Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.2 LAccepted-AOC 5021 1 CAT III MODERN HOUSING COMPLEX MANIMAJRA CHANDIGARH | CHANDIGARH | CHANDIGARH | 160001 | L1 | Accepted-AOC Quoted L1 | |
| 2 | L2₹12.6 L+₹1.1 L (9.20%)Rejected-AOC 691 INDUSTRIAL AREA PHASE II CHANDIGARH 160 002 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160002 | L2 | Rejected-AOC Quoted L2 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
21 Jul 2023, 6:00 pmClosed
GE AF Chandigarh
GE AF Chandigarh PIN-160003 C/o 56 PO
REPAIRS TO INTERNAL ELECTRIFICATION, MCB DBs AND OTHER FITTINGS AND FIXTURES IN TECHNICAL AREA UNDER GE (AF) CHANDIGARH
2023_MES_605325_1
GE(AF)/CHD/T-26/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
183 days
Chandigarh
All as per NIT and Tender documents
9 documents required · 9 mandatory
₹500
GE AF Chandigarh
₹30,000
Yes
30 Aug 2023
23 Jun 2023
27 Jul 2023
23 Jun 2023
21 Jul 2023
7 Jul 2023
23 Jun 2023 - 30 Jun 2023
Amount
Taking down carefully submain wiring of any size from existing concealed/ surface conduits and making good the disturbed surfaces complete all as specified and directed.
Taking down copper/ aluminium point wiring (light, fan, socket or power) complete, including conduits/ casing capings etc and making good disturbed surface of walls, floors, etc. complete all as directed.
Taking down copper/ aluminium point wiring (light, fan, socket or power) complete from existing concealed/ surface conduits/ casing capings etc and making good disturbed surface of walls, floors, etc. complete all as directed.
M&L for point wiring complete with multi stranded copper conductor cable of size 1.5 sqmm PVC insulated unsheathed FRLS colour coded 1100 volts grade drawn in and including medium grade non metallic rigid PVC conduit 19mm dia or higher fixed on surface/ concealed with all standard fittings such as Tee junction, bends, on existing sunken terminal boxes and new 3mm thick PVC laminated hylam sheet for mounting switch/ sockets etc. including PVC insulated un-shearthed 1.5 sqmm multi-stranded copper conductor cable FRLS colour code cable 1100 volts grade for earth continuity for the following complete all as specified and directed:-
One light point controlled by one switch/ fan point controlled by one switch .
One three pin 6 amp socket outlet multipurpose on independent board.
One three pin 6 Amp switch socket outlet on the same board with other switches.
All as per item No 4.00 above but with 2.5 sqmm size PVC insulated cable for 3 pin 15 amp multipurpose outlet on independent board including 2.5 sqmm PVC insulated copper cable for earth continuity on independent board complete. Note for item No. 4.01 to 4.03 & 5.00: Sunken terminal boxes, if required shall be measured and paid for separately under respective item.
M&L for point wiring complete with multi stranded copper conductor cable of size 1.5 sqmm PVC insulated unsheathed FRLS colour coded 1100 volts grade drawn in existing surface/ concealed conduits and existing sunken terminal boxes and new 3mm thick PVC laminated hylam sheet for mounting switch/ sockets etc. including PVC insulated unshearthed 1.5 sqmm multistranded copper conductor cable FRLS colour code cable 1100 volts grade for earth continuity for the following complete all as specified and directed:-
One light controlled by one switch/ fan point controlled by one switch.
One three pin 6 amp socket outlet multipurpose on independent board.
One three pin 6 Amp switch socket outlet on the same board with other switches.
All as per item No 6.00 above but with 2.5 sqmm size PVC insulated cable for 3 pin 15 amp multipurpose outlet on independent board including 2.5 sqmm PVC insulated copper cable for earth continuity on independent board complete. Note for item No 6.01 to 6.04 & 7.00: Sunken terminal boxes, if required shall be measured and paid for separately under respective item.
M&L for point wiring complete with multi stranded copper conductor cable of size 1.5 sqmm PVC insulated unsheathed FRLS colour coded 1100 volts grade drawn in and including surface/ concealed stove enamelled medium grade ERW steel conduit of size 19/ 20mm dia or higher size with all fittings such as tees, bends etc. including PVC insulated unshearthed 1.5 sqmm multistranded copper conductor cable FRLS colour code cable 1100 volts grade for earth continuity for one light point controlled by one flame proof switch complete all as specified and directed.
M&L for submain wiring complete with two runs of 4.0 sqmm single core, multi-stranded, FRLS PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn through existing surface/ concealed conduits with one run of 4.0 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified. Note: Two runs of 4.0 sqmm multi-stranded cable and one run of 4.0sqmm cable as earth continuity conductor shall be considered as one unit length.
M&L for submain wiring complete with two runs of 6.0 sqmm single core, multi-stranded, FRLS PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn through existing surface/concealed conduits with one run of 6.0 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified. Note: Two runs of 6.0 sqmm multi-stranded cable and one run of 6.0sqmm cable as earth continuity conductor shall be considered as one unit length.
M&L for submain wiring complete with four runs of 10.0 sqmm single core, multi-stranded, FRLS PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn through existing surface/concealed conduits with one run of 10.0 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified. Note: Four runs of 10.0 sqmm multi-stranded cable and one run of 10.0sqmm cable as earth continuity conductor shall be considered as one unit length.
S&F in replacement sheet metal enclosure for incoming MCCB and outgoing MCBs factory made double door, VTPN 415 volts 6 ways with 200 Amp bus bar with IP43 protection complete in all aspects all as specified and directed.
S&F in replacement sheet metal enclosure for incoming MCCB and outgoing MCBs factory made double door, VTPN 415 volts 4 ways with 200 Amp bus bar with IP43 protection complete in all aspects all as specified and directed.
S&F in replacement MCB SP 240 volts 6 to 32 Amps 'B' curve type all as specified and directed.
S&F in replacement MCB SPN 240 volts 6 to 32 Amps ‘B’ curve complete all as specified and directed.
S&F in replacement of MCCB TP 63 to 100 Amps, 415 volts AC, 16 KA with adjustable thermal and magnetic setting complete all as specified.
S&F in replacement LED lights fitting channel and rod type) 4 feet long 1 x 18/ 20 W, 220V, AC decorative box type with driver, holder including LED tube rod connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as directed.
S&F in replacement of MCCB FP 100 Amps, 415 volts AC, 16 KA with adjustable thermal and magnetic setting complete all as specified.
S&F in replacement of MCCB FP 125 Amps, 415 volts AC, 16 KA with adjustable thermal and magnetic setting complete all as specified.
S&F in replacement DB sheet metal enclosure double door for MCB’s company made, SPN 240 Volts 8 ways with IP 42 protection with 200 amps rated bus bars complete all as specified and directed.
S&F in replacement DB sheet metal enclosure double door for MCB’s company made, SPN 240 Volts 4 ways with IP 42 protection with 200 amps rated bus bars complete all as specified and directed.
S&F in replacement MCB SP 240 volts 63 Amps ‘B’ curve complete all as specified and directed.
S&F in replacement flameproof LED light fixture well glass fitting for 60 watt capacity and including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F in replacement LED street light fitting 90 Watt 230 volts AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supply and laying in trenches, fixed on wall (or) passing through pipes/ in floors including connecting up, testing and commissioning of XLPE insulated screened PVC bedded galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sqmm 3½ core including taking up/ down existing cable complete all as specified and directed.
Supply and laying in trenches, fixed on wall (or) passing through pipes/ in floors including connecting up, testing and commissioning of XLPE insulated screened PVC bedded galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sqmm 3½ core including taking up/ down existing cable complete all as specified and directed.
M&L for replacement of LED light fitting 2 x 16/ 20 watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. complete with all accessories duly prewired including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
M&L disconnecting and taking down flame proof tube light fitting of any type, dismantling the same and taking out defective parts, rewinding of complete circuit with new single core FRLS cable of appropriate size, replacing the defective parts such as tube rod/ driver/ bipin holder etc., re-assembling and fixing at original site, making electrical connections and testing for satisfactory working complete all as specified and directed.
Supply and fixing in replacement PVC insulated single core FRLS stranded copper conductor 1100 volt grade cable of size 1.5 sqmm in existing surface/ concealed conduits complete all as specified and directed.
Supply and fixing in replacement PVC insulated single core FRLS stranded copper conductor 1100 volt grade cable of size 2.5 sqmm in existing surface/ concealed conduits complete all as specified and directed.
S&F in replacement flame proof rotary on/ off switch direct entry in LM6, 16 amp single pole 250 volt complete all as directed.
Excavation in trenches in soft/ loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation of pole, laying of cable etc. and getting out complete all as specified and directed.
Returning and filling in excavated soil in layer not exceeding 25cm thick in including spreading, levelling, watering and well ramming in soft/ loose soil complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5mtrs above the starting points complete all as specified and directed.
M&L for sand cushioning to cables with a layer of sand 8cm deep before laying the cable and 15cm depth after laying & stretching of cable) complete all as specified. Note: Punned thickness overall 18cm shall be measured & paid.
Supply and laying old size sub class ‘B’ bricks as in protection of cable laid dry flat perpendicular to direction of cable abutting each other complete all specified and directed.
S&F in replacement flame proof/ weather proof junction box 3/ 4 way 80/ 100mm dia complete all as specified and directed.
S&F in replacement flame proof/ weather proof plug in switch socket 16 amps, 3 pin (2P+E) complete all as specified and directed.
S&F in replacement flame proof/ weather proof plug in switch socket 32 amps, 5 pin (4P+E) complete all as specified and directed.
S&F in repairs LED luminaire 600mm x 600mm, 35/ 36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
S&F in repairs LED luminaire 600mm x 600mm, 35/ 36 watt, 220 V AC surface mounting type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
S&F in replacement rigid non-metallic PVC conduit surface/concealed 25mm dia exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. incuding repairing the disturbed surface complete all as specified and directed.
S&F in replacement of LED flood light luminaries 200W made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP-66 protection system efficacy not less than 110 LPW with 10 KV complete with electrical connections all as specified and directed.
S&F in replacement concealed type flush mounted MS sunken boxes 18 gauge thickness suitable for mounting switch/ sockets complete with earthing terminal and good quality threads incl making good the disturbed surfaces complete all as directed for the following :-
Size 7" x 5"
Size 10" x 8"
Size 12" x 10"
S&F in replacement of switch piano type, flush type, single pole, one way, 6 Amps complete all as specified and directed.
S&F in replacement of socket outlet flush type 2/ 3 pins, 6 Amps multipurpose complete all as specified and directed.
S&F in replacement of switch piano type, flush type, single pole, one way, 16 Amps complete all as specified and directed.
S&F in replacement of socket outlet, flush type, multi purpose 3 pin, 6 Amps & 16 Amps, 230 volts complete all as specified and directed.
S&F in replacement ceiling fan regulators, step type, electronic for 1200/ 1400mm sweep complete all as specified and directed.
S&F in replacement LED lamp 10 watt complete all as specified and directed.
S&F ceiling rose, surface bakelite, 65mm x 50mm, two to three terminals, complete all as specified and directed.
M&L for replacement earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25 Mtr deep below ground level ) with top edge of the plate not less than 1.5 Mtr below normal ground level, connected to galvanised earth lead strip 25mm x 4mm by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No. 3 of SSR Part-I 2009 connected to earthing test point panel all as specified or indicated and testing on completion as directed by the Engineer-in-Charge incl necessary excavation & earth work in any type of soil, funnel, PCC chamber (1:3:6) type C1, CI pit cover and frame , charcol, salt including earth lead protected by 40mm dia medium grade GI pipe and 20mm dia medium grade GI Pipe for watering complete all as specified and directed. Note :- Earth lead strip 25 x 4mm and GI 40mm dia protecion pipe upto 7.5 mtr length will be deemed to include in the unit rate quoted.
PARTAP ENGINEERING WORKS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .