Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹76.4 LAccepted-AOC | ₹76.4 L | L1 | Accepted-AOC Tender in r/o M/s Laxmi Builders has been accepted being lowest and reasonable bidder |
| 2 | L2₹79.9 L+₹3.5 L (4.64%)Rejected-Finance 27 19 F F D BLOCK CHATTARPUR EXTN SOUTH WEST DELHI DELHI 110075 | SOUTH WEST DELHI | DELHI | 110075 | ₹79.9 L+₹3.5 L (4.64%) | L2 | Rejected-Finance Not lowest |
| 3 | L3₹83.5 L+₹7.1 L (9.29%)Rejected-Finance FLAT NO A 402 SHANKAR HEIGHTS NEAR CHETANA SCHOOL HAJI MALANG ROAD KALYAN EAST THANE MUMBAI 421 306 | THANE | MAHARASHTRA | 421306 | ₹83.5 L+₹7.1 L (9.29%) | L3 | Rejected-Finance Not lowest |
| 4 | L4₹87.2 L+₹10.8 L (14.2%)Rejected-Finance SHOP NO 5 OPP SHANI MANDIR PROFESSOR COLONY DISTT YAMUNA NAGAR HARYANA 135001 | YAMUNANAGAR | HARYANA | 135001 | ₹87.2 L+₹10.8 L (14.2%) | L4 | Rejected-Finance Not lowest |
| 5 | Rejected-Technical H NO 266 V P O PILKHANI DISTT AMBALA 133104 | AMBALA | HARYANA | 133104 | - | - | Rejected-Technical Two Class below firm |
Tender Value
₹81 L
EMD Value
₹1.5 L
Closing Date
17 Dec 2023, 6:00 pmClosed
CWE (AF) AMBALA
HQ CWE (AF) Ambala Ambala cantt 133001
DEMOLITION OF OLD OVER HEAD WATER TANK AND RECONSTRUCTION OF NEW OVER HEAD WATER TANK NEAR SRE ALONGWITH ALLIED WORK SERVICES AT AFS AMBALA UNDER GE(AF) AMBALA
2023_MES_627863_1
CWE/AF AMB/AMB-52/2023-24
Open Tender
Civil Works - Water Works
Item Rate
270 days
AMBALA CANTT
For MES enlisted contractor Class C Category a i and for un-enlisted contractor refer NIT
7 documents required · 7 mandatory
₹1,000
GE (AF) AMBALA
₹1.5 L
Yes
1 Feb 2024
10 Nov 2023
19 Dec 2023
10 Nov 2023
17 Dec 2023
10 Dec 2023
10 Nov 2023 - 23 Nov 2023
Amount
Excavation in over areas, not exceeding 1.5mtr deep and getting out, in soft/loose soil complete all as specified & directed.
Excavation over areas exc. 1.50 mtr but not exc. 3.00 mtr deep and getting out in soft/ loose soil exc etc complete all as specified & directed.
Supply and laying PCC M-15 1:2:4 using 40mm graded crushed stone aggregate as in foundation filling and mass concrete etc complete all as specified & directed.
All as per item No 3 here-in-above but at a height exc 7.5m but not exc 30m in any location and any position, complete all as specified & as directed.
Supply and laying Reinforced Cement concrete M-30 (design Mix) using 20 mm graded crushed stone aggregate as in foundation including raft, foundation beam plinth beam and mass concreting etc omplete all as specified & directed.
Supply and laying Reinforced Cement concrete M-30 (design Mix) using 20 mm graded crushed stone aggregate as in beam, cantilever,lintels over 1.5 M span etc complete all as specified & as directed.
All as per item No 6 here-in-above but at a height exc.7.5m but not exc 15m, complete all as specified & directed.
All as per item No 6 here-in-above but Height exc 15m but not exc 18m from FFL complete all as specified & directed.
All as per item No 6 here-in-above but Height exc. 18m but not exc. 24m, complete all as specified & as directed.
All as per item No 6 here-in-above but Height exc. 24m but not exc. 27m, complete all as specified & as directed.
Supply and laying Reinforced Cement concrete M-30 (design Mix) using 20 mm graded crushed stone aggregate as in slabs supported on walls, beam and columns in floors roofs, landings, balconies,canopies deck slabs and in shelves and like at height exc. 21m but not exc. 24 m from Ground level, complete all as specified & as directed.
All as per item No 11 here-in-above but at a height exc 24m but not exc 27m from Ground level, complete all as specified & as directed.
All as per item No 11 here-in-above but at a height exc. 27m but not exc 30m from ground levev complete all as specified & as directed.
Supply and laying Reinforced Cement concrete M-30 (design Mix) using 20 mm graded crushed stone aggregate as in Domes, vaults, shell roofs,arch ribs and folded platesand the like. at height exc.21m but not exc. 24m from ground level , complete all as specified and as directed.
All as per item No 14 here-in-above but at height ecx. 24m but not exc. 27m complete all as specified & as directed.
Supply and laying Reinforced Cement concrete M-30 (design Mix) using 20 mm graded crushed stone aggregate as in columns, pillers, piers posts and strut etc. complete all as specified and as directed.
All as per item No 16 here-in-above but at a height exc.7.5m but not exc 15m, complete all as specified & directed.
All as per item No 16 here-in-above but at a height exc.15m but not exc 18m, complete all as specified & directed.
All as per item No 16 here-in-above but at a height exc.18m but not exc 21m, complete all as specified & directed.
All as per item No 16 here-in-above but at a height exc.21m but not exc 24m, complete all as specified & directed.
All as per item No 16 here-in-above but at a height exc.24m but not exc 27m, complete all as specified & directed.
All as per item No 16 here-in-above but at a height exc. 27m but not exc 30m, complete all as specified & directed.
Supply and laying Reinforced Cement concrete M-30 (design Mix) using 20 mm graded crushed stone agg as in walls,retaining walls,basement walls,ballast walls and the likes any thickness above top of footing including attached pilaster and buttresses at a height exc 21m but not exc. 24m, complete all as specified & directed.
All as per item No 23 here-in-above but at a height exc 24m but not exc. 27m, complete all as specified & directed. Notes for BOQ item No. 5 to 24: (i) Contractor shall use only Ordinary Portland Cement(OPC) of grade 43/53 for RCC work. (ii) The cost of Admixture as per design mix deemed to be included in quoted rates.
M&L form work to sides of concrete foundations, footing, bases of columns, raft and raft beam, sides and soffits of foundation and plinth beam and similar work for rough finished curved surface etc complete all as specified & directed.
M&L for form work to sides of concrete foundations, footing, bases of columns, raft and raft beam, sides and soffits of foundation and plinth beam and similar work for rough finished flat surface etc complete all as specified & directed.
M&L form work to sides of pillers, posts, piers, columns square, rectangular or polygonal for rough finished surface of concrete circular on plan etc complete all as specified & directed.
All as per item No 27 here-in-above but at a height exc. 7.5m but not exc. 15m, complete all as specified & as directed.
All as per item No 27 here-in-above but at a height exc. 15m but not exc. 18m, complete all as specified & as directed.
All as per item No 27 here-in-above but at a height exc. 18m but not exc. 21m, complete all as specified & as directed.
All as per item No 27 here-in-above but at a height exc. 21m but not exc. 24m, complete all as specified & as directed.
All as per item No 27 here-in-above but at a height exc. 24m but not exc. 27m, complete all as specified & as directed.
Supply and laying Reinforced Cement concrete M-30 (design Mix) using 20 mm graded crushed stone aggregate as in spiral staircase including landings etc complete all as specified & as directed.
All as per item No 33 here-in-above but at a height exc. 7.5m but not exc. 15m, complete all as specified & as directed.
All as per item No 33 here-in-above but at a height exc. 15m but not exc. 18m, complete all as specified & as directed.
All as per item No 33 here-in-above but at a height exc. 18m but not exc. 21m, complete all as specified & as directed.
All as per item No 33 here-in-above but at a height exc. 21m but not exc. 24m, complete all as specified & as directed.
All as per item No 33 here-in-above but at a height exc. 24m but not exc. 27m, complete all as specified & as directed. Notes for BOQ item No.33 to 38: (i) Contractor shall use only Ordinary Portland Cement(OPC) of grade 43/53 for RCC work. (ii) The cost of Admixture as per design mix deemed to be included in quoted rates.
M&L formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, also splays between floors and beams, etc on curved surface or spiral etc complete all as specified & directed.
All as per item No 39 here-in-above but at height exc. 7.5m but not exc.15m, complete all as specified & as directed.
All as per item No 39 here-in-above but at height exc 15m but not exc 18m, complete all as specified & directed.
All as per item No 39 here-in-above but at height exc 18m but not exc 24m, complete all as specified & directed.
All as per item No 39 here-in-above but at height exc 24m but not exc 27m, complete all as specified & directed.
M&L formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exc exceeding 200mm thick, flat or curved, (horizontal or sloping) at height exc 21m but not exc 24m from ground level, complete all as specified and directed.
All as per item No 44 here-in-above but at height exc.24m but not exc. 27m, complete all as specified & directed.
M&L formwork to edges of soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, flat or curved, not exc exceeding 200mm wide (horizontal or sloping)complete all as specified and directed at height exc. 21m but not exc. 24m, complete all as specified & directed.
M&L formwork to spiral staircase with sloping or stepped soffits,including risers and stringers, flat or curved, (excluding landing)complete all as specified & directed.
All as per item No 47 here-in-above but height exc. 7.5m but not exc. 15m from Ground level, complete all as specified & directed.
All as per item No 47 here-in-above but height exc. 15m but not exc. 18m from Ground level, complete all as specified & directed.
All as per item No 47 here-in-above but height exc. 18m but not exc. 21m from Ground level, complete all as specified & directed.
All as per item No 47 here-in-above but height exc. 21m but not exc. 24m from Ground level, complete all as specified & directed.
All as per item No 47 here-in-above but height exc. 24m but not exc. 27m from Ground level, complete all as specified & directed.
M&L Formwork to sides and soffits of domes, vaults, shell roof slab, arch ribs, curved in two planes, complete at height exc. 21m but not exc. 24m complete all as specified & directed.
All as per item No 53 here-in-above but height exc. 24m but not exc. 27m, complete all as specified & directed.
M&L for Formwork to faces of walls,retaining walls,abutments,parapets and staircase railings and similar work including attached pillasters,buttresses,etc;vertical or to batter at height exc. 21m but not exc. 24m, complete all as specified & directed.
All as per item No 55 here-in-above but height exc. 24m but not exc. 27m, complete all as specified & directed.
M&L TMT bars 10 mm dia and over cut to length bent to shape required including cranking bending spirally for hooping and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. complete all as specified & directed.
All as per item No 57 here-in-above but height exc.7.5m but not exc. 15m from Ground level, complete all as specified & as directed.
All as per item No 57 here-in-above but height exc. 15m but not exc. 18m from Ground level, complete all as specified & as directed.
All as per item No 57 here-in-above but height exc.18m but not exc. 21m from Ground level, complete all as specified & as directed.
All as per item No 57 here-in-above but height exc.21m but not exc. 24m from Ground level, complete all as specified & as directed.
All as per item No 57 here-in-above but height exc.24m but not exc. 27m from Ground level, complete all as specified & as directed.
All as per item No 57 here-in-above but height exc.27m but not exc. 30m from Ground level, complete all as specified & as directed.
M&L for TMT bars 5 mm dia upto and including 10 mm dia as in stirrups spacers and binders cut to length bent to shape required including cranking bending spirally for hooping and binding with and including mild steel wire (annealed) not less than 0.9 mm dia.complete all as specified & directed.
All as per item No 64 here-in-above but height exc.7.5m but not exc. 15m from ground level, complete all as specified & as directed.
All as per item No 64 here-in-above height exc. 15m but not exc. 18m from ground level, complete all as specified & as directed.
All as per item No 64 here-in-above height exc.18m but not exc. 21m from ground level, complete all as specified & as directed.
All as per item No 64 here-in-above height exc. 21m but not exc. 24m from ground level, complete all as specified & as directed.
All as per item No 64 here-in-above height exc. 24m but not exc. 27m from ground level, complete all as specified & as directed.
All as per item No 64 here-in-above height exc. 27m but not exc. 30m from ground level, complete all as specified & as directed. Note for BOQ item No. 57 to 70: Contractor shall use only "Corrosion Resistant" TMT bars and the quoted rates are deemed to be included for this aspect.
S&F Stainless steel wire cloth,0.36 mm nominal diameter of wire and average width of aperture 1.4mm and fixed with stainless steel wire staples at height exc. 27 but not exc. 30m from Ground level, complete all as specified & as directed.
M&L for 5 mm thick rendering on fair faces of concrete surface finished even and smooth without using extra cement in CM 1:3 with water proofing compound (WPC will be measured and paid separately) complete all as specified & as directed.
All as per item No 72 here-in-above but at height exc.15m and not exc.30 m from ground level, complete all as specified & as directed.
M&L 5 mm thick rendering on ceiling of concrete surface finished even and smooth without using extra cement in CM 1:3 with water proofing compound (WPC will be measured and paid separately) complete all as specified & as directed.
Supply only integral water proofing liquid compound complete all as specified & directed.
M & L preparation of new plastered surface of walls and Applying two coats of cement base paint over a coat of primer preparatory plastered untreated surface complete all as specified and directed at height up to 15m from ground level, complete all as specified & as directed.
All as per item No 76 here-in-above but height exc. 15m and not exc 30m from ground level, complete all as specified & as directed.
S&F Hand rails,half round or other steel sction or core for wooden hand-rail straight portion,drilled and countersunk for balusters running bars,for doors,balusters,nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts and similar works conforming to Fe-290 Gde E-165 up to 15m height from groundlevel, complete all as specified & directed.
All as per item No 78 here-in-above but height exc.15m and not exc. 30m from ground level, complete all as specified & directed.
M&L for preparation of new steel and iron surfaces of any description over 10 cm in width or girth, priming with a coat of red oxide primer and applying two coats of synthetic enamel paint up to 15m height from ground level, complete all as specified & directed.
All as per item No 80 here-in-above but height exc. 15m and not exc. 30m from ground level, complete all as specified & as directed.
S&F framed bracket of angles or tees with web and flange cut to shape,drilled and countersunk for screw including bending and welding angles as necessary gusset plate riveting etc n.exc 10kg bracket conforming to Fe 290 Gde-E-165 at height exc. 15m and not exc. 30m from ground level, complete all as specified & as directed.
S&F Mild steel,plain black sheet in wall cladding,steel gates and similar work ,cut to size,holes punched,including round headed screws,clout nails or rivets and fixed to wood or steel framing with plain 40mm lap joint with riveted or welded seams,including bending or turning up,mitred angles etc as required complete all as specified & directed.
M&L for Plain Cement Concrete 1:3:6,type C-2, using 40mm graded crushed stone aggregate, complete all as specified & as directed.
Supply & laying Cement Concrete in surface channels and drains,type B2,1:2:4 (40mm graded aggregate) complete all as specified & directed.
M&L Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms,moulds,mitred/stopped ends etc. complete all as specified and directed.
M&L Returning filling in, including spreading levelling watering and well ramming in layers n. exe 25 cm etc complete all as specified and as directed.
M&L Removing excavated material exc.250m but not exc.500m and depositing where complete all as specified and directed.
M & L preparation of new plastered surface of walls and applying two coats of food grade paint over a coat of primer preparatory plastered untreated surface complete all as specified and directed at height exc 21m but not exc 27m from ground level complete all as specified and as directed.
S&F 200mm wide ISI marked water bar of HDPE or TVP or rubber in RCC joints and fixed in position before casting of RCC, complete all as specified and as directed.
Surface excavation not. exc 30 cm deep and averaging 15 cm depth and getting out in soft loose soil , complete all as specified & as directed.
M&L Hardcore of gauge n exc 63mm, deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface etc complete all as specified & as directed.
Removing Excavated material(soil) exc . 250 m but not exc. 500 m and deposited where directed at a level n. exc 1.5 m above the starting point complete all as specified & as directed.
M&L 100 mm thick Plain Cement Concrete type D2 1:4:8 using 40 mm graded aggregate as in sub-base etc complete all as specified and directed etc complete all as specified & directed.
M&L providing cement concret in edge type B1 1:2:4 using 20 mm graded aggregate in roof kerbs or mud stops rounded or chamfered on edges etc complete all as specified & directed.
M& L 25 mm thick sand filling / cushioning for bed of interlocking tiles watering and consolidation etc complete all as specified & directed
Excavation in trenches not exceeding 1.5mtr wide and not exceeding 1.5mtr in deep for laying of water pipe lines/taking out pipe lines and getting out in soft/loose soil including forming bottom surface to required level and slope etc complete all as specified & directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 2.5 cm in soft/loose soil complete all as specified & directed
Removal of surplus soil to a distance not exc 500 mtrs & depositing where directed at a level not exc 1.5 mtrs above the starting point etc complete all as specified & directed.
Supplying and laying/fixing in trenches/vertically on walls or pillars of OHT centrifugally cast (spun) ductile iron pipes of 150mm dia pressure pipes with flanged end, class 'K-9' conforming to IS:8329/2000 (latest version) suitable for rubber gasket jointing with inside cement mortar lining with portland slag cement as per IS 455:1989 and external metalic zinc coating as per annex A of IS 8329 with finishing layer of bitumin coating as per annex C duly ISI marked in any length including rubber gasket and its testing and commissioning etc complete all as specified & directed. Note: Cost of clamps for fixing the vertical pipeline as shown in drawing are deemed to be included in quoted rates.
Supplying and laying/fixing in trenches/vertically on walls centrifugally cast (spun) ductile iron pipes of 150mm dia pressure pipes with spigot & socket, class 'K-9' conforming to IS:8329/2000 (latest version) suitable for rubber gasket jointing with inside cment mortar lining with portland slag cement as per IS 455:1989 and external metalic zinc coating as per annex A of IS 8329 with finishing layer of bitumin coating as per annex C duly ISI marked in any length including tyton joints and its testing and commissioning etc complete all as specified & directed.
Supplying and laying/fixing in trenches centrifugally cast (spun) ductile iron pipes of 100mm dia pressure pipes water delivery with socket and spigot, end class 'K-9' conforming to IS:8329/2000 (latest version) suitable for rubber gasket jointing with inside cment mortar lining with portland slag cement as per IS 455:1989 and external metalic zinc coating as per annex A of IS 8329 with finishing layer of bitumin coating as per annex C duly ISI marked in any length including tyton joints and commissioning etc complete all as specified & directed.
Supply, fixing, testing & commissioning of Double flanged non-rising stem type cast iron sluice valve suitable for 150 mm dia/bore pipe with hand wheel and suitable for pressure rating of PN 1.6 duly drilled holes for fixing of nuts and bolts, stem made of high tensile brass ISI marked and conforming to IS 14846 - 2000 including rubber gasket, nuts, bolts and washers complete all as specified & directed.
Supply, fixing, testing & commissioning of Double flanged non-rising stem type cast iron sluice valve suitable for 100 mm dia/bore pipe with hand wheel and suitable for pressure rating of PN 1.6 duly drilled holes for fixing of nuts and bolts, stem made of high tensile brass ISI marked and conforming to IS 14846 - 2000 including rubber gasket, nuts, bolts and washers complete all as specified & directed.
Supply, laying and jointing heavy duty class K-12, DI fittings i.e bends (any type, radius and angle), tapers and type, (Straight, bend, increasing,decreasing or double socket etc), Tee pieces single branch, Y junction, Double branch, Cross (all sockets or socket and spigot or all flanged or one end flanged and other ends spigot/ socketed), collars, caps,bell mouth and plugs/header complete and conforming to IS:9523/2000 etc complete all as specified & directed.
Supply, fixing, testing & commissioning of Double flanged, cast Iron, swing check type reflux (Non Return) valve suitable for 150 mm dia/bore pipe, single door pattern conforming to IS : 5312 ( part -I ) 1969, duly drilled holes for fixing nuts and bolts including rubber gasket, nuts, bolts and washers etc. complete all as specified & directed.
M&L cutting existing cast iron/DI pipes 150mm and reducing to required length in position for insertion of new tees, branches, new connections etc before laying etc complete all as specified & directed.
M&L cutting existing cast iron/DI pipes 100mm and reducing to required length in position for insertion of new tees, branches, new connections etc before laying etc complete all as specified & directed. Note for BOQ item No. 107 & 108: Excavation & Earth work shall be measured & paid separately.
M&L masonry valve pit of size 1050mmx1050mmx900mm internal size complete with excavation, earth work and brick work in CM 1:6, 15mm thick plastering in CM 1:4 internally including 5mm thick MS Sheet cover and angle iron frame of suitable size and two coats of synthetic enamel paint over one coat of red oxide primer etc complete all as specified & directed.
M&L fabrication of water level indicator with frame made out of MS Sheet 2mm thick of size 1'x12' and hollow MS bar/angle iron 50x50x6mm including all fixing arrangement like wire, rope of size 6mm dia of best quality (upto 25mtr length) and 350mm steel float valve incl painting two coats of synthetic enamelled paint over a coat of red oxide primer incl level marking and fixing etc complete all as specified & directed.
M&L boring/auguring suitable hole of 250/200mm dia and inserting pipe upto 150mm/100mm dia and 600mm below existing PCC/road/hard standing complete all as specified & directed. Note :- Cost of equipment, tools and plants and material required for boring shall be deemed to be included in the quoted rate except pipeline inserted etc complete all as specified & directed.
M&L PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in pedestal/ foundation/base for header and in embedding blocks etc including form work etc complete all as specified & directed.
Excavation in trenches exceeding 1.5mtr wide and not exceeding 1.5mtr in deep for laying of water pipe lines/taking out pipe lines and getting out in soft/loose soil including forming bottom surface to required level and slope etc complete all as specified & directed.
M&L dry clean river sand for cushioning of cable in trenches for cables in trenches for cables in trenches for cable protection including spreading, levelling and hand punning etc complete all as specified & directed.
M&L common burnt clay, sub class 'B' bricks, designation 75, laid flat for protection of cable , adjacent to each other, perpendicular to central axis of cable etc complete all as specified & directed.
M&L PCC 1:4:8, type D2, using 40mm graded stone aggregate as in pedestal /foundation/base of pole and in embedding blockes etc including form work etc complete all as specified & directed.
M&L PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in padestal/ Foundation/base of pole and in embedding blocks etc including form work etc complete all as specified & directed.
S&F LED aviation light with integral driver comprising of die cast aluminium housing with red polycarbonated dome for better illumination, IP 65,230VAC, connection and testing etc complete all as specified & directed.
S&F 3 core PVC insulated flexible copper cable 1.5 Sqmm/core weather proof in size black/grey colour duly clamped to wall etc complete all as specified & directed.
S&F air termination single pointed aluminium rod 12 mm dia, 300mm long duly fixed/secured with PCC or with GI pipe supports complete all as specified & directed.
M&L test point terminal block made of gun metal or phosphorus bronze size 75mm x 75mm x 25mm drilled and screwed with and including 3 nos, 8mm dia, 25mm long hexagonal head screw complete all as specified & directed.
S&F aluminium strip 25x3mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc complete all as specified & directed.
M&L Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) etc complete all as specified & directed.
S&F LED street light fitting 90 watt 230V AC, 110 lumen/watt, PF greater than 0.90 outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP65/66 portection etc complete all as specified & directed.
S&F pole mounted cable junction box weather proof of size 295mmx225mmx122mm outdoor type, with three phase and neutral, aluminium bus bar 25mmx4mm size and 01 No MCB 6A SP 10KA including fixing with 02 Nos flat iron clamps of suitable size with necessary mild steel nuts & bolts etc complete all as specified & directed.
Supplying, laying, jointing, testing XLPE insulated, extruded PVC outer sheath and inner sheath, galvanised steel armoured cable with aluminium cable with aluminium conductor suitable for rated voltage of 1100 volts grade and laid in trenches/pipe /ducts or on pole, 16 Sqmm 4 core etc, complete all as specified & directed.
M&L earthing complete with galvanized steel earth plate 60 cm X 60 cm X 6 mm thick buried vertically in ground to depth not less than 2.25 metres below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to GI earth lead strip 32x6 mm upto 7.5 mtrs long by means of bolts, nuts, check nuts and washers of galvanized iron and connection to earthing test point & earth dolly including watering pipe GI 20 mm bore, light grade including protection pipe GI light grade 40mm bore , wire mesh, funnel,lugs, salt, charcoal dust, excavation and refilling pit chamber with PCC 1:2:4 type B1 using 20 mm graded mechnically crushed stone aggregates , RCC 1:2:4 type B-1 using 20 mm graded mechnically crushed stone aggregates pit cover slab 50 mm thick reinforced with 8 mm dia TMT bars @ 15 cm c/c both ways including necessary form work all as shown in electrical plate No 3 of SSR part-I (2009), including testing on completion including taking down of existing earthing as exists on site complete all as specified & directed.
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion etc complete all as specified & directed.
M&L GI earthing strip 32x6mm fixed to wll/laid in trenches for interconnection/ extension in earthing incl excavation and earth work complete all as specified & directed.
S&F single phase timer switch with nature switch-02EC sensor with pre drawn switching off timer, MCB power contactor, thermoplastic polycarbonate enclosure of maxium load capacity 05 KWs, 230 volts, 50 Hz degree of protection conforms to IP-66 etc complete all as specified & directed.
Supply, installation testing & commissioning of Ultrasonic level transmitter for continuous level monitoring suitable for clear water applications continuous level measurement from 0 to 100% of the range 230 VAC,50Hz or 9-30 VDC as available at site output 4-20ma, range-0-8m with display panel alongwith its enclosure installed at pump house etc complete all as specified & directed.
S&F control cable, 1.5 sqmm x4 core copper working voltage upto 1100 volt gas per IS 694 etc complete all as specified & directed.
Supply, laying, testing GI tubing 40mm dia bore light grade conforming to IS : 1239 with all fittings laid in trenches etc complete all as specified & directed.
Supplying and installing 100mm width x50mm depthx1.6mm thickness size of perforeated painted with powder coating MS cable trays with perforation not more than 17.5% in convenient sections, joined with connectors, suspended from the ceiling with MS suspenders including bolts & nuts painting suspenders etc complete all as specified & directed.
Taking up or down CI water mains 150mm dia bore (including all fitting) with S/S or flanged ends and lead joints including burning out joints and recovering lead etc complete all as specified & directed.
Taking up or down Sluice valve /NRV of any type/size etc complete all as specified & directed.
Taking down aviation light of any type/size etc complete all as specified & directed.
Taking down Air terminatin pointed rod of any type/size complete all as specified & directed.
Taking down test terminal of any type/size complete all as specified & directed.
Taking down aluminium strip 20x3mmx25x3mm etc complete all as specified & directed.
Taking down aluminium cable 6 Sqmm 2 core of any type etc complete all as specified & directed.
Taking down frame of water level indiactor of any type etc complete all as specified & directed.
Demolition of over head water tank, reinforced cement concrete(RCC) of any description and in any position not otherwise specifically provided including cutting the reinforcement as required to facilitate demolition and removal of debris to a distance exceeding 5Km complete all as specified & directed.
M&L 60 mm thickness M-40 grade machine pressed precast concrete interlocking paver block, any shape and size conforming to IS 15658-2006, with grey cement and pigment complete all as specified & directed.
For Credit Schedule refer tender documents. The amount of credit schedule shall be deducted in total quoted amount of BOQ to arrive contract sum.
KULWANT SINGH
Gupta Enterprises
JS CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .