Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.9 LAccepted-AOC TUPKHANA PART 1 PO ARUNACHAL PS SILCHAR DIST CACHAR ASSAM 788025 | CACHAR | ASSAM | 788025 | L1 | Accepted-AOC Being L1 bid | |
| 2 | L2₹26.7 L+₹1.0 L (4.07%)Rejected-AOC | L2 | Rejected-AOC Being higher than L1 bid | |
| 3 | L3₹27.0 L+₹1.3 L (5.05%)Rejected-AOC | L3 | Rejected-AOC Being higher than L1 bid | |
| 4 | L4₹27.1 L+₹1.4 L (5.53%)Rejected-AOC | L4 | Rejected-AOC Being higher than L1 bid | |
| 5 | L5₹27.1 L+₹1.4 L (5.63%)Rejected-AOC | L5 | Rejected-AOC Being higher than L1 bid |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
25 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SILCHAR
GE SILCHAR, PO-ARUNACHAL, DIST-CACHAR, ASSAM-788025
REPAIR REPLACEMENT OF SERVICE CONNECTIONS INCL DISTRIBUTION BOARDS OF VARIOUS ACCN AND REPAIR TO FAN GEYSERS AT MASIMPUR MIL STN UNDER GE SILCHAR
2022_MES_499693_1
8682/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
MASIMPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE SILCHAR
₹50,000
Yes
4 Feb 2022
5 Jan 2022
27 Jan 2022
5 Jan 2022
25 Jan 2022
20 Jan 2022
60 days
Amount
Excavating in trenches, not exc 1.5 m wide and not exc 1.5 m in depth for foundation etc. and getting out in soft / loose soil complete all as specified and directed.
Excavating in trenches, not exc 1.5 m wide and not exc 1.5 m in depth for foundation etc. and getting out in hard / dense soil complete all as specified and directed.
Returning, filling in with soil obtained from excavation including spreading levelling watering and well ramming in layers not exceeding 25 cm complete all as specified.
Removing excavated material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified.
Material and labour for laying of bricks locally available sub-class 'B' brick (old size) for cable protection cover laid flat and dry in trenches over the cable perpendicular to the directon of cable complete all as specified and directed.
Supply and spread sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. Note : Thickness of sand cushion after punning down will be measured and paid.
Supply and laying 50mm bore GI tubing light grade with all fittings for passing of cable under road, on wall or on pole with and including MS clams of suitable size and making good surfaces complete all as specified and as directed.
Supply and Laying or passing throught pipe XLPE sheathed, armored LT electric power Cable (heavy duty) with stranded aluminium conductor of size 50 Sqmm, 3.5 core 1100Volt grade laid throught duct /pipe / trench etc incl cable gland and lugs including taking out of existing unserviceable cable complete all as specified and directed.
All as per item No 8 but of of size 35 Sqmm, 3.5 core
All as per item No 8 but of of size 25 Sqmm, 3.5 core
All as per item No 8 but of of size 10 Sqmm, 4 core
Supply and fix 1100 Volts grade heavy duty cable PVC insulated aluminium multistranded conductor of size 16 sqmm, served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hanges not more than 1 meter apart including 4mm suspension wire, two twin core cable flat or circular including taking down old unserviceable wire all as specified and directed.
Supply and fix 1100 Volts grade heavy duty cable PVC insulated aluminium multistranded conductor of size 10 sqmm, served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hanges not more than 1 meter apart including 4mm suspension wire, one twin core cable flat or circular and including taking down old unserviceable wire all as specified and directed.
Supply and fix 1100 Volts grade heavy duty cable PVC insulated aluminium multistranded conductor of size 6 sqmm, served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hanges not more than 1 meter apart including 4mm suspension wire, one twin core cable flat or circular and including taking down old unserviceable wire all as specified and directed.
M&L for Boring hole under-neath road/hardstanding/pavement with trenchless technology using mechanical drilling/horizontal boring machine for crossing of cable without cutting the surface and providing 80mm bore HDPE pipe suitable for 0.4mpa working pressure and making good the disturbed area etc complete all as specified and directed. Note : 80mm bore HDPE pipe is deemed included in unit rate quoted by the contactor.
Supply and fix sheet metal enclosure powder coated single phase DB for fixing of MCBs, 8 ways double door with bus bar including grouting on the wall by means of screws and rawal plugs and making good disturbed surfaces including taking out of existing unserviceable DB complete all as specified and directed.
Supply and fix sheet metal enclosure powder coated single phase DB for fixing of MCBs, 4 ways double door with bus bar including grouting on the wall by means of screws and rawal plugs and making good disturbed surfaces including taking out of existing unserviceable DB complete all as specified and directed.
Supply and fix sheet metal enclosure powder coated three phase and Neutral DB for fixing of MCBs, 4 ways double door with bus bar including grouting on the wall by means of screws and rawal plugs and making good disturbed surfaces including taking out of existing unserviceable DB complete all as specified and directed.
Supply and fixing metal plug and socket with MCB SP 20 amp 240 V enclosure for AC/equipment with neutral and earth point taking out of existing unserviceable DB complete all as specified and directed.
Supply and fix sheet metal enclosure powder coated three phase and Neutral DB double door, 50 Hz including outgoing (6+6+6) modules with bus bar including grouting on the wall by means of screws and rawal plugs with & including MCCB incomer of capacity 160 amp, 4 pole -01 No & MCB 16-32 Amp SP 10 KA , 18 Nos , and making good distrubed surfaces including taking down old unserviceable complete all as specified and directed. Make L&T model No DBVTH006SD (DB) & , MCCB cat part No CM90634OOMO, MCB 16 -32 Amp cat part No BB10160B) or equivalent make as specified in PS
Supply and fix Enclosures for MCCBs common enclosure for 4 pole MCCBs inbuilt nutral link for TPN system including mounting holes of easy wall mounting, Louvers for better heat dissipation size of suitable for 4 pole 160A to 250A MCCBs, 50kA, including taking down old unserviceable Make L&T cat part o (DU250C/DU250/DNI) CM91003OOOO , MCCBs cat part No CM98065OONO) or equivalent make as specified in PS
Supply and fix MCB SP 240 volts, 50 Hz capacity 6-32 Amps, 'C' Curve, complete all as specified and directed
Supply and fix MCB SPN 240 volts, 50 Hz of capacity 40 Amps, 'C' Curve , complete all as specified and directed
Supply and fix MCB TPN 415 volts, 50 Hz of capacity 63 Amps, complete all as specified and directed
Material and labour for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth lead wire 4 mm dia by means of galvanized iron or steel bolts, nuts, check nuts and washers, and connected to equipments as directed, including funnel with GI medium grade watering pipe 20 mm bore &15 mm bore GI light grade protection pipe , wire mesh, charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with concrete pit in PCC 1:3:6 type C1, 50 mm thick pre cast RCC 1:2:4 type B1 cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar, GI medium grade pipe for earth lead protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance not exceeding 50 m and necessary testing complete all as shown on electrical plate No. 3 of MES Schedule 2009, Part-I complete all as specified and directed.
Material and labour for PCC 1:2:4 type B-1 using 20 mm graded stone aggregates as in 100 mm thick floor finished even & smooth without using extra cement complete all as specified and directed.
Supply and fix House service bracket (hook type complete with 3.0m long G.I. pipe 40mm bore Medium grade with , two nos 90 bends. M.S.hook and stay or guy fixed in repairs complete all as specified and directed.
Supply and fix LED driver for existing bollard light 10 watt with operating voltage 140-270VAC input voltage fixed in repairs, complete all as specified and dirtected. Make: crompton,Cat Part No. LBLTW-1--CDL, Driver Code no. 11L-012-0700-01-P8(140) or equivalent.
Taking down carefully 1200/1400mm sweep ceiling fan of any make from the hook and carry to the wksp including rehanging after repair the same at existing position after cleaning dirt, greasing of fan complete all as specified and directed NOTE :- Total service time from taking down to rehanging must not exceed 3 Days. ( repair Work shall be measured & paid for eperately under respective items
Painting of ceiling fans 1200/1400 mm sweep complete with white synthetic enamel paint by spray painting to achieve a smooth and uniform finish (one coat) after cleaning and filling up cavaties with filler and marking MES No with black paint of required size complete all as specified and directed Note :- Painting of fans must be done before delivery of fan by contractor to Deptt within stipulated time of 3 Days
Strip opening of ceiling fan 1200 sweep and carrying out rewinding with proper grade/guage super enamelled copper winding wire ( approximate weight of winding wire 275 -325 gms /fan ) so as to achieve original specifications i.e current rating and RPM including all insulating materials,bushes etc re-assembling including testing for continious 2 hrs complete all as specified and directed Note :-1. RPM test of ceiling fan with suitable tachometer will be done in the presence of Engineer -in -Charge. 2. All T & P will be provided by the contractor with in the rates quoted for the item.
All as per srl item No.31 above but ceiling fan of 1400mm sweep ( approximate weight of winding wire 300 -350 gms /fan ). Note :-1. RPM test of ceiling fan with suitable tachometer will be done in the presence of Engineer -in -Charge. 2. All T & P will be provided by the contractor with in the rates quoted for the item.
Supply & fixing ball bearings suitable for ceiling fans of size 6201 complete all as specified and directed by Engr-in-Charge complete. Make: SKF or technocommerically equivalent make of NBC/URB.
All as per srl item No 33 but of size 6202 complete Make: SKF or technocommerically equivalent make of NBC/URB.
All as per srl item No 33 but of size 6203 complete. Make: SKF or technocommerically equivalent make of NBC/URB.
All as per srl item No 33 but of size 6204 complete Make: SKF or technocommerically equivalent make of NBC/URB.
Taking out existing worn out /defective gun metal bush and material & labour for new gun-metal bush to the ceiling fans of any size/make incl reassembling and testing etc complete all as specified and directed
Taking out existing defective/worn out condenser any size/make and material and labour for condensor of capacity 2.5 mfd ,220 Volts including making connections etc complete all as specified and directed by Engr-in-Charge Make: USHA or technocommerically equivalent of make BAJAJ/HAVELLS.
All as per srl item No.38 above but of capacity 3.15 mfd capacity Make: USHA or technocommerically equivalent of make BAJAJ/HAVELLS.
All as per srl item No.38 above but size 4 mfd, Make: USHA or technocommerically equivalent of make BAJAJ/HAVELLS.
Taking out defective fan regulator any type and make and supply & fix electronic step type fan regulator 5 stage speed variation ISI marked including making connection etc and cutting to the required size of 3 mm thick bakelite sheet where required complete all as specified and directed Make :Havells or technocommerically equivalent of make Cona/ Plaza.
Taking out worn out/cracked canopy and supply & fixing canopy with screws to the ceiling fans of any size/make etc complete. (Set of 2 pieces)
Supply and fixing plastic bottom cover of ceiling fans any size complete with and including all fixing arrangements complete all as specified and directed.
Taking down carefully exhaust fan 225mm to 450mm sweep from the existing location any make including re-fixing the same after repair in existing position after cleaning and greasing complete all as directed by Engr-in-Charge. Note :- 1. Total service time from taking down to rehanging must not exceed 3 Days.
Painting to exhaust fans/bracket fans/wall mounting fans/pedestal fans up to 300 mm sweep of any make with one coat of synthetic enamel smoke grey paint by spray painting to achieve smooth and uniform finish incl removal of existing paint, filling up cavities with filler complete all as specified and directed by Engr-in-Charge . Note :- 1.Painting of fans must be done before delivery of fan by contractor to Deptt within stipulated time of 3 Days 2. All T & P will be provided by the contractor with in the rates quoted for the item.
All as per ser item No 45 above but of size 375 mm to 450 mm sweep.
Material and labour for re-winding of exhaust fan/bracket fans/wall mounting fans/pedestal fans 225mm to 300 mm sweep after strip opening of motor with proper grade/guage of super enamelled copper winding wire (approximate weight of winding wire 250 -300 gms /fan ) so as to achieve original specifications i.e current rating and RPM including all insulating materials, bushes etc re-assembling including testing for continious 2 hrs complete all as specified and directed Note :-1. RPM test of ceiling fan with suitable tachometer will be done in the presence of Engineer -in -Charge. 2. All T & P will be provided by the contractor with in the rates quoted for the item.
Material and labour for re-winding of exhaust fan/bracket fans/wall mounting fans/pedestal fans 375mm to 450mm sweep after strip opening of motor with proper grade/guage of super enamelled copper winding wire ( approximate weight of winding wire 275 -325 gms /fan ) so as to achieve original specifications i.e current rating and RPM including all insulating materials,bushes etc re-assembling including testing for continious 2 hrs complete all as specified and directed Note :-1. RPM test of ceiling fan with suitable tachometer will be done in the presence of Engineer -in -Charge. 2. All T & P will be provided by the contractor with in the rates quoted for the item.
Taking down worn out/defective metalic blades of exhaust fan/wall mounting/ padestal fan off size 225mm to 300mm sweep and supply and fixing new blades as per sample and make to the exhaust fan refixing in existing position etc complete all as specified and directed.
All as per srl No 49 but of size 375 mm to 450 mm sweep.
Supply and fix in repairs heating element 1.5 KW for as required at site including rubber washers (ISI marked), Triangular/round shape with pocket for thermostat complete all as directed
Supply and fix in repairs heating element 2 KW for as required at site including rubber washers (ISI marked), Triangular/round shape with pocket for thermostat complete all as directed
Supply and fix in repairs thermostat ISI marked suitable for the geysers 25 ltrs to 50 lts capacity, 20 Amps, 240 volts AC, adjustable type, 210 mm long or nearest size as per sample
Supply and fix in repairs thermostat ISI marked suitable for the geysers 25 ltrs to 50 lts capacity, 20 Amps, 240 volts AC, fixed type, 300 mm long or nearest size, set at 90+/-6 degree as per sample.
Taking down electric water heater (geyser) of any capacity from existing system, disconnect inlet and outlet water connection for leakage complaint and repair to water inner tank by means of brazing/welding etc. to arrest the leak and refixing the inner tank in outer shell with proper filling of glass wool as heat resistance material in suitable quantity, and refixing the geyser at it's original location and connecting with the water distribution system complete all as specified and directed.
Taking down electric water heater (geyser) of any capacity from existing system, disconnect inlet and outlet water connection for leakage complaint and replacing the rusted, leakage inner water tank with new one made out of steel of following capacity and refixing the inner tank in outer shell with proper filling of glass wool as heat resisitance material in suitable quantity and refixing the geyser at it's original location and connecting with the water distribution system complete all as specified and directed.
Inner water tank of capacity 25 ltrs
Inner water tank of capacity 50 ltrs
Supply and fix in repairs indicators of geysers 25 to 50 ltrs capacity
Supply and fix in repair cable PVC insulated 3 core 2.5 sqmm with stranded copper conductor 1100V grade from socket/switch to geyser
M&L for painting to external surface of geyser of any capacity in one coat of synthetic enamel paint, after removing of all loose paints, rust, dust and all oily particle by washing and making suitable for painting and incl writing MES No with black synthetic enamel paint complete all as specified and directed.
Supply and fix 3 pin plug top, 15 Amp capacity, 240 VAC, heavy duty, ISI marked
M&L for apparatus plate suitable for 25/35/50 ltrs geyser all as per sample
Supply and fix clamp of apparatus plate suitable for geyser as per sample
Supply and fix in replacement of Havell's make ELCB with 1.5 mtr long 3 core cable suitable for Havells geysers (Model Puro Turbo) of 25 ltrs cap .
Supply and fix in replacement flexi connection pipe (Hot & Cold) accessory 450mm long with nuts.
Supply and fix as in repairs Three Pin plug top 5 Amp complete all as specified.
NAGALAND AGENCIES CO
SURANA CORPORATION
M/S P K ROY AND SONS
MS AFTAB LASKAR
m/s builders and suppliers
M/S TAPAN KUMAR RAY
M/S SANJIB DEB
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .