Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.4 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹19.9 L+₹23,898 (1.22%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹21.0 L+₹1.3 L (6.74%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest |
Tender Value
₹22.4 L
EMD Value
₹45,000
Closing Date
19 Nov 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (A) Jaisalmer
HQ CWE (A) JAISALMER 345001 (Raj)
SPL REPAIRS TO BLDG No. P 14 AT PFFR SEC C UNDER AGE(I) POKARAN
2024_MES_681002_1
84239/C/E8
Open Tender
Civil Works
Item Rate
180 days
POKARAN
AS PER NIT
8 documents required · 8 mandatory
₹500
AGE(I) POKARAN
₹45,000
Yes
14 Dec 2024
24 Oct 2024
21 Nov 2024
24 Oct 2024
19 Nov 2024
7 Nov 2024
24 Oct 2024 - 30 Oct 2024
Amount
B&R WORK Demolition of cement concrete unreinforced in ground floors and pavings not exc 15cm thickness below or above ground level etc complete all as specified and directed by engineer-in-charge.
Dismantling of Stone slabs and tiles of any description or thickness in floors, walls, aprons etc, removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by engineer-in-charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by engineer-in-charge.
M&L for 75 mm thick PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in sub base complete all as specified and directed by engineer-in-charge.
M&L for non skid ceramic coloured tiles of 7 to 8mm thick, (square/rectangular) area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqm (including size 400mmx400mm), as in floors etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including screed bed or bedding layer of 15mm thick in CM (1:6) complete all as specified and directed by engineer-in-charge.
M&L for glazed ceramic tiles size 350x250x7mm /450x350x7 mm thick on vertical surfaces, set & joined in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over & including 10mm thick backing coat of CM (1:4) complete all as specified and directed by engineer-in-charge.
M&L for Hand Cut Kota stone flooring 20-25mm thick incl for cuttting and polishing by machine over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including provision of 15 mm thick screed bedding in CM (1:6) complete all as specified and directed by engineer-in-charge.
M&L for machine cut kota stone slab 20 to 25 mm thick as in riser of steps, skirting & dado and laid over cement screed and jointed with pigment to match the shade of the slab including rubbing and polishing complete over and including 15 mm thick backing coat in CM (1:4) complete all as specified and directed by engineer-in-charge.
M&L 20-25mm thick Granite (of any type) work (table rubbed and polished) as in steps, jambs, pillars, window-cills, cooking platfoms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by engineer-in-charge.
M&L for 5cm sand stone slabs in sun shades, chajjas, shelves, cills, landings, cover stones, templates & similar works, etc. n exc. 2m in length, punched dressed on face and along exposed sedes, self faced on other side and set and pointed in cement mortar 1:4 complete all as specified and directed by engineer-in-charge.
M&L for 50mm thick PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in plinth protection and surface finished even and smooth without using extra cement complete all as specified and directed by engineer-in-charge.
Dismantling of Stone slabs in roof, suspended floor, chajjas, landings etc of any description or thickness jointed in any mortar complete all as specified and directed by engineer-in-charge.
M&L for jodhpur stone roof slabs, self faced 7.5cm to 10cm thick, 25cm to 35cm wide, hoisted, set jointed and grouted 1:3 complete all as specified and directed by engineer-in-charge.
All as per serial item No. 13.00 here-in-above but except stones.
M&L for flush pointing single joints in brick work or masonry in detached work, flashings, etc on ceiling complete all as specified and directed by engineer-in-charge.
Complete removal of existing water proofing treatment incl bedding if any n exc. 50mm thick etc. on any type of roof, cleaning with wire brushers etc. and removal of debris out side MD land complete all as specified and directed by engineer-in-charge.
M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate consolidated thickness shall be varied from 25 to 55 mm, for levelling course all as per the requirements complete all as specified and directed by engineer-in-charge.
M&L for 10mm thick screed plaster on roof for laying in CM 1:4 water proofing treatment with using WPC complete all as specified and directed by engineer-in-charge. Note:- WPC will be measured and paid separately under relevant item a
Supply only integral Waterproofing compound complete all as specified and directed by engineer-in-charge.
M&L for water proofing treatment with 3 mm thick APP (Actatic Poly Propylene) modified membrane reinforced with non woven polyester mat of weight 150 gms/sqm as centre core & without multiple layers of polyethylene applied by thermo fusion using LPG torch on the bottom portion of the membrane after applying a coat of bituminous primer of bitumen grade 85/25 @ 1.20 Kg/Sqm over roof (an overlap of 100 mm & 150 mm shall be provided on sides & end respectively ) and applying one coat of aluminium paint @ 100ml/sqm on top of APP membrane to get uniform finish complete all as specified and directed by engineer-in-charge.
Taking down cement plaster on stone walls including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed by engineer-in-charge.
M&L for rendering 15mm thick on stone masonry surfaces in CM (1:6) finished the surface even and smooth without extra cement complete all as specified and directed by engineer-in-charge.
M&L for rendering 15mm thick on stone masonry surfaces or surface other than fair face of brickwork in CM (1:4), the surface even and smooth without extra cement complete all as specified and directed by engineer-in-charge.
M&L for preparation of new plastered surfaces of wall and applying three coats of white wash on wall surface complete all as specified and directed by engineer-in-charge.
M&L for preparation of new plastered surfaces and applying three coats of white wash on ceiling complete all as specified and directed by engineer-in-charge.
M&L for preparation of new plastered surfaces of wall and applying two coats of cement base paint on wall over a coat of priming complete all as specified and directed by engineer-in-charge.
M&L for complete removal of existing treatment of wall surfaces and applying two coat of white wash on surfaces of wall complete all as specified and directed by engineer-in-charge.
M&L for complete removal of existing treatment of wall surfaces and applying one coats of cement base paint complete all as specified and directed by engineer-in-charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc. 1.50 sqm each and removing from site and making good disturbed surface of walls in cement mortar (1:3) complete all as specified and directed by engineer-in-charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc. 1.50 sqm but not exc. 4 Sqm each and removing from site and making good disturbed surface of walls in cement mortar (1:3) complete all as specified and directed by engineer-in-charge.
S&F framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete Fe 410-W (GdeE- 250) qualityA complete all as specified and directed by engineer-in-charge.
S & F 2nd class HW 35mm thick, factory made, plain framed, paneled shutter (Two panels) with panels of 9mm thick BWP grade ply wood bonded with high quality liquid phenol formal dehyde synthetic resin adhesive conforming to IS-710. The size of rails & style shall be as per IS-1003 (part-I) kiln seasoned as per IS-1141 & chemically pressure treated as per IS-401 complete all as specified and directed by engineer-in-charge.
M&L for IInd class hard wood Glazed and skeleton shutters, 35 mm thick , open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, cla-use 8.20 (a); supplied and fitted to chowkats complete all as specified and directed by engineer-in-charge.
S&F factory made Box Type steel window with side hung shutters including projecting type hinges with steel handle, and steel peg stay , complete without glazing bars, dovetailed or complete as shown in Drawing No. CEJZ/TD/22 sheet 1/1 to 1/3 complete all as specified and directed by engineer-in-charge.
S&F Factory made Box Type steel ventilators fixed type, including with one shop coat of primer complete as shown in Drawing No. CEJZ/TD/24 sh 1/1 to 1/3, and complete all as specified and directed by engineer-in-charge.
S&F framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con-foRming to Fe 290.Gde-E-165 complete all as specified and directed by engineer-in-charge.
S&F stainless steel wire cloth 0.36mm nominal dia of wire & average width of aperture 1.40mm & fixed with wire staples complete all as specified and directed by engineer-in-charge.
S&F 4.00 mm thick sheet glass, ordinary quality & glazing with oil putty not exc 0.50 Sqm each pane complete all as specified and directed by engineer-in-charge.
S&F mild steel butt hinges, medium weight, cold rolled, ISI marked of size 100 mm complete all as specified and directed by engineer-in-charge.
S&F aluminium, anodised, barrel tower bolt of extruded section, ISI marked, 150 mm long complete all as specified and directed by engineer-in-charge.
S & F extruded aluminium handle fabricated type, anodised 150mm size conforming to IS complete all as specified and directed by engineer-in-charge.
S & F 300mm long aluminium alloy,anodised, sliding door bolts with hasps, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed by engineer-in-charge.
S&F in repairs decorative type curtain rod, stainless steel, 25 mm dia with not less than 1mm wall thickness complete all as specified and directed by engineer-in-charge.
S&F in repair decorative type brackets , stainless steel, suitable for 25mm dia curtain rod complete all as specified and directed by engineer-in-charge.
M&L for preparation of new wooden surface over 10cm width or girth and applying two coats of synthetic enamel paint of Ist quality over a coat of pink primer complete all as specified and directed by engineer-in-charge.
M&L for preparation of new steel surface over 10cm width or grith & applying two coats of synthetic enamel paint of 1st quality over a coat of red oxide primer complete all as specified and directed by engineer-in-charge.
Demolition of stone/ boulder masonry and built in cement mortar including all quoins arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles and removal unserviceable materials, debris and rubbish to a distance not exceeding 100m complete all as specified and directed by engineer-in-charge.
M&L for squared rubble walling, Jodhpur type, brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar (1:6) complete all as specified and directed by engineer-in-charge.
Extra over stone walling for hammer dressing to face stones with maximum depression on face from a straight edge not exceeding 20mm & dressing face beds and joints as specified to squared rubble walling Jodhpur type brought up to courses complete all as specified and directed by engineer-in-charge.
M&L for Flush Pointing single joints in brickwork or masonry in detached work, flashings, etc. on wall in CM (1:4) complete all as specified and directed by engineer-in-charge.
Dismantling of water tanks and removing to store capacity of tank exc. 500 but not exc 1000 ltr complete all as specified and directed by Engineer-in-Charge.
S&F rotational moulded polyethylene water storage tanks ( cylindrical vertical with closed top ) hoisted and fixed in position all as specified in SSR part-I ,1000 ltr capacity and fixed complete all as specified and directed by Engineer-in-Charge.
Taking up or down 15mm bore steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified and directed by Engineer-in-Charge.
Taking up or down 20mm bore steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified and directed by Engineer-in-Charge.
Cutting chases, pinning in stone concrete block or slab walls, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed by Engineer-in-Charge.
S&F 15mm bore tubing, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors and testing for leakages complete all as specified and directed by Engineer-in-Charge.
S&F 20mm bore tubing, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors and testing for leakages complete all as specified and directed by Engineer-in-Charge.
S&F in repair 15mm bore Gun metal gate valves with iron wheel head screwd both ends for iron pipes complete all as specified and directed by Engineer-in-Charge.
S&F in repair 20mm bore Gun metal gate valves with iron wheel head screwd both ends for iron pipes complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 15mm dia bib taps cast cipper alloy chromoum plated fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed by Engineer-in-Charge.
S&F in repair stop valves, cast copper alloy, screwed down, high pressure, with crutch or butter fly handle, fancy type, chromium plated, screwed both ends for iron pipe or for unions 15mm bore complete all as specified and directed by Engineer-in-Charge.
S&F in repair sinks made of stainless steel with drainage board 1mm thick kitchen or laboratory with plugs, washers and wastes : including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed by Engineer-in-Charge.
E&M WORK Taking down carefully point wiring of any type (i.e., on wooden batten, surface conduit, casing-N- capping or concealed conduit) complete for light, fan socket or power point with fittingS&Fixtures such as ceiling rose, electric fittings, holders, switches, sockets, regulators, wooden batten, conduit etc. including accessories such as wooden gutties/rawal plug, screw etc including making good disturbed surface to match the existing surface complete all as specified and directed by engineer-in-charge.
Taking down carefully by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. for reuse at site or carrying to the store (To be measured only when found serviceable in all respects complete for reuse) complete all as specified and directed by engineer-in-charge.
M&L for point wiring complete with 1.5 Sqmm single core PVC insulated cable 1100 Volts grade multistranded copper conductor drawn through in PVC Casing and Capping on surface stone/brick, masonry walls, roofs floors etc including MS terminal boxes fabricaterd out of 1.12mm thick MS sheet sunk type / surface type and laminated top sheet of 2mm thick for housing switches sockets, regulators etc including provn of 1.5 sqmm dia copper conductor for earth wire connected to common dolly for One light point / Fan point / Exhuast Fan point controlled by one 5 Amps One way switch all as specified and directed by Engineer-in-Charge
All as per Item No. 65.00 here-in-before but for one 3 pin 5/6 Amps switch socket outlet on same board
All as per Item No. 65.00 here-in-before but for one 3 pin 5/6 Amps switch socket outlet on independent board
All as per item No. 65.00 here-in-before but for one socket outlet/metal clad socket of 15/16 Amps fixed on independent board with 4.0 Sq mm multistranded copper conductor wire FRLS PVC insulated and 4.0 Sq mm copper conductor wire FRLS PVC insulated using as earth wire complete all as specified and directed.
S&F switch piano, flush type, single pole, one way 5 amps 230 Volts AC confirming to IS: 3854 and ISI marked complete all as specified and directed by engineer-in-charge.
S&F switch piano, flush type single pole, one way 15 amps 230 Volts AC confirming to IS: 3854 and ISI marked complete all as specified and directed by engineer-in-charge.
S&F switch sockets combination outlet multipurpose 2 pin, 5/6 Amps flush type ISI marked controlled by one switch 5 Amps complete all as specified and directed by engineer-in-charge.
S&F universal socket outlet with shutter 5/15 Amp flush type controlled by one switch 15 Amps complete all as specified and directed by engineer-in-charge.
S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd complete all as specified and directed by engineer-in-charge.
S&F Lamp holder PVC polycarbonate type with back plate suitable for battern fittings complete all as specified and directed by engineer-in-charge.
S&F LED lamp retro fit type 9 watts 230 Volt complete all as specified and directed by engineer-in-charge.
S&F Ceiling rose, 3 phase/PVC/polycarbonate, isolated body complete all as specified and directed by engineer-in-charge.
S&F sheet metal enclosure MCB DB TPN 4 way made out of 1.5 mm thick sheet metal enclosure IP 43 with 200 Amps rated bus bar 415 volts double door with PVC MCB blanking plates, stove enamelled, dust and vermin proof suitable for incorporation of MCBs and isolators etc complete all as specified and directed by Engineer-in-charge.
S&F for sheet metal enclosure MCB SPN DB 8 way made out of 1.5 mm thick sheet metal enclosure IP 43 with 200 Amps rated bus bar 240 volts double door with PVC MCB blanking plates, stove enamelled, dust and vermin proof suitable for incorporation of MCBs and isolators etc complete all as specified and directed by Engineer-in-charge.
S&F MCB TPN 415 volts, 63 Amps, 10 KA, " C " Series complete all as specified and directed by Engineer-in-charge.
S&F MCB SPN 240 volts, 40 Amps, 10 KA 'C' series fixing in DBs including connecting with bottle type copper thimble complete all as specified and directed by engineer-in-charge.
S&F MCB SP 240 volts, 6 to 32 Amps, 10 KA 'C' series fixing in DBs including connecting with bottle type copper thimble complete all as specified and directed by engineer-in-charge.
Supply and laying sub main wiring with two runs of 4 Sq mm single core PVC insulated unsheathed cable upto and including 1100 volts grade with multistranded copper conductor drawn through in PVC Casing and Capping on surface walls, floors etc including one run of 2.5 Sqmm PVC insulated copper conductor for earth continuity wire complete all as specified and directed by engineer-in-charge. Note : Two runs of 4.00 Sqmm copper conductor and one run of 2.5 Sqmm copper earth wire will be measured and paid as one unit only.
M&L for earthing complete with GI plate electrode 600x600x6mm thick burried directly and preferably vertically in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below ground level connected to GI earthing lead of 4mm dia GI steel wire all as shown in plate No 4 of SSR part (2009) to earthing test point including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete pit PCC (1:3:6) type C-1 (with 20mm graded aggregate). 50 mm thick precast RCC (1:2:4) cover slable (re-inforced with 8mm dia TMT bar @ 15 cm both ways and suitable handle made of 10mm dia ) including necessary earth work in excavation, returning filling, and removal of surplus earth upto a distance exceeding 50 mtr etc. all as shown in electric plate No 2 of SSR part-2 complete all as specified and directed by engineer-in-charge.
S&F LED light fitting 1x 20 watt, 220V, AC decorative box type with driver holder including LED tube light connecting up with three flexible copper conductor cable with suitable size from ceiling rose complete all as specified and directed by engineer-in-charge.
S&F new generation energy saving and environment friendly long life versatile pressure die cast aluminium IP 66 road way light fitting with high power LED as light source of capacity 20 Watts with suitable drivers etc fixing to wall/pole and including iron bracket of 'medium grade' pipe 40 mm bore, length 1.50m, bend to required shape with 2 Set clamps made of 30x4mm FI and also including taking down old unserviceable street light fitting of any type and capacity complete all as specified and directed by Engineer-in-charge. Make :- Havells Cat No. VILUMINASL20WLED757SASYBOPC or equivalent make and model as approved by AGE.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out hard/dense soil complete all as specified and directed by Engineer-in-Charge.
Returning, filling in including spreading, levelling, watering & well ramming in layers n.exc 25cm complete all as specified and directed by Engineer-in-Charge.
Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by engineer-in-charge.
S&F 25mm bore tubing, 'medium grade' galvanised, with all fitting and laid in trenchesand testing for leakages including taking down old unserviceable 25mm dia complete all as specified and directed by engineer-in-charge.
S&F in repair 25mm bore Gun metal gate valves with iron wheel head screwd both ends for iron pipes complete all as specified and directed by Engineer-in-Charge.
S&F in repair 20mm dia ball brass valves, high pressure with polythene float and fly nut alongwith socket/reducer of suitable size, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed by Engineer-in-Charge.
Cutting the existing road straight by manual, depth and width not less than 30 cm for pipes up to 100 mm dia and 60 cm for pipes from 150 mm to 150 mm dia and 75 cm for pipes above 250 mm dia and filling back with excavated soil up to 75 % road portion and 25 % shall be made with cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) complete all as specified and directed by engineer-in-charge.
Cutting existing CI pipe line for insertion of new tees, collars for branch connections complete all as specified and directed for the size upto 80mm dia complete all as specified and directed by engineer-in-charge.
Supply and laying in trenches/fixed to walls/poles etc and commissioning XLPE insulated and PVC sheathed heavy duty LT 1100 Volts grade armoured under ground cable with aluminium conductor of 3.5 Core 25 Sqmm including taking down of existing cable complete all as specified and directed by engineer-in-charge. Note :- Earth work excavation, sand cushioning and brick protection shall be measured and paid separately.
M&L for Jodhpur stone for lintels, beams and roofs, self faced, 7.5 to 10cm thick for layingin trenches for protection of cable complete all as specified and directed by engineer-in-charge.
Supply and spread approved sand for foundations/Cable duct including watering and consolidation, cushioning of cable laid in trenches complete all as specified and directed by engineer-in-charge. Note:- Punned thickness will be measured for payment purpose
Supply and laying GI tubing of size 40 mm bore light grade for cable protection at road crossing / on poles and tubing sealed at both ends after laying the cables complete all as directed by Engineer-in-Charge
M/s Rashid Mohammed (BID ID -3163598)
Habib Traders (BID ID -3162587)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .