Industry Unit; Creating the melter from the Satvik Sulfur Furnace with a new 8 10 mm plate and giving it a satisfactory trial by installing the steam coil; Buyer
Repair
Maintenance
and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Removing the worn out coils in the melters of the Satvik Sulfur Furnace replacing them with new ones and conducting hydraulic testing and giving a sat..
and Installation of Plant Systems/Equipments (Version 2) - Industry Unit; Removing the worn out plates of the vacuum filter condensers replacing them with new ones and giving a satisfactory trial; Buyer
and Installation of Plant Systems/Equipments (Version 2) - Industry Unit; Removing the damaged weak steam coils in the film tine sulfur melters replacing them with new ones and conducting hydraulic testing and giving a sati..
and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Renovate and install a new SO2 chamber inside the coolers of the Satvik Sulfur Furnace and conduct a trial; Buyer
and Installation of Plant Systems/Equipments (Version 2) - Industry Unit; Remove the old corroded SO2 gas line at the sulfur furnace station and install the new seamless MS line with flanges tightening the joints and bolts;..
and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Remove the grooved plate of the mud mixture on the vacuum filter and repair it with the new plate provided; Buyer
and Installation of Plant Systems/Equipments (Version 2) - Industry Unit; Remove the grooved plate of the filtrate tank located below the vacuum filter install the plate provided and perform a trial; Buyer
and Installation of Plant Systems/Equipments (Version 2) - Industry Unit; Repairing the weak parts of juice and mud with dry box of clarifier and making all the connections; Buyer
and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Patch the weak shell of the burning chamber of the film type sulfur furnace with the plate provided for a length of approximately 5 feet from the bottom a..
and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Patch the weak and rotten platforms of both vacuum filters with a new burner from the provided plate; Buyer
and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Removing the SO2 chamber inside the last cooler of the film type sulfur furnace and installing a new one using the provided 10 mm MS plate and making all ..
and Installation of Plant Systems/Equipments (Version 2) - Industry Unit; Repairing the damaged clear juice bottles near the clear juice pumps and making all the connections and giving satisfactory trial; Buyer
and Installation of Plant Systems/Equipments (Version 2) - Industry Unit; Cut out and remove all rotten mud scrapers inside the door clarifier and install the provided plates and belts according to size and give a satisfacto..
and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Coat and remove the weak mud boot plates in each compartment of the clarifier and install the provided new plates; Buyer
and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Repairing the weak parts of the agitator fitted on the vacuum filter and giving satisfactory trial; Buyer
and Installation of Plant/Systems/Equipments
and Installation of Plant Systems/Equipments (Version 2) - Industry Unit; Cutting out all the worn out weak cooling pipes and flanges of the coolers of the Satvik Sulphur Furnace and installing new flanges and cooling pipes usi..
and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Cutting out the worn out weak flanges of the coolers of the Sulphur Furnace and installing new flanges using the provided plate and giving it a satisfact..
and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Cut and remove the weak corroded cross in the gas pipeline at the Sulphur Furnace Station and install the cross by making a new flange from the provided ..
and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Cut and remove the weak corroded header of the Sulphur Furnace and install it from the provided plate and pipeline and connect the nipples and give a sat..
and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Repairing the bagasse line leading to the mill installed above the vacuum filter station in the boiling house and conducting a satisfactory trial; Buy..
and Installation of Plant Systems/Equipments (Version 2) - Industry Unit; Remove the brass SS tubes from the quad and store them; Buyer
and Installation of Plant Systems/Equipments (Version 2) - Industry Unit; Install the new brass SS tubes provided by the mill committee in the calandria expand them and conduct hydraulic testing of the calandria at a pressu..
and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; a Dismantling old columns beam channels etc b Manufacturing and installing new columns beam channels etc; Buyer
and Installation of Plant Systems/Equipments (Version 2) - Industry Unit; Removing the old corroded platform and replacing it with a new one; Buyer
and Installation of Plant Systems/Equipments (Version 2) - Industry Unit; Installing 16 inch 18 inch manholes with blinds; Buyer
and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Constructing a bed for the pump fitting the pump and motor and conducting a trial run of up to 20 HP; Buyer
and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Dismantling fabricating and erecting weak corroded pipe lines up to 12 and providing satisfactory leak proof trials; Buyer
and Installation of Plant Systems/Equipments (Version 2) - Industry Unit; Dismantling fabricating and erecting weak corroded tees up to 12 and providing satisfactory leak proof trials; Buyer
and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Dismantling fabricating and erecting weak corroded nipples up to 12 and providing satisfactory leak proof trials; Buyer
and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Dismantling fabricating and erecting a weak throated cross member up to 12 and providing satisfactory leak proof trials; Buyer
and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Dismantling fabricating and erecting a weak throated band up to 12 and providing satisfactory leak proof
and Installation of Plant Systems/Equipments (Version 2) - Industry Unit; Dismantling fabricating and erecting a weak throated flange up to 12 and providing satisfactory leak proof trials; Buyer
and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Dismantling fabricating and erecting a weak sloping reducer up to 12 and providing a satisfactory leak proof trial; Buyer
9801878
GEM/2026/B/7957428
Two Packet Bid
Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - Industry Unit; Rem
Saharanpur, Uttar Pradesh
Item wise evaluation
SERVICE
5 documents required · 5 mandatory
5 yrs
₹3.6 L
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Industry Unit; Creating the melter from the Satvik Sulfur Furnace with a new 8 10 mm plate and giving it a satisfactory trial by installing the steam coil; Buyer | - | - | - |
| Repair | - | - | - |
| Maintenance | - | - | - |
| and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Removing the worn out coils in the melters of the Satvik Sulfur Furnace replacing them with new ones and conducting hydraulic testing and giving a sat.. | - | - | - |
| and Installation of Plant Systems/Equipments (Version 2) - Industry Unit; Removing the worn out plates of the vacuum filter condensers replacing them with new ones and giving a satisfactory trial; Buyer | - | - | - |
| and Installation of Plant Systems/Equipments (Version 2) - Industry Unit; Removing the damaged weak steam coils in the film tine sulfur melters replacing them with new ones and conducting hydraulic testing and giving a sati.. | - | - | - |
| and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Renovate and install a new SO2 chamber inside the coolers of the Satvik Sulfur Furnace and conduct a trial; Buyer | - | - | - |
| and Installation of Plant Systems/Equipments (Version 2) - Industry Unit; Remove the old corroded SO2 gas line at the sulfur furnace station and install the new seamless MS line with flanges tightening the joints and bolts;.. | - | - | - |
| and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Remove the grooved plate of the mud mixture on the vacuum filter and repair it with the new plate provided; Buyer | - | - | - |
| and Installation of Plant Systems/Equipments (Version 2) - Industry Unit; Remove the grooved plate of the filtrate tank located below the vacuum filter install the plate provided and perform a trial; Buyer | - | - | - |
| and Installation of Plant Systems/Equipments (Version 2) - Industry Unit; Repairing the weak parts of juice and mud with dry box of clarifier and making all the connections; Buyer | - | - | - |
| and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Patch the weak shell of the burning chamber of the film type sulfur furnace with the plate provided for a length of approximately 5 feet from the bottom a.. | - | - | - |
| and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Patch the weak and rotten platforms of both vacuum filters with a new burner from the provided plate; Buyer | - | - | - |
| and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Removing the SO2 chamber inside the last cooler of the film type sulfur furnace and installing a new one using the provided 10 mm MS plate and making all .. | - | - | - |
| and Installation of Plant Systems/Equipments (Version 2) - Industry Unit; Repairing the damaged clear juice bottles near the clear juice pumps and making all the connections and giving satisfactory trial; Buyer | - | - | - |
| and Installation of Plant Systems/Equipments (Version 2) - Industry Unit; Cut out and remove all rotten mud scrapers inside the door clarifier and install the provided plates and belts according to size and give a satisfacto.. | - | - | - |
| and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Coat and remove the weak mud boot plates in each compartment of the clarifier and install the provided new plates; Buyer | - | - | - |
| and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Repairing the weak parts of the agitator fitted on the vacuum filter and giving satisfactory trial; Buyer | - | - | - |
| and Installation of Plant/Systems/Equipments | - | - | - |
| and Installation of Plant Systems/Equipments (Version 2) - Industry Unit; Cutting out all the worn out weak cooling pipes and flanges of the coolers of the Satvik Sulphur Furnace and installing new flanges and cooling pipes usi.. | - | - | - |
| and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Cutting out the worn out weak flanges of the coolers of the Sulphur Furnace and installing new flanges using the provided plate and giving it a satisfact.. | - | - | - |
| and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Cut and remove the weak corroded cross in the gas pipeline at the Sulphur Furnace Station and install the cross by making a new flange from the provided .. | - | - | - |
| and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Cut and remove the weak corroded header of the Sulphur Furnace and install it from the provided plate and pipeline and connect the nipples and give a sat.. | - | - | - |
| and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Repairing the bagasse line leading to the mill installed above the vacuum filter station in the boiling house and conducting a satisfactory trial; Buy.. | - | - | - |
| and Installation of Plant Systems/Equipments (Version 2) - Industry Unit; Remove the brass SS tubes from the quad and store them; Buyer | - | - | - |
| and Installation of Plant Systems/Equipments (Version 2) - Industry Unit; Install the new brass SS tubes provided by the mill committee in the calandria expand them and conduct hydraulic testing of the calandria at a pressu.. | - | - | - |
| and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; a Dismantling old columns beam channels etc b Manufacturing and installing new columns beam channels etc; Buyer | - | - | - |
| and Installation of Plant Systems/Equipments (Version 2) - Industry Unit; Removing the old corroded platform and replacing it with a new one; Buyer | - | - | - |
| and Installation of Plant Systems/Equipments (Version 2) - Industry Unit; Installing 16 inch 18 inch manholes with blinds; Buyer | - | - | - |
| and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Constructing a bed for the pump fitting the pump and motor and conducting a trial run of up to 20 HP; Buyer | - | - | - |
| and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Dismantling fabricating and erecting weak corroded pipe lines up to 12 and providing satisfactory leak proof trials; Buyer | - | - | - |
| and Installation of Plant Systems/Equipments (Version 2) - Industry Unit; Dismantling fabricating and erecting weak corroded tees up to 12 and providing satisfactory leak proof trials; Buyer | - | - | - |
| and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Dismantling fabricating and erecting weak corroded nipples up to 12 and providing satisfactory leak proof trials; Buyer | - | - | - |
| and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Dismantling fabricating and erecting a weak throated cross member up to 12 and providing satisfactory leak proof trials; Buyer | - | - | - |
| and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Dismantling fabricating and erecting a weak throated band up to 12 and providing satisfactory leak proof | - | - | - |
| and Installation of Plant Systems/Equipments (Version 2) - Industry Unit; Dismantling fabricating and erecting a weak throated flange up to 12 and providing satisfactory leak proof trials; Buyer | - | - | - |
| and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Dismantling fabricating and erecting a weak sloping reducer up to 12 and providing a satisfactory leak proof trial; Buyer | - | - | - |
GENERAL MANAGER, SARSAWA SAHARANPUR, (The Kisan Cooparetive Sugar Factory Ltd. Sarsawa)
Exempted
Yes
24 Aug 2026
24 Aug 2026
4 Sept 2026
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_9801878.pdf
GEM_BID • 0.55 MB
1787585368.xlsx
GEM_OTHER • 0.01 MB
1787585380.pdf
GEM_OTHER • 3.32 MB
1787585382.pdf
GEM_OTHER • 3.32 MB
1787585389.pdf
GEM_OTHER • 3.32 MB
1787585391.pdf
GEM_OTHER • 3.32 MB
SANCTION_1c08241a-1c3a-448c-8ffa1787585680525_karanrathi.ssw.pdf
GEM_OTHER • 3.32 MB
gtc.pdf
GEM_OTHER • 0.71 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].