| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.2 LAccepted-AOC | L1 | Accepted-AOC Lowest bodder | |
| 2 | L2₹30.4 L+₹1.2 L (4.08%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹31.4 L+₹2.2 L (7.55%)Rejected-Finance 0 HISAR HISAR HARYANA 125004 UDYAM HR 06 0052049 | HISAR | HARYANA | 125004 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹34.7 L+₹5.6 L (19.0%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹35.5 L+₹6.3 L (21.7%)Rejected-Finance NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
11 Sept 2023, 6:00 pmClosed
GE (NORTH) TEZPUR
GE (NORTH) TEZPUR, C/O 99 APO
REPAIR/REPLACEMENT AND DAY TO DAY MAINTENANCE OF INTERNAL WIRING, LIGHT FITTINGS, SWITCH GEARS, FTL/CFL FITTINGS TO LED FITTINGS AND REPAIR/MAINT OF SOLAR WATER HEATERS, SUMMER APPLIANCES AND CONNECTED WORK AT AGE CHARDUAR AREA UNDER GE (N) TEZPUR
2023_MES_613626_1
GE(N)/TEZ/2023-2024/8762
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
GE (NORTH) TEZPUR
As per tender documents
8 documents required · 8 mandatory
₹500
GE (NORTH) TEZPUR
₹84,000
17 Nov 2023
14 Aug 2023
18 Sept 2023
14 Aug 2023
11 Sept 2023
28 Aug 2023
Amount
Disconnecting of ceiling fans of 1200/1400 mm sweep from ceiling rose/connector for cleaning,servicing /oiling and greasing of fan by using appropriate grade of oil/grease and re-hanging the same after proper cleaning and making connection with ceiling fan/connector with flexible wire of size 23/0076 copper conductor multi stranded as directed by Engr-in-Charge.
Disconnecting of ceiling fans of 1200/1400 mm sweep from ceiling rose/connector for re-winding,servicing /oiling and greasing of fan by using appropriate grade of oil/grease and replacing defective parts such as bush bearing , split pin rubber bush, capacitor etc and re-hanging the same after proper cleaning and making connection with ceiling fan/connector with flexible wire of size 23/0076 copper conductor multi stranded as directed by Engr-in-Charge. (NOTE :- Parts/spares will measured and paid separtely under respective item of the schedules).
Rewinding of ceiling fan 1200 mm sweep AC 230 volts single phase with super enamelled copper winding wire of appropriate / existing gauge / size including packing, insulating material soldering varnishing, assembling and testing material soldering varnishing, assembling and testing including transportation charges to and from contractor's workshop complete all as specified and directed.
Rewinding of ceiling fan 1400 mm sweep AC 230 volts single phase with super enamelled copper winding wire of appropriate / existing gauge / size including packing, insulating material soldering varnishing, assembling and testing material soldering varnishing, assembling and testing including transportation charges to and from contractor's workshop complete all as specified and directed.
S&F bearing of ceiling fans for ceiling fans of 1200/1400mm sweep to suit for different makes of fans of approved quality including necessary greasing complete all as specified and directed. Make- NBC/SKF/NORE.
S&F bushes gun metal suitable for ceiling fans 1200/1400mm sweep complete all as specified and directed.
S&F rubber bushes and reel type synthetic rubber with 14.5 mm hole suitable for fan hooks for hanging of ceiling fans complete all as specified and directed.
S&F split pins of galvanised iron 1/8" dia, 2 length all as approved by Engr in charge complete all as specified and directed.
S&F down rod 30cms long made out of heavy grade MS pipe with necessary threading at both ends holes as required with suitable matching colour of ceiling fan 1200/1400mm complete all as specified and directed.
S&F top/bottom canopy of required size complete with tightening screws complete all as specified and directed.
S&F condenser/capacitor suitable for 230 volts single phase ceiling fan 1200mm /1400 sweep of any make and quality of capacity 2.5 MFD complete all as specified and directed. Make- Bajaj/Havells/Usha.
S&F condenser/capacitor suitable for 230 volts single phase ceiling fan 1200mm /1400 sweep of any make and quality of capacity 3.15 MFD complete all as specified and directed. Make- Bajaj/Havells/Usha.
Supply & fixing BLDC 6 STAR ceiling fan 1200 mm sweep AC 230 volts single phase 50 HZ operated between 140V to 285V including making connection with three core PVC insulated 1100 volts grade multi stranded copper wire of appropriate size including testing complete all as specified.Make: ATOMBERG KALTRO EFFICIO or equivalent
Taking down exhaust fans any size, sealing cable end, and dismantling blade and removing fan and blade to contractor workshop for repair/overhauling/painting complete all as specified and directed.
Rewinding of exhaust fan 300mm to 450mm sweep AC 230 volts single phase with super enamelled copper wire of appropriate size including packing insulating material, soldering, varnishing, assembling and testing including transportation charges to and fro from contractor's workshop complete all as specified.
S&F ball bearing suitable for exhaust fan 300 to 450mm sweep of different make . Make of bearing NBC/SKF/NORE complete all as specified and directed
S&F condenser/capacitor suitable for 230 volts single phase exhaust fan 300mm to 450 sweep of any make and quality of capacity as per fan Make- Bajaj/Seimen/Tibcon/Usha complete all as specified and directed
S&F fan blade, complete with tightening bolts/screws, made of aluminium suitable for any make and colour of exhaust fan as directed at site by Engr -in-Charge.
Fixing only exhaust fan 250 mm to 450 mm and connecting up including provision of flexible copper cable 23/0.0076 from ceiling rose or connector to fan complete all as specified and directed.
Supply & fixing exhaust fan 450 mm sweep AC 230 volts single phase with louvers including making connection with three core PVC insulated 1100 volts grade multi stranded copper wire of appropriate size including testing complete all as specified.Make: Bajaj/CG
Supply & fixing exhaust fan fresh air 250/300 mm sweep AC 230 volts single phase with louvers including making connection with three core PVC insulated 1100 volts grade multi stranded copper wire of appropriate size including testing complete all as specified.Make: Bajaj/CG
Disconnecting / taking down water heaters (Geysers) of any make & capacity, horizontal or vertical type their existing locations, for carrying out overhauling / repairs from complete all as specified and directed.
Overhauling, repairing, reassembling, refixing, installation of water heaters / Geysers to their original position, making all necessary water & electric connections and testing complete all as specified and directed. (Parts renewed shall be measured and aid separately under appropriate items).
Supply only heating element 1.5 KW (ISI Marked) suitable for EXISTING geyser of 25 liters capacity, horizontal or vertical type any make all as specified and directed.
Supply only heating element 2.0 KW (ISI Marked) suitable for EXISTING geyser of 25 liters capacity, horizontal or vertical type any make all as specified and directed.
Supply only thermostat, minimum 300 mm long, suitable for any make & type of geyser 25/50 liters capacity horizontal or vertical type all as specified and directed.
Supply only indicating lamp for geysers of any type make & capacity all as specified and directed.
Supply only door assembly comprising of inlet & outlet thermostat housing with gasket complete with bolts, nuts, washers, washers screws & packing etc. suitable for 25 liters capacity horizontal or vertical geysers all as specified and directed.
Supply only door assembly comprising of inlet & outlet thermostat housing with gasket complete with bolts, nuts, washers, washers screws & packing etc. suitable for 50 liters capacity horizontal or vertical geysers all as specified and directed.
Supply and filling up glass wool for geysers of 25 ltrts capacity all as specified and directed.
Supply and filling up glass wool for geysers of 50 ltrts capacity all as specified and directed.
M&L for repairing leakage of inner copper tank of geyser (any make), 25 litres capacity by brazing including all necessary denting etc. complete all as specified and directed.
M&L for repairing leakage of inner copper tank of geyser (any make), 50 litres capacity by brazing including all necessary denting etc. complete all as specified and directed.
Renewal of inner stainless steel container of geyser (any make), 25 liters capacity by brazing including all necessary asseccories etc. complete all as specified and directed.
Renewal of inner stainless steel container of geyser (any make), 50 liters capacity by brazing including all necessary asseccories etc. complete all as specified and directed.
S&F to outer cell heavy duty suitable for 25 Ltr capacity geyser complete with 02 Nos MS adjustable all as specified and directed.
S&F to outer cell heavy duty suitable for 50 Ltr capacity geyser complete with 02 Nos MS adjustable all as specified and directed.
S&F top cover of geyser suitable for 25 Ltr cap complete with screw, washer etc all as directed and specified.
S&F (in repair) for PVC connection 15 mm die with brass ferule both end length 450 mm complete all as specified and directed.
Supply only twisted flexible cord PVC insulated, 3 core, 23/0.0076 complete all as specified and directed.
S&F (in repairs) of fancy type chromium plated stop cock with brass spindle & with crutch or butterfly handle screwed down high pressure suitable for 15 mm bore GI tubing all as specified and directed.
S&F Bib taps, cast copper alloy with crutch handle, screwed for 15 mm bore dia iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F fuseable plug suitable for any type of storage water heater of any make capacity complete all as specified and directed.
S&F (in repairs) non-return valve, gun metal, suitable for 15 mm bore GI tubing complete all as specified and directed.
S&F pressure releasing safety valve ISI marked complete all as specified and directed.
Supply and fixing plug top polycarbonate 3 pin, 16 Amp (Cat No. 38637 of Anchor or equivalent of other specified a make) all as specified and directed.
Supply, installation testing and commissioning of storage type water heater 25 ltrs capacity vertical mounting type complete made out of CRCA outer body, heating element,thermostat,thermal cut out, glass wool etc. complete including making necessary electrical connections with suitable size copper multistranded cable all as directed by EIC.
Dismantling any type and capacity of geysers and re-fixing after descalling of geyser tank 25/50 Ltr capacity including geysers and element holding assembly complete all as specified and directed.
S&F Sheet metal enclosures Single door SPN, 2 ways suitable for mounting MCB/complete all as specified and directed.
S&F MCB of the following rating and to be housed in DBs catered here in after complete all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are including in unit rate of each MCB of any rating) (a) SP, 6 to 32 Amps, 240 Volts (Cat No. 6032 31 to 6032 37 of legrand or equivalent of other specified make).
Taking up or down steel tubing and connections, including removal of 15 mm bore all as specified (Excavation and earthwork measured and paid separately).
Supplying, laying, jointing and testing 15 mm nominal bore steel water tubes, 'medium grade', galvanised, with all fittings, laid in trenches complete all as specified.
Refixing old steel tubing and connections in new and old position walls, ceiling, floors etc.) of following bore all as specified.
S&F GI nipple, 15 mm bore, medium grade upto 150 mm length all as specified and directed.
Taking out compressor from water cooler of any make by cutting of suction and discharge lines for carrying out necessary repairs to the water cooler base such as renewal of MS angle iron , base plate, nuts , washers, bolts,rubber grooves and refixing it including painting with two coats of synthetic enemeeled paint of existing shade of 40/40 litres/Hrs capacities of water coolers all as specified and directed.
Taking out compressor from water cooler of any make by cutting of suction and discharge lines for carrying out necessary repairs to the water cooler base such as renewal of MS angle iron , base plate, nuts , washers, bolts,rubber grooves and refixing it including painting with two coats of synthetic enemeeled paint of existing shade of 40/80 litres/Hrs capacities of water coolers all as specified and directed.
Taking out compressor from water cooler of any make by cutting of suction and discharge lines for carrying out necessary repairs to the water cooler base such as renewal of MS angle iron , base plate, nuts , washers, bolts,rubber grooves and refixing it including painting with two coats of synthetic enemeeled paint of existing shade of Upto 120 Lts capacity capacities of water coolers all as specified and directed.
Dismantling of unserviceable compressor of any make/model from water cooler including disconnecting suction / Discharge copper tubing and supply & fixing new compressor (sealed unit) with nuts, bolts, rubbers grommet and washer, connecting copper tubing by welding flare nuts, detecting leak and repairs if any flushing and pressure testing by nitrogen & etc. vacuumising, charging with non CFC refrigerant gas of 40/40 ltrs/Hrs capacity water cooler of any make & Model complete all as directed by Engineer-in-Charge.
Dismantling of unserviceable compressor of any make/model from water cooler including disconnecting suction / Discharge copper tubing and supply & fixing new compressor (sealed unit) with nuts, bolts, rubbers grommet and washer, connecting copper tubing by welding flare nuts, detecting leak and repairs if any flushing and pressure testing by nitrogen & etc. vacuumising, charging with non CFC refrigerant gas of 40/80 ltrs/Hrs capacity water cooler of any make & Model complete all as directed by Engineer-in-Charge.
Dismantling of unserviceable compressor of any make/model from water cooler including disconnecting suction / Discharge copper tubing and supply & fixing new compressor (sealed unit) with nuts, bolts, rubbers grommet and washer, connecting copper tubing by welding flare nuts, detecting leak and repairs if any flushing and pressure testing by nitrogen & etc. vacuumising, charging with non CFC refrigerant gas of 120 ltrs/Hrs capacity water cooler of any make & Model complete all as directed by Engineer-in-Charge.
Supply & fixing (in repairs) CP Brass push cock (inner or outer threaded) of 15 mm bore size complete all as directed by the Engineer-in-Charge.
Renewal of 32 mm PVC pipe with clip and strainer tee Elbow all as specified and directed by Engineer-in-Charge.
Supply & fixing (in repairs) starting relay for 40 ltrs/hr water cooler complete all as specified and directed .
Supply & fixing starting relay for 80 ltrs/hr water cooler complete all as specified and directed .
Supply & fixing running capacitor (conforming to IS:2993 - 1975) AC 240 volts in plastic container of 10/15 mfd capacities complete all as specified and directed.
Supply & fixing running capacitor (conforming to IS:2993 - 1975) AC 240 volts in plastic container of 25 mfd capacities complete all as specified and directed.
Supply & fixing overload protector for 40/80 ltrs water cooler complete all as specified and directed
S & F wiring loom for water cooler all as directed by Engineer-in-Charge complete all as specified and directed.
S & F Thermostat long/short tail for water cooler all as directed by Engineer-in-Charge complete all as specified and directed .
Taking out defective blower motor with blade and supply & fixing new blower motor with blade AC 240 volts, 50 HZ single phase, for water cooler 40/80 ltrs complete all as specified and directed.
S&F of condensing coil for 40/80 ltrs water cooler of any make all as specified and directed by Engineer-in-Charge.
M&L for disconnecting of water cooler of 40/80 ltrs capacities from its position, taking out water from its water tank, cleaning of water tank by washing with washing powder and with fresh water externally and internally and spray painting with synthetic enamel paint of approved tint/colour to all painted surface of water cooler after preparation of old painted surfaces without disturbing the components & wiring etc. complete and reconnceting all as specified and directed by Engineer-in-Charge.
S&F in repairs water tray for water cooler of 40/80 ltrs made out of stainless steel complete and connecting to draining system complete all as specified and directed.
Renewal of PVC inner liner of front door of 165/ 170 / 180 litres capacities of refrigerators including glass wool packing and making other petty repairs complete all as specified.
Renewal of PVC inner liner of front door of 286 litres/ 300 litres / 310 litres litres capacities of refrigerators including glass wool packing and making other petty repairs complete all as specified and directed.
M&L for spray painting with two coats of synthetic enamel paint of approved tint/colour to outer surface of refrigerator of 165/180 litres capacities on all three outer sides after preparation of old painted surfaces and without disturbing the components & wiring etc. complete as specified and directed by Engineer-in-Charge.
M&L for spray painting with two coats of synthetic enamel paint of approved tint/colour to outer surface of refrigerator of 286 /300/310 litres capacities on all three outer sides after preparation of old painted surfaces and without disturbing the components & wiring etc. complete as specified and directed by Engineer-in-Charge.
Checking of leakage in refrigerant system of refrigerator of 165 / 170 / 180 litres capacities by putting nitrogen pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuuming the system including charging refrigerant gas Non CFC in required quantity all as directed by Engineer-in-Charge.
Checking of leakage in refrigerant system of refrigerator of 286 /300 / 310 litres capacities by putting nitrogen pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuuming the system including charging refrigerant gas Non CFC in required quantity all as directed by Engineer-in-Charge.
S&F starting relay, open type for refrigerator of capacity 165/170/180/300/310 litres all as directed by Engineer-in-Charge.
S & F over load protector for 1/6 HP refrigerator of capacity 165/300 /310 litres all as directed by Engineer-in-Charge.
S & F thermostat defrost type for refrigerator all as directed by Engineer-in-Charge.
S & F thermostat non defrost type for refrigerator all as directed by Engineer-in-Charge.
S & F door gasket for refrigerator of 165 / 170 / 180 litres capacities, any make all as directed by Engineer-in-Charge
S & F door gasket for refrigerator of 286 /300 /310 litres capacities, any make all as directed by Engineer-in-Charge
Supply & fixing vegetable basket with glass suitable for refrigerator of 165 / 170 / 180 litres capacities all as specified and directed by Engineer-in-Charge.
Supply & fixing vegetable basket with glass suitable for refrigerator of 286 /300 / 310 litres capacities all as specified and directed by Engineer-in-Charge.
S & F defrost tray (Plastic) as per sample for 165 / 170 / 180 litres capacities of refrigerator complete all as specified and directed
S & F defrost tray (Plastic) as per sample for 286 /300 / 310 litres capacities of refrigerator complete all as specified and directed
S&F copper capallery for water cooler, refrigerator and deep freezer of any sizy / capacity complete all as specified and directed.
Checking of leakage in refrigerant system of deep freezer of 200 / 300 litres capacity by putting nitrogen pressure, identifying the leak, rectifying the leak/defects by brazing a. nd testing, vacuuming the system including charging refrigerant gas Non CFC in required quantity all as directed by Engineer-in-Charge.
S&F of Fan Motor of deep freezer, 230Volts rating, AC, Single Phase, 50 Hz including disconnection and reconnecting and testing complete all as specified
Renewal of Door gasket of deep freezer of any make of following capacities 300/310 litres complete all as specified and directed.
Supply and fixing starting capacitor of 80-120 Mfd capacity in plastic /metal container all as directed.
Supply and fixing starting capacitor of 120-150 Mfd capacity in plastic /metal container all as directed.
Supply and fixing running capacitor 36 Mfd to 50 Mfd capacity in plastic container all as directed.
Supply and fixing starting relay for 1.5TR/2 TR compressor complete all as specified and directed.
Supply and fixing over load protector for 1.5TR/2TR compressor all as directed.
Supply and fixing thermostate switch for 1.5TR/2TR split AC all as directed.Make:Indfoss
Supply and fixing swing motor for 1.5TR/2TR Indoor unit of any make of existing capacity all as directed.
Supply and fixing Swing Motor for 1.5TR/2TR window type AC of any make/model all as directed.
Supply and fixing reverse cycle solenoid valve in split/window type AC 1.5 /2 TR capacity with necessary extension to suction / discharge copper tubbing & toggle switch complete all as directed .
Supply and fixing suction copper pipe line heavy duty 1/2'' dia with puff insulation and flair nuts from indoor to outdoor unit of split AC 1.5 /2 TR capacity all as specified and directed.
Supply and fixing suction copper pipe line heavy duty 1/4'' dia with puff insulation and flair nuts from indoor to outdoor unit of split AC 1.5TR/2TR capacity all as specified and directed.
Supply and fixing copper Gas filter for AC 1.5TR/2TR capacity all as specified and directed.
Supply and fixing PVC pipe nylon imbraided 15 mm dia for condenser water drain with clamps/ concealed in wall all as specified and directed.
Dismantling of defective indoor unit of 1.5 TR capacity split type AC and supply & fixing indoor unit of the same capacity with blower motor . Front grill and connecting the copper tubing by brazing detecting leak and rectifying the same and recharging with Non CFC refrigerant gas as required the unit in wall/ ceiling mounted all as specified and directed.
Dismantling of defective condensing unit of split type AC of 1.5 TR capacity and supply & fixing new condensing unit complete with condensing coil, coil frame , wiring kit and running capacity , relay condensing motor with blade complete all as directed. Make:AS per site requirement.
Material & labour for servicing of indoor and outdoor unit by means of electric blower and water under pressure cleaning & washing of condensing coil / cooling by soap solution or recommended chemical, oiling & greasing of moving parts such as blower motor etc. complete of 1.5 TR capacity window type AC all as specified and directed.
Material & labour for servicing of indoor and outdoor unit by means of electric blower and water under pressure cleaning & washing of condensing coil / cooling by soap solution or recommended chemical, oiling & greasing of moving parts such as blower motor etc. complete of 2 TR capacity window type AC all as specified and directed.
Dismantling of burnt blower motor of 1.5 TR split AC (indoor unit) and supply & fixing blower motor of same manufacturer of AC of make of AC Carrier/Voltas /Blue star as per sample complete all as specified and directed.
Supply and charging (Top up) the AC unit of 1.5 TR/ 2 TR split type AC unit with Refrigeration Gas non CFC compatible to R-22/R-32 in required Qty complete all as specified and directed.
Supply and fixing of suction valve size 1/2" complete all as specified and directed.
Supply and fixing of discharge valve size 1/4'' complete all as specified and directed.
Supply and fixing of rubber coupling mounting for blower motor of split type AC all as per directed by EIC ( Make: - Carrier /Voltas).Make:Carrier/Voltas
Supply and fixing of air filter made out Nylon suitable for 1.5 TR split/window AC capacity air conditioners of any Make and model all as directed.
Carrying out pressure leak test of split Acs 1.5 /2.0 TR by Nitrogen gas pressure for detecting leak in cooling unit refrigerant pipe and repairing the leak by wilding or brazing of cooling unit and refrigerant pipe , putting under pressure for leak checking after repairs of leak pipe including gas charging transporting & carrying out Tools and Plant required at site all as specified and directed.
Carrying out pressure leak test of 1.5 TR window AC by Nitrogen gas pressure for detecting leak in cooling unit refrigerent pipe and repairing the leak by welding or brazing of cooling unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe including gas charging transporting & carrying out Tools and Plant required at site all as specified and directed.
Dismantling of defective worn out wiring of indoor unit of window/split AC of capacity 1.5 TR/2TR, Supply and fixing PCB ( Printed circuit Board) & Visual Eye demo plate remote hand set to suit/match the existing system all as specified and directed.Make:LG/Universal
Compressor reciprocating suitable for window type AC 1.5 TR (Original sealed unit is to supply) of specified make as approved by GE.
S&F in replacement sheet metal enclosure with metallic socket and MCB single pole 32 Amp and metallic plug top connected from mains to AC all as specified and directed .
S&F repairs metallic plug top of 16 Amps connected from mains to AC all as specified and directed. ( Make : Havells/ Legrand/ Hager).Make:Legrand
Dismantling of defective cooling coil of 1.5 TR window type AC of any make and S&F cooling coil for AC, detecting the leakage with N2 Gas , reconnecting in to the system complete all as specified and directed.
Dismantling of defective condensing coil of 1.5 TR window type AC of any make and S&F condensing coil for AC, detecting the leakage with N2 Gas, reconnecting in to the system complete all as specified and directed.
Dismantling of burnt blower motor of 1.5 TR /2 TR window AC and supply & fixing new blower motor, double shaft, 1/6 or 1/8 HP as per sample complete including making necessory electrical connection with suitable size copper conductor wire all as specified and directed.
Dismantling of burnt blower motor of 1.5 TR/ 2 TR split AC ( outdoor unit) and supply & fixing new blower motor, as per sample complete including making necessory electrical connection with suitable size cooper conductor cable all as specified and directed.Make:LG
Supply and fixing of aluminium blower / fan blade with alminium alloy bush, screw for window Acs complete as required at site complete all as directed.
Supply and fixing PVC Knob of window type AC complete all as specified and directed.
Supply and fixing repairs front grill quantity for window AC of 1.5 TR /2TR of Make National / Cosmo all as specified and directed.
Supply and fixing of PVC insulated three core stranded copper cable of size 80/20 all as specified and directed.
M&L for servicing of window type AC 1.5 TR/2.0 TR capacity by means of electric blower and water under pressure cleaning & washing of condensing coil/cooling coil by soap solution or recommended chemical, coiling & greasing of moving parts such as blower motor etc complete of following capacity all as specified and directed.
Supply and fix refrigerant gas Non CFC equivalent to R-22/R-32 a in returnable sealed cylinder all specified and directed.
Collection of unserviceable voltage stabilizers of any make of 1 KVA capacities from AGE store yard & transporting it to local workshop of the contractor, dismantling the stabilizer for repairs of the defective parts/ spares & reassembling including repair of defective screws, rubber shoes, testing & painting with two coats of synthetic enamelled paint after removing old paint and repairs body etc. depositing back to MES stores yard all as directed by EIC. (Note :- Spares/ parts renewed shall be paid for separately under respective items at appropriate rates).
Collection of unserviceable voltage stabilizers of any make of 2 KVA capacities from AGE store yard & transporting it to local workshop of the contractor, dismantling the stabilizer for repairs of the defective parts/ spares & reassembling including repair of defective screws, rubber shoes, testing & painting with two coats of synthetic enamelled paint after removing old paint and repairs body etc. depositing back to MES stores yard all as directed by EIC. (Note :- Spares/ parts renewed shall be paid for separately under respective items at appropriate rates).
Collection of unserviceable voltage stabilizers of any make of 4 KVA capacities from AGE store yard & transporting it to local workshop of the contractor, dismantling the stabilizer for repairs of the defective parts/ spares & reassembling including repair of defective screws, rubber shoes, testing & painting with two coats of synthetic enamelled paint after removing old paint and repairs body etc. depositing back to MES stores yard all as directed by EIC. (Note :- Spares/ parts renewed shall be paid for separately under respective items at appropriate rates).
Collection of unserviceable voltage stabilizers of any make of 5 KVA capacities from AGE store yard & transporting it to local workshop of the contractor, dismantling the stabilizer for repairs of the defective parts/ spares & reassembling including repair of defective screws, rubber shoes, testing & painting with two coats of synthetic enamelled paint after removing old paint and repairs body etc. depositing back to MES stores yard all as directed by EIC. (Note :- Spares/ parts renewed shall be paid for separately under respective items at appropriate rates).
Supply only relay 25/30 Amps 24 Volts for 4 KVA/5KVA voltage Stabilizer all as specified and directed. (Make :- Dunmag, Eaglemen, Powerman)
Supply only Relay for 1KVA/2 KVA voltage Stabilizers all as specified and directed. (Make :- Dunmag, Eaglemen, Powerman)
Supply and fixing connector for IN-Out supply of voltage stabilizer 32 Amps with earth connection all as specified and directed.
Supply and fixing porcelain cutout of same size capacity as existing of 16 Amp each connection all as specified and directed.
Supply and fixing porcelain cutout (Kit-Kats) 32 Amps/240 volts all as specified and directed.
Supply and fixing indication lamp in voltage stabilizers of any capacity all as specified and directed.
S&F 2 Meter long conductor cable 3 core PVC insulated and sheathed 80/0.20 (2.5 sqmm) size duly fitted with 3 pin top, 20 Amps all as specified.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed.
Material and labour for point wiring with 1.5 sqmm (nominal area) PVC insulated and sheathed multistranded copper conductor cable FRLSH 1100 volts grade drawn in and including PVC casing & capping of suitable size including all accessiries fixed to wall/ceiling including PVC closed recessed boxes ISI marked with 3.00 mm thick plastic laminated sheet top cover as per manufacturer's design for mounting of switches, sockets or regulators etc including 1.50 sqmm (nominal area) PVC insulated and sheathed multistranded copper conductor cable FRLSH 1100 volts grade single core as earth continuity conductor and connected to common earth dolly for following:- Note:These point wiring is not necessary to be full bldg part it may or part of bldg. (a) One light /fan point controlled by one switch.
Material and labour for point wiring with 1.5 sqmm (nominal area) PVC insulated and sheathed multistranded copper conductor cable FRLSH 1100 volts grade drawn in and including PVC casing & capping of suitable size including all accessiries fixed to wall/ceiling including PVC closed recessed boxes ISI marked with 3.00 mm thick plastic laminated sheet top cover as per manufacturer's design for mounting of switches, sockets or regulators etc including 1.50 sqmm (nominal area) PVC insulated and sheathed multistranded copper conductor cable FRLSH 1100 volts grade single core as earth continuity conductor and connected to common earth dolly for following:- Note:These point wiring is not necessary to be full bldg part it may or part of bldg. (b) One bell /buzzer point controlled by one buzzer switch.
Material and labour for point wiring with 1.5 sqmm (nominal area) PVC insulated and sheathed multistranded copper conductor cable FRLSH 1100 volts grade drawn in and including PVC casing & capping of suitable size including all accessiries fixed to wall/ceiling including PVC closed recessed boxes ISI marked with 3.00 mm thick plastic laminated sheet top cover as per manufacturer's design for mounting of switches, sockets or regulators etc including 1.50 sqmm (nominal area) PVC insulated and sheathed multistranded copper conductor cable FRLSH 1100 volts grade single core as earth continuity conductor and connected to common earth dolly for following:- Note:These point wiring is not necessary to be full bldg part it may or part of bldg. (c) One 3 pin socket outlet 5 Amps on same board with other switches.
Material and labour for point wiring with 1.5 sqmm (nominal area) PVC insulated and sheathed multistranded copper conductor cable FRLSH 1100 volts grade drawn in and including PVC casing & capping of suitable size including all accessiries fixed to wall/ceiling including PVC closed recessed boxes ISI marked with 3.00 mm thick plastic laminated sheet top cover as per manufacturer's design for mounting of switches, sockets or regulators etc including 1.50 sqmm (nominal area) PVC insulated and sheathed multistranded copper conductor cable FRLSH 1100 volts grade single core as earth continuity conductor and connected to common earth dolly for following:- Note:These point wiring is not necessary to be full bldg part it may or part of bldg. (d) One 3 pin socket outlet 5 Amps on indpendent board.
M&L wiring for one 3 pin socket outlet 15 amps on independent board using 2.5 Sq mm nominal cross sectional area multistranded copper conductor, PVC insulated sheathed cables in and including casing & capping of suitable size with fittings complete fixed to wall/ceiling including PVC closed recessed boxes confirming to IS-14772-20000 for mounting of switches/sockets etc and 2.5 Sq mm nominal cross sectional area multistranded copper conductor PVC insulated sheathed earth wire and connecting to earth dolly by means of screws, washers complete all as specified and directed.
Supply and fix switch piano flush type single pole, one way, 5/6 Amps complete all as specified and directed.
Supply and fix socket 2 in one , 5 pin 5 Amps flush type, universal complete all as specified and directed.
Supply and fix Switch socket combination 2 in one , 5 pin 5 Amps flush type, universal complete all as specified and directed.
Supply and fix of switch socket combination 2 in one , 5 pin 5 Amps & 15 Amps flush type, universal complete all as specified and directed.
Supply and fix bell push flush type 5 Amps complete all as specified and directed.
S & F call bell suitable for single phase, AC, 240 volts complete all as specified and as directed.
S & F Bayonet plastic lamp holder, 2 A, 250 V, ordinary, backplate, non-switched, unenclosed, without T marking, B22d complete all as specified and as directed.
S & F step type electronic fan regulator, capacitor type, 100 watt, 240 volts, 50 Hz, single phase, flush type on the existing phenolic laminated sheet complete all as specified and as directed.
S & F ceiling roses, 6A, 240 V, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed.
Supply and fixing surface and wall mounted LED T/L Fittig with wide angle profile high lumen with efficiency of 100 lumens batten extruded aluminium housing provided for efficient heat dissipation with polycarbonate housing & integrated electronic driver including LED tube light 20 watt 6500K 4 feet complete all as specified and directed. Make: Havells CAT Part No LHEXAPP7UN1W020 HNSCode 9405
S& F Recess mounted SQUARE shaped 2"x2" size LED downlighter with durable housing with AIuminium heat sink with PC diffuser in white powder coated finish with integrated driver to give glare free light with removable driver 24 W LED 6000K complete all as specified and directed. Make Havells Cat Part No PLANO2X2PLR24WLED840S
S& F Recess mounted SQUARE shaped 2"x2" size LED downlighter with durable housing with AIuminium heat sink with PC diffuser in white powder coated finish with integrated driver to give glare free light with removable driver 36 W LED 6000K complete all as specified and directed. Make Havells Cat Part No PLUTONEO2X2PLR34WLED840S
Supplying and fix sheet metal enclosure for DB’s when MCB’s to be used of 240 volt 4 way with 200 amps rated bus bar SPN double door complete all as specified and directed. : MCB Should be fix in separate ktems.
Supply and fix sheet metal enclosure for DB’s when MCB’s to be used of 240 volt 8 way with 200 amps rated bus bar SPN double door complete all as specified and directed.Note : MCB Should be fix in separate ktems.
Supplying and fix sheet metal enclosure for DB’s when MCB’s to be used of 240 volt 2 way with 200 amps rated bus bar SPN double door complete all as specified and directed. : MCB Should be fix in separate ktems.
S&F MCB SP 6-32 amps, 10KA, 240V rating, to be housed in DBs catered here in before complete all as specified and as directed. (Make : L&T Cat No. BB10060C, BB10100C, BB10200C, BB10320C, Schneider, ABB, Havells or equivalent)
S&F MCB SPN 32 Amps 10 KA, ‘C’ Curve including connection with suitable size aluminum /copper lugs complete all as specified and directed by Engr-In-Charge. (Make:- L&T Cat no BB20320C, Schneider ABB ,Havells or equivalent)
Dismantling Fan/Exhaust Fan refixing the same in proper position and Hanging only ceiling fan (M.D.supply) and connecting upincluding provision of cable from ceiling rose or connector to fan all as specified and directed by engineer in charge.
M&L for providing fan hook made out of MS round bars of 20 mm dia cut to size and made to shape hanging from roof supporting bars to the required length up to the ceiling level including shackle type rubber bush, MS clamp, nuts, bolts, washers etc, complete all as specified and as directed.
Supply and fix ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor with 3 Star enegy saving including making connection with three core PVC insulated 1100 volts grade multi stranded copper wire of appropriate size including testing complete all as specified.Make:USHA cat Part No-Technix plus 3 Star
M & L for submain wiring with two runs of PVC insulated multistranded, copper coductor of size 4 Sqmm cable single core 1100 Volts Grade and one run of earth continuity conductor cable of 4 Sq mm solid strand cable drawn in and incl 30/32 mm PVC casing caping complete all as specified and as directed. Note:- 2 run of 4sqmm cable+ 1 run of 4sqmm earthed cable+ 1 run of casing capping shall be measured as one unit.
M & L for submain wiring with two runs of PVC insulated multistranded, copper coductor of size 6 Sqmm cable single core 1100 Volts Grade and one run of earth continuity conductor cable of 6 Sq mm solid strand cable drawn in and incl 30/32 mm PVC casing caping complete all as specified and as directed. Note:- 2 run of 6sqmm cable+ 1 run of 6sqmm earthed cable+ 1 run of casing capping shall be measured as one unit.
Supply and fix MCB changeover 63 Amps, 10 KA , C Series complete all as specified and directed. Note:- MCB Rating shall be suitable to the existing DB.Make-havelles cat Part No-DHMGODPX063 or equivalent
S&F metal clad socket out let with MCB three pole(3 P) 20 Amp including sheet metal enclosure complete 2nd class hard wood wooden board including complete electrical connection by proper size of copper lugs complete all as specified and directed.Havells Cat No DHDPUTN020 / DHDPUTN030
S&F metal clad socket out let with MCB two pole(P+N) 20 Amp including sheet metal enclosure complete 2nd class hard wood wooden board including complete electrical connection by proper size of copper lugs complete all as specified and directed.Make Havells cat part No DHDPUSN020/DHDPUDP020
M&L for earthing with galvanised iron earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metre below ground level) with top edge of the earth plate not less than 1.5 metre below ground level surrounded from all sides 15 mm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using earth lead GI wire 4mm dia(8 SWG) by means of bolts, nuts, check nuts and washers of galvanised iron or steel connected to common earth dolly and protected by galvanised iron light grade pipe 15 mm bore in wall/floor and including 20 mm galvanised pipe for watering with funnel and wire mesh all as specified or indicated including excavation and connected earth work, in soft/loose soil, PCC 1:3:6 type C1 using 20mm graded stone aggregate as in pit and RCC 1:2:4 type B1 cover for earth pit cover reinforced with 8 mm dia TMT Bars @ 75mm C/C both ways and with handle made out of 08mm dia bars, GI funnel, strainer, including alternate layer of charcoal dust and common salt complete all as shown in electrical plate No 3 of SSR Part I and testing on completion , complete all as specified and directed.
Supply, fixing and passing through service bracket, 1100 Volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart incl 4mm suspension wire one twin core cable of size 6 Sqmm including taking down old complete all as specified.
Supply, fixing and passing through service bracket, 1100 Volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart incl 4mm suspension wire one twin core cable of size 10 Sqmm including taking down old complete all as specified.
Supply, fixing and passing through service bracket, 1100 Volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart incl 4mm suspension wire one twin core cable of size 16 Sqmm including taking down old complete all as specified.
Supply only 15W LED new adore 15W B22 cool day light ball lamp all as specified and directed. Make HavellsCat No CLASSYLED 15 W B22CDL 3 STAR
Supply only 13 W LED new adore 13W B22 cool day light ball lamp all as specified and directed. Make HavellsCat No CLASSYLED 13 W B22CDL 3 STAR
Supply only 10 W LED new adore 10 W B22 cool day light ball lamp all as specified and directed. Make HavellsCat No LED ADORE PLUS 10 W B22 CDL 2 STAR LAMP Code-LHLDDDEAIA5R010
Supply Only Insulation tap of Red,yellow,blue ,green or black colour for day to day complain and wiring working at 240 V ac and for phase must be colour and for neutral must be black colour .
Supply only switch piano flush type single pole, one way, 5/6 Amps complete all as specified and directed.
Supply only Recess mounted SQUARE shaped 2"x2" size LED downlighter with durable housing with AIuminium heat sink with PC diffuser in white powder coated finish with integrated driver to give glare free light with removable driver 24 W LED 6000K complete all as specified and directed. Make Havells Cat Part No PLANO2X2PLR24WLED840S
Supply only Recess mounted SQUARE shaped 2"x2" size LED downlighter with durable housing with AIuminium heat sink with PC diffuser in white powder coated finish with integrated driver to give glare free light with removable driver 36 W LED 6000K complete all as specified and directed. Make Havells Cat Part No PLUTONEO2X2PLR34WLED840S
Supply only fan capacitor, AC 230 V, 2.5 MFD complete all as specified and directed.Make- Havells Cat Part- QHPCWC5002X5 or equivallent
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm. complete including provision of PVC insulated copper multi starnded three core flexible cable for making necessary electrical connections from ceiling rose to connector all as required at site. Necessary hole cutting properly and fixing deemed to be included in quoated rate no extra cost willbe provided.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm. complete including provision of PVC insulated copper multi starnded three core flexible cable for making necessary electrical connections from ceiling rose to connector all as required at site. Necessary hole cutting properly and fixing deemed to be included in quoated rate no extra cost willbe provided.
Supply only PVC casing & capping with fittings , ISI marked, 25 mm size included necessary clipping and jointing material as required complete all as specified and directed i by engineer in charge.Make-Prestoplast
Supply only PVC casing & capping with fittings , ISI marked, 32 mm size included necessary clipping and jointing material as required complete all as specified and directed i by engineer in charge.Make-Prestoplast
Supply only FRLSH PVC insulated, single core, 1100 Volts, 1.5 Sqmm complete all as specified and directed. Make- Havells . Cat No- WHFFFN…A11X5
Supply only cable FRLSH PVC insulated, single core, 1100 Volts, 2.5 Sqmm complete all as specified and directed. Make- Havells . Cat No- WHFFFN…A12X5
Supply only cable FRLS PVC insulated, single core, 1100 Volts, 4.0 Sqmm complete all as specified and directed. Make- Havells . Cat No- WHFFFNA14X0
Supply only FRLS PVC insulated, single core, 1100 Volts, 6.0 Sqmm complete all as specified and directed. Make- Havells . Cat No- WHFFFNA16X0
M/S JALALUDDIN AHMED
Raj Enterprise
DRISTEE ASSOCIATES
PURBANCHAL BUILDERS
M/S L N ENTERPRISE
M/S RSB ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .