| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.4 LAccepted-AOC KRISHNAGAR DIST NADIA | NADIA | WEST BENGAL | 741101 | L1 | Accepted-AOC AOC | |
| 2 | L2₹9.4 L+₹2,890 (0.31%)Rejected-Finance 25 NEW MALLICK COLONY PAT BARI LANE KOLKATA 57 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700057 | L2 | Rejected-Finance Rejected as L2 | |
| 3 | L3₹9.5 L+₹4,335 (0.46%)Rejected-Finance | L3 | Rejected-Finance Rejected as L3 |
Tender Value
Refer Docs
EMD Value
₹18,866
Closing Date
21 Feb 2025, 10:20 amClosed
Executive Engineer
Dist Hospital Campus Saktinagar Krishnagar Nadia
Internal EI work at GNM Training School Nadia District Hospital Shaktinagar Campus Krishnagar Nadia
2025_WBPWD_812734_1
WBPWD/EE/NED/NIQ/e-T/90/ (1st Call)24-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
35 days
Dist Hospital Campus Saktinagar Krishnagar Nadia
Please refer Tender documents.
5 documents required · 5 mandatory
₹18,866
3 Apr 2025
7 Feb 2025
24 Feb 2025
7 Feb 2025
21 Feb 2025
7 Feb 2025
Amount
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe (for horizontal & vertical run in wall and celing portion through prelaid polythen pipe) complete with all accessories embedded in wall [only PVC Rigid Conduit on ceiling and remaining portion concealed] Average run 8 mtr [ 5C/ E-15]
On Board [ 3 (i) / E- 20 ]
Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch, 16A Modular switch type MCB as per GS.[12 /E-18 ]
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and as per GS .[5(a)/ E-17 ][For AC ]
Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl as per GS [17/E-19] [For AC ]
Supply of 5 A, piano key type Switch. [K-2/ 77]
Supply of 20 A, piano key type Switch. [K-2/ 81]
Supply of 5 A, 3 pin Piano flush type Socket. [K-2/ 82]
Supply of 15A flushed type 3 pin Plug Socket [K-2/ 83]
Supply of 20/25A Plug Top [K-3/ 113]
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC [E-14/1-a(i)]
2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC [E-14/1-a(ii)]
2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC [E-14/1-a(iii)]
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. i) 2.5 sqmm [9 /F-5]
ii) 4 sqmm [9 /F-5]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as per GS [Make-Legrand ] i) 63 A FP [ 6 / D- 5 ]
ii) 40 A DP [ 6 / D- 5 ]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [ Make -Legrand ] I) 6-32 A SP [ 7 / D- 6]
ii) 63A TP [ 7 / D- 6]
Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) as per GS [18(a) / E-6]
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. [21-a/C-3]
S & F 1200mm sweep AC ceiling fan with out regulator, complete with P2 burst proof Capacitor, Down rod, blades, canopy, rigidly connected Safty Tie wire etc. Incl. other accessories as necessary. (Make - Cromton / Usha / Orient)
Supply of 230V , 50Hz ,400 mm sweep heavy duty full metal body wall bracket fan (Cabin fan) complete with all accessories having the following Model / Cat No. ( Make -EPC )
Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length. [29/C-4]
Fixing only exhaust fan after making holes in wall as per GS (9") [ 28(a)/C-4 ]
S & F of louver shutter on wall with necy bolts & Nuts (6mm dia x 62 mm Long) For Al. 9 " Ex. Fan [D-14/32a]
Supply of Heavy Duty Exhaust fans complete with all accessories having the following Model / Cat No. (Make -EPC/Crompton/Orient/Havells.) 9" ( 225mm ) Speed 1370 RPM
Fixing only single/twin LED light fitting in the ceiling fixed with “L” type MS clamp as per GS [17/C-2]
Fixing only single/twin fluorescent light fitting complete with all accessories directly on wall/ceiling by screws etc. [17/C-2]
Supply & Deliver of 4 feet Industrial box type Twin LED fitting including S & D of 2X20 wattt LED( Polycarbonate) with glare free light distribution with CCT (5000K) 6500 K), with minimum luminious efficacy ≥105 & <120 lumen/watt or better. The LED Lamp and accessories shall have BEE Certification.
Supply & Deliver of 4 feet Industrial box type single LED fitting including S & D of 1X20 wattt LED( Polycarbonate) with glare free light distribution with CCT (5000K) 6500 K), with minimum luminious efficacy ≥105 & <120 lumen/watt or better. The LED Lamp and accessories shall have BEE Certification.
Supply of LED T8 tube light with PC body ( Cat no. LT8-20-865-2) (Make: philips/ Crompton)
S&F of 240V, 120 watt LED flood light IP66 protection with CCT (5700-6500) & minimum Luminious efficacy>= 110/120 Lumen/Watt. 10kv spd to be orderd separatelyb(Make: Panasonic /Crompton/wipro/Jaquar/Bajaj/ Havells)
S&F of 240V, 70 watt or higher, LED Street Light including IP65 protection with CCT (5700-6500) & minimum Luminious efficacy>= 110 Lumen/Watt. (Make: Panasonic /Crompton/wipro/Jaquar/Bajaj/ Havells)
Supply of 4 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Polycab / Gloster/ Havells] 2 Core 6 Sqmm for Compund Light
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish . (i) From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc. [F-3 /5- i ]
Supplying and fixing compression type gland and Finishing those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS. 2 core 6 Sq. mm [7(c)/F4 & 8(b)/F5 ]
Supplying & fixing earth busbar including Connecting the equipments of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall as per GS [4(a)/G-2 ]
Excavation of soil for installation of Earth Electrode and filling & ramming. For soft Soil [ 1(a)/G-1 ]
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With ISI-Medium GI pipe as per GS [ 2(a)/G-1 ]
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages [G-2/5iii] No. 8 SWG
S&F AC Timer DB(Water Proof) concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment and febricated with following items as per instructions of EIC i) 240 V, 6-32 A SPMCB of breaking capacity 10KA & "C" Charecteristic - 01 no ii) 240V 40 A DP MCB Isolator on din rail --- 01 No. iii) 240V, 2P, Power Contractor (rating above 20 Amp) with accessories ---- 01 no iv) Astronomical timer switch --- 01 no v) Toggle switch for manual/auto operation... O1 no. vi) Double door 2+6 Way SPNDB... 1No vii) Necessary connection by copper wire. [Make:-ABB/Siemens/Legrand/L&T or as per EIC]
BISWAJIT PAUL (BID ID -6144816)
MS T CON (BID ID -6144898)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .