| Sl No | Description | Qty | Unit | INTIMATE REFRIGERATION AND AIR CONDITIONS L1 | PIONEER COOLTECH L2 |
|---|---|---|---|---|---|
| 1.00Providing Air Conditioning | |||||
| 1.00 | OD154950/2025-2026:SITC of VRF Cassette type indoor units with wireless remote controller.The indoor units shall be of the four-way cassette type indoor units as per the requirements specified in the drawings. All indoors have electronic expansion valve that controls the flow of refrigerant in respond to the load variations of room according to set temperature, which can set by remote controllers. All indoor units should have inbuilt drain pump with minimum 700mm vertical lift head. Electricity characteristics for indoor unit shallbe 240volts/1phase/50hz.
4-way cassette type-4TR | 10 | each | 60,000 ₹6 L | 65,000 ₹6.5 L |
| 1.00 | OD149923/2025-2026:SITC of modular type VRF ODU.The outdoor unit shall be factory assembled, weather proof casing, constructed from heavy gauge mild steel panels and coated with baked enamel finish. The unit should be completely factory wired tested with all necessary controls. Out doors units of the vrf/vrv system shall be compact air cooled type. All the compressors of the outdoor units must be hermetically sealed bldc inverter scroll/twin rotary type. Oem should use there on make compressors in vrf /vrv system which is to be supplied. System cop shall not be less than 3.4 at AHRI condition and suitable to operate at heat load proportional to indoor temperature requirement. Aluminum fins of condenser coil shall have anti corrosive epoxy resin ocean black coating along with hydrophilic coating pre-coated at factory.
- 20HP | 1 | Sets | 5,58,000 ₹5.6 L | 5,88,000 ₹5.9 L |
| 1.00 | OD154952/2025-2026:SITC of modular type VRF ODU.The outdoor unit shall be factory assembled, weather proof casing, constructed from heavy gauge mild steel panels and coated with baked enamel finish. The unit should be completely factory wired tested with all necessary controls. Out doors units of the vrf/vrv system shall be compact air cooled type. All the compressors of the outdoor units must be hermetically sealed bldc inverter scroll/twin rotary type. Oem should use there on make compressors in vrf /vrv system which is to be supplied. System cop shall not be less than 3.4 at AHRI condition and suitable to operate at heat load proportional to indoor temperature requirement. Aluminum fins of condenser coil shall have anti corrosive epoxy resin ocean black coating along with hydrophilic coating pre-coated at factory. - 22HP | 1 | each | 6,18,880 ₹6.2 L | 6,22,880 ₹6.2 L |
| 1.00 | OD149933/2025-2026:Supply installation testing and commissioning of 'Y' joints - indoor | 9 | each | 3,360 ₹30,240 | 3,500 ₹31,500 |
| 1.00 | OD149934/2025-2026:Supply installation testing and commissioning of 'Y' joints - outdoor | 1 | each | 7,680 ₹7,680 | 8,000 ₹8,000 |
| 1.01 | OD149942/2025-2026:SITC of hard drawn copper refrigerant piping including all accessories including joints properly brazed insulated with chemically cross linked nitrile rubber fire retardant grade class o with 13mm thickness and necessary supports as required of size 41.3mm. | 60 | metre | 2,500 ₹1.5 L | 2,600 ₹1.6 L |
| 1.01 | OD149960/2025-2026:SITC of hard drawn copper refrigerant piping including all accessories including joints properly brazed insulated with chemically crosslinked nitrile rubber fire retardant grade class o with 13mm thickness and necessary supports as required 0f size 34.9mm | 20 | metre | 2,200 ₹44,000 | 2,300 ₹46,000 |
| 1.01 | OD149962/2025-2026:SITC of hard drawn copper refrigerant piping including all accessories including joints properly brazed insulated with chemically crosslinked nitrile rubber fire retardant grade class o with 13mm thickness and necessary supports as required of size 28.6mm | 25 | metre | 1,800 ₹45,000 | 1,900 ₹47,500 |
| 1.01 | OD149968/2025-2026:SITC of hard drawn copper refrigerant piping including all accessories including joints properly brazed insulated with chemically crosslinked nitrile rubber fire retardant grade class o with 13mm thickness and necessary supports as required of size 22.2mm. | 19 | metre | 1,550 ₹29,450 | 1,600 ₹30,400 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
7 Feb 2026, 6:00 pmClosed
Executive Engineer
PWD Electrical Division Thiruvananthapuram
DEPOSIT-Installation of AC at Ambedkar Hall, Public Service Commission Pattom-AC installation-Electrical AC Work
2026_PWD_832527_1
PWD/BLDG/EST/12351/2025
Open Tender
Electrical Works
180 days
pattom
Please refer Tender documents.
10 documents required · 10 mandatory
₹2,760
₹50,000
11 Mar 2026
31 Jan 2026
10 Feb 2026
31 Jan 2026
7 Feb 2026
31 Jan 2026
Providing Air Conditioning
OD154950/2025-2026:SITC of VRF Cassette type indoor units with wireless remote controller.The indoor units shall be of the four-way cassette type indoor units as per the requirements specified in the drawings. All indoors have electronic expansion valve that controls the flow of refrigerant in respond to the load variations of room according to set temperature, which can set by remote controllers. All indoor units should have inbuilt drain pump with minimum 700mm vertical lift head. Electricity characteristics for indoor unit shallbe 240volts/1phase/50hz. 4-way cassette type-4TR
OD149923/2025-2026:SITC of modular type VRF ODU.The outdoor unit shall be factory assembled, weather proof casing, constructed from heavy gauge mild steel panels and coated with baked enamel finish. The unit should be completely factory wired tested with all necessary controls. Out doors units of the vrf/vrv system shall be compact air cooled type. All the compressors of the outdoor units must be hermetically sealed bldc inverter scroll/twin rotary type. Oem should use there on make compressors in vrf /vrv system which is to be supplied. System cop shall not be less than 3.4 at AHRI condition and suitable to operate at heat load proportional to indoor temperature requirement. Aluminum fins of condenser coil shall have anti corrosive epoxy resin ocean black coating along with hydrophilic coating pre-coated at factory. - 20HP
OD154952/2025-2026:SITC of modular type VRF ODU.The outdoor unit shall be factory assembled, weather proof casing, constructed from heavy gauge mild steel panels and coated with baked enamel finish. The unit should be completely factory wired tested with all necessary controls. Out doors units of the vrf/vrv system shall be compact air cooled type. All the compressors of the outdoor units must be hermetically sealed bldc inverter scroll/twin rotary type. Oem should use there on make compressors in vrf /vrv system which is to be supplied. System cop shall not be less than 3.4 at AHRI condition and suitable to operate at heat load proportional to indoor temperature requirement. Aluminum fins of condenser coil shall have anti corrosive epoxy resin ocean black coating along with hydrophilic coating pre-coated at factory. - 22HP
OD149933/2025-2026:Supply installation testing and commissioning of 'Y' joints - indoor
OD149934/2025-2026:Supply installation testing and commissioning of 'Y' joints - outdoor
OD149942/2025-2026:SITC of hard drawn copper refrigerant piping including all accessories including joints properly brazed insulated with chemically cross linked nitrile rubber fire retardant grade class o with 13mm thickness and necessary supports as required of size 41.3mm.
OD149960/2025-2026:SITC of hard drawn copper refrigerant piping including all accessories including joints properly brazed insulated with chemically crosslinked nitrile rubber fire retardant grade class o with 13mm thickness and necessary supports as required 0f size 34.9mm
OD149962/2025-2026:SITC of hard drawn copper refrigerant piping including all accessories including joints properly brazed insulated with chemically crosslinked nitrile rubber fire retardant grade class o with 13mm thickness and necessary supports as required of size 28.6mm
OD149968/2025-2026:SITC of hard drawn copper refrigerant piping including all accessories including joints properly brazed insulated with chemically crosslinked nitrile rubber fire retardant grade class o with 13mm thickness and necessary supports as required of size 22.2mm.
OD149971/2025-2026:SITC of hard drawn copper refrigerant piping including all accessories including joints properly brazed insulated with chemically crosslinked nitrile rubber fire retardant grade class o with 13mm thickness and necessary supports as required of size 19.05mm
OD149995/2025-2026:SITC of hard drawn copper refrigerant piping including all accessories including joints properly brazed insulated with chemically crosslinked nitrile rubber fire retardant grade class o 19mm thickness necessary supports as required of size 15.9 mm dia
OD149996/2025-2026:SITC of hard drawn copper refrigerant piping including all accessories including joints properly brazed insulated with chemically crosslinked nitrile rubber fire retardant grade class o 19mm thickness necessary supports as required of size 12.7mmdia
OD149998/2025-2026:SITC of hard drawn copper refrigerant piping including all accessories including joints properly brazed insulated with chemically crosslinked nitrile rubber fire retardant grade class o 13mm thickness necessary supports as required of size 9.52mm dia
90.6.5.4:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.2 core 1.50 sq mm
90.6.5.21:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 6.00 sq mm
OD150007/2025-2026:Supply,installation,testing and commissioning of insulated condensate drain piping out of PVC-6kg/cm2 pipes complete with hangers/ supports/ clamps/clips and all fittings etc and insulated with 13 mm thoick nitrile rubber sleeves and joints sealed with 50 mm black PVC tapes-32 mm dia
OD287843/2025-2026:Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required. 300 mm width X 60 mm depth X 1.5 mm thickness
OD287946/2025-2026:Supplying and installing following size of perforated Hot Dipped Galvanized Iron cable tray "bends" (galvanization not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.300mm width X 60mm depth X 1.5mm thickness
OD150015/2025-2026:SITC of fresh air pvc pipe with all necessary fittings for indoor units. - uPVC pipe (working pressure 4 kg /cm2 ) 50 mm dia
OD150020/2025-2026:SITC of fresh air pvc pipe with all necessary fittings for indoor units. - uPVC pipe (working pressure 4 kg /cm2 ) 75 mm dia
OD150021/2025-2026:Charges for suppling and filling the R410A refregerent gas in the air conditioning system
OD287289/2025-2026:Supply and fabrication conveyance and installation of angle iron frame work for mounting VRF Outdoor units
OD154993/2025-2026:SITC of Air Curtain HV-3 type, air velocity 14m/s, 150W , single phase, 1400 RPM ,6 feet and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1399443.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.04 MB
viewsbd.pdf
Tender Documents • 1.63 MB
BOQ_1399443.xls
BOQ • 0.32 MB
MoM.pdf
Other Document • 0.51 MB
Download all tender documents and submit your bid