Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.6 CrAccepted-AOC | ₹8.6 Cr | L1 | Accepted-AOC Being the lowest tenderer (L1) |
| 2 | L2₹10.3 Cr+₹1.7 Cr (19.3%)Rejected-Finance | ₹10.3 Cr+₹1.7 Cr (19.3%) | L2 | Rejected-Finance Not being the lowest. |
| 3 | Rejected-Technical | - | - | Rejected-Technical Being three class below |
Tender Value
Refer Docs
EMD Value
₹7.4 L
Closing Date
11 Jan 2021, 6:00 pmClosed
Chief Engineer (Navy) Mumbai
Chief Engineer (Navy) Mumbai, 26 Assaye Buildings, Colaba, Mumbai 400005
PROVN OF AUDITORIUM CUM CINEMA HALL AT NAVAL BASE PORBANDAR
2019_MES_254186_5
87735/E8
Open Tender
Civil Works
Lump-sum
630 days
PORBANDAR
As per tender documents
9 documents required · 9 mandatory
₹3,000
GE (I) Navy Porbandar
₹7.4 L
23 Feb 2021
23 Nov 2020
13 Jan 2021
23 Nov 2020
11 Jan 2021
28 Dec 2020
Amount
SCH 'A' PART-I "BUILDINGS & STRUCTURES" Total of Sch-'A' Part-I B/F from Serial Page No.27
SCH 'A' PART- II "SITE CLEARANCE, EXCAVATION & EARTH WORK. Total of Sch "A" Part-II B/F from Sl page No 29
SCH 'A' PART-III "INTERNAL WATER SUPPLY" Total of Sch "A" Part-III B/F from Sl page No 31
SCH 'A' PART-IV "INTERNAL ELECTRIFICATION" Total of Sch "A" Part-IV B/F from Serial Page No 34
SCH 'A' PART-V "ROAD/ PATH / CULVERTS" Total of Sch "A" Part-V B/F from Serial Page No 36
SCH 'A' PART-VI "AREA DRAINAGE " Total of Sch "A" Part-VI B/F from Serial Page No 37
SCH 'A' PART-VII "COMPOUND WALL AND FENCING" Total of Sch "A" Part-VII B/F from Serial Page No 39
SCH 'A' PART- VIII "FIRE FIGHTING" Total of Sch "A" Part-VIlI B/F from Serial Page No 42
SCH 'A' PART-IX ""LIGHTIENING PROTECTION"" Total of Sch "A" Part-IX B/F from Serial Page No 43
SCH 'A' PART-X "SEWAGE DISPOSAL" Total of Sch "A" Part -X B/F from on Serial Page No 45
SCH 'A' PART-XI "EXTERNAL WATER SUPPLY" Total of Sch "A" Part-XI B/F from Serial Page No 46
SCH 'A' PART-XII "EXTERNAL ELECTRIFICATION" Total of Sch "A" Part-XII B/F from Serial Page No 50
SCH 'A' PART-XIII "COOLING APPLIANCES" Total of Sch "A" Part-XVI B/F from Serial Page No 51
SCH 'A' PART- XIV" MISCELLANEOUS ITEMS"
"INTERNAL ELECTRIFICATION"
Supply and Fix Lamp holder insulated body with back plate and including LED Lamp 9 Watt for angle holder all as specified. Make: Havells/LEGRAND/Anchor/Leader
S & F LED light fittings decorative 36/34 Watt Recess/surface mounting type extruded metal/aluminium body, and electronic LED driver, connector block ect. with all accessories internal prewired & including connecting up with 2 core flexible cppper conductor cable with suitable size and mounting clamps etc. Make- WIPRO /HAVELLS /JAQUAR /PHILLIPS
S & F LED light fittings decorative 36/34 Watt surface mounting type extruded metal/aluminium body, and electronic LED driver, connector block ect. with all accessories internal prewired & including connecting up with 2 core flexible cppper conductor cable with suitable size and mounting clamps etc. Make- WIPRO /HAVELLS /JAQUAR /PHILLIPS
S &F LED tube light fittings decorative ultra slim linear fixture with extrudedalluminium heat sink envioromentel friendly Energy efficient ready to use pack ,1x18/20 Watt ,4 feet,surface mounting type extruded pvc, snap on installers and domestic electronic Driver ,connector block ect.with all assoceries intenallt prewired & includingconeecting up with 2 core flexible cppper conductor cable with sutable size & suitable for and mounting clamps PVC squre box 75x75mm - 2 nosetc. make-WIPRO /HAVELLS /JAQUAR /PHILLIPS
S &F LED tube light fittings decorative ultra slim linear fixture with extrudedalluminium heat sink envioromentel friendly Energy efficient ready to use pack ,1x10 Watt ,2 feet,surface mounting type extruded pvc, snap on installers and domestic electronic Driver ,connector block ect.with all assoceries intenallt prewired & includingconeecting up with 2 core flexible cppper conductor cable with sutable size & suitable for and mounting clamps PVC squre box 75x75mm - 2 nosetc. make- WIPRO /HAVELLS /JAQUAR /PHILLIPS
Supply and fixing LED Step light ,3 watt in duly powder coated aluminium die cast housing. IP65. Cat no-HLOSTL-06-03 cw of Halonix or Crompton/Philips.
Supply and fixing LED Entry/ Exit sign light ,5 watt in CRCA powder coated with clear acrylic, screen printed/ etching /deep engraving display. Cat no-HLESL-01-05 cw of Halonix or Crompton/Philips.
Supply and fixingrecess mounting round LED down lighter (white light) ,12 watt in glare free opel diffuser with 100 lm/w system .IP 20. Cat no-HLDLR-14-12-NW of Halonix or equivalent in Crompton/Philips.
Supply and fixingrecess mounting round LED down lighter (yellow light) ,12 watt in glare free opel diffuser with 100 lm/w system .IP 20. Cat no-HLDLR-14-12-NW of Halonix or equivalent in Crompton/Philips.
Supply and fixing recess mounting round LED down lighter with dimmer 9 watt in glare free opel diffuser with 100 lm/w system .IP 20. Cat no-HLDLR-14-9-WW of Halonix or equivalent in Crompton/Philips.
Area Flood light fitting LED 220 Watts, energy saving environmental friendly, long life exclusive innovatiive die cast aluminium IP 66 flood light with high power LED as light source suitable for high lighting architectural features or retail spaces FloodTune is easy to use, reliable and cost effective color changing outdoor flood light for creating dynamic lighting effects by just using your smart phone to control lights. Make : WIPRO /HAVELLS JETA linear/JAQUAR /PHILLIPS
S & F LED Security/Street light fittings 15 Watt wall mounting type extruded metal/aluminium body, and electronic LED driver, ect. with all accessories internal prewired & including connecting up with 2 core flexible cppper conductor cable with suitable size etc. Make- WIPRO /HAVELLS /JAQUAR /PHILLIPS
Fabricate,supply & fix GI pipe bracket 25mm dia- 0.9m long & 2 set of clamps made out of 30x5mm ms flat & fixed with anchor bolt suitable for 15w ssecurity light fitting
S & F MCCB DB VERTICAL TYPE , suitable for 125 amps MCCB as incommer,made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, IP-43-IK09 protection grade , 415Volts TPN with 8 way Double door , L&T CAT NO-DBVTL008DD/ LEGRAND CAT NO-607915/ schneider/ ABB (stage Power points)
S & F MCCB DB VERTICAL TYPE , suitable for 125 amps MCCB as incommer,made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, IP-43-IK09 protection grade , 415Volts TPN with 4 way Double door , L&T CAT NO-DBVTL004DD/ LEGRAND CAT NO-607913/ / schneider/ ABB ( for stage lighting & projection room )
S & F MCB TP 415 Volts, 'C' series, breaking capacity 10 KA of rating 63Amps
S & F MCB SPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 40 Amps
S & F MCB SPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 6-32Amps
S & F MCB SP 40 Amps 'C' series, breaking capacity 10 KA of rating
S & F MCB SP 6-32 Amps 'C' series, breaking capacity 10 KA of rating
S & F MCCB 63 A 25 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu & L&T /Legrand /schneider
NOTE FOR ITEM NO 15.14 TO 15.21 - MAKE OF MCCB & MCB - LEGRAND/HAGER/SCHNEIDER/l&T
S&F Exhaust fan heavy duty of size 225 mm sweep PVC body complete with and louvers connecting up including provision of three core flexible copper wire of size 23/0.0076 from ceiling rose to exhaust fan. Make Make , - Havells/Crompton Greaves/Bajaj
S&F Energy efficient BEE five star rated ceiling fan, 1200 mm sweep and connecting up including provision of three core flexible copper wire of size 23/0076 from ceiling rose to ceiling fan complete in all respect all as specified and directed. ( for Tech Building & Adm Building ) -Make : Crompton Greaves/ Bajaj/Orient
Supply & fixing wall mounted fan 450 mm sweep high speed, thermally protected motor, heavy duty gear box, 90 degree oscillation for wide coverage conforming to IS-2997-1964 all as specified and directed by Engineer-in-Charge. , Make-Havells/Crompton Greaves/Bajaj/Orient
Supply & fixing wall mounted Aircirculator fan 600 mm sweep high speed, thermally protected motor, heavy duty gear box, 90 degree oscillation for wide coverage conforming to IS-2997-1964 all as specified and directed by Engineer-in-Charge. , Make-Havells/Crompton Greaves/Bajaj/Orient
M&L for non metalic PVC rigid conduit of size 25 mm dia including bend ,tee,elbow reducer fixing accessorries
M&L for PVC junction box up to 4 Way
Supply, Installation, test and Commissioning CPRI approved factory fabricated, Indoor type, LT Pannel Board made out of 2.00 mm thick CRCA Sheet dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Test-ing after Installation including complete all as specified and comprising of the following :–Make of MCCB/MCB -LEGRAND/L&T/HEGGER/SCHNEIDER (location - Metre room )
(a)MCCB 160 A 25 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu & L&T /Legrand /schneider -01 No. (incoming)
(b)MCCB 63 A 25 KA, 3 POLE ,thermal magnetic relese, Ics=100% Icu & L&T /Legrand /schneider -04 No. (outgoing)
(c)MCCB 40 A 25 KA, 2 POLE ,thermal magnetic relese, Ics=100% Icu & L&T /Legrand /schneider -02 No. (outgoing)
(d)MCCB 32 A 25 KA, 2 POLE ,thermal magnetic relese, Ics=100% Icu & L&T /Legrand /schneider -03 No. (outgoing)
(e) Aluminum TPN bus bar 250 Amps - 01 Set
(h) LED TYPE indicator lamp 1 set (set of three for R,Y,B)
(j) elecronic energy trivactor meter- 01 No,suitable for 3 phase 4 wire CT operated ,temper proof,operated on 240v AC ,three phase, 5 amps to 10 amps, base mounting meter, backlit LCD display with user friendly legend, accuracy class-0.5, MD recording, revenue protection ( in case of wrong electric connection),capability to disply & communicate ( in case of absence of main supply), with optical port,deficiency metering with either phase/netral current, IP 51 protection, as per IS13779 including CT,make of meter -L&T model no- ER300P & Cat no-WR300BC5200 of L&T or equivalant of secure
Supply and fix Indoor Commercial down lighters compact IC track mounted CDMA spot light multiple beam angle Type MRS 553 C 1 X CDM-RIII-35WEB IC WH alongwith accssories for mounting of projectors type RCS170 IC LI1000WH complete all as specified by engr in charge .
FIRE FIGHTING SYSTEM
S & F of hooter mounted with line matching transformer min 100 dB output in acoustically treated box complete as specified
Supplying, installing and jointing of 16 guage MS conduits 25mm dia on surface or concealed with junction boxes, cover plates, MS bends, GI saddles, base and other accessories all made in MS with GI screws as required. (Note: Exposed conduit shall be painted with red enamel paint for identification. MS conduit used in concealed shall be treated in anti corrosive epoxy paint before laying)
Supply, drawing connecting testing & commissioning of 2 runs of single core 1.5 sqmm stranded PVC insulated copper wire FR in existing conduit for MCP/Hooter with thimbles and ferrules in existing board
Supplying, installing, testing & commissioning of Zonal fire alarm control panel for 14 Nos MCP and 14 Nos hooters, conventional type with battery charger and batteries for 12 hours backup supply to fire alarm system and LED illuminated mimic diagram on 6 mm thick acrylic sheet. The panel shall have terminals for connecting fire alarm & communication cables from central fire control room.
Supplying, installation testing & commssioing of central fire alarm repeat panel (central fire alarm control panel) conventional type for zonal fire alarm control panels with battery charge and battries for 12 hours backup supply to fire alarm system and LED illuminated mimic diagram on 6mm thick acrylic sheet. The panel shall have terminals for connecting fire alarm & communication cables from zonal fire control room.
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, out door type, LT panel board ,made out of 3.15 mm thick CRCA Sheet with projected Globe roof for rain water protection Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation including complete all as specified and comprising of the following :–Make of MCCB/MCB -MDS/LEGRAND/L&T/HEGGER ( Fire Booster pump )
(a) Aluminium bus bar 200 Amps TPN -01 Set
(b) MCCB 4 Pole 63 Amps 25 KA -01 (incoming)
(f) MCCB 3 pole 32 Amps 10 KA -02 (for pump)
(g) star- delta starter panel mounted of cap 12.5 HP (01 No)
(f) LED TYPE indicator lamp 1 set (set of three for R,Y,B)
(g) Single phasing preventer -02 No
(h) Digital hour meter-03 Nos
Supply and Fix Foot Value for 100 mm dia Body-Forged Stainless Stell to ASTM A 182, Gr 316, Flanged End/Screwed end, Pressure rating PN 2.4 to 2.5 complete all as specified and as directed.
Fire Extinguisher Dry Chemical powder[ABC] type 6 Kg capacity. Ceasefire 9kg fire extinguisher mono Ammonium phosphate powder 50, stored pressure type, pressure Guage, Gross weight 15.6 Kg, empty weight 5.6 KG, can height 611 MM, Diameter 175 MM, discharge time less than 18 secs, controllable discharge mechanism, Range minimum 4 mtrs, applicable on class A,B,C & electrically started fire A rating 27A, B rating 558, can construction deep down & CO2 Mig welded, Valve construction : Forging & Machining internal coating of can : Epoxy powder coating external coating of Can : Epoxy polyster powder coating, Sheet metal thickness : 1.80MM, ISI and EN approved, 5 years warranty.Make Cease Fire ABC Powder Map 10 5Kg - 1AB06CF
Fire Extinguisher Carbon Dioxide type of 4.5Kg capacity.Ceasefire 4.5kg CO2 Gas typre fire Extinguisher, Trolly mounted, Easy weight management Used Unused Mechanism Squeeze Grip, Gross weight 9.1kg empty weight 14.6kg, Can height 857MM, Diameter 140MM, Discharge timeless than 10secs controllable discharge mechanism Applicable on class B&C fire, B rating 21B, Can Construction : Hot Spinning/ Forging, Valve Construction : Forging & Machining, Internal coating of Can : Not Applicable, External Coating of Can : Spray painting sheet metal thickness 4.5MM, ISI Approved 1 year warranty. Make Cease Fire CO2-4.5Kg - Squeeze Grip - 1CO11CF
M & L for fabrication, supply and installtion of MS pedastal type fire point made out of anlge iron frame (50x5mm) free standing on ground/hard standing suitable for provsion of hanging and including 4 Nos fire buckets 13 ltrs capacity each complete with painting with post office red colour including red oxide as perimer and writing letters FIRE on outer surafce of fire buckets, wirting FIRE POINT on fire stand all as per IS specification
Fire Extinguisher mechanical Foam type trolly mouted of 9 Liters capacity.Ceasefire 9litrs fire Extinguisher AFFF Foam type , External Cartridge type, Pressure Guage Gross weight 14.6 Kg , empty weight 5.6 Kg, Can height 611 MM, Diameter 175 MM, Discharge timeless than 60 Secs controllable discharge mechanism, Minimum 6 Mtrs, Applicable on Class A,B,Can construction deep deawn & CO2 Mig welded Valve Constyruction : Forging & Machining, Internal coating of can : Epoxy powder coating, External coating of can : Epoxy poyster powder coating sheet metal thickness 2.0MM ,1 year warranty. Make Cease Fire AFFF - Foam 9 Ltr - 1FM02CF
Fire Extinguisher dry chemical powder trolly moutnted Ceasefire 25 Kg Fire Extinguisher MONO Ammonium Phosphate powder 90, Gross weight 125Kg, Empty weight 75KG, Can height 1190MM, Diameter Discharge Time leass than 50 Secs controllable discharge mechanism range minimum 8Mtrs, Applicable on class A,B,C & electrically started fire, Can Construction deep drawn and CO2 Mig welded valve construction Forging & machining internal coating of Can, Epoxy powder coating External coating of Can Epoxy Polyster powder coating sheet metal thickness 5.00MM 1 year warranty. Make Cease Fire.Make Cease Fire ABC Powder map 90 50Kg - 1MP50CF
M & L for Fire Extinguisher Dry Chemical powder (ABC) type 9 Kg capacity. Ceasefire 9 Kg fire extinguisher mono Ammonium phosphate powder 50, stored pressure type, pressure Guage, Gross weight 15.6 Kg, empty weight 5.6 KG, can height 611 MM, Diameter 175 MM, discharge time less than 18 secs, controllable discharge mechanism, Range minimum 4 mtrs, applicable on class A,B,C, & electrically started fire A rating 27A, B rating 558, can construction deep down and CO2 mig welded valve construction : Forging & Machining internal coating of can : Epoxy powder coating external coating of Can : Epoxy polyster powder coating Sheet metal thickness : 1.80 MM, ISI and EN approved, 5 years warranty. Make cease Fire ABC Powder Map 10.5 Kg – 1AB06CF
S & F installing testing and commissioning pressure switch suitable pressure range 0-14 bar , having die cast aluminium construction S/S sensing element with ball valve and including all fitting set to suitable pressure as per requirement duly wired up to motor starter panel
External Water Supply
Supply and laying Ductile iron pipes with spigot and socket ends centrifugally cast, Class K-9, in any length laid in trenches of size 80 mm dia Including rubbur Tytan joint complete all as specified and as directed.
Supply and fix CI sluice valve 80 mm dia both ends flanged and drilled, bonnet wedge stuffing box. Gland trust plate, hand wheel made out of grey CI, complete valve confirming to IS 14846/2000 and its fittings suitable for hydraulic test pressure of 15 Kg/sqcm PN 1.0 ISI marked complete all as specified and directed. Make: Kirloskar/Upadhyay/L&T MAKE
Supply and fix CI sluice valve 150 mm dia both ends flanged and drilled, bonnet wedge stuffing box. Gland trust plate, hand wheel made out of grey CI, complete valve confirming to IS 14846/2000 and its fittings suitable for hydraulic test pressure of 15 Kg/sqcm PN 1.0 ISI marked complete all as specified and directed. Make: Kirloskar/Upadhyay/L&T MAKE
Supply and fix Non Return Valve (reflux valve) with with by pass arrangement GM working parts confirming to IS- 5312, 80 mm (3") dia complete all as specified and as directed.
S & F Non return valve (reflux valve) with with by pass arrangement GM working parts confirming to IS- 5312, 150 mm (6") dia
Supply and fix foot valve with GM working parts conforming to IS- 4038, 80 mm (3") dia
Supply and laid spigot/flanged/ socketed DI fittings. Such as bends (any type radius and angle), tapers, tees, collars & tail piece socket/flanged/spigot etc of size 80mm to 300 mm dia.
Supply and fix cast iron air Valve withsingle air outlets , conforming to IS 14845 for cast iron water supply mains of size 200 mm dia complete all as specified and as directed.
M & L for Construction of fly-ash brick masonary valve chamber of size 900 mm X 900 mm X 1000 mm (internal dimenssions) with PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate, 150 mm thick & 150 mm wide offsets around over 100 mm thick hardcore , 200 mm thick fly-ash brick masonry walls built in CM 1:6, 100 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in cement mortar (1:6) finished even and smooth, with out using extra cement internally including top of floor including excavation earth work in soft rock /hard Dense soil , 6 mm thick MS sheet cover fixed on 25 mm X 25 mm X 6 mm thick angle iron frame with hold fasts embedded in PCC coping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil / rock to a distance not exceeding 50 m etc complete all as specified and directed.
All as per item here-in- before but size 600m x 600 mm x 600 mm complete all as specified and as directed.
"DG SET"
(a) Supplying, installing, testing and commissioning, factory assembled silent Diesel Engine driven generator set, fully wired alternator AC to give an out put of 160 KVA continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 Hz ± 1% supply, 1500RPM, directly coupled with diesel engine liquid cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, PCC foundation work as per manufacturer's instructions, vibration damper pads, control panel & other accessories etc and comprising of following.
(b)Diesel Engine: Liquid cooled turbo charged with after cooler to deliver suitable BHP at 1500RPM under NTP conditions of BS 5514 and conforming to IS 10002, DIN 6271 & ISO 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories:. Diesel engine of rated speed at full load electric start developing with system with radiator and including electronic governor control of class A1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries of adequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete. Make: Kirloskar/ashok leyland/cummins
(a) Radiator with blower fan or heat exchanger with guard. (b) Pipe coupling for engine cooling system piping. (c ) Corrosion inhibitor coolant (d) Paper element filters (i) Fuel filter (ii) Lube oil filter (iii) By pass (e) Fly wheel housing and fly wheel to suit alternator. (f) Engine bearing mechanism in fly wheel housing. (g) Shut off coil with safeties for LLOP/HWT/over speed. (h) Dry type air cleaners and vacuum indicators. (j) Residential silencers. (k) Stainless steel exhaust flexible bellows. (l) Motor driven priming pump. (m) Battery charging alternator. (n) Exhaust piping made out of STIC C class, MS pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturer's recommendations to sustain back pressure with rain cap. (o) Mineral wool insulation 2 inch thick suitable for 400 degree Celsius temperature cladded with aluminium sheet o 30 gauge for the entire length of exhaust pipe. (p) First fill of oil, coolant and diesel during commissioning and 12 hours testing.
(q) Interconnecting copper cabling of adequate capacity batteries control. (r ) Fuel pipe class STIC 1" /1.5" /2" dia - 01 lot (s) Self starter 12 volts DC. (t) Electric operated electronic governor. (u) Fuel injection pump. (v) Electronic instrument panel, complete with all accessories as per manufacturer's specifications displaying the following:- (i) 24V Battery. (ii) Water temperature. (iii) lubricating oil pressure. (iv) Engine speed -1500Rpm (v) Engine hours (vi) Frequency. (vii) Voltage. (w) Safety control (Trip and indication). (i) High water temperature (ii) Low lube oil temperature (iii) Overspeed stop (x) Base frame: Sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturer's design alonwith AVM pads. (y) Battery:-24 volts(02x12vBattery) DC, 180AH, maintenance free battery conforming to IS:14257 with leads & terminals (Make- Excide/Amron). (z) Fuel tank: 10 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick HR/MS sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling fro exterior canopy (without opening its panel) etc complete all as specified and directed.
(c) Alternator: Suitable rated 160 KVA, 0.8 pf , 415 volts, 3 phase, 4 wire, 50 Hz at 1500 RPM, self excited and self regulated with AVR brushles, screen protected, drip proof , insulation class-H, IP -23, voltage regulation grade - VG 3 self ventilated and conforming to BS: 5000 / IS: 4722 suitable for engine as mentioned here-in before, conformig to IS: 13364(part-1) Make: stampford/crompton/kirloskar
(d) Acoustic Enclosure:- M & L for acoustic enclosure for the above 160 KVA DG set to reduce noise level to 75 dB measured at 1.0 meter distance for audible frequencies as per guide of Central Pollution Control Board and size 3490 x 1340 x 1885mm and manufacturer's specification and comprising of following from authorised GOEMs of Gen Set manufacturer's specified :-
(i) Sound insulation : 100mm thick Rock wool (Density 64 Kg/Cum). (ii) Outer body : 1.6mm thick CRCA (iii) Door : 1.6mm thick CRCA (iv) Base frame : ISMC 300 (v) Inside illumination : 1 No.- 1 x 18 watt FTL fitting of make Phillips/ Bajaj/ Crompton.
(e) AMF Control panel:- Factory fabricated cubicle type, free standing, floor mounted, indoor type, IP-52, AMF control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0mm thick CRCA sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following:
(f) AMF control circuit with 4 pole MCCB 250 Amps - 2 nos, with ultimate breaking capacity Icu-36 KA at 415 volts and microprocessor release conforming to IEC 60947 Part-I with breaking capacity Ics=Icu at 415 volts , thermal overload setting 70% to 100%, short circuit setting 5 to 10 times-02 Nos. for main supply & DG set supply with HRC back up fuse complete with all DC control relays/ Line voltage monitor (LVM) as per OEM specifications incorporating motorised stored energy operating Engine start, stop, three attempt starting facility and failure to start etc.
(g) Digital load manager : Three phase 4 wire indicating V,I,PF, KVA, KW, F of Enercon make with serial communication port model No.EM6400 with class 1.0 accuracy meter or equivalent make suitable rating of CT per phase- one No. (iii) Indication lamp R, Y, B with 3 Nos. of 2A HRC fuses-10 sets. (iv) Bottom gland plate for incoming and outgoing cables. (v) Circuit diagram plate.
(h) Civil works:- All civil works related to foundation, installation of panel and equipment & depth of foundation shall be minimum 300mm with ant vibration pads, or as recommended by manufacturers. Cable from DG set to AMF panel, AMF panel to main panel will be measured under relevant schedule. Note:-The fuel for final testing of 12 hours shall be supplied by the contractor and cost deemed to be included in the above offer. All other necessary equipments like resistance load strip heater of suitable capacity/rating and any other items required for final testing shall be provided by the contractor without any extra cost to department.
Supply, Installation, test and Commissioning CPRI approved factory fabricated, indoor type, LT Pannel Board made out of 3.15 mm thick CRCA Sheet with projected globe roof for rain water protection dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Test-ing after Installation including complete all as specified and comprising of the following :–Make of MCCB/MCB -LEGRAND/L&T/HEGGER/SCHNEIDER (Location - FOR DG SET )
INCOMING:-
(a) MCCB 250 A 35 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu & L&T /Legrand /schneider - 1 no
OUTGOINGS:-
(a) MCCB TP 160 Amps , 415Volts, 35KA ,3 POLE, L&T CAT NO-CM92008OOM1OG/ LEGRAND CAT NO-420087 / equivalent of ABB- 2 NOS (O/G) (for MAIN BUILDING & AC PLANT)
(b) MCCB TP 100 Amps , 415Volts, 35KA ,3 POLE- 01 NO (FF PUMPS) L&T CAT NO-SL98652OOOO/ LEGRAND CAT NO-420085 / equivalent of ABB -
(C) MCCB TP 40 Amps , 415Volts, 35KA ,3 POLE ,thermal magnetic relese, Ics=100% Icu & L&T cat no- SL98602OOOO /Legrand cat no-420013/schneider cat no-LV510316 - 2 nos (water supply Pump)
(d) Aluminum TPN bus bar 400 Amps - 01 Set
(g) LED TYPE indicator lamp 1 set (set of three for R,Y,B)
Earthing complete with galvanized steel earth plate electrode 600mm x600 mm x 6mm buried directly in ground vertically to a depth not less then 2.25 meter below normal ground level with top edge of the plate not less then 1.50 meter below normal ground level connected to galvanized earth 32 x 6mm GI strip by means of bolts ,nuts ,check nuts and washers complete up to and including test point made out of 40 x 6mm alum flat including earthing pit , charcoal common salt,Earthing lead 32x6 up to 7.5m, 20mm dia medium grade GI watering pipe ,PPC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate ,PCC pit cover including earth work complete all as shown in electrical plate No-5 of SSR-2014 (part-I) NOTE-: GI earth strip shall be measured and paid for separately under relevant item of schedule .[ 02 Nos External water supply + 14 Nos External Electrification + 04 Nos fire protection + 10 Nos Lightning protection + 06 Nos DG set + 02 Nos Internal Electrification + 04 Nos AC work]
Earthing complete with galvanized steel earth plate electrode 600mm x600 mm x 6mm buried directly in ground vertically to a depth not less then 2.25 meter below normal ground level with top edge of the plate not less then 1.50 meter below normal ground level connected to galvanized earth wire 4.00 mmdia by means of bolts ,nuts ,check nuts and washers complete up to and including test point made out of 40 x 6mm alum flat including earthing pit , charcoal common salt ,Earthing lead 4.00mm dia up to 7.5m, 20mm dia medium grade GI watering pipe ,G.I. protection pipe 15 mm dia up to 7.5m long,,PPC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate ,PCC pit cover including earth work complete all as shown in electrical plate No-5 of SSR-2014 (part-I) [ 04 Nos Internal Electrification +06 nos fire fighting + 04 nos ext water supply+ 03 nos Ext Elect + 06 Nos AC work] ]
EXTERNAL ELETRIFICATION:
S & F LED Bolard light fittings 6 Watt wall mounting type extruded metal/aluminium body, and electronic LED driver, etc. with all accessories internal prewired & including connecting up with 2 core flexible cppper conductor cable with suitable size etc. Make- WIPRO /HAVELLS /JAQUAR /PHILLIPS
Supply and Fix for AVIATION LIGHT type,LED TYPE IP 65 protection cat no -SLE AL 54 -LDR-SEN IP65 of SURYA /BAJAJ cat no -BGAV 302 LED/PHILIPS
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure
Supply and fix LED street light fitting 45 Watts complete with bracket made out of 40mm dia GI light grade tubing not less than 1.5mtr long bent to shape 120 deg including pole clamps (2 nos), clamp for fixing GI pipe bracket made out of 50x6mm flat and nut bolts etc all as directed
S&F decorative type 30W LED Post Top Lantern luminaire with diffuser and painted aluminium deflector Light fitting complete make C&S code No LTGL30-24X1HPLED/eq of Phillips/ Surya /Bajaj with suitable GI pipe light grade for mounting the fitting all as per directed by Engr-in-Charge
Supply & fix PVC junction box IP 65 Protection of size 0.200 x 0.250 x 0.115 complete with 1 Nos of MCB SP 2.5 Amps & 4 way industrial connector including Clamp made out of MS flat 30X5 mm, connection from junction box to street light fitting with three single core PVC insulated , PVC sheathed wire 2.5 Sqmm copper & PVC conduit 20 mm dia. Make of Box- SPELS BERG/RITTAL/HENSEL CAT NO K8350
Supply and fix cable route indicator made of round CI disc embossed HT Cable, of size 16cm dia 6mm thick duly revited with angle of size 50x50x4mm and 60cm long including PCC 1:2:4 B2 using 20mm aggregate 15cm x 15cm x 15cm for grouting the same complete all as specified.
Supply and fix cable route indicator made of round CI disc embossed HT Cable, of size 16cm dia 6mm thick duly revited with angle of size 50x50x4mm and 60cm long including PCC 1:2:4 B2 using 20mm aggregate 15cm x 15cm x 15cm for grouting the same complete all as specified.
Supply, Installation, test and Commissioning CPRI approved factory fabricated, out door type, LT Panel Board made out of 3.15 mm thick CRCA Sheet with projected globe roof for rain water protection dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation complete all as specified and comprising of the following :–Make of MCCB/MCB -LEGRAND/L&T/HEGGER/SCHNEIDER (location - near transformer)
(a) Aluminum TPN bus bar 600 Amps - 01 Set
(b) MCCB 400 A 35 KA,4 POLE ,thermal magnetic release, Ics=100% Icu & L&T cat no- CM94105OOR1OG /Legrand cat no-025538/schneider cat No-LV540309 - 1 No.
(c)MCCB 250 A 35 KA, 3 POLE ,thermal magnetic release, Ics=100% Icu & L&T cat no-CM92009OOP1OG /Legrand cat no-420239/schneider cat no-LV525333 -02Nos(amf pannel/spare)
(d) MCCB 160 A 35 KA,3 POLE ,thermal magnetic release, Ics=100% Icu & L&T cat no-CM92008OOM1OG/ LEGRAND CAT NO-420087 / equivalent of ABB - 1 No (for APFC)
BLANK
(f) MCCB 40 Amps TP ,25 KA -2 No (out going street lights & spare)
(g) LED TYPE indicator lamp 1 set (set of three for R,Y,B)
(h) Astronomical, Multifunctional digital time switches cat no 004767 of legrand or equivalent of L & T cat no- T2 DD T7/MDS/GIC - 1 No
(j )Power contactor ML-3 , 3 pole rating not less than 40 A with 230 coil make L&T/SEIMENS - 1 No.
(k ) MCB SPN 6 Amps-1 No.
Supply, install, testing and commisioning of Distribution transformer mounted on masonry platform stepdown , 11KV/ 0.433KV , Three Phase complying with IS: 1180(Part-2) 2014 with latest amendments , indoor type double copper wound suitable for 50 Hz system of capacity 200 KVA, oil immersed naturally cooled delta connected on HT side and Star connected on LT side ,Vector Group Dyn11, provided with OFF load tap changer to vary secondary voltage from -7.5% to + 7.5 % in step of 2.5 %. Losses should be confined to the limits specified as follows: :maximum allowable losses at full load (100 % ) & Half Load ( 50 % )shall not be exceeded 1.35 % & 0.93 % respectivly as per GRAHA RATING, Percentage Impedance: 5%. Losses and Impedance are subjected to tolerance as specified in IS 1180. The transformers should be supplied with first filling of oil confirming to IS 335 .The transformer should have both side cable end box with neutral brought out complete all as directed by Engineer - in -Charge, and installation of transformer shall be carried out as per IS-10028 and comprising with the following standard fittings/Technical specifications : -
(a) Lifting lug for transformer and tank.
(b) Earthing terminal rating and diagram plate.
(c ) Air release device.
(d) Oil filling inlet pipe with plug.
(e) Drain outlet pipe with brass gate valve.
(f) Conservator tank with oil level indicator
(g) Silica jel breather
(j) First fill of oil upto level including conservator tank with fresh new oil conforming to IS335.
(k) Type of connection Delta/Star
(l) Type of cooling: Oil and Natural Air.
(m) Vector group:DYN 11.
(n) Temperature rise over an ambient of 50 °C maximum.
(o) Cable end box on both side for HT/LT cables of suitable size.
(p) Provision of thermometer with pocket.
(q) Provision of oil and winding temperature gauge.
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, indoor type, APFC capacitor bank Panel Board of size as recommended by manufacturer 40 KVAR with 6 steps ( 12.5+12.5+5+ 5+5) WITH MD-XL CAPACITOR AND MCCB AS INCOMER Automatic Power Factor Correction panel , made out of 2 mm thick CRCA Sheet Dust and Vermin Proof, single door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System,The enclosure shall be pre-treated as per 11 tanks process and finished with powder coating of shade RAL 7032. , including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Testing after Installation complete all as specified .The panel shall be factory fabricated comprising of following. Make of pannel L&T/ SCHNEIDER/ABB
(A) INCOMER
MCCB 160 A 35 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu & DN2-250D,CAT NO- CM920083OOM1OG- 1 no (Thermal Magnetic Release)
ROM+SPDR - 1 no
Auxiliary 1 c/o +TAC 1 c/o- 1 no
12.5 KVAr Capacitor feeder comprising of:- ( 2 Nos. )
40A, BUSSMANN FUSE- 6 NOS
Thyristor switching module 25kVAR, 440V,TSM,LTTSM - 2 NOS
7% Detuned Aluminium Reactor 12.5KVAr 440V LTAL,CAT NO-0712B2- 2 NOS
Ultra heavy duty capacior LTXL , BOX type oil Filled Capacitor bank 15 kVAr,sutable for 480V - 02 nos
Push Button ON/OFF -4nos
Indicating lamps 4 NOS
Auxiliary Contactor {2NO+2NC} 24V DC Coil Voltage MXO- 2
6A DP MCB , C CURVE 2 NOS
5 KVAr Capacitor feeder comprising of:- (3 Nos. )
16A, BUSSMANN FUSE 9 nos
Thyristor switching module 10kVAR, 440V,TSM,LTTSM
7% Detuned Aluminium Reactor 5 KVAr 440V,LTAL,CAT NO-0712B2-3 no
Ultra heavy duty capacior LTXL , BOX type oil Filled Capacitor bank 7.5 kVAr,sutable for 480V ,LTXL- 3nos
Push Button ON/OFF -6nos
Indicating lamps 6 NOS
Auxiliary Contactor {2NO+2NC} 24V DC Coil Voltage MXO- 3
6A DP MCB , C CURVE 3 NOS
APFC relay 8 stage {BLR CM – 06T MB } -1 NO [230/ 110 V, 1/5A, 50 Hz] [Transistor output + Single CT sensing + RS 485 MODBUS]
Digital Voltmeter (3Ph, Class 1) -1 NO
Digital Ameter (3Ph, Class 1, 5A) -1 NO
Metering CT --/5A, Class-1- 3 NOS
SMPS 5A, Input 230V AC Output 24V DC -1 NO
ON Delay Timer 0-10 Sec.,Coil 24V DC -1 NO
Auxiliary Contactor {4NO} with 24V DC}-3 NOS
Indicating Lamp(R,Y,B)-3 NOS
6A SP MCB-3 NOS
6A DP MCB
6A FP MCB -1 NO
8" {EBM NADI} Fan -1 NO
FIRE ALARAM AND FIRE SENSORS SYSTEM
Network card product code CF-HFP APS-NIC
Isolator Base fully monitored for short/Open circuit compatible with ESP Analogue Addressable Protocol,Electronically addressed, approved by LPCB,unit incorporated an amber LED to show when it is isolating a section of a Loop product code CF-YBO-R/ SCI(WHT /SNDR) SCI (TI-000087)
Analogue Addressable Manual Call Point having status LED for Alarming & standby mode,inbuild short circuit isolator,Electronically addressed approved by LPCB as EN54-11: 2001 . Rapid response using operation of a call point to the system indicating fire condition is typically less than 1.5 seconds FAST addressing technique Flexible (programmed in any sequence), Automatic (stored in EEPROM), Secure (cannot be changed easily) and Time saving. product code CF-HCP-E(HFP)-SCI (TI-002056)+CF-SR Mounting Box (TI-000120)
Analogue Addressable Dual Input Module which allow 2 independently controled change over relays,Relays operated at 30 V DC at 1 Amps having auxiliary monitored input, followed by ESP Analogue Addressable Protocol,Electronically addressed, approved by LPCB. product code CF-CHQ-DIM(SCI)(WHT) (TI-000094)+CF-Backbox for Modules (TI-000099)
Analogue Addressable Dual Relay Controller which allow 2 independently controled change over relays,Relays operated at 30 V DC at 1 Amps having auxiliary monitored input, followed by ESP Analogue Addressable Protocol,Electronically addressed, approved by LPCB. product code CF-CHQ-DRC(SCI)(WHT) (TI-000095)+CF-Backbox for Modules (TI-000099)
Response Indicator for Above False Ceiling .
4C x 1.5 sqmm Armoured cable. ISI marked
2 X 1.5 sqmm Flexible Unarmoured cable. ISI marked
2 X 1.5 sqmm Armoured cable. ISI marked
25mm PVC Conduit
RO PLANT
Supply and install hit purification capacity 50 ltrs/hr water purifier mineral RO technology- double purification by RO+UF with TDS controller suitable for attachement to water cooler all as specified and directed. Make Kent Elite-II or equivalent in Aquaguard / Pureit as approved.
STAGE LIGHTING
Supply and fix Indoor Commercial down lighters compact IC track mounted CDMA spot light multiple beam angle Type MRS 553 C 1 X CDM-RIII-35WEB IC WH alongwith accssories for mounting of projectors type RCS170 IC LI1000WH complete all as specified by engr in charge .
COOLING APPLIANCES : Supply and fix voltage stabilizer for automatic operation single phased naturally air cooled 170 V to 250 V with output voltage stabilized at 230 volts with accuracy of 2.5% and of capacity 2.0 KVA complete all as specified by engr in charge .
PA EQPIMENTS AND VIDEO PROJECTION SYSTEM
Front Fill Loudspeaker System (R & L) Ceiling Mount Speaker (Front Left & Right) : Speaker type : 2 Way bass reflex, Frequency range (-10dB) : 50Hz-20KHz , Nominal coverage : 90x40 , Components : 15” cone, 1.75”, Ti vc, CD-Horn, Power rating : PGM 500W , SPL : Sensitivity (1W ; 1m on axis) 98dB SPL, Nominal impedance : 8Ω , Yamaha R115/panasonic/Bose/Ahuja
Speaker Riging : Speaker Mount & Riging Hardware for Yamaha R115 (Area : Front Speaker) For Hanging arrangement of Speaker.
Stage Lip Monitoring Loudspeakers System Floor Monitor Speaker : Speaker type : Floor Monitor Speaker : Speaker type : 2-way bass reflex , Frequency range (-10dB) : 55Hz-20KHz , Nominal coverage : 40x90 , Components : 12” cone , 1.75 , Ti vc, CD-Horn , Power rating : PGM 400w , SPL : Sensitivity (1W; 1m on axis) 97dB SPL , Nominal impedance : 8Ω Yamaha R112//Panasinic/Bose/Ahuja.
. Monitor Speaker on Side Wall behind Stage wings : Speaker type : 2-way bass reflex , Frequency range (-10dB) : 50Hz-20KHz , Nominal coverage : 90x40 , Components : 12” cone , 1.75 , Ti vc, CD-Horn , Power rating : PGM 400W , SPL : Sensitivity (1W; 1m on axis) 97dB SPL , Nominal impedance : 8Ω Yamaha R112.
Speaker Brackets : For Hanging arrangement of Speaker on side walls or over head on stage.
Subwoofer System Subwoofer : Speaker type : Bass reflex , Frequency range (-10dB) : 35Hz-3KHz , Components : 18” cone , Power rating : 1000W , SPL : Sensitivity (1W; 1m on axis) 97dB SPL , Peak SPL (128dB) Nominal impedance : 8Ω Yamaha R118/panasinic/Bose/Ahuja.
Delay Loudspeaker System Delay Speaker (Left & Right) : Speaker type : 2-way, Bass-reflex, Frequency range (-10dB) : 51Hz-20kHz , Nominal coverage : H (100) x V (100) , Components : 8” Cone & 1” Soft dome , Power rating : 180W , Nominal impedance : 8Ω/60W(170 Ω ), 30W (330 Ω), 15W (670 Ω) , SPL : 117dB SPL Yamaha VXS8/panasinic/Bose/Ahuja.
Green Room Speakers if any Speaker (Guest Lounge & Green Room ) : Frequency range (-10dB) : 80Hz-20kHz , Nominal coverage : H (90) x V (90) , Components :6.5”(160mm) cone driver , 1” (25mm) balanced dome tweeter , Power rating : PGM 50W , Nominal impedance : 8Ω/15W, 7.5W, 3.8W SPL : 110dB SPL (100W) Yamaha VS6/panasinic/Bose/Ahuja.
Power Amplifier for Guest lounge & green room : Output power 1kHz (THD+N=1%: 3Ω) 100Wx2 (20ms Burst) ; 1kHz (THD+N=1%: 4Ω) 120Wx2 (20ms Burst) ; 1kHz (THD+N=1%: 8Ω) 100Wx2 (20ms Burst) ; High impedance : 100V line 120Wx2 or 200Wx1 ; High impedance 70V line 120Wx2 or 200Wx1 ; Total harmonic distortion <0.2% (Line in to Speaker out, Half power @ 1KHz, 3Ω/4Ω/8Ω),____(Line in to Speaker out, Half Power @ 1kHz, 70V/100V, 120W/200W) Yamaha PA2120/panasinic/Bose/Ahuja
Amplification for Speakers Power Amplifier for main speakers ,floor monitors & subwoofers : 2x1000W at 8Ω ; 2x1200W at 4Ω ; Newly developed Class –D amplifier engine with a custom LSI ; Flexible onboard PEQ, crossover, filters, delay and limiter functions ; Yamaha Speaker presets ; Utilities for safe and secure operation ; Output power ; 1kHz Non-clip 20msec Burst Both channels driven 8Ω ; 1000Wx2 ; 4Ω ; 1200Wx2 ; 2Ω ; 700Wx2 , Yamaha Px10
Power Amplifier : 2x800W at 8Ω ; 2x1050W at 4Ω ; Newly developed Class –D amplifier engine with a custom LSI ; Flexible onboard PEQ, crossover, filters, delay and limiter functions ; Yamaha Speaker presets ; Utilities for safe and secure operation ; Sampling frequency rate Internal 48kHz A/D D/A Converters AD/DA : 24-bit linear, 128 times over sampling ; Total harmonic distortion 0.1% (1kHz, 10W), 0.3% (1kHz, Half power) ; Frequency response ± 1.0dB (1W, 8Ω, 20Hz to 20kHz), Yamaha Px8/Panasinic/Bose/Ahuja
Power Amplifiers for surround speakers : 2x300W at 8Ω ; 2x500W at 4Ω ; Newly developed class –D amplifier engine with a custom LSI ; Flexible onboard PEQ, crossover, filters, delay and limiter functions ; Yamaha Speaker presets ; Utilities for safe and secure operation ; 8Ω/Power Boost Mode 600Wx1 4Ω/ Power Boost Mode 1000Wx1 ; Sampling frequency rate Internal 48kHz ; A/D D/A Converters, AD/DA : 24-bit linear, 128 times over sampling , Yamaha Px5
Digital Signal Processors Digital Signal Processor : Mixing channels : Mixing Channel : 8 Mono + 3 Stereo + 2 Effect Return + 8 Direct in to Matrix/Output Busses : 8 Mono , Input channel functions : Mono CH : 3-band PEQ, Comp, Gate, Auto Gain Control, Feedback suppressor (only available in ch 1-4)/ Stereo CH : 3-band PEQ, Comp, Auto Gain Control , Output channel functions : Room Delay , Room EQ, Speaker Processor, X-Over (1way, 2Way), Delay, 6-band PEQ, Limiter, Yamaha MTX3/DBX 260 Drive Rack
Analog Mixing Console Analog Mixer : Mixing channels 24 Line inputs (16 mono and 4 stereo) ; GROUP 4 GROUP Buses + ST Bus ; AUX 6 AUX Sends + 2 FX Sends ; MATRIX 1 Matrix out ; On-board processors FX1:REV-X(8 PROGRAM, PARAMETER control)/FX2:SPX(16 PROGRAM, PARAMETER control) Yamaha MGP32X/panasinic /Bose/Ahuja
MICROPHONES Wired & Multi Channel Wireless System Wired Microphone : Microphone Unit Dynamic ; Polar Pattern Unidirectional ; Frequency Response 40Hz-15kHz ; Sensitivity (2.83 V/1m)-54dB ± 3dB (0dB =1V/Pa at 1kHz) ; Output Impedance 500 ohms ± 30% (at 1kHz) ; Connector 3 pin XLR-M type ; Cable Ø 6mmx5m cable with XLR-F type connector and 6.3mm plug, Yamaha DM-105/ panasinic /Bose/Ahuja
. High quality microphones tuned for clear lead and backup vocals : Microphones Unit Dynamic Polar Pattern Unidirectional Frequency Response 40 Hz-15 kHz Sensitivity (2.83 V/1m) -54dB ± 3dB (0dB =1V/Pa at 1kHz) , Output Impedance 500 ohms ± 30 % (at 1kHz) Connector 3 pin XLR-M type Cable _Ø 6mmx5m cable with XLR-F type connector and 6.3mm plug Dimensions (Microphone only) Ø 51mm x 169mm ,, Q1/Cibas/Studiomaster/ panasinic /Bose/Ahuja
Miscellaneous Equipments 18. PA Powered Lectern System Powered Podium : I. Built-in 60 Watts Amplifier (4 Ohms Output) II. Built-in Three 4 inches Woofers and One 2 Inches Tweeter III. Built –in Dual Wireless Microphone (Dual Hand or One Hand + One Tie Microphone) IV. Two Flexible Gooseneck Microphone and One Reading Lamp, V. External Speaker Connection available VI. Foldable Laptop Table In-Built USB Player with Bluetooth and Recording Facility Make – mega/panasinic/ Bose/Ahuja
Input Source : Console with Dual CD Player Cum USB Player all-in-one console combines the functionally of a CD/MP3 Player, a 2-Channel Audio Mixer and a MIDI Controller with XLR outputs.
. Equipment Rack : Equipment Rack for housing all rack mountable equipments with internal wiring , front glass door; heat dissipation fans; movement wheels, power distribution units etc.
UL Listed connectors : For inter connection of equipments. Make-Seetronics
Floor Boxes : Container for electrical connections, usually intended to conceal them from sight and deter tampering.
. Wall Boxes : For Connection of mics.
Microphone stand (big) : Long Stands for microphone make – Hercules
Microphone stand (Small) : Long Stands for microphone make – Hercules
Professional Stereo Headphones : Headphones deliver world-class audio performance, comfort, and durability to professional’s. High impedance and maximized power handling optimize the headphones for use on high-output DJ mixers. Comfortable, padded ear cups swivel 90 degrees and allow easy placement on one ear when mixing. Replaceable cable and included set of replacement ear pads ensure a long-lasting lifetime of use. Also includes a carrying bag and a threaded 1/4” (6.3)mm gold-plated adapter. Features *High impedance and maximized power handing for mixers *Enchanced frequency response tuned to deliver high-output bass with extended highs Closed-back, circumaural design rests comfortably over the ears and reduces background noise *Ajustable, collapsible headband with 90-degree swivel ear cups for comfort and easy one-ear placement *Lengendary Shure quality to withstand the rigours of everyday use *Bayonet Clip securely locks cable into ear cup Replaceable ear cup pads ensure long product life *3m (10ft) coiled detachable cable provides plenty of length and easy storage *Carrying bag protects headphones when on the go or not in use
Snake Cable Long drum : LOSEN/SUNRISE 16 Pair Bulk CL-2 Multi-pair Snake Cable Each channel is 24 gauge, individually shielded, jacketed and numbered. Meets NEC code for permanent installation. Cables are built with the hard-working, hard-touring musician or audio professional in mind. AWI cables are exceedingly high-quality cable lines in the fix installations and live shows for their durability and excellent performance make-LOSEN & SUNRISE SNK-16
Speaker Cable for 2.5 Sq. mm 200/40 Subwoofers : Cable with thickness of Core 2.5 Sqmm. Use for all audio applications with Double Diamond Protection Highest quality stranded copper wire for maximum flexibility and covered with a tough PVC jacket to help prevent chafing, Wire should be designed to maximize sound quality and for better frequency response Cable with thickness of 2 Core 2.5 Sq. mm make-LOSEN & SUNRISE
Speaker Cable for 1.5 Sq. mm 100/40 Main Speakers : Cable with thickness of 2 Core 1.5 Sqmm. Use for all audio applications with Double Diamond Protection Highest quality stranded copper wire for maximum flexibility and covered with a tough PVC jacket to help prevent chafing, Wire should be designed to maximize sound quality and for better frequency response Cable with thickness of 2 Core 1.5 Sq. mm make-LOSEN & SUNRISE
Speaker Cable 1.0 Sq. mm 80/60 Main Speakers : Cable with thickness of 2 Core 1.0 Sqmm. Use for all audio applications with Double Diamond Protection Highest quality stranded copper wire for maximum flexibility and covered with a tough PVC jacket to help prevent chafing, Wire should be designed to maximize sound quality and for better frequency response Cable with thickness of 2 Core 1.0 Sq. mm make-LOSEN & SUNRISE
Microphone Cable : Balanced shielded Roll Reel of microphone audio cable, Balanced and shielded with rope braiding to give cable substantial strength while retaining extreme flexibility & Great for building custom length mic cables, custom patch coded or other audio applications that require either a stereo or balanced signal. Make-LOSEN & SUNRISE
CENTRAL AIR CONDITIONING SYSYEM
Supply, installation, testing and commissioning of factory designed, pre-fabricated and floor-mounted, water vapour compression, scroll type water cooled chiller machine complete with semi-hermatic scroll compressors with independent refrigerant circuits, water-cooled S/T type condenser, S/T horizontal flooded type evaporator with carbon steel shell and seamless copper tubes with elastomeric insulation, common base frame, interconnected copper refrigerant piping and wiring, vibration isolators, gauge panel, automatic safety controls, flow switch at evaporator and condenser and ozone friendly, CFC-free refrigerant all complete as specified and directed.
The quoted price shall be inclusive of a unit mounted automatic star/delta starter (to ensure that the starting current does not exceed twice the full load current), variable frequency drive (VFD) configured in accordance with site parameters, victaulic coupling and system integrator capable of giving industry standard (modbus/BACnet) output to BMS for critical parameters mapping shall be required for all critical points displayed on the chiller control panel. The chiller shall be ECBC Building compliant, BMS compatible and shall have RS485/RS232 serial communication protocol; the motor shall be suitable for 3- Phase, 415 V ± 10%, 50 Hz AC electric supply; electric panel shall have an IP 54 rating.
Necessary civil work viz. foundation for placement of chillers shall be covered in the scope of work. The chiller shall be as per the approved particular technical specifications and shall meet the following design criteria:
[a] Local ambient temperature: 94.64 °F
[b] Chilled water leaving temperature: 44 ⁰F
[c] Chilled water entering temperature: 54 ⁰F
[d] Evaporator fouling factor: 0.00025 ⁰F ft²hr/Btu
[e] IKW/TR: Not exceeding 0.85
[f] Refrigerant (Ozone friendly type): R22/407C/410A
[g] Minimum COP required 4.7 (ECBC Building Compliance)
[h] Minimum IPLV: 5.8 (ECBC Building Compliance)
[h] Flow Rate: chilled water- 2.46 USgpm/TR; condenser water- 4.0 USgpm/TR
Scroll-type water-cooled chiller suitable for ambient environmental conditions having nominal capacity not less than 39 TR.
CHILLED WATER CIRCULATION PUMP (1 W + 1 S)
Supply, installation, testing and commissioning of monoblock, self-priming, single-stage, centrifugal volute type pump having cast iron casing, enclosed type dynamically balanced phosphor-bronze/SS impeller, high tensile steel shaft, carbon steel stuffing box (sealed by mechanical seal), deep groove ball bearings, TEFC squirrel cage induction motor having IE- 3 efficiency and conforming to IS: 12615- 2018, base plate, mounting channel frame, elastomeric insulation, accessories and fittings, viz. mechanical seal, pressure gauges, thermometers, drains, coupling, coupling guard, vibration isolation arrangement by means of spring / rubber type mounting suitable for operation on 3- Phase, 415 V ± 10%, 50 Hz AC supply complete all as specified and directed.
Necessary civil work viz. foundation for placement of pump, mounting of star/delta starter panel and pump accessories shall be covered in the scope of work.
Monoblock type centrifugal pump suitable for 20.80 LPS water flow and 12 MWC head along with elastomeric insulation.
FRP INDUCED DRAUGHT COOLING TOWER
Supply, installation, testing and commissioning of FRP rectanguler shape, vertical, induced draught counter flow cooling tower with uniform water distribution and optimal heat transfer, having tough fiberglass reinforced plastic (FRP) casing of sufficient structural strength to withstand vibrations and wind velocity upto 60 m/s, FRP basin, rigid honeycomb type PVC fill of suitable thickness, SS sprinklers and non-clogging sprinkler pipes, FRP drift eliminator, energy efficient induced draught axial type fans with factory set and dynamically balanced blades pitch, TEFC squirrel cage induction motor having IE- 3 efficiency and conforming to IS: 12615- 2018 with IP 65 protection, inlet, outlet, drain and over-flow nozzle connections, etc. suitable for 3- Phase, 415 ± 10% V, 50 Hz AC electric supply complete all as specified and directed.
Necessary civil work viz. foundation, supporting structure, etc. for placement of cooling tower, mounting of star/delta starter panel shall be covered in the scope of work.
FRP rectangular shape induced draught cooling tower suitable for 90 TR capacity
CONDENSER WATER PUMP (1 W + 1 S)
Supply, installation, testing and commissioning of monoblock, self-priming, single-stage, centrifugal volute type pump having cast iron casing, enclosed type dynamically balanced phosphor-bronze/SS impeller, high tensile steel shaft, carbon steel stuffing box (sealed by mechanical seal), deep groove ball bearings, TEFC squirrel cage induction motor having IE- 3 efficiency and conforming to IS: 12615- 2018, base plate, mounting channel frame, accessories and fittings, viz. mechanical seal, pressure gauges, thermometers, drains, coupling, coupling guard, vibration isolation arrangement by means of spring / rubber type mounting suitable for operation on 3- Phase, 415 V ± 10%, 50 Hz AC supply complete all as specified and directed.
Necessary civil work viz. foundation for placement of pump, mounting of star/delta starter panel and pump accessories shall be covered in the scope of work.
Monoblock type centrifugal pump suitable for 22.0 LPS water flow and 10 MWC head.
HVAC ELECTRIC PANEL
Supply, installation, commissioning and testing of factory made, CPRI type tested, outdoor, cubical compartmental type "HVAC Panel" of suitable size, conforming to IEC 61439-1 &2, IEC 61641, having both sides openable with hinged double doors & locking arrangement and IP 42 protection made out of 3.15 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete all as specified.
The HVAC Panel shall comprise of the following:
Busbar Chamber:
[i] Copper busbar of rated capacity 320 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection- 01 Set (of 04 busbars)
Incoming:
[i] 250 A, 415 V, Ics = Icu = 36 kA, conforming to IEC 60947- 2, 50 Hz, FP MCCB with adjustable overload settings, adjustable short-circuit settings, adjustabble neutral protection, adjustable earth- fault settings, instanteneous protection and microprocessor based trip unit- 01 Nos.
[ii] LED phase indicators (Red, Yellow, Blue)- 04 Set
[iii] Power Quality analyzer with revenue accuracy of Class 0.2S, complying to IEC 62053- 22, 256 samples/cycle, waveform reading, 512 MB of standard non-volatile memory for data & event logging, up to 63rd harmonics analysis for voltage & current, GPS clock, 01 serial port (Modbus, ION, DNP3), Dual Ethernet port (Modbus/TCP, ION TCP, DNP3 TCP, IEC 61850) and standard digital input, expandable digital IO, analog IO.- 01 Nos.
Outgoing:
[i] 80 A, 415 V, Ics = Icu = 25 kA, conforming to IEC 60947- 2, 50 Hz, FP MCCB with adjustable thermal settings & fixed magnetic settings with compression lug connectors and thermal magnetic trip unit (TMD)- 02 Nos. [for chillers]
[ii] 63 A, 415 V, Ics = Icu = 25 kA, conforming to IEC 60947- 2, 50 Hz, FP MCCB with adjustable thermal settings & fixed magnetic settings with compression lug connectors and thermal magnetic trip unit (TMD)- 01 Nos. [for AHU]
[iii] 32 A, 415 V, Ics = Icu = 16 kA, conforming to IEC 60947- 2, 50 Hz, FP MCCB with adjustable thermal settings & fixed magnetic settings with compression lug connectors and thermal magnetic trip unit (TMD)- 05 Nos. [2 Nos. for chilled water circulation pumps, 2 Nos. for condenser water circulation pumps and 01 Nos. for cooling tower]
[v] 32 A, 230 V, 50 Hz, SPN MCB (C- curve)- 01 Nos. [for AC Plant Room]
[iv] LED phase indicators (Red, Yellow, Blue)- 08 Set
[v] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 08 Nos.
NOTES:
[i] The panel shall be completely Ethernet communication ready to communicate with Energy Management System & shall be Web based application in-built.
[iii] The Panel shall be with wireless energy sensor on incomer and outgoing feeders for monitoring (V, I, P, PF, Energy), voltage loss alarm, Unbalance in phases. Same shall be communicated through Ethernet communication gateway to centralised Energy Monitoring System.
VARIABLE FREQUENCY DRIVE
Supply, installation, commissioning and testing of Variable Frequency Drives with IP 55 enclosures and mains disconnect switch comprising of the following:
[a] Built in dual 5% impedance DC link reactor (harmonic filters) on the positive and negative rails of the DC bus of the Variable Frequency Drive.
[b] Built in EMC filters (electro magnetic compatibility filters) for restriction of conducted emissions to comply with IEC61800:3 (un restricted distribution) :2004 Category C 1 (50 meter).
[c] Three feedback PID controller having capability to simultaneously accept 3 feedback signals from temperature sensors or pressure sensors for process optimization and accordingly control the speed of the AHUs or pumps.
[d] Integral graphical keypad.
Variable frequency drive (VFD) of power size 15.0 kW [for AHU]
AUTOMATIC STAR/DELTA STARTER
Auomatic star/delta starter for monoblock pump (for chilled water circulation pumps, condenser water pumps and cooling towers)
EXPANSION TANK FOR CHILLED WATER MAKE-UP
S & F SS- 304 closed expansion tank of pressure rating to suit the system pressure and sized adequately to compensate for water expansion due to operating temperature variations, conforming to IS: 2825- 1969 for 'non-fired pressure vessels' complete with inter-connection piping, non-return valve, safety relief valve and pressure gauge, insulated with 50 mm thick elastomeric insulation and cladded with 26 gauge aluminium complete all as specified and directed.
SS- 304 closed expansion tank of 100 litres capacity
HDPE MAKE-UP WATER TANK FOR COOLING TOWER
S & F multilayered HDPE storage tank made up of 100% virgin material, having 100% UV stabilized white outer layer, threaded lid, extra insert lid for protection against algae formation complete with inter-connection piping and non-return valve etc. complete all as specified and directed.
HDPE make-up water tank of 5000 litre capacity
CONDENSER WATER PIPING
MS ERW CLASS- C PIPE
Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS ‘C’ class along with necessary clamps, vibration isolators and fittings such as bends,tees etc., but excluding valves, strainers, gauges etc., adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. complete as specified.
BUTTERFLY VALVE
Supply, installation, testing and commissioning of PN 1.6 rated double flanged short & long body type butterfly valve designed, manufactured and tested as per IS 13095: 1991, suitable for isolation and throttling services, having CI body & disc, SS AISI 304 disc seal, CS clamping ring and SS AISI 410 shaft and flange drilling standard end connection with accessories complete all as specified and directed.
NON-RETURN VALVE (NRV)
Supply, installation, testing and commissioning of PN 1.6 rated swing check type multidoor reflux valve (NRV), designed & tested as per IS 5312 (Part- 2): 1986, suitable to handle clear water having turbidity up to 5000 PPM, having CI body, door and diaphram, leaded tin bronze seat rings and flange drilling standard end connection, etc. with accessories complete all as specified and directed.
Y-STRAINER
Supply, installation, testing & commissioning of Y-type strainer with CI / MS body, bolted cover, flanged ends, basket of brass / bronze / SS wire mesh complete with flanges, nuts-bolts, gaskets and flange drilling standard end connection, etc. complete all as specified and directed.
MANUAL BALANCING VALVE
Supply, installation, testing & commissioning of manual balancing valve suitable for PN 1.6 pressure rating, having built-in measuring facility, with CI body, flanged connection, EPDM coated disc with long pitch, etc. conforming to BS 7350 for condenser water circulation complete all as specified.
CHILLED WATER PIPING
MS ERW CLASS- C PIPE WITH INSULATION
Supplying, laying / fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with duly insulated with closed cell elastometric nitrile rubber of minimum 45 kg/m³ density, thermal conductivity 0.037 W/mK or better at 20 ⁰C mean temperature class ‘O’ insulation applied by suitable rubber based adhesive covered with a layer of 120 g/m² polythene sheet (vapour barrier) and finally applying 0.63 mm aluminium sheet cladding complete as specified.
Y-STRAINER
Supply, installation, testing & commissioning of Y-type strainer with CI / MS body, bolted cover, flanged ends, basket of brass/ bronze / SS wire mesh complete with flanges, nuts-bolts, gaskets and flange drilling standard end connection duly insulated with closed cell elastometric nitrile rubber of minimum 45 kg/m³ density, thermal conductivity 0.037 W/mK or better at 20 ⁰C mean temperature class ‘O’ insulation applied by suitable rubber based adhesive covered with a layer of 120 g/m² polythene sheet (vapour barrier) and finally applying 0.63 mm aluminium sheet cladding and accessories complete all as specified and directed.
BUTTERFLY VALVE
Supply, installation, testing and commissioning of PN 1.6 rated double flanged short & long body type butterfly valve designed, manufactured and tested as per IS 13095: 1991, suitable for isolation and throttling services, having CI body & disc, SS AISI 304 disc seal, CS clamping ring and SS AISI 410 shaft and flange drilling standard end connection duly insulated with closed cell elastometric nitrile rubber of minimum 45 kg/m³ density, thermal conductivity 0.037 W/mK or better at 20 ⁰C mean temperature class ‘O’ insulation applied by suitable rubber based adhesive covered with a layer of 120 g/m² polythene sheet (vapour barrier) and finally applying 0.63 mm aluminium sheet cladding and accessories complete all as specified and directed.
NON-RETURN VALVE (NRV)
Supply, installation, testing and commissioning of PN 1.6 rated swing check type multidoor reflux valve (NRV), designed & tested as per IS 5312 (Part- 2): 1986, suitable to handle clear water having turbidity up to 5000 PPM, having CI body, door and diaphram, leaded tin bronze seat rings and flange drilling standard end connection, etc. duly insulated with closed cell elastometric nitrile rubber of minimum 45 kg/m³ density, thermal conductivity 0.037 W/mK or better at 20 ⁰C mean temperature class ‘O’ insulation applied by suitable rubber based adhesive covered with a layer of 120 g/m² polythene sheet (vapour barrier) and finally applying 0.63 mm aluminium sheet cladding and accessories complete all as specified and directed.
MANUAL BALANCING VALVE
Supply, installation, testing & commissioning of manual balancing valve suitable for PN 1.6 pressure rating, having built-in measuring facility, with brass / CI body, flanged connection, EPDM coated disc with long pitch, etc. conforming to BS 7350 for condenser water circulation duly insulated with closed cell elastometric nitrile rubber of minimum 45 kg/m³ density, thermal conductivity 0.037 W/mK or better at 20 ⁰C mean temperature class ‘O’ insulation applied by suitable rubber based adhesive covered with a layer of 120 g/m² polythene sheet (vapour barrier) and finally applying 0.63 mm aluminium sheet cladding and accessories complete all as specified and directed.
3-WAY TEMPERATURE CONTROL VALVE
Supply, installation, testing and commissioning of electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 3-way modualating control valves in a single body duly insulated with closed cell elastometric nitrile rubber of minimum 45 kg/m³ density, thermal conductivity 0.037 W/mK or better at 20 ⁰C mean temperature class ‘O’ insulation applied by suitable rubber based adhesive covered with a layer of 120 g/m² polythene sheet (vapour barrier) and finally applying 0.63 mm aluminium sheet cladding and accessories complete all as specified and directed.
[i] The actuator shall be capable of accepting upto 10V DC and upto 20 mA electric signal and shall provide similar transduced feedback output to control system.
[ii] Maximum close off pressure shall not be less than 6 bar for upto 50 mm valves and not be less than 7 bar for 65 mm & above.
[iii] Valves should have pressure rating of 25 bar minimum.
DRAIN PIPE
M & L for UPVC pipes and fittings, resistant to chemical & electromechanical corrosion, conforming to EN 1452-2, having specific gravity 1.43, shore hardness 70 °C to 90 °C, tensile strength 500 kg/cm², bending strength 950 kg/cm², modulus of elasticity 3.2 X 10 kg/cm² and dielectric strength > 40 kV/mm complete with accessories complete all as specified and directed.
BALL VALVE
S & F of CL 150 # rated ball valve, designed & manufactured as per IS: 9890 (1981) and tested as per BS 6755 Part- I, having floating type three piece design, CS body, SS- 304 ball, PTFE seal/packing/gasket, CS fastners and lever and screwed/socket weld end connection, etc. with accessories complete all as specified and directed.
AUTO-AIR-VENT
Supply, installation, testing and commissioning of automatic air-vent valve with Brass OT 58 body and cover, polyacetal lever, high density expanded polyethylene float, EPDM rubber plug, stainless steel spring, polyamide cap etc. suitable for maximum operating pressure of 16 bar and maximum operating temperature 115 °C respectively, installed on all high points in the water piping system to automatically remove the trapped air complete all as specified and directed.
Automatic air-vent having 20 mm end connections
TEMPERATURE GAUGE
Supply, installation, testing and commissioning of glycerin filled bimetallic thermometer in compliance to EN 13190, having standard range 0 °C to 60 °C up to 400 °C, IP 67 protection, bimetal coil sensing element, accuracy class 1 as per EN 13190, stainless steel casing, direct bottom mounted, SS- 304 case and bayonet type bezel, SS- 316 stem and connection, aluminum dial (white background with black marking) & pointer (black colour micrometer with zero adjustable), toughened glass window, neoprene filling plug and gasket complete with accessories, etc. complete all as specified and directed.
Temperature gauge of 150 mm dial size for temperature range 0° C to 100° C
PRESSURE GAUGE
Supply, installation, testing and commissioning of glycerin filled pressure gauge in compliance to EN837-1, having standard range 15 to 0 psi and 16 psi to 10000 psi, IP 67 protection, accuracy class ±1.6% of FS, stainless steel casing and TIG argon welded socket to case, direct bottom mounted, SS- 304 case and bayonet type bezel, SS- 316 bourdon, socket, SS dial (white background with black marking) & pointer (black colour micrometer with zero adjustable), polycarbonate glass window, neoprene blow off disc and filling plug, silicon gasket complete with accessories, etc. complete all as specified and directed.
Pressure gauge of 100 mm dial size for pressure range 0 psi to 200 psi
AIR DISTRIBUTION
DOUBLE SKIN AIR HANDLING UNIT
Supply, installation, testing and commissioning of double-skin type horizontal, floor-mounted, top/side discharge air handling units having corrosion resistant extruded aluminum hollow profile with thermal break, 16 gauge galvanized steel channel base frame, 43 mm thick double skin panel with pressure injected CFC & HCFC free PUF having 'k' value of 0.02 W/°C/m & density 40 kg/m³ pre-coated, pre-plasticized, galvanized outer and inner skin 0.60 mm thick, air-tight casing using gaskets and self-adhesive tapes, AMCA certified energy efficient fans with double inlet, double width forward or backward curved impellers for high static pressure mounted on aluminum extruded siderail base frame, combination of 6 rows deep chilled water coils with anti-corrosion aluminum fins, combination of 2 rows deep hot water coils with anti-corrosion aluminum fins PVC/naylon hinges & handles, view port and marine lamp, limit switch, SS-304 drain pan, 10 micron pre-filters, inspection windows/doors, mixing box and supply/return/fresh air dampers complete all as specified and directed.
The AHU shall comprise of the following:
[a] Suitable DIDW fan with AMCA certified blower having outlet velocity not exceeding 9.2 m/s
[b] 4 Pole, TEFC, high efficiency IE2 , squirrel cage induction motor having BHP rating 20% higher than the peak capacity, suitable for 415 V ±10%, 50 Hz, 3-Phase AC power supply
[c] V-belt drive assembly with pulleys, belt, guard, etc., double canvass connections with zip to discharge duct/plenum, etc.
[d] 50 mm thick, washable HDPE, 90% down 10 micron pre-filters, filters, fixing framework, hinge type access doors, etc.
[e] 6 row deep chilled water coil section with copper fins and copper tube tested on 21 kg/cm² with SS sandwiched drain tray, etc.
[f] AHU panel made out of 2.00 mm thick mild steel CRCA sheet, duly powder coated, in compartamentalised construction with incomer and outgoing feeders for AHU motor, 3-way valve actuator motor, fire damper actuator motor, etc. complete with required variable frequency drive (VFD), relays, timers, contactors, PT, push buttons, switches, internal wiring, etc.
Necessary civil work viz. foundation for placement of AHU, mounting of variable frequency drive (VFD) panel, construction of opening(s) for fresh/exhaust air etc. shall be covered in the scope of work.
26000 CFM; 60 mm WG static pressure
GALVANIZED STEEL SHEET DUCTING
Supply, installation, testing and commissioning of factory fabricated, galvanized steel sheet (G.S.S.) square / rectangular ducting for supply / return air, fabricated from galvanized steel sheet, having zinc coating of 160 g/m² total on both sides complete with gaskets, elbows, splitters, vanes, motorized volume control dampers, supports etc. conforming to per IS 655: 2006 along with required scaffolding work to install the ducts at site complete all as specified and directed.
24 G (MS angle flanges)
22 G (MS angle flanges)
20 G (MS angle flanges)
18 G (MS angle flanges)
FIRE DAMPER
Supply, installation, testing and commissioning of fire damper complete with smoke detector/thermister, fusible link etc. and actuator as required for operation. The fire dampers shall be spring activated on melting of fusible link having melting point 67.13° C. The fire damper shall be located in the SA/RA ducts, at all fire rated crossoevers (shafts, walls, etc.). The control panel shall be located in such a way that the reset can easily be done. These combination smoke and fire dampers shall be interlocked with the building management system for the fire detection or HVAC and shall trip/close in the event of fire/smoke in the respective zone. Fire damper shall be tested as per ULL- 555 and certified by CBRI. The fire-damper shall be of at least 120 minutes fire-rating complete all as specified and directed.
The fire dampers shall meet the following criteria:
[a] Bare fire dampers with 400 mm sleeve
[b] Control panel actuator, including electrical spring type actuator, remote indication of the fire damper position.
[c] Interconnection wire for the fire detection & alarm system with the AHU and the smoke dampers
[d] Sealing any openings around the sleeve of the fire dampers with approved fire sealant as per the specification & recommandations of the manufacturer.
Motorized, spring return type, combination fire and smoke damper
Control panel actuator, including electrical spring type actuator, remote indication of the fire damper position.
THERMAL INSULATION
S & F closed cell elastomeric nitrile rubber insulation with aluminum foil laminated on one side, having thermal conductivity not exceeding 0.037 W/mK at mean temperature of 20° C as per EN 12667, moisture diffusion resistance factor or ‘µ’ value of minimum 7,000 for base insulation material without the foil as per EN 12086, fire performance such that it passes Class 1 as per BS476 Part 7 for surface spread of flame and also fire performance of V0, HB as per UL 94, 1996, density without the foil between 40 to 55 kg/m³. The insulation material shall be FM (Factory Mutual) USA approved and dust & fibre free. The Aluminium foil shall be 60 microns thick and its weight shall be 193 gsm as per EN ISO 2286-2, tensile strength 90 N / 15 mm as per EN ISO 527-3 with elongation > 10% as per EN ISO 527-3 complete all as specified and directed.
19 mm thick nitrile rubber thermal insulation
13 mm thick nitrile rubber thermal insulation
ACOUSTIC INSULATION
S & F open-cell engineered nitrile rubber foam acoustic insulation having good sound absorption, damping and barrier properties, antimicrobial product protection, thermal conductivity not exceeding 0.047 W/mK at 20° C, conforming to EN 12667, density 140-180 kg/m³ and conforming to class 1 rating for surface spread of flame in accordance with BS 476 Part 7 & UL 94 (HB, V-0). The acoustic insulation material shall be free of dust and fibre; it shall pass fungi/mould resistance as per DIN EN ISO 846 method A and bacterial resistance as per DIN EN ISO 846 method C and air erosion resistance test in accordance to ASTM Standard C 1071-05 without any laminate or covering (section 12.7) from an independent accredited testing agency complete all as specified and directed.
19 mm thick nitrile rubber foam acoustic insulation
13 mm thick nitrile rubber foam acoustic insulation
SA/RA DIFFUSERS/GRILLES/LOUVERS
Supply, installation, testing & commissioning of removable supply/return air diffusers/grilles or eye ball jet diffusers of extruded aluminum sections duly powder coated with volume control damper complete all as specified and directed.
ELECTRICAL WORKS
POWER CABLES
M & L for ISI marked 1.1 kV grade aluminium conductor, XLPE insulated armoured cables, conforming to IS: 7098 (Part 1)- 1988 having stranded aluminium compact shaped conductor as per Cl. 2, IS: 8130- 1984, PVC inner sheath, single armouring of galvanized steel strip/wire and PVC Type ST- 2 outer sheath conforming to IS: 5831- 1984, including termination complete as specified and directed.
4 core, 16 mm²
3.5 core, 25 mm²
3.5 core, 70 mm²
M & L for earth contuinity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20 mm X 3 mm copper strip complete all as specified and directed.
M & L for earth contuinity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required GI wire of 4.0 mm diameter complete all as specified and directed.
M & L for earthing complete with copper earth plate electrode of 60 cm x 60 cm x 3.15 mm size, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to copper strip of size 20 mm x 3 mm as earth lead, by means of bolts, buts, check nuts and washers of galvanised iron or steel, galvanized iron pipe of 40 mm diameter, connected to earthing test point, all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion and including excavation, earthwork, PCC earth pit of dimensions 550 mm X 550 mm (outer) and 300 mm X 300 mm (inner) and 250 mm deep, with a 10 mm thick CI cover, hinged to CI frame on ground level, GI watering pipe, funnel, etc. as all specified and directed.
Comprehensive Maintenance of AC Plant
Comprehensive maintenance comprising of routine, preventive & breakdown maintenance of chilled water type central air conditioning plant of capacity 2 x 30 TR installed, comprising of all devices and accessories through out 12 months on all days including sundays & holidays for a period of 03 years after expiry of defects liability period (i.e. 24 months after completion of all Phase II tests) all as specified and directed and as shown below: at Auditorium Karwar
(a) 1st year after expiry of defect liability period.
(b) 2nd year after completion of work 26.02 mentioned above
(c) 3rd year after after completion of work 26.03 mentioned above
Services for Manning & Operation of AC Plant
Outsourcing of services for 2 shifts ( consisting of two shifts) including Sundays and holidays and operation of Central type air conditioning plant of capacity 2x30 TR ( Two plants each to be run at a time and one will be kept as stand by) including all connected electrical items such as main switch, starter,change over switch, MCCB, voltmeter, ammeter, panel board etc, cooling tower,condenser or water pump ,valve system,controling system, condenser,refrigerant line,adjusting valve, refrigrant valve, bypass valve, daily checcking, leakage, checking noise, controlling temp. of plant,cleaning of plant and it's surrounding area etc, by one Ref Mech (Skilled) per shift for 02 shifts in a day all as per manufacturers instructions and as specified and directed by Engr-in-charge.
(a) 1st year after completion of work and taking over site by users whichever is later
(b) 2nd year after completion of work 27.02 mentioned above
(c) 3rd year after after completion of work 27.03 mentioned above
(d) 4th year after after completion of work 27.04 mentioned above
(e) 5 th year after after completion of work 27.05 mentioned above
(f) 6 th year after after completion of work 27.06 mentioned above
NOTES:- (a) The contractor shall be responsible for periodical/routine maintenance, as per maintenance schedule recommended by manufactur/OEM, including renewal / replacement of parts, fittings / fixtures filling of refrigerant gas etc required for smooth functioning of the plant as per manufacturers instructions.The cost of all parts/componant/Gas required for replacement are considered inclusive in quoted rate (b) The Contractor shall Employ Refrigeration mechanic having minimum ITI qualification from Govt Recognised institute with adequate knowledge & minimum 2 years experience in maint/operation of AC plants. The operator must competent to carry out the minor maint all as directed. (TOTAL number of operators required per day are 02 nos.) (c) Contractor shall pay the wages to the employees through e-payment i.e Adhaar linked bank accounts (credit to their bank account). Engineer-in-charge shall ensure that e-payment made to employees and their wages shall not be less than minimum wages fixed by state Govt or Central Govt whichever is more. Monthly e-banking statement shall be furnished by the contractor to the Engr-in-charge and the same shall be kept in record duly verified.
(d) It is the responsibility of contractor to deposit the employees provident fund (EPF) to the concerned authority as per the prevailing scales as laid down by Ministry of labour for all operator/helper (as appliable) and necessary proof to this regard shall be submitted to the Engineer-in-charge for verification & record. The quoted rates shall be deemed to be included of above provisions. In case contractor fails to produce the proof of EPF, the same shall be recovered from his dues as per the prevailing scale plus 15 percent. (e) The contractor shall maintain all the registers under various labour law rules, 2017 and shall be produced to the Engineer-in-Charge as well as officers detailed by central labour department. (f) Each shift duration shall be 8 hours & duty timing will be decided by Engr-in-Charge. (g) The unit rate quoted shall deemed to be included for cost of labour for daily routine maintenance for trouble free functioning of installation. (h) In case of any abnormal noise/ complaint the plant should be put off and same should be brought to the notice of Engr-in-charge. (i) The operator employed by the contractor shall be capable of carrying out minor repair/ maintenance & should have well experience in AC plants as applicable. (j) The quoted rate is deemed to be inclusive of cotton waste, cleaning material etc & Contractor will ensure general area cleanliness and upkeep of the installation on daily basis.
(k) The quoted rate is deemed to be inclusive of tools & testing instruments required for operation & maintenance of AC plants. (l) The rate quoted shall deemed to be inclusive of safety gear & required tools for minor maintenance. In case of failure to provide tools kit & safety kit (spanner sets, hand gloves), a penalty of Rs 3000/- will be recovered and levied (m) The Contractor shall not employ same tradesman continuously for more than 11 months during the Contract period. (n) The contractor shall provide 02 uniforms to each operator and design of uniform shall be got approved. In case of failure, a penalty of Rs 2000/- per uniform will be levied and recovered from their dues. (o) In case of failure due to absence of operative staff, the contractor shall be liable to pay compensation at twice the cost of a day’s Manning & Operation derived from pro rate of Sch ‘A’ quoted rates. (p) The Contractor shall maintain proper records of all kinds of daily, weekly, monthly, quarterly, half yearly and yearly or whatsoever maintenance is carried out during contract period in a binded book / register and shall obtain the signature of Engineer-in-Charge every fortnightly.
(q) The contractor shall provide board at proper location near each installations duly writting the name of operators and Mobile Numbers shiftwise. (r ) In case of non function of AC Plant panel recovery @ 3000 per day shall be effected 24 hrs after the defect is noticed or notified either in writing or through a social media message by GE or his rep. (s) Any defect in to a motor , Pumps, compressure ,Control Panel ,AHU, Refrigarent Gas , Cooling Tower shall be considered as outstanding defect & Panel charge will be applicable as above in para (r ) above
M/s Gujarat Construction Company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .