Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.2 LAccepted-AOC MIG 2B 65 VINAYAKA NAGAR VUDA COLONY VISAKHAPATNAM 530044 | VISAKHAPATANAM | ANDHRA PRADESH | 530044 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹26.3 L+₹1.4 L (5.47%)Rejected-Finance D NO LIG 98 RAJEEV NAGAR KURMANNAPALEM VISAKHAPATNAM 530 048 | VISAKHAPATANAM | ANDHRA PRADESH | 530048 | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹27.1 L+₹2.2 L (8.78%)Rejected-Finance | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹34.0 L+₹9.1 L (36.6%)Rejected-Finance | L4 | Rejected-Finance Being not L1 | |
| 5 | L5₹36.3 L+₹11.4 L (45.8%)Rejected-Finance | L5 | Rejected-Finance Being not L1 |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
10 Sept 2022, 6:00 pmClosed
Garrison Engineer Utility-I
Garrison Engineer Utility-I Near Samudrika Naval Base Post Visakhapatnam -530 014
REPAIR/MAINT OF HT DISTRIBUTION SYSTEM, UG CABLES, DISTRIBUTION TRANSFORMERS, RMUS, VCBS AND REPAIR/MAINT OF LT PANELS, UG CABLE, STREET/HIGH MAST LIGHT AND GARDEN LIGHTS AND CERTAIN ALLIED WORKS AT INHS KAYANI UNDER AGE E/M NO. I OF GE (U-I)VSKP
2022_MES_545308_1
8453/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Garrison Engineer Utility-I Visakhapatnam
CLASS D
8 documents required · 8 mandatory
₹500
Garrison Engineer Utility-I
₹88,000
Yes
19 Sept 2022
13 Aug 2022
12 Sept 2022
13 Aug 2022
10 Sept 2022
29 Aug 2022
Amount
Dismantling the spring charging mechanism of the VCB, checking the entire mechanism for any worn/ crack/ bent/ block/ loose parts etc. for the following :- (i) Checking the condition of the spring charging motor along with gear box including servicing the motor & replacement of motor bearings if required. (ii) Checking/ servicing of ratchet wheel assembly, driving and charging parts.
(iii) Checking the auxiliary switch, its contacts for proper functional operation. (iv) Checking & servicing of raising/ lowering mechanism and its locking system for proper functioning. (v) Checking & servicing of shutter assembly for its automatic opening/ closing.
Note:- The items like nuts, bolts, spring washers, petroleum jelly, CTC etc required to put the breaker in serviceable condition shall be supplied by the contractor and rate shall be deemed to be included in the unit rate quoted.
M&L for de-carbonising/ cleaning of 11 KV cubicle type VCB panels consisting of bus bar and circuit chamber, metering chamber, CTs, PTs and relay chamber all as specified below :- (i) Checking the bus bar and circuit spouts, cleaning with CTC and applying bectrol red varnish to the surface of the bus bar and circuit spouts. (ii) Checking the CTs/ PTs for any arcing/ tracks, cleaning and applying one coat of varnish.
(iii) Cleaning of metering and relay chamber, checking/ replacement of burnt wires if any, tightening of all connections to arrest the loose contacts. (iv) Applying mono-plast compound at bus bar joints after tightening all joints/ connections.
M&L for Disconnecting IED of any type and Make from 11 KV HT panel, cleaning the contacts , IED configuration , Calibration & Testing of all the measuring & protection devices viz., CTs, Relays and Meters at site. Testing of all the trip functions of the relays after final current settings by simulating fault current by CT secondary injection test set , checking of current transformer , rectification of defects in control wiring for proper tripping of CB during actual system fault conduction through relay & Tripping coil. Adjustment / setting to plug and time multiplier settings of IED to achieve the discrimination in tripping , tune / synchronies upstream breaker relay settings-installation of relay, testing & commissioning etc complete all as specified and as directed.
Supply and replace of CT's epoxy cast resin , with primary Current 100A - 50A / 1 A - 1A , Secondary current 1A , Dual core , Dual Ratio. Protection core -Class 5P10 & Metering core - Class 0.5 , 2.5 VA, Suitable for Siemens Make RMU all as directed.
Supply and replace following spares :
LED Indication Lamps Make : L&T, GE, Siemens, ABB / C&S
LED type push button actuators Make : L&T, GE, Siemens, ABB / C&S
Shunt trip coil 110 V DC / 220 V DC Make : L&T, GE, Siemens, ABB / C&S
Breaker Control Switch Make : L&T, GE, Siemens, ABB / C&S
Control Circuit fuses 2A to 63A Make : L&T, GE, Siemens, ABB / C&S
HRC fuses for PT primary side Make : L&T, GE, Siemens, ABB / C&S
Ammeter 240 deg 144 sq. mm Make : L&T / Havells / HPL / AE / Schneider
Voltmeter 240 deg 144 sq. mm Make : L&T / Havells / HPL / AE / Schneider
Multi function meter , Digital type (Displaying A, V, PF, Hz, KVA, KW, KVAR, KWh, Karsh etc) class 1/.5 with RS485 port for communication in Modbus protocol. Make : L&T / Havells / HPL / AE / Schneider
Panel Space Heater 2 KW rating
Digital Temperature Indicator along with thermostat. Make : L&T / Havells / HPL / AE / Schneider
Bus bar Support DMC insulator for VCB panel
Vacuum interrupter Type VG2
Spring Charging motor with gear box universal motor with gear box 230 AC/DC 110 V AC/DC.
Ratchet wheel
1250 A finger type isolating tulip contacts.
Supply and lay Control Wiring inside Control Chamber of 11 KV VCB with 1 Core , 2.5Sq mm Copper wire with proper ferules & appropriate Lugs complete all as specified and directed.
Supply and fix Bus bar Spout
Supply & replace 11 KV potential transformer TYPE VIR= 11000/RT3/110/RT3/110/RT3V, VA=100/50 VF; 1.2CONT&1.9 for 8 Hours, voltage transformer single phase type HSV/IL, 12/28/75 KV all as specified
Supply & replacement, calibrating, testing, commissioning of Micro processor feeder protection relay, range - 0.01In – 8In, protection setting- 2 set, protecting circuit correct – 1 Amps & 5 Amps sets, records history- 5Nos, min 6 Analog out put, with protections viz. feeder protection 50/ 51N (3 Phase current), 50/ 51N (Earth Over current), 67 P (3 Phase directional Over current), 6/N (Earth fault directional over current), 51V (Voltage controlled over current) 37 (3 phase under current), 46(Negative phase sequence over current), 59N (Residual over voltage), 49 (Thermal over load), 79(Auto reclose), 50BF( Circuit breaker failure detection), Cold Load pickup, Inrush blocking, Relay will be on MODBUS protocol with LCD display, trip, circuit healthy, alarm, other assignable indication,Auxlary suppy : 110V DC complete all as specified and directed.
Supply and laying or fixing or passing through pipe or in cable ducts, 11000 volts grade XLPE(FRLS) insulated Heavy duty (earthed), screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor 185 sqmm 3 core size including dismantling old one complete all as specified and directed by Engineer-in-Charge. MAKE: Havells / Gloster / KEI Industries Ltd / Polycab / Asian Cables / Finolex
Supply and fix of Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 sqmm complete all as specified. Make: M-Seal/ 3M/ Raychem/ Denson
Supply and fix cable jointing kit for 11 KV grade cable for outdoor terimination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conducter cable of size 185 sq mm complete all as specified. Make: M-Seal/ 3M/ Raychem/ Denson
Supply and fix cable jointing kit for 11 KV grade cable for indoor terimination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conducter cable of size 185 sq mm complete all as specified. Make: M-Seal/ 3M/ Raychem/ Denson Note for sl item No. 11.00 to 13.00 : Excavation , removal, Returning filling etc shall be measured and paid separatly.
M&L for disconnecting carefully electrical connection from both HT/ LT (primary & secondary) sides of the transformer, keeping them at safe side the transformer indoor/ outdoor type of capacity from 63 KVA to 1000 KVA , 11 KV/ 0.433 KV, step down any make for carrying out refixing after completion of minor repairs like maintenance / replacement of HT/LT bush, metal rods, lugs, replacement of rusted nutbolts etc incl cheking the continuty of HT/LT windings , top cover opening, prevent the all oil leakages, provn of new insulated gaskets / cork sheet for HT/LT supply etc complete all as specefied and directed. Note: Porcelain bushings, gun metal rods, cable end joint kit, transformer oil etc shall be measured and paid separatly.
Decarbunizing / cleaning complete LT 415 Volts 3 phase panel / bus bar chamber with electrical connections, complete bus bar from the bus bar chamber, cleaning with CTC and ensure proper decarburizing, refixing the same after applying Backtol Red solution to the bus bar insulator & checking all the connections, tightening the nuts, bolts & thimbles of in-coming/out-going system complete incl replacement of defective rusted bolts & nuts all as specified and directed.
Supply and replace MCCB 4 pole, 415 V, adjustable type 400 Amps with breaking capacity 35 KA including necessary modification in the panel with proper lugs complete all as specified and as directed. Make: L&T/Seimens/Schneider/Legrand/indoasian
Supply and replace MCCB 3 pole, 415 V, adjustable type 250 Amps with breaking capacity 35 KA including necessary modification in the panel with proper lugs complete all as specified and as directed. Make: L&T/Seimens/Schneider/Legrand/indoasian
Supply and replace MCCB 3 pole, 415 V, adjustable type 200 Amps with breaking capacity 35 KA including necessary modification in the panel with proper lugs complete all as specified and as directed. Make: L&T/Seimens/Schneider/Legrand/indoasian
Supply and replace MCCB 3 pole, 415 V, fixed type upto 63 to 100 Amps with breaking capacity 16 KA including necessary modification in the panel with proper lugs complete all as specified and as directed. Make: L&T/Seimens/Schneider/Legrand/indoasian
M&L for removing the cable connections of four pole/ three pole Air circuit breaker of capacity 400 to 1600 Amps ,415 V 50 HZ of make L&T /C&S/GE/ABB , strip opening the Air circuit breaker, inspecting the parts for serviceability / overhauling complete and carrying out the following repairs/maintenance :- a) Cleaning the insulation parts including bushings with CTC solution. b) Checking the alignment and condition of movable and stationary contacts and adjust them all as per manufacturer's instructional manual. c) Check the bolts, nuts, washers, cotter pins and all terminal connections are in place and tights. Replace the worn-out parts. d) Check arc chutes for damage and replace damaged parts.
e) Clean and lubricate the operating mechanism with a light machine oil (SAE-20 or 30) for pins and bearings and with a non-hardening grease for the wearing surfaces . Adjust breaker operating mechanism all as per manufacturer's instructional manual . Replace if there is excessive wear and tear. f) Checking / inspecting shunt trip coil for serviceability and replacing the same if required. g) Replacing the badly worn or burned contacts. Checking control device free for operation. h) Check after servicing the circuit breaker to verify the contacts move to the fully opened and fully closed positions, that there is an absence of friction and that the electrical operation is functional. Note : (i) The rate quoted deemed to be inclusive of T&P and minor spares like lubricants, nuts/bolts/washers/ pins etc. (ii) Major spares like contacts, shunt trip coil , relays, CTs etc shall be measured & paid separately.
S&F under voltage / trip/closing contact coil / auxiliary contact block suitable for air circuit breakers of rating 400 to 1600 Amps rated all as specified and directed. Make: L&T/C&S/ GE/ABB/Siemens/Schneider
S&F Arc chutes (for 415 V) suitable for air circuit breakers of rating 400 to 1600 Amps rated all as specified and directed. Make: L&T/C&S/ GE/ABB/Siemens/Schneider
S&F shunt release (110 /220 V DC or 240 V/415 V AC) suitable for air circuit breakers of rating 400 to 1600 Amps rated all as specified and directed. Make: L&T /C&S / GE / ABB / Siemens / Schneider
S&Farcing contacts (fixed/ moving) suitable for air circuit breakers of rating 400 to 1600 Amps rated all as specified and directed. Make: L&T /C&S / GE / ABB / Siemens / Schneider
Supply & Fix in repairs street light luminaire integral type high power LED light fitting of 90 watts output in aluminium die cast housing with IP 66 protection complete with all accessories including driver and electronic surge protection device of 5 KV complete all as specified and as directed. (MAKE : Havells / Bajaj / Philips / Wipro / GE / CG / Goldmedal ).
Preparation of external surfaces of LT panels indoor/outdoor type by scraping down old paint using steel brush broomming rubbing and cleaning applying two coats of synthetic enamel paint of approved tint and marking feeder details complete all as directed by Engineer-in-Charge.
Preparation of external surfaces of Two bed Mortury cabinet units indor type by scraping down old paint using steel brush broomming rubbing and cleaning applying two coats of synthetic enamel paint of approved tint and marking reuired details complete all as directed by Engineer-in-Charge.
Taking down defective street light fitting of any size /any type/ any capacity from height of pole/ walls/ high rise of any location of poles of 09 Mtr / 11 mtr height from ground level for reapir work and fixing back after repair work is carried out including checking, inspecting, testing and commissioning complete all as directed by Engr-in-Charge. Note : (a) Spares like ballast, lamp, starter, capacitor , igniter, holders, lamp holder, etc. shall be measured and paid separetely as supply only. (b) Necessary required T&P Viz. Mobile ladder etc shall be arranged by the contractor. (c) The rate quoted deemed to be inclusive for minor repair parts like nuts, bolts,cirle clips, clamps etc if required at site.
Supply only the following spares of street light fittings: (Make : Phillips/ crompton Greaves / Havells / GE )
LED driver of 45/60 watt all as direted by Engr-in charge
LED driver of 90/120 watt all as direted by Engr-in charge
Supply and fixing Flood light die cast aluminium of 150 W, 230 volts with IP 66 including driver with all fixing arrangements viz nuts & bolts, clamps, iron chanels on poles etc complete all as specified and directed by Engineer-in-Charge including taking out old one of any type complete all as specefied and directed. (MAKE : Havells / Bajaj / Philips / Wipro / GE / CG / Goldmedal)
Supplying, fixing and testing of Gate/ Post top LED light fitting 40 W with die cast aluminium body with driver, 230 volts and with spun aluminium landscape luminaire and IP-65 protection with high power LED as source including all necessary fixing arrangments etc including taking out old one of any type complete all as specefied and directed. (MAKE : Havells / Bajaj / Philips / Wipro / GE / CG / Goldmedal)
M&L for preperation of old painted surface, cleaninig of oils, lubricants, grease etc complete of any type of 9.0 m long poles as per IS above PCC coping and applying Two coats of aluminium paint including brackets, clamps and terminal boxes including 5 cm wide two nos red colour flourcent strip pasting on pole as directed and writing pole Nos complete all as specefied and directed.
Excavating in trenches n. exc. 1.5m wide and n. exc. 1.5m in depth for foundation, trenches for laying poles/ cables/ pipe line etc. and getting out in soft/loose soil complete all as specified and directed.
Removing excavated materials to a distance n. exc. 50 m and depositing where directed at a level n. exc 1.50 m above the starting point complete all as specified and directed.
Returning, filling in including spreading leveling watering and well ramming in layers not exc 25 cm in any type of soil complete all as specified and directed.
Supply and spreading clean dry sand for cable cushioning in trenches complete all as specified and as directed. (Note: Punned thickness only shall be measured)
Supply and laying sub class 'B' bricks of old size (23x11x7cm) laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge
Supplying, laying, testing and commissioning LT XLPE insulated , armoured heavy duty electric cable of 4 core 16 sqmm, 1100 volts grade with stranded aluminium conductor laid in trenches / passing through pipe / duct/ road crossing /fixed on poles / walls Complete all as specified and directed. MAKE: Havells / Gloster / KEI Industries Ltd / Polycab / Asian Cables / Finolex [Note: The rate quoted shall inclusive of termination at ends with suitable aluminium lugs where required]
All as per item No.38 here-in- before but of 3.5 core 50 Sqmm.
All as per item No.38 here-in- before but of 3.5 core 95 Sqmm.
All as per item No.38 here-in- before but of 3.5 core 120 Sqmm.
All as per item No.38 here-in- before but of 185 sqmm 3.5 core.
Supply and fix hot press moulded junction boxes with hinged door, fitted with 4 P, 50 Amps rated connector and neutral link mounted in the box, including necessary fixing arrangement to the steel tubular pole/over walls including taking out old one complete all as specified and directed. Make : Sintex / Hansel Controls / National
Supply and replacement of multi core PVC insulated stranded copper conductor of size 1.5 sqmm 3 core cable to be connected with street light fittings to loop-in and out boxes with its end point terminal connection all as specified and directed. Make : Polycab /Finolex / Havells
Supplying , fixing and testing of timer switch 65 A 3 pole panel complete for street light controls analog timer switch with connected items fixing on pole/wall/panels including PCC with all fixing arrangements complete including taking out old one etc all as directed. Make: Havells/ Indo Asian / L&T / Siemens /Hager / Schneider.
M & L for grass cutting, removing shrubs and area cleaning of sub station yard at INHS Kalyani complete all as direted
Material and labour for maintenance to 400 KVA Gen Set for 'B' check after 06 months or 250 hrs running, whichever is earlier as per the recommendations of manufacturer including renewing of necessary filters, Engine oil etc, complete all as per manufacturers instructional manual and all as directed by Engg-in-charge. Note : Engine oil shall be suplied carrying out 'B' check and the rate quoted deemed to be included for the same.
All as per item No. 47 above but for 320 KVA DG Set
All as per item No. 47 above but for 250 KVA DG Set
All as per item No. 47 above but for 200 KVA DG Set
All as per item No. 47 above but for 140 KVA DG Set
All as per item No. 47 above but for 100 KVA DG Set
M & L for earthing complete with GI earth plate electrode of size 600mm x600mmx 6.0 mm thick burried directly under ground vertically to a depth not less than 2.25 meter below ground level with top edge of the plate at a depth not less than 1.5 m below ground level connected to and including GI strip 32 x 6mm, by means of bolts, nuts, check nuts and washeres made out of GI including protection pipe GI light grade 40 mm size and watering pipe 20 mm dia GI medium grade all as shown on plate No 3 of SSR Part-I, connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 100mm c/c in both ways, including necessary form work complete including necessry test on completion & dismantling existing earthing all as specified and as directed.
M&L for strip opening AMF panel of 100 KVA to 200 KVA DG set, checking, inspecting, calibrating AMF panel ,replacing the burnt copper wiring with suitable flexible copper wire, inspecting the contactor coils & replacing the defective coils, cleaning the fixed/moving contacts with CTS complete including setting of AVR of Alternator complete incl testing & commissioning complete.
M&L for strip opening AMF panel of 250 KVA to 400 KVA DG set checking, inspecting, calibrating AMF panel , replacing the burnt copper wiring with suitable flexible copper wire , inspecting the contactor coils & replacing the defective coils, cleaning the fixed / moving contacts with CTS complete including setting of AVR of Alternator complete incl testing & commissioning complete.
Supply and fixing ON LOAD changerover front operated 4 pole 630 Amps all as directed. Make: L&T / Legrand / Havells / Siemens / C&S / GE
Supply and fixing ON LOAD changerover front operated 4 pole 400 Amps all as directed. Make: L&T / Legrand / Havells / Siemens / C&S / GE
M & L for repairing & servicing of self starter including replacement of commutator, carbon brush set with holder, king pin holder, armature, check nut body scrws, clutch plate assembly and solenoide etc., for DG set capacity 320 /400 KVA DG Set complete all as per manufacturer instructions and as directrd.
All as per item No. 58 here in above but for DG set of 250/200 KVA capacity
M & L repair and servicing of charging alternator including replacement of diode set with holders, bushes, bearing, varnishing, reassembling etc for 320/400 KVA DG Set complete all as per manufacturer instructions and as directrd.
All as per item No. 60 here in above but for DG set of 140/200/250 KVA capacity
Disconnecing / Removing existing un serviceable Battery of 12 V 180 AH from the DG set and supply, fix maintenance free battery of 12 V 180 AH capacity with minimum 2 years warranty including replacement of battery terminal clamp and testing and commissioning all as directed. [ Make: Exide / Amco / Amron / Amarraja]
Disconnecing/ Removing existing un serviceable Battery 12 V 90 AH from the DG set and supply, fix maintenance free battery of 12 V 90 AH capacity with minimum 2 years warranty including replacement of battery terminal clamp and testing and commissioning all as directed. [ [Make: Exide / Amco / Amron / Amarraja]
M & L for topping of Engine oil of grade 20 W 40 in DG sets all as directed and specified by Engr-In-Charge. Make : SERVO / VEEDOL / CASTROL
M & L for replacement of Diesel / fuel hose pipe set of DG set of any capacity complete all as directed.
Supply, calibrating, installing, setting, testing, commissioning of AVR panel for 62.5 - 400 KVA DG set, 415V, 3 phase, 4 wire system, Digital type, Voltage regulation: 10% of rated voltage,frequancy setting: 50/60 cycle, stability, doom settings, excitation voltage,currect to be matched with OEM instructions complete all as directed.
M&L for De-scaling of radiator by dismantling the upper & lower tank and cleaning the core pipes with cleaning chemicals, components and arrest the leaking core by brazing/ dummy with lead including cleaning of upper and lower tanks and replacing the upper and lower gaskets and required nuts, bolts, refixing the same including testing and painting complete all as specified and directed for the following capacities
62.5 to 400 KVA
M&L Earthing Electrode 3000 mm length copper coated earth rod, 100 microns thickness as per UL standard approved and testing by CPRI, pipe in pipe type inner pipe dia 41.9(min)mm, outer dia 76/80(min)mm annular space filled with high conductivity and anti corrosive compound with connection terminal. M&L infill compound (Chemical) 50Kgs ( 2 Bag each 25 Kgs) Elecrodite/ Humedites constituting natural element not water dissoble reduce soil resistivity highly hygroscopic and swells high conuctivity and anti corrosive retains moisture for a long time . M&L Earth work Vertical excavation in normal soil upto a depth of 3000mm the diameter of the bore hole being minimum 250 mm . installation filling the bottom 4" of the bore with infill compound ( Chemical) vertically placing the electrode in the centre of the pit ,fill the cavity around the electrode with the chemical ensuring there are no air gaps in the chemical filled cavity region make a thick paste by pouring water into the earth pit and mixing the mixture with a pole including PCC earth Pit and RCC Pit cover and dismantling existing earthing complete.
M&L earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as 32x6mm copper strip complete as directed
Supply and topping up of transformer oil with di-electric strength not less than 50 KV in to the conservator tank/ body tank of the transformer/ OCB/ FRMUs etc at various locations complete all as directed by the Engineer-in-Charge. [Make: Poweroil/ Transol/ Savita Chemicals]
Filtration of transformer oil of transformers/ FRMUs installed at various locations to achieve di-electric strength not less than 50 KV at 2.5mm gap as per relevant IS with portable filtration plant, testing of the oil for the di-electric strength before filtration and after filtration complete all as directed by the Engineer-in-Charge.
M & L for re-winding of HT 11/0.433 KV distribution transformer of capacity 200 ~ 750 KVA of any make by opening the Transformer core, HV windings, Insulating strips safely, inspecting the damaged winding , and re-winding the HV winding with new copper wires of same guage with new DPC insulation to the copper conductor , heating the core chamber to a suitable operating temperature etc as directed by Engr-in-charge, and assembling the cores, windings etc in the transformer completely all complete as specified.
M & L for re-winding of HT 11/0.433 KV distribution transformer of capacity 200 ~ 750 KVA of any make by opening the Transformer core, LV windings, Insulating strips safely, inspecting the damaged winding , and re-winding the LV winding with new copper wires of same guage with new DPC insulation to the copper conductor , heating the core chamber to a suitable operating temperature etc as directed by Engr-in-charge, and assembling the cores, windings etc in the transformer completely all complete as specified.
Supply and replace silica Gel into breather of transformers complete all as directed
M & L for shifting Transformer of capacity 200 KVA ~ 750KVA from its position at any substation at INHS Kalyani under AGE EM -I using cranes after disconnecting all the cables from HV/LV sides, securing the cable ends properly by insulating covering material, detaching all the earthing connections, transporting it to workshop for repair and transporting it back to the substation at INHS Kalyani and re-instating the transformer including all the cable connection, earthing connection , after doing insulation resistance test and restoring the electric supply as before all complete as specified and directed.
M & L for preparing old painted transformer surface with coarse cloth / wire brush, and spray painting transformer surface with synthetic enamel paint of smoke grey colour to a smooth finish appearance after applying one coat of zinc oxide primer for transformer capacity of 200 ~ 750 KVA complete all as specified and directed
Supply and laying un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm HV class with 'ELECTRIC' embossed on the top side in trenches along the electric cable as protection all complete as specified and directed.
Cutting the tarmac / hard standings to a width of 20cm and depth of 30cm and excavating in trenches across the road for laying cable including making good the excavated portion by means of PCC 1:3:6, type C1 matching with the surroundings complete all as specified and directed.
M & L GI pipe light grade 100 mm dia laid along road crossings / plinth protection with suitable fittings for cable protection or fixed to the pole / Wall complete all as specified and directed by Engineer-in-Charge. Make : Surya Roshni Ltd / Tata / Jindal steel / Prakash
S & F insulated synthetic mat nominal 2.5 mm thick conforming to IS: 15652-2006, ISI marked suitable upto 11 KV of Size 2.0 m x 1.0 m complete all as specified and directed by Engr-in-Charge ( MAKE: PREMIERPOLYFILM Ltd/SUNTEX INSULATICA/DUNLOP).
Supply & fix high voltage HT electrical insulation tape, self bonding/fusing, industrial grade ISI marked of size 38mm x 9.15 x 0.75mm, operating temperature 90 degree celcius applicable for voltge upto 36KV, 9Mtr long roll all as specified and directed
S & F Danger notice plate for LT of size 20 x 15 cm, 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts complete all as specified and as directed.
Supply and replace power contactor, 400Amps MCX 41 4Pole Contactor 415V + 2NO 2NC Contact, Conforming to IS / IEC 60947-4-1 & IEC 60947-4-13 all complete as specified and as directed. Make : L&T/ Schneider / Legrand / ABB / Siemens / C&S
M & L GI pipe light grade 50 mm dia laid along road crossings / plinth protection with suitable fittings for cable protection or fixed to the pole / Wall complete all as specified and directed by Engineer-in-Charge. Make : Surya Roshni Ltd / Tata / Jindal steel / Prakash
M & L for periodical inspection, checking, trouble shooting, fault rectification, comprehensive maint and repair/replacement of minor spares of 60 KVA UPS by certified technician for every three months complete all as specified and drectified.
S & F Danger notice plate for HT 25 x 20 cm, 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size complete all as specified and as directed.
Supply and replace ATS ( Automatic transfer Switch ) of 250 Amps rating, 415 V , 50 Hz AC supply in AMF Panel all as specified and directed. Make : L&T/ Schneider / Legrand / ABB / Siemens / C&S
Disconnecing / Removing existing un serviceable Battery of 12 V 150 AH and supply, fix maintenance free battery of 12 V 150 AH capacity with minimum 2 years warranty including replacement of battery terminal clamp and testing and commissioning all as directed. [ Make: Exide / Amco / Amron / Amarraja]
MONITOR ENGINEERING WORKS
SRI SAI KRISHNA ENGINEERING WORKS
general electricals
THE VENKATESWARA SUPPLIERS
SRIESWARI ENTERPRISES
VENKATESWARA ENGINEERS AND CONTRACTORS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .