Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAccepted-AOC 37 CENTRAL ROAD AGARTALA | AGARTALA | WEST TRIPURA | TRIPURA | ₹1.6 Cr | L1 | Accepted-AOC It is found the bidder is 1st lowest |
| 2 | L2₹1.6 Cr+₹5.5 L (3.50%)Rejected-AOC DHALESWAR JAIL ASHRAM ROAD AGARTALA TRIPURA W | DHALAI | TRIPURA | 799204 | ₹1.6 Cr+₹5.5 L (3.50%) | L2 | Rejected-AOC This bidder is 2nd lowest |
| 3 | L3₹1.7 Cr+₹17.7 L (11.3%)Rejected-AOC JATANBARI KARBOK GOMATI TRIPURA | ₹1.7 Cr+₹17.7 L (11.3%) | L3 | Rejected-AOC This bidder is 3rd lowest |
| 4 | L4₹1.8 Cr+₹24.4 L (15.6%)Rejected-AOC COLLEGE CHOWMUHANI JIRANIA WEST TRIPURA | ₹1.8 Cr+₹24.4 L (15.6%) | L4 | Rejected-AOC This bidder is 4th lowest |
Tender Value
₹1.6 Cr
EMD Value
₹3.2 L
Closing Date
23 Feb 2024, 3:00 pmClosed
Deputy General Manager, Electrical Division Sabroo
Electrical Division- Sabroom Tripura State Electricity Corporation Limited
Providing of 11 KV dedicated feeder at Integrated Check Post (ICP) Sabroom under the control of Sabroom Electrical Division
2024_POWER_46784_1
DNIT/DGM/ED-SBM/23-24/08 dated 08.02.2024
Open Tender
Civil Works
Works
180 days
Electrical Division- Sabroom
Please refer Tender documents.
3 documents required · 3 mandatory
₹10,000
Yes
₹3.2 L
Yes
21 Mar 2024
8 Feb 2024
24 Feb 2024
8 Feb 2024
23 Feb 2024
8 Feb 2024
8 Feb 2024 - 20 Feb 2024
Amount
Supplying of 11 KV U.G.,185 sq. mm. 3C, TR-XLPE insulated conductor and insulation screened Aluminium conductor Power cable as per IS : 7098/II/1985 ans latest amendments incl. taxes , duties,freight & insurance etc as per technical spec of the Bid document.
Outdoor type Heat Shrink Jointing kit suitable for 185 sq. mm. 3C, XLPE UG cable
Indoor type heat shrink cable jointing kit size of 185 sqmm 3C, XLPE UG cable.
Supply and erection of 4 way ( 1 incoming and outgoing feeder) HT Kiosk/11KV Outdoor type feeder pillar made of MS Sheet of 10 SWG MS sheet complete with aluminium basbar, HT insulator etc as required provided with locking system and painting to be fitted on structor of MS angle(50X50X6mm) and M.S. flat (40X6mm) including supply of MS angle and flat as required and connecting of ratio 1:2:4 with excavation of earth, centering shuttering & disposal excess soil.(as per RAPDRP Rate)
11.0 mtr long steel tubular pole
Galvanised Stay set complete
Stay Insulator (HT)
Stander Stay Wire
Galvanised 75x40x40x6 mm M.S. Channel
GI Bkt. Clamp (50x6 mm)
GI Stay Clamp (50x6 mm)
GI Nuts & bolts of assorted size
Excavation, erection, testing & commissioning of 40mm dia, 2.5 m long GI pipe earth electrode with test link, RCC pit, RCC cover plates on GI frame, charcoal, salt and other accessories complete.
8 SWG G.I. wire (4 mm) for earth connectivity
¾ th inch dia. Polythin Pipe
HDPE Pipe PE 100 grade 110 mm outer Dia
100 mm. dia. TATA/JINDAL/ BANSAL make best quality G.I. pipe as per IS:1239 (as per price list)
Supply of 11 KV,800 Amps continuos rated current, 350 MVA rupturing capacity Indoor Vaccum Circuit Breaker ( for outgoing feeder), complete with 1 set of CT of ratio 200/1.5 Control & Relay Pannel Simplex type with 110 Volt DC actuated electrical closing/ tripping mechanism and internal wiring , 2-Over current & 1-earth fault combined micom digital relay, 1 no electromechanical AREVA Master Trip Realy auxiliary relays as required, 1 no. L& T / SECURE make "Tri-Vector" Meter (SCADA compatible), 3 Ammeter, 1 Voltmeter, 1 C.T opareted static KW meter, with panel bus mounted C.T and integal earthing facility including inemal arc tested panel Conforming to relevant ISS/IEC as reqd. including standard indication facilities as per reqirment detyailed herein after.
Supply of 11 kv Ring Main Unit : 12 KV motorrised ringmain unit, self power typewith CPT or by other means, solid or SF6 installation, outdoor enclouser, FPI, battery and charging system, software, all accessories and tools as provided in technical specification 3 way RMU Type SBBBSS.
Laying & commisioning of 3XC, 185 Sqmm, 6.35/11KV, XLPE insulated armoured HT power cable direct into earth including excavation of earth up-to a depth of 1100 mm (Width of the trench 40 cm) including 1st class brick protection of two layer flat brick soling, 300 mm. sand (river sand) cushoning and refilling and ramming the excavated soil and also make devider by layig of bricks to protect both the cables as per direction of the EIC.
Fitting, fixing of outdoor type Heat Shrink Jointing kit suitable for 185sq. mm. 3XC, XLPE UG cable
Fitting, fixing of Indoor type heat shrink cable jointing kit size of 185 sqmm 3XC, XLPE UG cable.
11.0 mtr long galvenised steel tubular pole
Stay set complete
Stay Insulator (HT)
Stander Stay Wire
Galvenised 75x40x40x6 mm M.S. Channel
8 SWG G.I. wire (4 mm) for earth connectivity
100 mm. dia. TATA/JINDAL/ BANSAL make best quality G.I. pipe as per IS:1239 (as per price list)
Erection of 11 KV,800 Amps continuos rated current, 350 MVA rupturing capacity Indoor Vaccum Circuit Breaker ( for outgoing feeder), complete with 1 set of CT of ratio 200/1.5 Control & Relay Pannel Simplex type with 110 Volt DC actuated electrical closing/ tripping mechanism and internal wiring , 2-Over current & 1-earth fault combined micom digital relay, 1 no electromechanical AREVA Master Trip Realy auxiliary relays as required, 1 no. L& T / SECURE make "Tri-Vector" Meter (SCADA compatible), 3 Ammeter, 1 Voltmeter, 1 C.T opareted static KW meter, with panel bus mounted C.T and integal earthing facility including inemal arc tested panel Conforming to relevant ISS/IEC as reqd. including standard indication facilities as per reqirment detyailed herein after.
Supply & Errection of Cable identification marker: Providing of pre-cast cement concrete cable identification route marker (1 cement: 2 sand : 4 graded stone aggregrate 6 mm nominal size) reinforced with 1.6 mm dia mild steel wire including centering and shuttering, roughening cleaning, fixing and finishing in cement morter 1:3 (1 cement: 3 fine sand) etc. complete, excluding the plastering of jambs, sills and soffits as per design, drawing and specification of TSECL. The marker shall be embossed " DANGERS: TSECL, 11KV Power cable" with black colour letter (Both side). The vissible part shall be painted with yellow colour Japan Paint.
Erection, testing & commissioning of 11 kv Ring Main Unit : 12 KV motorrised ringmain unit, self power typewith CPT or by other means, solid or SF6 installation, outdoor enclouser, FPI, battery and charging system, software, all accessories and tools as provided in technical specification 3 way RMU Type SBBBSS with appropriate civil work.
ADHIR DEBNATH
RATAN PAUL
Asish Debnath
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .