Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.8 LAccepted-Finance 1ST FLOOR SIDHARTH TOWER BALTI KHARKHANA BYELNE S J ROAD ATHGAON GUWAHATI KAMRUP ASSAM 781001 | KAMRUP METRO | ASSAM | 781001 | 1 | Accepted-Finance lowest | |
| 2 | 2₹5.0 L+₹14,108 (2.92%)Accepted-Finance | 2 | Accepted-Finance lowest 2 | |
| 3 | 3₹5.1 L+₹31,548 (6.53%)Accepted-Finance | 3 | Accepted-Finance lowest 3 |
Tender Value
₹4.8 L
EMD Value
₹4,840
Closing Date
20 Feb 2023, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE, EWC, Bareilly
Katju Marg, Bareilly
Increasing capacity of 33/11kv S/S Durganagar in district Bareilly
2023_MVVNL_774717_1
26/EWC(B)/2022-23
Open Tender
Electrical Works
Item Wise
90 days
Durganagar Bareilly
as per tender form
3 documents required · 3 mandatory
₹1,180
A/c No. 019205006347, IFSC Code ICIC0000192
₹4,840
23 Jun 2023
14 Feb 2023
20 Feb 2023
14 Feb 2023
20 Feb 2023
14 Feb 2023
Amount
Note - Any material/Labour required to complete the work (which is not covered in above) will be provided by the firm.
Loading, unloading and safe carriage of the following materials from any Electy. Store Center of Electricity store division of Bareilly zone.
ST Pole 11Mtr. Long
M.S.Channel 100X50X2240mm @ 9.6Kg/Mt. (Top channel & dropper)
M.S angle lron 65x65x6mm, 4300mm long @ 5.8 Kg/Mt (bracing)
11 KV Disc Insulator 45KN
Disc Fittings Dog/Racoon 45 KN
Earthing complete
Stay Set 16X1800 mm complete
11 KV VCB O/G CTR 200/100/5A 350 MVA
11 KV Cable 3x300 Sq. mm XLPE for Transformer
11 KV Cables 3x185 Sq. mm XLPE for feeder
11 KV Cable jointing Kit
Earthing of indoor & outdoor equipments of Sub-Station after proper welding of joints and painting of earth strip above soil with proper clamp etc. as per RESPO approved drawing & resistance of earthing should be not more than 2Ω as per as per details given below. Firm have to submitted jointly signed resistance testing certificate of earthing.
Making of triangular bridge by using 32 mm MS round bar electrode , GI strip 50x6mm and GI Pipe 50 mm dia with providing of well type pipe earthing upto 15 Mtr. depth below ground level including welding etc. by boaring process at T/F neutral and T/F body including cost of GI pipe of size 40 mm dia 15 mtr. long of ISI mark(all the required material will be supplied by the contractor and dully checked by AE (Works).
Supply of GI strip of size 50x6mm for earthing of all newly erected structures and equipments in switchyard including cutting, fixing & proper welding with equipments. All LA will be seprately earth also as per RESPO norms. (All the required materials will be provided by firm and will be inspected by AE (Works) before installation.)
Laying of single CKT 11KV cable of different size from power T/F to control room I/C. 11 KV Cable will be layed in brick trench constructed below 1250mm to the ground level over the ganga sand. brick trench will be constructed by Ist class bricks covering three sides of cable, after laying 11 KV Cable brick trench will be filed by Ganga sand & then will be covered by bricks & backfill of soil over cable trench as per RESSPO norms.
Termination of 11 KV different size XLPE cable by filling suitable 11 KV heat shrinkable type cable boxes including proper connection with LV side of T/F switch gear panel by providing suitable connectors.
Erection of 11 KV outgoing panel (with testing & setting of relays) in substation control room including grouting of Anchor bolts of panel and making of pocket for power cable to insert in panel from trench and complete filling of control room's tranches by river sand.
Erection and grouting of double pole structure of ST Poles including stays for 11KV out door feeders, complete in all respect as per RESSPO drawing along with grouting material about 3 meter 4" dia G.I. pipe along with required elbow shall be provided at D/P for power cable including provision of 02 Nos. feeders name plate on D/P. (All type of insulators, steel, stay set with wire, earthing rod, clamps, GI pipe & grouting material provided by the Firm except PCC pole).
Complete laying and termination of copper control cables from 10 MVA power T/F, existing 33 KV VCB and 33 KV CT in the out door switch yard to the existing Transformer relay control panel inside the control room including cost of all materials and labour required for proper completion of works as per RESSPO drawings, including cost of testing of transformer relay pannel & proper relay settings as per requirement etc.
Repairing of existing 33 KV transformer control relay pannel including its connection and replacement of damage relays.
Safe removal of existing 01 No. 5 MVA T/F after disconnection from 33 KV & 11 KV side & control wiring from buchholz and WTI & OTI & stacking as per decided by site incharge.
Repairing of damage switchyard fencing.
M/S SUPER ENGINEERING TRADERS
M/S MEGHA ENTERPRISES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .