| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹46.6 L+₹3.6 L (8.48%)Rejected-Finance R O 218 05 OPP J D A COMPLEX TRIKUTA NAGAR JAMMU J K PIN 180020 | JAMMU | JAMMU AND KASHMIR | 180020 | L2 | Rejected-Finance L2 | |
| 3 | L3₹47.6 L+₹4.6 L (10.7%)Rejected-Finance HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L3 | Rejected-Finance L3 | |
| 4 | L4₹49.1 L+₹6.1 L (14.2%)Rejected-Finance H O WANI HOUSE II SHOWPORA SRINAGAR J K | L4 | Rejected-Finance L4 |
| Sl No | Description | Qty | Unit | M/S WEB COMPNAY L4 | M/S OSHO TRADERS L1 | SUMEET TRADING CORPORATION L3 | M/S ZTECH L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole etc in hard/dense soil | 54.11 | Cum | 412 ₹22,292.5 | 300 ₹16,232.4 Lowest | 408 ₹22,076.06 | 400 ₹21,643.2 |
| 2.00 | Excavation in trenches exceeding 1.5 mtr wide and not exceeding 1.5 mtrs in depth for laying of cables including getting out in hard soil complete all as specified and directed. ( for pole ) | 3.89 | Cum | 470 ₹1,827.36 Lowest | 550 ₹2,138.4 | 612 ₹2,379.46 | 600 ₹2,332.8 |
| 3.00 | Returning, filling in, including spreading, leveling watering, and well ramming in layers not exc 25 cm in hard/dense soil all as directed. | 10.82 | Cum | 88 ₹952.34 | 80 ₹865.76 Lowest | 86.7 ₹938.27 | 85 ₹919.87 |
| 4.00 | Removing excavated material n.exc 50m and depositing where directed at a level exc. 1.5 cm above the starting point all as directed. | 43.29 | Cum | 102 ₹4,415.17 | 90 ₹3,895.74 Lowest | 96.9 ₹4,194.41 | 95 ₹4,112.17 |
| 5.00 | Supply and fix in repair GI Pipe Light grade with all connected accessories of sizes 100 mm dia completed as directed for cable protection | 16 | RM | 890 ₹14,240 | 250 ₹4,000 Lowest | 260.1 ₹4,161.6 | 255 ₹4,080 |
| 6.00 | S&F in repairs cable end joint 120 to 185 Sqmm 3 core XLPE 11KV HT Cable heat shrinkable outdoor type complete all as specified and directed. | 4 | Each | 6,900 ₹27,600 Lowest | 7,500 ₹30,000 | 7,956 ₹31,824 | 7,800 ₹31,200 |
| 7.00 | S&F in repairs cable straight through joint 120 to 185 Sqmm 3 core XLPE 11KV HT Cable heat shrinkable complete including necessary excavation and earth work all as specified and directed. | 3 | Each | 7,800 ₹23,400 Lowest | 8,500 ₹25,500 | 9,078 ₹27,234 | 8,900 ₹26,700 |
| 8.00 | S&F in repairs cable end joint 50 to 95 Sqmm 3 core XLPE 11KV HT Cable heat shrinkable outdoor type complete all as specified and directed. | 4 | Each | 6,700 ₹26,800 | 6,500 ₹26,000 Lowest | 7,752 ₹31,008 | 7,600 ₹30,400 |
| 9.00 | M&L for services for cable fault location for 11 KV, 3 core XLPE Cable 95 sqmm to 185 sqmm with the help of HT cable fault detector machine complete all as directed. Note : Cost of equipement /machinaries incl electrician and labour cost including transportation deemed to be included in the qouted rate. | 4 | Each Job | 2,100 ₹8,400 | 500 ₹2,000 Lowest | 561 ₹2,244 | 550 ₹2,200 |
| 10.00 | M&L for filtration of transformer oil to remove moisture, sludge, carbon particles and to achieve dielectric strength/rupturing capacity of oil and topping up of oil to the required level of the transformer indicator level all as directed.
Note:
(a) Oil topping up shall be measured and paid separately.
(b) Filtration shall be done at site and on line. (c) BDV test shall be carried out before the filtration and after the filtration & results recorded in triplicate duly signed by the contractor, MES rep. and Engr-in-charge (d) Dielectric strength of the oil shall not be less than 50 KV after filtration & the rate quoted for the items shall be deemed to include the filtration till the desired dielectric strength is achieved. | 1,200 | Ltr | 190 ₹2,28,000 | 50 ₹60,000 Lowest | 56.1 ₹67,320 | 55 ₹66,000 |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
16 Aug 2025, 6:00 pmClosed
GE Khumbathang
KHUMBATHANG
GE/KHU-59/2025-26 REPAIR MAINTENANCE AND IMPROVEMENT OF ELECTRIC SUPPLY REPAIR TO TRANSFORMERS AND OTHER ALLIED WKS AT KHALTSI LAMAYURU HANUTHANG ACHINATHANG BIAMAH AND BATALIK AND REPAIR MAINTENANCE OF MCBs DBs SUB MAIN WIRING AND ELECTRIC FITTIN
2025_MES_721108_1
GE/KHU-59/2025-26
Open Tender
Support/Maintenance Service
Item Rate
180 days
GE Khumbathang
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE khumbathang
₹80,000
14 Oct 2025
18 Jul 2025
17 Aug 2025
18 Jul 2025
16 Aug 2025
31 Jul 2025
19 Jul 2025 - 30 Jul 2025
Amount
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole etc in hard/dense soil
Excavation in trenches exceeding 1.5 mtr wide and not exceeding 1.5 mtrs in depth for laying of cables including getting out in hard soil complete all as specified and directed. ( for pole )
Returning, filling in, including spreading, leveling watering, and well ramming in layers not exc 25 cm in hard/dense soil all as directed.
Removing excavated material n.exc 50m and depositing where directed at a level exc. 1.5 cm above the starting point all as directed.
Supply and fix in repair GI Pipe Light grade with all connected accessories of sizes 100 mm dia completed as directed for cable protection
S&F in repairs cable end joint 120 to 185 Sqmm 3 core XLPE 11KV HT Cable heat shrinkable outdoor type complete all as specified and directed.
S&F in repairs cable straight through joint 120 to 185 Sqmm 3 core XLPE 11KV HT Cable heat shrinkable complete including necessary excavation and earth work all as specified and directed.
S&F in repairs cable end joint 50 to 95 Sqmm 3 core XLPE 11KV HT Cable heat shrinkable outdoor type complete all as specified and directed.
M&L for services for cable fault location for 11 KV, 3 core XLPE Cable 95 sqmm to 185 sqmm with the help of HT cable fault detector machine complete all as directed. Note : Cost of equipement /machinaries incl electrician and labour cost including transportation deemed to be included in the qouted rate.
M&L for filtration of transformer oil to remove moisture, sludge, carbon particles and to achieve dielectric strength/rupturing capacity of oil and topping up of oil to the required level of the transformer indicator level all as directed. Note: (a) Oil topping up shall be measured and paid separately. (b) Filtration shall be done at site and on line. (c) BDV test shall be carried out before the filtration and after the filtration & results recorded in triplicate duly signed by the contractor, MES rep. and Engr-in-charge (d) Dielectric strength of the oil shall not be less than 50 KV after filtration & the rate quoted for the items shall be deemed to include the filtration till the desired dielectric strength is achieved.
Supply and fill new transformer oil topping up / change complete superior quality having di - electric strength not less than 60 KV and ISI marked of approved make.Note: Items rates deemed to include for (a) The transformer oil shall be ISI marked, and brought at site in sealed container only. (b) Collection of samples before and after topping up/changing including testing for dielectric strength.
Disconnecting the transformer any type situated at various locations 11/ 0.433 KV of any make and transporting to workshop for repairs/ rewinding. Dismantling the transformer and accessories, draining out insulating oil, taking out the core assembly, defective winding, cleaning the transformer complete internally and externally providing new insulation, sleeves for outlet connections, ovening the complete core assembly, reassembling, including dehydration and filtration of transformer oil to achieve desired dielectric strength, carrying out routine test, re-installation and commissioning. The repair work also includes the routine tests i.e. IR value, High voltage test, Ratio test, Short circuit test & BD value of oil of the transformer to be carried out at workshop for following capacities of transformer :-
400 KVA. Notes (i) Copper winding wire/strip will be measured and paid separately. (ii) Transformer oil for topping up will be measured and paid separately. (iii) Taking out transformer from its original position and Transportation to repair workshop and re-installation in same location is deemed to include in quoted rates.
M&L for taking out of burnt HT coil winding and replacement of the same with new copper wire coil of same gauge and turns including necessary insulation materials like impregnated paper or super enamelled of transformers of capacity 25/100/250/400 KVA all as directed by Engr - in - Charge
M&L for taking out of burnt LT coil winding and replacement of the same with copper strips of same gauge and turns including necessary insulation materials of transformers of capacity 25/100/250/400 KVA all as directed by Engr - in - Charge
Disconnecting the transformer any type from HT/ LT system and opening carefully for rectifying the leakage by replacing the unserviceable spare parts of capacity 25 to 400 KVA transformer and complete assembling after repairs including testing for any oil leakages, proper functioning and connecting the HT/ LT system all as specified and directed Note :- Defective parts replaced will be measured and paid separately
Supply only in repair of LT bushings with brass studs.
Supply only in repair of top cover gasket set.
Supply only in repair of radiator flanged gasket 6 mm thick.
Supply only in repair of oil level indicator gasket set.
Supply only in repair of HT bushing with brass studs 11 KV.
Supply and fix in replacement of breather assembly transparent plastic body with top and bottom portion pressed with metallic cover, filled with silica gel blue in colour and suitable for fixing on existing pipe of size 15/20/25 mm dia with suitable reducers/connectors etc as per site requirement /capacity of transformer.
S&F in repair lightning arrestor non linear resister type (Surge) suitable for 11000 volt grade conforming to IS-3070 Part-I with discharge capacity 65 kilo Amps including stranded coloured sleeved jumper connection with PG clamps mounted on steel mounting fabrication of MS clamps, bolts, nuts, washers etc all as specified and directed.
M & L for replacement of earthing continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/piope or fixed to poles or any other indicated situation for loop earting etc as required 32x6 mm galvanised iron strip .
M&L for Taking up tilted/leaned steel tubular pole 09/11 Mtr pole by breaking the coping , PCC foundation , securing the pole with rope for safety ,shifting the pole from public highway/valley side and stacking in safe location for refixing the same in original/ new suitable location all as specified and directed. Note: Rate for fouondation PCC and coping will be measured and paid seperately as relevent item of schedule.
Supply and erection truely vertical position steel tubular swaged pole complete with cast iron base plate finial taper plug, bolts, nuts and screws as specified type 410 SP-31 ( 09 mtr long), complete all as specified and directed by Engr-in-Charge. ( For intermediate poles and and for converting single pole to two pole structure )
M&L for refixing the Electric pole 09/11 Mtr long retrieved from item No 26 here in above , bringing the HT pole from stacked area, placing in trenches, alignment of pole for truly vertical position , securing the pole with rope for safety provding PCC incl proper ramming complete with PCC coping all as specified and directed at site . Note: The work wl be executed at mountain areas. PCC and earth work will be measured and paid seperately as per relevent item of this schedule.
M&L for dismadling of tilted two pole structure including removal of all channels , nut bolt and washers , removing insulators and taking down HT 11 mtr poles( 02 nos) from ground incl taking out from original location and stacking all materials in safe custudy for refixing complete all as specified and directed. Note: The work wl be executed at mountain areas.
M&L for dismadling of tilted 4 pole structure including removal of all channels , nut bolt and washers , removing insulators and taking down HT 11 mtr poles( 04 nos) from ground incl taking out from original location and stacking all materials in safe custudy for refixing complete all as specified and directed. Note: The work wl be executed at mountain areas.
M&L for refixing the dismanltled 02 pole structure 09/11 Mtr long retrieved from item No 29 here in above , bringing the HT pole, Channels , GODs and insulators from stacked area, placing in trenches, alignment of pole for truly vertical position , fixing of AI channels and insulators, fittment of GODs with insulator securing the pole with rope for safety provding PCC incl proper ramming complete with PCC coping all as specified and directed at site . Note: The work wl be executed at mountain areas. PCC and earth work will be measured and paid seperately as per relevent item of this schedule.
M&L for refixing the dismanltled 04 pole structure 09/11 Mtr long retrieved from item No 30 here in above , bringing the HT pole , GODs , channels and insulators from stacked area, placing in trenches, alignment of pole for truly vertical position , fixing of AI channels and insulators, fittment of GODs with insulator securing the pole with rope for safety provding PCC incl proper ramming complete with PCC coping all as specified and directed at site . Note: The work wl be executed at mountain areas. PCC and earth work will be measured and paid seperately as per relevent item of this schedule.
Labour only for rejointing brocken ACSR conductor between HT single poles , connecting to insulator restretching the coductor on pole incl jumper wire complete all as specified and directed. Note: The work wl be executed at mountain areas.
Labour only for rejointing brocken ACSR conductor between HT two pole/4 pole structure single poles , connecting to insulator restretching the coductor on pole incl jumper wire complete all as specified and directed. Note: Min span will be 500 Mtr between mountains and max span 1800 mtr . The work wl be executed at mountain areas.
M&L for Cross arms, bracings, supports, clamps and back plates abricated from structural steel sectionsincluding nuts, bolts, washers, welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete
Labour only for taking down XLPE cable any size/type complete all as specified and directed.Note : Excavation and eartyh work measured and paid seperately
XLPE insulated, screened, PVC bedded,galvanised steel strip or wire armoured,electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 95 sq. mm
S&F in repair stay assembly complete with accessories as shown in electrical plate No 1 and diameter of stay rod 16 mm complete including dismantling of old unsv stay. (loop type insulator,stay clamps,excavation and concrete measured separately). Note; The work wl be executed at diiferent places of HT line between Khlatsi and Lamyuru
M&L for replacing loop insulator Large size, with overall dimensions 90mmx140mm, clearance of hole 25.5mm for stay assy 11000 volt grade complete all as specified and directed.
Taking down defective unserviceable GOD from pole and supply and fix gang operated air break switches incl 12 insulators mounted on MS Channel with operating mechanism worked from ground level suitable 11000 volts, 200 Amps including GI pipe handle clamps bolts, nuts, jumper wire connecting with stranded conductors complete with locking arrangements.
S&F in repair Aluminium conductor, steel reinforced, of size 6/211 to 6/3010 mm (Squirrel to Ferret) straining properly on insulators with and including aluminium tape/winding wire, clamps & jumpers etc. complete all as specified. Note : 3% for sag shall be added in measurement .
S&F in repair pin type polymer insulator white,brown,grey insulator 150 mm height and 120 mm dia for working pressure 33000 volts complete all as specified.
S&F in repair disc type polymer insulator white,brown,grey insulator 150 mm height and 120 mm dia for working pressure 33000 volts complete all as specified.
Cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate in coping padestal to poles including provision of necessary form work finishing the exposed surface even and smooth complete all as specified. ( for pole)
Cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate in foundation filling & mass concrete for poles/struts/stays assembly including provision of necessary form work finishing the exposed surface even and smooth in cement mortar 1:3 complete all as specified. ( for pole)
Cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate in foundation filling & mass concrete for poles/struts/stays assembly including provision of necessary form work finishing the exposed surface even and smooth in cement mortar 1:3 and applying two coats of white wash to the portion of PCC muffs above ground level complete all as specified. ( for pole and stay)
M&L for removing LT/HT over head conductor from the insulator where ever required and restretching the same without any kink/bend upto permissible sag,binding it on insulator by means of binding wire and testing the LT/HT overhead line after completion as directed.(Note: Three/four runs of HT/LT overhead conductor for three phases and neutral shall be measured and paid as one length.)
M&L for painting of steel tubular pole upto 11 mtr length incl MS clamp , bracket, cross arms with two coat of alumnium paint after preparation of old painted surface and applying metallic primer , providing 03 nos alternative strip of 30 cm wide with black and yellow super quality enamel paint above embedded level and writing pole nos with 02 inch wide letter complete all as specified and directed. Note for item No : Necessary electric shutt down will be taken from the Dpt before commencing the work .
Supply and fix in replacing LT Pin type, porcelain, vitreous, white,brown or green insulator including one galvanised mild steel spindle, two gavanised iron washers and one galvanised iron nut, 50mm height, 65mm dia for 550 volts complete all as specified and directed.
Supply and fix in replacing Shackle Type, Porcelain, vitreous, white, brown or green insulator working voltage 1100 volt, height 75 mm and dia 90mm including galvanised mild steel straps, washers, insulator bolts, washers and nuts, of size
M&L in replacing LT line seperator made of PVC 4 line complete with screws, bolts , nuts all as specified and direted.
M&L for rectifying fault on HT line from Khaltsi area to Biamah area and lamayuru area on call with suficient electrician, Helpers and tools complete including transportation all as specified and directed. Note: Necessary shut down will be taken from department before repairing any HT line The electrical team shall attend the complaint within 24 Hrs . A deduction Rs 1000/- per every 24 Hrs shall be paid by the contractor in case of delay.
S&F in repair danger notice plate of 1.6 mm thick mild steel sheet,vitreous enamelled white with letters,figures and conventional skul and bones in signal red colour and fixed with MS clamps,bolts and nuts of approved size,for HT,25x20 cm in size.
Earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 32X6 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point all as shown in electrical plate No. 3 of SSR Part I of 2009.00 & as specified or indicated and testing on completion including exaction/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, I watering pipe of 20 mm bore medium grade and lugs, including galvanised iron strip 32X6 mm with GI protection pipe of 40 mm medium grade 7.5 meter long, etc complete all as specified.
Taking down carefully copper/ aluminium point wiring (light, fan, bell, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants , regulators, sockets light fitting etc for taking credit removing from site and making good disturbed surface etc.
Material and labour for point wiring with 1.5 sqmm single core PVC insulated , unsheathed FRLS multi stranded copper cable , 1100 volt grade with necessary termination board in and incl PVC heavy duty casing n caping ISI marked on wall/ceilings/conceiled in wooden paneling as required at site including 1.5 sqmm single core PVC insulated multistranded copper conductor cable green in colour as earth earth continuity conductor connected to common earth dolley as rquired at site along with metal flush box of suitable size to accommodate switch/sockets as per circuit incl hylom sheet and all accessories and making good the disturbed surfaces of wall/ ceiling etc for the following : - Note :- Colour coding for point wiring should be maintained at site. Incase of any deviation necessary recovery will be made as applicable.
(a) One light point/ one fan point/ Bell Point controlled by one switch.
(b) One 3 pin socket outlet, 5 Amp independent with other switches.
(c) One 3 pin socket outlet 5Amps on same board with other switches .
All as per item No 2 above but for point wiring for power point with 2.5 Sqmm FRLS PVC insulated unsheathed copper cable 1100 Volt gradewith necessary termination board in and incl PVC heavy duty casing n caping ISI marked on wall/ceilings/conceiled in wooden paneling as required at site including 1.5 sqmm single core PVC insulated multistranded copper conductor cable green in colour as earth earth continuity conductor connected to common earth dolley as rquired at site along with metal flush box of suitable size to accommodate switch/sockets as per circuit incl hylom sheet and all accessories and making good the disturbed surfaces of wall/ ceiling etc for the following : - Note :- Colour coding for point wiring should be maintained at site. Incase of any deviation necessary recovery will be made as applicable.
S & F in repair switch socket combination 15 amp ,230V, 50 Hz flush type all as specified.
S & F in repair Switch socket combination 5A , 230V, 50 Hz all as specified.
S&F in repair switch piano flush type single pole one way 5 amp , 230V, 50 Hz all as specified.
S&F in repair Batten holder PVC/ poly carbonate typen with cord grip cap incl taking old one all as specified
S&F in repair Bell electronic ding dong AC 230Volts 50 Hz all as specified.
S&F in repair bell push flush type single pole one way 5 amp , 230V, 50 Hz all as specified.
S & F in repair Ceiling rose 3 terminals complete all as specified & directed
S&F in replacment of decorative ultra slim polycarbonate LED 4 feet long 20/22 watts ,very high efficiency suited for T-8 tube luminare with system efficacy 110 lumen per watts ,and lumen package >= 2200 lumen , THD< 10 % high quality poly carbonate end cap in white finish and snap fitted to the housing, inbuilt driver incl copper connecting wire three core of suitable size upto connctor of ceiling rose complete all as specified and directed. .
S&F in replacement of wall mounted 10 watts LED batten 2 feet long comprising extruded aluminium heat shrink provided for efficient heat dissipation and integrated lectronic driver with aluminium housing , system efficiency of 110 lumen per watts and lumen package >= 1100 lumen , THD< 10 % incl copper connecting wire three core of suitable size upto connctor of ceiling rosecomplete all as specified and directed.
S&F in replace LED building security light fitting 35 watts made of pressure diecast aluminium housing with acrylic cover as diffuser with IP65 and IK -07 protection , THD<10%, lumen output >= 110 lumen per watts with integrated lectronic driver incl copper connecting wire three core of suitable size upto connctor of ceiling rose complete all as specified and directed.
S&F in replacing GI mounting pipe of building security lights of size 32 mm to 40 mm size upto 1.2 mtr length bend into sizes incl mounting clamps made of MS flat saddles, nut bolt and washers all as specified and directed .
M&L for replacing LED bulk head fittings of wattage 6 to 13 watts deigned for modern homes , glare free lights and easy to install snapfit installer complete including making good of surface complete all as specified and directed.
S&F in replace warm white/ white LED luminaire 600X600 mm,35/36 watt,220V recessed type lumen output >= 122 lumen per watts , THD < 10% environmental friendly , new generation , aesthetically designed , ultra modern with high brightness SMD LEDs as light source incl inbuilt drivers with high efficiency PMMA diffuser soft glare free light complete suitable for roof ceiling including connecting up with three core flexible copper conductor of suitable size all as specified and directed.
S&F in replacing distribution board double door made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 12 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 250 volts, flush to wall / fixed on surface incl making good of surface complete all as specified and directed incl taking down old one
S&F in replace distribution board double door made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 8 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 250 volts, flush to wall / fixed on surface complete incl making good all as specified and directed.
S&F in replacing distribution board double door made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 4 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 250 volts, flush to wall / fixed on surface complete all as specified and directed incl taking down old one
S&F in replacing distribution board double door made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 2 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 250 volts, flush to wall / fixed on surface complete all as specified and directed incl taking down old one
Material and labour for attending repairing any complaints like MCB trip/burnt, wiring short circuit, sumain wiring not getting continuity, earth wire brocken at any type on call complete all as specified and directed. Note : Minor matrerials like wires , themble, connectors, nut , bolt and screws deemed to be included in the quoted rates , but all major items will be measured and paid as per relevent sch items
M&L for repair/replacing PCC 1:3:6 using 20 mm graded stone aggregate of required shape incl necessary form work , rendering with cement mortar 1:4 finishing complete incl two coat of distumbering as per approved colour duly making surface preparation and two coat of cement primer all as specified and directed. of post top lantern/bollards incl necessary form works
S&F in replacement MCB DB TPN double door 4 way three phase vertical type , 415 volts with MCCB as incommer and MCB/ISOLATOR SP as outgoing incl three phase four wire copper strip bus bar of appropriate capacity complete all as specified and directed and comprising of the following ; INCOMMER (a) MCCB 4 Pole 100 AMPS AC 415 V 16 KA=01 No OUTGOING (a) MCB SP 63 Amps C curve - 04 Nos (b) MCB SP 40 Amps C curve - 08 Nos Note :- (i)The DB shall be of VTPN series (ii) The DB shall be flush fixed ,and making good the disturbed surface matching with existing specifications shall be part of job at no extra cost.(iii)connection of theMCCBs/ MCBs with cable shall be made through appropriate size pin /bottle type thimble -properly crimped.(iv) all the vacant holes of the DB shall be provided with blank plates of appropriate size. (v) double continuous earth wire shall be provided for each three phase DB from earthing mains dolly.
S&F in repair MCB single pole, 6 to 32 Amp 240 volt C curve 10 KA breaking capaity complete all as specified and directed incl taking down old one
S&F in repair MCB SPN 40 Amps,10 KA, 240 volt C curve IP 20 complete all as specified and directed incl taking down old one
S&F in repair MCB SPN 63 Amps,10 KA, 240 volt C curve IP 20 complete all as specified and directed incl taking down old one
M&L for taking down carefully point wiring any type light/bell/socket/power point along with all accessories and refixing in same location after wooden paneling /roof ceiling complete with all accessories to make it serviceable incl necessary making good work all as specified and directed at site .
Taking down old u/s submain wiring of any sizes complete incl conduits/PVC casing n caping all as specified & directed.
M&L for sub main wiring with two run of single core PVC insulated copper cable FRLS multi-stranded conductor 6 Sqmm drawn through in and including Non metalic PVC heavy duty PVC casing caping of suitable size as required at site with all accessories with one run of 6 Sqmm PVC insulated unsheathed copper conductor FRLS as earth wire ( green in colour ) , connected to common earth complete all as specified and directed. Note : 1. Two run of main copper conductor 6 sqmm size , one run of 6 sqmm earth wire and one run of PVC conduit/PVC casing n caping shall be measured as one unit length . 2. Proper colour coding shall be maintained as per IS code.
M&L for sub main wiring with two run of single core PVC insulated copper cable FRLS multi-stranded conductor 4 Sqmm drawn through in and including Non metalic PVC heavy duty PVC casing caping of suitable size as required at site with all accessories with one run of 4 Sqmm PVC insulated unsheathed copper conductor FRLS as earth wire ( green in colour ) , connected to common earth complete all as specified and directed. Note : 1. Two run of main copper conductor 4 sqmm size , one run of 4 sqmm earth wire and one run of PVC conduit/PVC casing n caping shall be measured as one unit length . 2. Proper colour coding shall be maintained as per IS code.
S&F in replacing LT cable junction boxes out of polycarbonate with glass fibre reinforced and size not less than 104x104x70 mm ( cable size upto 4 sqmm ) . The polycarbonate junction box shall be environmental friendly , recyclable , halogen and sylicon free, anti acid and anti corrosive with IP rating IP 67/69 in accordance with IEC 60529 weather proof UV resistant , rain water proof and temparature resistant . The gasket material of junction box shall be polyurethane and internally embedded. The junction box comprises of DIN rail and terminal for 3 phase . The degree of protection against mechanical load shall be in accordance with EN 50298-98 for IK 08 incl 5 pole terminals comany fitted and chromium plated clamps complete all as specified and directed. Cat part no :- KF 0404 B of Hensel or equivalent make in Seimens/GE/ABB
M&L for replacing 3 core copper flexible cable 2.5 sqmm PVC sheathed FRLS complete all as specified and directed .
Supply and fix in replace unsv casing and caping 25mm/PVC heavy duty including all fixing accessories complete all as specified and directed .
S&F 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor ,served with inner sheathing of PVC tape and overall PVC sheathed in service connections two core of size 10 sq mm flat or circular complete all as specified and directed
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing wire of size 4 mm dia by means of GI bolts/nuts/washers and protected by 15 mm bore GI light grade pipe upto test point or upto main switch board fixing with 02 Nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.(TPN DB-03 Nos)
Deduct Credit for Demolished/Dismantled material Rs (-) 1,01,845.00 (Minus) as listed in Schedule 'A' Sec-II (Credit Schedule) Note : Tenderers will not quote against this item being a tentative amount, to be considered to arrive at the 'Contract Sum'.
M/S ZTECH (BID ID -3395000)
SUMEET TRADING CORPORATION (BID ID -3395070)
M/S WEB COMPNAY (BID ID -3381058)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .