Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.0 LAccepted-AOC MEDICAL COLLEGE KOTTAYAM PHASE I GENERAL ELECTRICAL WORK ADDITIONAL WORKS OF BASEMENT FLOOR KERALA KL | L1 | Accepted-AOC LOWEST TENDER | |
| 2 | L2₹10.5 L+₹50,082 (5.01%)Rejected-AOC HARIBHAVAN NORTH ARIYAD P O ALAPPUZHA | L2 | Rejected-AOC SECOND LOWEST TENDER |
Tender Value
₹10.3 L
EMD Value
₹25,900
Closing Date
14 Jul 2020, 6:00 pmClosed
AE
AE, LSGD, Elikulam GP
Panchayat Office Building Electrification and Networking
2020_LSGD_367508_1
01/AE/Elikulam/Tender/2020-21
Open Tender
Electrical Works
Item Rate
120 days
Ward 13
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,352
online
₹25,900
24 Aug 2020
6 Jul 2020
16 Jul 2020
6 Jul 2020
14 Jul 2020
6 Jul 2020
Amount
Part I-Electrification (Approved list of make of materials are seperately attached)
Supply and wiring Single control light point using rigid PVC ivory conduit 20 mm size conforming to IS and using 1.00 sq mm PVC insulated stranded single core FR copper conductor cable including providing switch board main ,and continuous earthing with 1.5sqmm green coloured FR wire ete according to IS 732-1989 and as per PWD specification (2012). with suitable size modular type metal switch boxes and front plates including 6 A modular type ROHS compliant SP switches 6A, 3 plate ceiling rose etc (Modular boxes ,switches and accessaries ,Make-Legrand Myrius/MK Blenz/Havells Oro/Hager/L&T)
Specification of work as above for ceiling fan point with socket size stepped electronic regulator .
Specification of work as above without ceiling rose for batten light point.
Specification of work as above for Combined plug point with 6 A, 5 pin plug socket controlled by 6 A switch in the same switch board as that of light points.
Supply, conveyance installation testing and commissioning of pre-wired light fittings16-20W LED tube fitting with poly carbonate / Aluminium heat strink THD <10%. directly on wall or ceiling with PVCround block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.
Supply, conveyance, installation, testing and commissioning of pre-wired light fitting made of CRCA sheet of .5mm thickness complete with all accessories and lamps etc. directly on wall using 2 nos. flat iron brackets made from 25x6mm flat iron, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.16-20W LED tube fitting with poly carbonate / Aluminium heat strink THD <10%
Supply and installation of LED tube light fittings (16-20W LED tube fitting with poly carbonate / Aluminium heat strink THD <10%) complete on ball and socket arrangements on PVC round block, suspension down rod of 19mm dia MS conduit up to 2x30cm using company made symetric mounting accessaries ( AC108P MB S) length including painting and wiring the down rod with 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS
Supplying and providing extra H.G conduit down rod of 19 mm dia 2 x 1.00 m long with 16/0.20 mm 3 core copper conductor flex wire conforming to relevant ISS or with the extended original wiring and giving connection etc. as required.
Supply and installation of LED Street light fittings LSTS-25-CDL Crompton make on 25 mm size GI Pipe 1 mtr long (minimum) bend/welded to shape and fixing to wall using sitable clamps and giving connection with with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS
Supply and installation of suitable size MS rod type fan clamp as per IS 732 as required.
Supply and installation of 1200mm sweap ceiling fan with standard accessories with out reglator including giving connection with 16/0.20 mm 3core round copper conductor flexible chord etc as required.(Crompton (High speed)/Havells(SS-390)
Charges for cutting holes suitable for accommodating exhaust fans of sizes up to 305 mm sweep including plastering, colour washing etc. as required.
Supply and installation of 150 mm medium duty 2300 rpm ,4 leaf exhaust fan in metal frame (Almonard/Crompton make) in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20 mm 3core round copper conductor flexible chord etc required.
Supply and fixing 20 mm dia light gauge PVC Conduit conforming to IS 9537 / 1983 part III along with all required accessories on surface including making good the damages etc as required.
Specification of work as detailed above with 25 mm dia PVC conduit on surface
Supply and drawing 1.50 sq mm 2 run 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections.
Specification of work as detailed above drawing1.50 sq mm 4 run copper cable
Specification of work as detailed above drawing1.50 sq mm 6 run copper cable
Specification of work as detailed above drawing 2.50 sq mm 2 run
Specification of work as detailed above drawing 2.50 sq mm 4 run
Specification of work as detailed above drawing 2.50 sq mm 6 run
Specification of work as detailed above drawing 4.00 sq mm 2 run
Specification of work as detailed above drawing 4.00 sq mm 4 run
Specification of work as detailed above drawing 6.00 sq mm 3 run
Specification of work as detailed above drawing 6.00 sq mm 4 run
Supply & Fixing 3 module metal/plastic box with white/ off-white front plate provided with 1 set of 6A SP switch and 6 A universel socket modular type in recess including making good the damages, colour washing etc as required (ROHS) including giving connections (Modular boxes ,switches and accessaries ,Make-Legrand Myrius/MK Blenz/Havells Oro/Hager/L&T)
Supply & Fixing 3 module plastic/metal box with white/ off-white front plate provided with 1 set of 16A SP switch and 6/16 A universel socket modular type in recess including making good the damages, colour washing etc as required (ROHS) including giving connections (Modular boxes ,switches and accessaries ,Make-Legrand Myrius/MK Blenz/Havells Oro/Hager/L&T)
Supply & Fixing 2module metal box with white/ off-white front plate provided with one 20A DP switch modular type in recess including making good the damages, colour washing etc as required (ROHS) including giving connections (Modular boxes ,switches and accessaries ,Make-Legrand Myrius/MK Blenz/Havells Oro/Hager/L&T) (For AC)
Supply & Fixing 2module metal box with white/ off-white front plate provided with one 20A socket modular type in recess including making good the damages, colour washing etc as required (ROHS) including giving connections (Modular boxes ,switches and accessaries ,Make-Legrand Myrius/MK Blenz/Havells Oro/Hager/L&T)
Supply & Fixing 8 module plastic box on surface/ recess with front plates provided with 2 nos of 6A SP switch and 3 nos 6 A universel socket modular type in recess including making good the damages, colour washing etc as required (ROHS) including giving connections(Modular boxes ,switches and accessaries ,Make-Legrand Myrius/MK Blenz/Havells Oro/Hager/L&T)
Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.(Legrand/OBO/MK)
Supply and fixing Cable divider on existing CMS
Supply and fixing External Angle 90°on existing CMS
Supply and fixing Internal Angle 90°on existing CMS
Supply and fixing Joint cover on existing CMS
Supply and fixing End Cap on existing CMS
Supplying & Drawing CAT 6 UTP Cable conforming to relevant standards through the existing conduit and giving connections as required(Legrand/AMP/V-guard)
Supply and fixing 2 module moulded plastic box/metal box on surface/recess, fixing moduler face plate with RJ 45 CAT 6 jack(Legrand/AMP/MK)
Supply and fixing of 19", 9U, 500 MM Depth Wall Mount Rack with Front Glass door, cooling fan 90cm ,NVRS, 1 No Power Distribution Unit Rack mounting type - 1 no, Cable Organizer /1U/Loop - 1No.(Netrack or equilent make)
Supply and installation of 28 Port ,rack mountable Giga bit Managed Ethernet switch(Model No. SG 350-28 CISCO make )
Supply and fixing of 24 port, Fully loaded patch panel Cold rolled steel, minimum 1.5 mm thickness, Individually removable CAT6 ports.
Supply and laying of 1.5 Sq.mm twin wire speaker cables in the existing conduit. (Approved makes: Belden/MX/Chetan).
Supplying & Drawing unarmored 4 Pair PVC insulated and & PVC sheathed copper conductor Telephone Pair Cable conforming to ITD specification for indoor application through the existing conduit
Supply and fixing 2 module moulded plastic box/metal box on surface/recess, fixing moduler face plate with RJ 11 Telephone jack with shutter(Legrand/AMP/MK)
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of 12 way single phase double cover (IP 42/43) MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required (Legrand/Hager/L&T/ABB/Indo-Asian optipro)(for 3 Nos UPS)
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof 6 way (8+18) (IP 42/43) double cover three phase MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required (Legrand/Hager/L&T/ABB/Indo-Asian optipro) ( For UPS DB)
Specification of workas detailed above with 6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
Supply and installation of with 63 A four pole mini break isolator suitable for 50 Hz , AC supply conforming to IS 8828-1995/ IEC 60898 in the existing enclosure and giving connections as required
Specification of work as detailed above with 40 A four pole mini break isolator
Specification of work as detailed above with 40 A double pole mini break isolator
Supply and installation of 40A,4 pole ,30mA RCCB suitable for 50 Hz , AC supply conforming to IS 8828-1995/ IEC 60898 in the existing enclosure and giving connections as required
Specification of work as detailed above with 63 A, 4 pole, 30 mA RCCB
Supply and installation of 6-32A 10KA, SP MCB( C curve) suitable for 50 Hz , AC supply conforming to IS 8828-1995/ IEC 60898 in the existing enclosure and giving connections as required
Specification of work as detailed above with40 A, 10 kA, TP MCB (C curve)
Supply and installation of 63 A, 415 V, 50 Hz, AC 23 A duty, 4 pole on-load change over switch in sheet steel enclosure complete with handle assembly, door interlock and pad locking arrangement on existing angle iron frame work or directly to wall using necessary bolts & nuts, fixing the unit to wall, making good the damages, colour washing etc. including giving necessary connections as required.
Supply, laying and clamping of 4 core 25 sq mm PVC insulated and PVC sheathed armoured aluminium power cable1.1 KV grade with factory made clamp , spacing of clamps not exceeding 60cms, making good the damages on wall , colour washing etc. as required.
Supplying and providing Brass cable gland for armoured aluminium conductor cable 1.1 KV grade, and making end termination,crimping aluminium tubular cable socket and providing earth clamps for cable gland as per KPWD standards suitable for 25 sq mm 4 core cable
Supply and providing plate earthing as per IS 3043 with 600x600x6.30 mm GI/CI earth plate, 20 mm GI watering pipe fixed to the earth plate with 20 x 3 mm GI clamps including inspection chamber complete with 300 x 300 x 6 mm cast iron gully trap with covering at the top of the inspection chamber of earth pit and providing as test joint 25 x 3 mm copper strip of minimum length 20 cm and providing earth lead from the test joint to the earth electrode using 4mm bare copper conductor including cutting, drilling necessary holes on the test joint (in Hard soil)as per KPWD standard
Supply and drawing bare earthing conductors 3.15 mm copper (10 SWG) along with wiring/ cables and giving connection as required.
Supply and laying bare earthing conductors 3.15 mm copper conductor (10 SWG) laid 0.6 m below ground level including excavating trench of suitable size and refilling etc. as required (in ordinary soil).
Supply and drawing bare earthing conductors 2.00 mm copper (14 SWG) along with wiring/ cables and giving connection as required.
Supply and drawing bare earthing conductors 2.65 mm copper (12 SWG) along with wiring/ cables and giving connection as required.
supply of superior quality copper earth socket for 3.15mm (10 SWG) of earth conductor including crimping etc. as required.
Specification as detailed above with 2.65 mm (12 SWG)socket
Specification as detailed above with 2.00 mm (14 SWG) socket
Supply and providing 25 x 3 mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
Supply and providing 25x6 mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
Supply and Installation of Outdoor type HENSEL make meter box (600X300x214 mm Mi 2410) suitable to fix 3 Phase Energy Meter with provision to fix in the box / base plate with 3 set of 63 A,415 V bakelite fuse fitting , fuse holder suitably rated HRC fuse and 63 A,2 way neutral link etc complete complete.
Supplly and providing iron hook grouted on wall /fixed suitably for service wire (Anchor bolt type)
Painting letters or figures of 2.50 cm, 4 cm or 5 cm height with enamel paint as identification mark to SB, DB, panel board etc as required
Supply and providing 5 Kg. Dry Chemical Powder type Fire Extinguisher with hose and clamps including fixing it to wall as required.
Supplying , threading , laying and jointing of 20 mm dia'B' class GI pipe with all required accessories in ground in the existing trench as protective covering to earth leads./Cables
Supply and providing 2 meter Cat 6 Patch Cord. Prefered make:Legrand/Amp
Testing of each and every node and making permenant labeling in the I/O box and on the patch panel.
Charges for preparing drawing of the complete Electrical installation after completion of the present work and preparing completion report with KSEB service connection application form and submitting to the consumer for availng 3 phase service connection/Load regularisation
HARISH AND CO
Bidder Name
Mighty
HARISH AND CO
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_519444.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .