, 16 kA, Icu = 100%Ics : - 03 Nos (ii) MCCB 4 pole, 415 volts AC grade, 125 Amps, 16 kA, Icu = 100%Ics : - 01 Nos (iii) MCCB 4 pole, 415 volts AC grade, 100 Amps, 16 kA, Icu = 100%Ics : - 01Nos (iv) MCCB 4 pole, 415 volts AC grade, 63 Amps, 16 kA, Icu = 100%Ics : - 02 Nos (v) Multi function meter -1 No (vi) Phase indicator lamps (RYB)-1 set (vii) Off load changeover switch-AC 21 (Side handle) 400 Amp 4 pole, 415 Volts AC, 50 Hz : - 01 No
Material & Labour for earthing with galvanised steel earth plate electrode of size 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI strip 25x4mm as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI light grade earth lead protection pipe, RCC pit cover made out of 1:2:4 concrete and 8mm dia TMT bar, 100mm centre to centre with lifting handle of 10mm dia TMT bar, wire, copper lugs etc mesh, chorcoal and common salt in alternatee layer complete all as specified and directed by Engr-in-Charge.
Material & Labour for earthing with galvanised steel earth plate electrode of size 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI strip 32x6 mm as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI light grade earth lead protection pipe, RCC pit cover made out of 1:2:4 concrete and 8mm dia TMT bar, 100mm centre to centre with lifting handle of 10mm dia TMT bar, wire, copper lugs etc mesh, chorcoal and common salt in alternatee layer complete all as specified and directed by Engr-in-Charge.
Taking out existing HT UG XLPE cable, 11000 V of size 95 sqmm 3 core and relaying the same at existing/new location complete all as specified and directed. Note: Excavation, earth work shall be measured and paid separately under respective items.
M&L for Sub class ‘B’ old size well burnt brick laid flat in trenches over the cable for protection of cable complete all as specified and as directed.
Supply and spread dry fine sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. Note: Thickness of sand cushioning after punning down will be measured and paid.
M&L for PCC (1:3:6), Type C1 (using 20mm graded stone aggregate) for electric pole, chamfered on edges complete all as specified and directed.
M & L for heat shrinkable straight through joints complete for making joints suitable for LT cable of size 185 - 240 sqmm 3.5 core complete all as specified and directed.
M & L for heat shrinkable indoor termination complete for making joints suitable for LT cable of size 185 - 240 sqmm 3.5 core complete all as specified and directed.
M & L for heat shrinkable outdoor termination complete for making joints suitable for LT cable of size 185 - 240 sqmm 3.5 core complete all as specified and directed.
M & L for cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm 3 core complete all as specified and directed.
M & L for cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm 3 core complete all as specified and directed.
M & L for cable jointing kit for 11 KV (earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm 3 core complete all as specified and directed.
M&L for heat shrinkable outdoor termination complete for making joints suitable for 11 KV aerial bunched cable of size 95 - 120 sqmm 3 core complete all as specified and directed.
M&L for heat shrinkable straight through complete for making joints suitable for 11 KV aerial bunched cable of size 95 - 120 sqmm 3 core complete all as specified and directed.
M&L for boring of hole underneath road/hardstanding/pavement by manual horizontal boring for crossing of cable without cutting the top surface and inserting HDPE pipe of dia 110mm bore complete all as specified and directed. Note: Cost of 110 mm bore HDPE pipe is deemed included in unit rate quoted by the contractor
Supply, installation, testing and commissioning Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity 120 KVAR including APFC relay, Capacitor of type heavy duty cylindrical, contactors and control wiring with copper wire in outdoor type panel board with IP 54 protection made out of 2 mm thick CRCA sheet (CPRI approved) including cooling fan, copper bus-bar of 600 Amp capacity etc with all necessary protection etc and 250 Amp capacity MCCB 4-Pole breaking capacity 36kA, Ics=100%Icu as incommer complete all as specified and directed. The panel shall be fixed with angle iron frame made out of angle 50 x 50x 6mm, embedded 350mm below the ground level in PCC 1:2:4, Type B-1 using 20mm grade stone aggregate, min 750mm above the ground level complete all as specified and as directed incl following accessories :- MATERIALS LIST FOR 120KVAR APFC PANEL BOARD INCOMER: (i) 250A, 4P, 36KA, MCCB, Ics=100% Icu - 1 No. (ii) Spreader Link For 250A, 4P, MCCB - 1 Set. (iii) Extended rotary handle for 250A, 4P, MCCB - 1 No. (iv) Digital VAF meter, Cl-1 - 1 No. (v) CT 100/5A, Tape wounded , Cl-1 - 3 Nos. (vi) CT 100/5A, Tape wounded, Cl-1 in main Panel before load - 1 No. (vii) LED type Indication Lamp R,Y,B - 3 Nos. (viii) MCB 6A, SP, "C" Series - 6 Nos Contd.to Srl Item No....96
Taking down/out existing RMU with all accessories carefully from the platform including disconnecting from HT/LT side and shifting the same to the new platform and making connection to HT/LT side & testing complete all as specified and as directed.
Taking down/out existing LT Panel with all accessories carefully from the platform including disconnecting from HT/LT side and shifting the same to the new platform and making connection to HT/LT side & testing complete all as specified and as directed
M&L for triple pole mechanically operated air break isolator (GOD), vertical mounting, rotating type, mounted on insulators and steel frame with operating mechanism worked from ground level complete in all respect such as gun metal moving contacts and spring loaded gun metal fixed jaws, knife copper jumper strip, etc. suitable for 11000Volts grade, with 9 insulators of rating upto 400Amps complete all as specified and as directed.
M&L for triple pole mechanically operated air break isolator (GOD), vertical mounting, rotating type, mounted on insulators and steel frame with operating mechanism worked from ground level complete in all respect such as gun metal moving contacts and spring loaded gun metal fixed jaws, knife copper jumper strip, etc. suitable for 11000 Volts grade, with 9 insulators of rating upto 200 Amps complete all as specified and as directed
Disconnection of transformer of capacity 100-315 KVA from HT/LT side and re-installing on raised platform/trolley and making connection to HT/LT side including testing complete all as specified and directed.
Supply, installation, testing and commissioning of 11 KV Compact Sub Station with non extensible RMU consisting of the following:- (A) HT SWITCHGEAR :- (i) 11 KV 630 Amps 21 kA/3 sec. Non-extensible RMU Compact switchgear consiting of (DV) 01 No Direct Module for incoming cable and 01 No Fixed Motoriised Vacuum Circuit Breaker in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. Interconnection between HT switchgear and primary of transformer shall be done through 1C x 3R x 95 sqmm Al unarmoured XLPE cable as per Annexure enclosed- Qty: 01 No (ii) Protection Relay: Aux powered relay (50,50N,51,51N). Qty: 01 Set (iii) Protection CT-40/1 A, 2.5VA, 5P10 (Make - Ericon/ECS/Pragati/Eq). Qty: 01 Set (iv) Manometer. Qty: 01 No (v) Voltage Presence Indications for each Module. Qty: 02 Set (vi) Mechanical ON/OFF/TRIP Indications for Breaker on front mimic. Qty: 01 Set (vii) Operating Handle. Qty: 01 No (viii) 24V DC Battery & Charger for Motor Operation of VCB. Qty: 01 Set Note: (i) RMU must have provision of Gas filling at site, in case there is some leakage of the gas. (ii) Vacuum interrupter must be same make as RMU. (iii) Cable bushing must be replaceable at site only. Contd to Item No ..103
Contd of Item No 102 (B) TRANSFORMER :- (i) Transformer 250 KVA 11/0.415KV, Dyn11, ONAN, Copper wound, Hermetically Sealed Transformer with corrugated tank, TOP Bushings on HV and on LV side, Temp Rise: 35/40 Degree Centigrade. Over ambient temp of 50 Degree Centigrade (Oil/Winding), Off circuit Tappings +5% to -5% @ 2.5% per step, Losses (As per IS1180 level 1/star 1), Impedance - 4% (subjected to IS tolerance). -Qty: 01 No (ii) Oil Temperature Indicator with alarm and trip contact. Qty: 01 No (iii) Winding Temperature Indicator with alarm and trip contact. Qty: 01 No (C) LVS LT Panel with 400A Aluminium Busbar, construction with CRCA /mm thickness sheet, Form 2B, Ingress Protection > IP4X, consisting of following:- (i) 400 Amps, 415 V, 36 KA 4P Fixed Manual Molded Case Circuit Breaker with microprocessor based over current, short circuit and earth fault protection - Qty: 01 No (D) OUTDOOR ENCLOSURE :- (i) Outdoor type enclosure having construction of Galvanised Sheet Steel of thickness 2mm for Load Bearing Member and 1.5mm for Non Load Bearing members with HRCA baseframe. The enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP34 degree of protection for Transformer compartment. The enclosure exterior shall be Powder Paint (Colour Light Gray & D.A.Gray)> Each compartment will be provided with the door and pad locking arrangement. The compartment illumination lamp with door operated switch shall be provided for MV & LV compartment and switch operated lamp in transformer compartment with bulket arrangement. Qty: 01 Set Contd to Item No 104
Contd of Item No 103 (E) INTERCONNECTION & EARTHING:- (i) Interconnection between HT switchgear RMU and Transformer HT bushing inside CSS enclosure using 1Cx3Rx95sqmm XLPE Single Core Aluminium cable. Qty - 01 Set (ii) Interconnection between Transformer & LT switch gear using Aluminium Busbars. Qty: 01 Set (iii) Internal earthing connections by using 50x6mm GI strips including Transformer neutral. Qty: 01 Set
Taking out/dismantling very carefully of centrifugal pumping set coupled with 75HP induction motor of capacity 21,000 GPH after disconnecting all electrical and pipe connection and removing of all nut, bolts, foundation channel, etc from existing foundation and refixing & testing the same to the new position connecting all electrical cables, foundation channel alongwith new nut-bolts, vibration pad, suction and discharge pipes and complete testing including necessary two coats of painting with synthetic enamelled paint after preparation of surface complete all as specified and directed.
Taking down old U/s copper wire with lugs all as directed.
S&F copper wire multistranded, FR PVC insulated single core of size 35 sqmm drawn through galvanised steel flexible conduit with PVC coating of size 40mm complete all as specified and directed.
S&F Bimetallic (Bronze) lugs of size 35/50 sqmm complete all as specified and directed.
S&F galvanised steel flexible conduit with PVC coating of size 40mm complete all as specified and directed.
Taking up 200mm dia cast iron / Ductile Iron water mains (including all fittings), with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and directed.
Taking up 150mm dia cast iron / Ductile Iron water mains (including all fittings), with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and directed.
Supply and fix centrifugally cast(Spun) Ductile Iron Pressure Pipe with flanged end , class K-9 conforming to IS : 8329/2000 including material and labour for flanged joints with centrifugally applied inside cement mortar lining with sulphur resistant cement and external metallic Zinc coating with finishing layer of black bitumen coating on external surfaces in any length laid in trenches complete all as specified and directed of size 200 mm nominal bore.
Supply and fix centrifugally cast(Spun) Ductile Iron Pressure Pipe with flanged end , class K-9 conforming to IS : 8329/2000 including material and labour for flanged joints with centrifugally applied inside cement mortar lining with sulpher resistant cement and external metallic Zinc coating with finishing layer of black bitumen coating on external surfaces in any length laid in trenches complete all as specified and directed of size 150 mm nominal bore.
Taking down unservicable sluice valve of 200mm dia size complete all as specified and directed
Taking down unservicable sluice valve of 150mm dia size complete all as specified and directed
Supply & Fix 200mm dia Sluice Valve Class PN 1.6 , both end flanged with S/S spindle with nut ISI marked complete with hand wheel nuts, bolts, washers & rubber gasket etc complete all as specified and directed:complete all as specified and directed.
Supply & Fix 150mm dia Sluice Valve Class PN 1.6 , both end flanged with S/S spindle with nut ISI marked complete with hand wheel nuts, bolts, washers & rubber gasket etc complete all as specified and directed:complete all as specified and directed.
Taking down foot valve upto size 150mm dia complete all as specified and directed.
S&F Cast Iron Foot Valve of size 150mm (6'') dia conforming to IS-4038 complete all as specified and directed.
Taking down Non return valve upto size 150mm dia complete all as specified and directed.
S&F cast iron Non return valve of size 150mm dia complete all as specified and directed.
M&L for Ductile Iron special and fittings PN 1.6 upto 200mm bore as per IS for flanged end pipes for water mains / branches lines such as bends(any type radius and angle) tapers any type (straight, bend, incressing, decressing or double socket etc) tee pieces, single branch, Y junction, double branch, cross coller, caps & plugs including connecting pieces one end flanged and other socket or spigot and bell mouth pices suitable for run lead joint, run lead up to 200mm bore complete all as specified and directed.
M&L for jointing the pump outlet to existing pipe line of any size with suitable size of fittings complete all as specified and directed (Note: Fittings & fixtures for pipe connection shall be deemed to be included in quoted rate)
M&L for brick masonary valve pit internal dimension 3000x3000x1000 mm incl all allied works such as necessary excavation, earth work, plastering with 15 mm thick in cement mortar (1:4) brickwork built in cement mortar with sub class 'B' brick PCC coping with 1:3:6 type C2 using 20mm graded cement mortar also include welding of MS angle iron, 3.15mm thick MS sheet cover, handle and locking arrangement and painting of all metal part colour alongwith 1 No lock 50mm all as specified and directed. Note:- The cost shall be inclusive of all items of work required for the execution and entire completion of this item and nothing extra shall be paid separately in any other item of BOQ
M&L for 4 pole structure on 11-meter steel tubular pole consisting of pole with anti-climbing device, PCC foundation & suitable cross arms as per TD Drawings etc. for one incoming and three outgoing complete all as specified and directed
Supply of heavy duty trolley of mild steel with four wheels and one spare wheel, pneumatic with tubeless type, front wheels to be made moveable co?axial type, 450mm ground clearance by hydraulic jack, toe air filling pump, four wheel drum brake system spring loaded draw bar liquid based suspension system provn for idling screw jack 04 Nos for levelling transformer, towing arrangement for Eicher Vehicle, size of trolley as per OEM design for 250 KVA Transformer & suitable to carry a load upto 7.5 Tones alongwith 600mm outer guard shall be made of chain link of aparature 25mm x 25mm with MS post & 600mm spacing between Transformer and outer guard and overhead shed, extra space for LT cable earthing connection suitable for body complete all as specified and directed by Engr-in-Charge. Note: Trolley design to be got approved by contractor from GE before procurement
M&L for potable earthing kit comprising of copper bonded earth rod alongwith 16sqmm single core PVC insulated cable of length 15m complete all as specified and directed.
N.V.ENGINEERING
New Era Engineers
Garg Brothers
BHOWMICK ENTERPRISES INDIA
M/S R. K. INDUSTRIES
Flint India
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .