Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.6 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹39.1 L+₹1.3 L (3.52%)Rejected-Finance | L2 | Rejected-Finance Not the lowest bidder | |
| 3 | L3₹41.9 L+₹4.1 L (10.9%)Rejected-Finance | L3 | Rejected-Finance Not the lowest bidder | |
| 4 | L4₹42.1 L+₹4.3 L (11.3%)Rejected-Finance | L4 | Rejected-Finance Not the lowest bidder | |
| 5 | L5₹42.5 L+₹4.8 L (12.6%)Rejected-Finance | L5 | Rejected-Finance Not the lowest bidder |
Tender Value
₹34.9 L
EMD Value
₹69,800
Closing Date
28 Jul 2022, 6:00 pmClosed
GE Barrackpore
Office of the Garrison Engineer Barrackpore, Kolkata-700120
PROVN OF PARKING SHED AT JCO/OR ACCN, SENTRY POST NEAR A COY AND B COY COOK HOUSE, SENTRY POST, SECURITY LIGHT AREA BEHIND OFFRS AND JCO MESS AND 5 KVA ONLINE UPS WITH BATTERY OF DET SIGN CENTRE AT KANCHRAPARA UNDER GE BARRACKPORE
2022_MES_532012_1
8654/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Barrackpore
Refer to tender documents
3 documents required · 3 mandatory
₹500
GE Barrackpore
₹69,800
Yes
3 Sept 2022
18 Jun 2022
30 Jul 2022
18 Jun 2022
28 Jul 2022
2 Jul 2022
Amount
PART-I Surface dressing in soft /loose soil not exceeding 15 cm deep (averaging 7.50 cm deep) complete all as specified and directed.
Excavating in post holes (or similar holes) in soft /loose soil each not exceeding 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering and removing surplus soil to a distance not exceeding 50m and making good the surface complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation or for shafts, well, cesspits, pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches exceeding 1.5 mtr wide and not exceeding 3.0 mtr in depth for foundation or for shafts, well, cesspits, pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading leveling, watering and well ramming in layers not exceeding 25cm, soil complete all as specified and directed.
Removing surplus excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting points in soft/loose soil complete all as specified and directed.
M&L for filling of sand as in subgrade under footings including ramming and watering as required complete all as specified and directed.
M&L for broken brick hardcore of gauge not exceeding 63mm, deposited spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in post hole filling, foundation filling and mass concrete complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in coping, bed plates, kerbs or mud stops, top of chajjas, basement for water tank etc rounded or chamfered on edges including necessary form work finishing the surface even and fair with using extra cement complete all as specified and directed.
M&L for PCC (1:3:6) type C1 (using 20mm graded stone aggregate) s in back filling of pressed steel door frames etc complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) used as in bed blocks for fixing of hold fast and like etc including necessary form work complete all as specified and directed.
M&L for RCC (nominal mix) (1:1.5:3) type A1 (using 20mm graded crushed stone aggregate) used as in slab supported on walls, beams and columns in floors, roofs, landing, balconies, canopies, deck slabs and in shelves and like etc complete all as specified and directed.
M&L for RCC (nominal mix) (1:1.5:3) type A1 (using 20mm graded crushed stone aggregate) as in foundations including rafts, footings, foundation beam, plinth beams, bases for columns etc , basement slabs, under-reamed piles and mass concrete etc complete all as specified and directed.
M&L for RCC (nominal mix) (1:1.5:3) type A1 (using 20mm graded crushed stone aggregate) as in column, pillar, piers, post and struts etc complete all as specified and directed.
M&L for RCC (nominal mix) (1:1.5:3) type A1 (using 20mm graded crushed stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and directed.
M&L for RCC (nominal mix) (1:1.5:3) type A1 (using 20mm graded crushed stone aggregates) as in chajjas complete all as specified and directed.
Providing form work to sides of concrete foundation, footing, base of column, raft & plinth beam for flat, rough finish surface of concrete complete all as specified and directed.
Providing form work to sides of pillar, posts, struts, piers, columns and stanchions for flat, rough finish surface of concrete complete all as specified and directed.
Providing form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc also splays between floors and beams etc for flat, rough finish surface of concrete complete all as specified and directed.
Providing formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floor and roofs exceeding 10 cm but not exceeding 20 cm wide for rough finished surfaces of concrete, flat complete all as specified and directed.
Providing formwork to chullah hoods, chajjas, troughs and similar items including edges for flat, rough finish surface of concrete complete all as specified and directed.
Providing formwork to the soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200 mm thick (horizontal or sloping ) and making flat, rough finished surfaces of concrete complete all as specified and directed
M&L for 100mm thick PCC (1:4:8) type D2 (using 40mm graded crushed stone aggregate), as in sub base for floor complete all as specified and directed.
M&L for 75mm thick PCC (1:4:8) type D2 (using 40mm graded crushed stone aggregate), as in sub base for floor complete all as specified and directed.
M&L for 50mm thick PCC (1:2:4) type B2 (using 40mm graded crushed stone aggregate), as in floor finishe rough complete all as specified and directed.
M&L for 75mm thick PCC (1:2:4) type B2 (using 40mm graded crushed stone aggregate), as in floor finishe rough complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C1 (using 20mm graded crushed stone aggregate) as in plinth protection including finishing the cement concrete surfaces fair & even complete all as specified and directed.
M&L for 75mm thick PCC (1:4:8) type D2 (using 40mm graded crushed stone aggregate), as in sub base for floor complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate), as in sub base for floor complete all as specified and directed.
M&L for mild steel structural steel work including tubular members conforming to Fe-410-S as in roof trusses (framed), struts, trussed purlins of beam, tee angle, channel, tubes section including distance pieces cleats etc and cutting to dead ends, notching, drilling, fittings, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fittings angle cleats, fish plate, gussets plates etc also for wedging turning up and fixing complete all as specified and directed.
S&F of pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F of pre-painted galvalume aluminium zinc coating GI based plain steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in ridge / wall/cladding, fixed with self tapping screws complete all as specified and directed.
M&L for brick work with sub class 'B' bricks locally available best quality straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:6) on brick work or concrete surfaces of wall, finished even and smooth without using extra cement complete all as specified and directed.
M&L for applying two coats of cement based paint over a coat of alkali resistance primer on newly plastered surface of walls including preparation of surface complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide primer after preparation of new steel surfaces of any description over 10cm width or girth complete all as specified and directed.
M&L for TMT bars 10 mm dia and over cut to length bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
S&F of TMT bars 6mm to 8mm dia and over cut to length bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for forming 12 mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, grade B for 100mm thick concrete slab complete all as specified and directed.
M&L for plain, black, mild steel sheeting, 0.63mm in ridge, hips, valley gutters, drip and straight flashing complete all as specified and directed.
S&F for bands, straps, supports or stays for rainwater, ventilating pipes including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fast, wind ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-e-165 complete all as specified and directed.
M&L for non skid (joint free) ceramic coloured tiles of 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed with white cement mixed with pigment to match with shed of tiles over and including 15mm thick screed bed or beading layer of cement mortar (1:4) for laying floor finishes complete all as specified and directed.
M&L for glazed ceramic coloured wall tiles (vertical) 450mm X 300mm X 7mm thick or equivalent set and jointed neat cement slurry and pointed with white cement mixed with pigment to match with shed of tiles as in skirting/dado/vertical wall over and including 10 mm thick cement plaster in cement mortar (1:3) complete all as specified and directed.
M&L for 20mm thick granite (any type) work (table rubbed and polished) machine cut in steps, jambs, pillars, window cill, cooking platform etc bedded and jointed with grey cement slurry and pointed with white cement (1:2) using marble dust with admixture of pigment to match the granite stone including and polishing over and including 15mm thick cement mortar (1:4) as screed bed complete all as specified and directed.
M&L for granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
M&L for rendering 5mm thick in cement mortar (1:3) on ceiling, chajja etc surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:4) on other than fair faces of brick work or concrete surfaces of wall, finished even and smooth without using extra cement complete all as specified and directed.
M&L for applying three coats of white wash on wall surface including preparation of new plastered surface complete all as specified and directed.
M&L for applying three coats of white wash on surface of ceiling, chajja including preparation of new plastered surface complete all as specified and directed.
S&F of steel windows with side hung shutters (glazed ) including box type hinges with steel handle, steel peg stay, complete with glazing bars , dovetailed or welded to receive wire mesh/glass complete all as specified and directed.
S&F of mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or forged into spikes; framed guard bars; barred iron doors; ladders, railings, framed brackets, walk ways, frame work of water tank and similar work conforming to Fe-290-0 Gde-E-165 complete all as specified and directed.
S&F of pressed steel frames (factory made) for door of size 125mm X 60mm of 1.25mm thick with one or more rebates including necessary fittings lugs, hinges, lock strike plate, etc including filling of concrete (1:3:6) type C-0 (using 12.50 mm graded crushed stone aggregate) including applying of two coats of black bituminous paint (shop coat) to back of chowkats complete all as specified and directed.
M&L for MS flat iron bent to shape, holes drilled etc as in holdfast, including a coat of red oxide paint complete all as specified and directed.
S&F of 35mm thick (factory made) plain, second class hard wood, framed, panelled shutters (three panels) with lock rails and panel of 12 mm veneered particle board with commercial veneering on both faces (BWR type), the size of rail and stile as per IS-1003 (Part-I) (larger size to be provided) klin seasoned and chemically pressure treated fitted to chowkats complete all as specified and directed.
S&F for 300 mm aluminum alloy, anodised, sliding door bolt with hasp and staple (bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloy and fixed complete all as specified and directed.
S&F of 150 mm long aluminium anodised extruded alloy handle fabricated type complete all as specified and directed.
S&F of 150 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer after preparation of new wooden surfaces of any description over 10 cm girth or width complete all as specified and directed.
S&F of 3.0mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares not exceeding 0.50 sqm each pane complete all as specified and directed.
M&L for applying evenly a coat of oil based bitumen primer confirming to IS-3384 on roof, canopy, chajja, parapet (vertical surface etc) @ 0.40 Litre / Per Sqm by the same membrane manufacturer of density 250C, 0.87 to 0.89 litre and viscosity 70-160 cps after proper cleaning the roof surfaces (horizontal/vertical) and providing APP based polymeric membrane minimum weighing 3.6 Kg/Sqm and minimum 3mm thick reinforced with polyester non wove fabric (weight not less than 150 gms / sqm) laid on primed surface with side over lap of 100 mm and end overlap of 150 mm, using bitumen torch or by LP gas torching and sealing all joints etc and ensuring complete thermo fusing and applying one coat of aluminum paint @100ml/Sqm over it all as per manufacturer's instructions complete all as specified and directed.
M&L for 15mm thick rendering in cement mortar (1:4) on RCC roof surfaces as screed bed for laying of APP membrane mixed with WPC @200ml/50 Kg of cement complete all as specified and directed. (Note : WPC shall be measured and paid separately)
Supply only integral water proofing compound liquid, ISI marked complete all as specified and directed.
M&L for pre-polished coloured chequered cement concrete tiles 30cm x 30cm x 25mm thick (glossy type), set, jointed and pointed in neat cement slurry in floors with grey cement and pigments over and including 20 mm thick cement screed bed in cement mortar (1:4) complete all as specified and directed.
S&F of 600mm dia reinforced concrete pipes, class NP3, laid and jointed complete all as specified and directed.
M&L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing of Fe-410W (Gde E-250) quality 'B' complete all as specified and directed.
M&L for MS plain sheets, plates square cut or notch forming holes, without any attachment etc Fe-290 (Gde E-165) etc complete all as specified and directed.
S&F of 125 mm long cold rolled mild steel butt hinges, heavy weight complete all as specified and directed.
PART-II M&L for GI pipe 40mm dia (light grade) complete with all fittings in trenches, road/culvert crossing, on wall, floors, on roof, on pole for cable protection complete all as specified and directed.
M&L for sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep including required watering and consolidation after laying and stretching the cable complete all as specified and directed. (Note: Only punned down volume of sand to be measured)
M&L for brick covering with width equal to length of brick as protection to cable with well burnt sub class ‘B’ bricks of size 250mm x 125mm x 75mm laid dry flat complete all as specified and directed .
S&F of SMC kiosks box suitable for three phase 415 volts AC supply with 04 Nos Aluminium bus bar rating 63 amps with one No MCB 16 Amps, SP having size 350x270x200 mm complete including making fixing arrangement with 12 mtr long swaged pole wiht flat iron clamp complete all as specified and directed (Make- Sintex/Star electric Eng Co./Universal switch gear control or equivalent of make as per Appx 'A' as mentioned in PS here-in-after)
S&F for steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified conforming to IS- 2317/1980 type 410 SP-55 (12 metres long) complete with cast iron base plate including staying the poles in a truly vertical position till the foundations are properly set, including painting to pole (inside & outside) with two coats of aluminium paint on exposed surfaces of poles and two coat of black bituminous paint on embedded portion complete all as specified and directed. (Note: Excavation, foundation concrete and coping will be measured and paid separately)
M&L for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 16 sqmm, 4 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing complete all as specified and directed. (NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required)
S&F of LED flood light 210 Watts 230 Volts, AC, Out door type with thermal management in multiple optics and equiped with IP-66 protection, with impact and corrosion resistant complete with driver and lamp complete including taking down old unserviceable light fitting from swaged/High mast light pole of maximum 12 metre height from the normal ground level complete all as specified and directed.
S&F for 1100 Volts grade heavy duty cable PVC insulated copper conductor PVC round sheathed (flexible) industrial cable in hight mast light pole connection from pole junction box at bottom to light fixed on 12 mtr long swaged pole by making two holes with welding machine for inserting cable of size 6 Sqmm 2 core multistranded including making all necessary connection complete all as specified and directed.
M&L for boring holes horizontally under road without damaging the surface of road (minimum 1.0m bellow the road surfaces) with the help of GI tubing of any dia not exceeding 80mm dia for passing of UG cable complete all as specified and directed.
M&L for MS cross arm, angle, clamps, nuts, bolts and washers and supply and fixing new MS Cross arms, bracings, supports, clamp and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any type, shape or as indicated and directed inclusive of one coat of red oxide and one coat of aluminium paint complete all as specified and directed .
M&L for point wiring complete with 1.5 sqmm PVC insulated, FR-LSH type, ISI marked, conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade (MMS) and including cutting, chasing work at any height and all accessories concealed in walls / roofs / floors / ceiling etc. flush mounting MS box with top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick and 50mm depth suitable for fixing of top cover , blanking plate as per numbers of switches, sockets, fan regulators, blank plates etc as approved coloures accessories of suitable and including 1.5 Sqmm PVC insulated multistranded FR-LSH type unsheathed single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surfaces by applying white/colour wash/distemper as applicable after applying of putty for smooth finish surface complete all as specified and directed for the following:- (Note:- (i) All necessary accessories such as sunken box, top cover , blank plate, MS box, screws, washers etc are to be used of same make/brand only in relevant items. (ii) Cutting & chasing of wall for point wiring at any height shall be done and cost of the same deemed to be including with quoted rate.)
One light point controlled by one switch .
One 3 pin 5 amps socket point controlled by one 6 amps switch on independent board .
One 3 pin 5 amps socket point controlled by one 6 amps switch on same board .
Ditto-all as per Item No.81.00 here-in-before but point wiring with 2.5sqmm PVC insulated multistranded flexible unsheathed copper conductor FR-LSH and earth conductor of size 2.50 sqmm PVC insulated multistranded flexible copper conductor FR-LSH of 3 pin, 15/16 Amps socket outlet on independent board complete all as specified and directed .
S&F of decorative box type 20 -22watt LED fittings with and including LED T-8 tube light 20 watt of fire retardant engineering grade complete with all accessories internally pre-wired, connecting up with and including three core sheathed flexible copper conductor cable of required size and including mounted on PVC/Wooden round/square blocks-02 Nos complete all as specified and directed. (Make - Havells Cat No REGALBATTENT8UPTO1 x 22WDSBSWH/Crompton Greaves cat No : DMLN1LT8-16 for fittings and make - Crompton Greaves Cat No LTT8-20 /Havells Cat No PHOTONULTRAE2.01213T8SSTL20WLED865SPC/Rashmi Cat No. RLTU20TLT8 as approved for LED lamp or equivalent model/Cat No of make as per Appx 'A' as mentioned in PS here-in-after)
S&F of angle lamp holder, insulated body with back plate for batten fittings complete all as specified and directed.
S&F of stepped type (0-4/5 step) electronic fan regulator 240 Volts, 100 Watts to 120 watts single pole, ISI marked including connecting, testing complete all as specified and directed.
S&F of socket out let, flush type, 2 in 1, 3/5 pin, 5/6 Amps, 240 volts, ISI marked, AC complete all as specified and directed.
S&F of switch piano flush button single pole, one way, 5/6 amp, 240 volts, AC, ISI marked complete all as specified and directed.
S&F of socket out let, flush type, 2 in 1, 3/5 pin, 5/6 and15/16 Amps, 240 volts, AC, ISI marked complete all as specified and directed.
S&F of switch piano flush button single pole one way 15/16 amp 240 volts, AC, ISI marked complete all as specified and directed.
S&F of ceiling rose , surface bakelite 65X50mm, three terminal, PVC/polycarbonate body complete all as specified and directed.
S&F of sheet metal enclosures for SPN DB's with double glazed door for incorporating MCBs,IP-43 , 4 way with 200 amps rated busbar, 240 volts, as per IS-8623 complete all as specified and directed.
S&F of MCBs SPN 32 amps, 240 volts, 50 Hz, 'C' curve including necessary incoming and out going electric connection with suitable size of copper lugs complete all as specified and directed.
S&F of MCB SP, 6 to 32 Amps, 240 volts, 50 Hz, 'C' curve including necessary incoming and out going electric connection with suitable size of copper lugs complete all as specified and directed.
M&L for earthing with glavanised steel eart plate electrode of size 60cmX60cmX6mm thick buried directly in ground (earth pit not less than 2.25 m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel using GI or steel wire 4mm dia as earthing lead as shown in electrical plate No.3 of SSR Part-I connected to earthing test point all specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC (1:3:6) type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe , 15mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) type A-1 duly reinforced with 8mm dia TMT bar @150c/c both ways, one lifting handle made out of 10mm dia TMT bar 250 mm long embedded in cover slab and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer of 15 cm thick complete all as specified and directed. (Notre: Galvanised iron wire of 4mm dia upto 7.5m long including testing is deemed to be included with quoted rate).
M&L for GI pipe 50mm dia (light grade) complete with all fittings in trenches, road/culvert crossing, on wall, floors, on roof, on pole for cable protection complete all as specified and directed.
Supply, fabricated and fixing of street light bracket made out of GI pipe 40mm dia medium grade bent to shape of 1.2 mtr long as directed including clamps made out of 40 mm x 6 mm flat iron for fixing bracket suitable for steel tubular poles including nuts and bolts, washers and other connected items of required size including painting with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
S&F of 36 watt LED street light fittings IP-65/66 pressure die cast housing LED lamp aluminium compact high power LED street light with heat resistant toughened glass with LED lamp and necessary connection with suitable size copper cable complete all as specified and directed . (Make : Crompton Greaves Cat No LSTS-36-CDL-M/ Bajaj Cat No BRTFG 36W LED/Philips Cat No. BRP052 LED 036 CW HP SLAF G SI PSU GR or equivalent model/Cat No of make as per Appx 'A' as mentioned in PS here-in-after)
Supply, installation, testing and commissioning of On line UPS having capacity 5/5.5 KVA, input voltage range 192 Volts and output voltage 230 Volts, AC, single phase input and single phase output, heavy duty type with over voltage, over current and short circuit protection, digital display type, with 95% efficiency alongwith external batter bank with 12 Nos maintenance free dry type batteries of rating 26 AH, 12 Volts fixed with suitable size battery cabinet/stand including suitable size copper wiring from battery bank to UPS and UPS to output point/equipment complete all as specified and directed. (Note: (i) Quoted rate is deemed to be included for 12 Nos 26 AH dry type maintenance free batteries, battery stand/cabinet and 5/5/5 KVA online UPS and necessary electrical connection as required at site (ii) Warranty of online UPS -01 year from date of installations (iii) Warranty on batteries- 02 years from date of installation) (Make of batteries: Exide/Standard Furrukawa/Amaron)
M S SAWASTI ENTERPRISE
INDUSTRIAL CONSTRUCTION
S S ENTERPRISE
CHATTERJEE ENTERPRISE
M/S D K Singha
M/S. BENGAL TRADERS
M/S KARTICK CHANDRA CHAKRABORTY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .