Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.7 LAccepted-AOC E I HOUSE ERTHUMKADAVU MUTATHODY POST KASARAGOD 671121 | KASARAGOD | KASARAGOD | KERALA | 671121 | L1 | Accepted-AOC L1 | |
| 2 | L2₹4.9 L+₹13,674.28 (2.86%)Rejected-Finance | L2 | Rejected-Finance L2 |
Tender Value
₹4.4 L
EMD Value
₹10,884
Closing Date
3 Mar 2020, 5:00 pmClosed
ASST EXECUTIVE ENGINEER
O/O ASST EXECUTIVE ENGINEER,PWD BUILDINGS SUBDIVISON KASARAGOD
CIVIL STATION KASARAGOD FLUSHING EXISTING BOREWELL AND PROVIDING WATER SUPPLY LINE TO A AND B BLOCK
2020_PWD_345780_1
D2/22/e-tender/2019-20
Open Tender
Civil Works - Buildings
Item Rate
150 days
VIDYANAGAR
Please refer Tender documents.
4 documents required · 4 mandatory
₹960
online
₹10,884
Yes
3 Apr 2024
24 Feb 2020
5 Mar 2020
24 Feb 2020
3 Mar 2020
24 Feb 2020
Amount
APPENDIX - A -
23.13.3 : Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:200 mm dia
23.14.3 : Providing and fixing M.S. clamp of required dia to the top of casing / housing pipe of tubewell as per IS : 2800 ( part I), including ecessary bolts & nuts of required size complete.200 mm clamp
23.3.3 : Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS : 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer- in- Charge.200 mm nominal size dia
od54675/2019_2020 : Flushing and Cleaning the Bore well of required dia for casing / strainer pipe, by suitable method prescribed in IS: 2800 ( part I), including collecting samples from different strata, preparing and submitting strata chart/ bore, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer- in- charge, beyond 90 metre & upto 150 metre depth below ground level.<br>All types of soil<br>200 mm dia
od54676/2019_2020 : Flushing and Cleaning the bore well of required dia for casing / strainer pipe, by suitable method prescribed in IS: 2800 ( part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools plants & machineries required for the job, all complete as per direction of Engineer - in- Charge, upto 90 metre depth below ground level.<br>All types of soil<br>200 mm dia
od54677/2019_2020 : Engaging coolie for Lifting and Erecting Bore Well Pump Set
5.1.3 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
50.18.9.7.1 : Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement, trenching refilling & testing of joints complete as per direction of Engineer in Charge. 63 mm dia 6Kgf/cm2
od58112/2019_2020 : Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 200 mm dia Socket/ coupling
50.18.9.6.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm dia 10Kgf/cm2
50.18.9.17.1 : Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 6 Kgf/cm2 - External work - Exposed on wall
50.18.7.5.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 40 mm dia 10 Kgf/cm2- Internal work- exposed on wall
50.18.7.4.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10Kgf/cm2- Internal work - Exposed on wall
2.28.1 : Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.All kinds of soil
2.31 : Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area clearedClearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
2.32 : Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
od58118/2019_2020 : Removing septic tank covering slab carefully and dispositing the black soil from the tank to the excavated pit of size 5.40 x 1.90 x 2.50 M and refilling the pitwith excavated refixing the covering slab etc….. Complete.
ABDUL MUNAVAR E M
Bidder Name
E I MUHAMMED
ABDUL MUNAVAR E M
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_484253.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .