Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.1 LAccepted-AOC MALAYNAGAR RENTERS COLONY AGARTALA WEST TRIPURA PIN 799004 | AGARTALA | WEST TRIPURA | TRIPURA | 799004 | ₹14.1 L | L1 | Accepted-AOC L1 |
| 2 | L2₹15.2 LRejected-AOC | ₹15.2 L | L2 | Rejected-AOC L2 |
Tender Value
₹14.9 L
EMD Value
₹29,767
Closing Date
23 Dec 2025, 3:00 pmClosed
The EE DWS AMC
EE DWS AMC
Installation of 06 (six) nos. Submersible Pump at different places under Ward No-30, AMC
2025_SAMC_68228_1
14/EE/DWS/AMC/2025-26
Open Tender
Civil Works
under DWS AMC
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,000
Yes
₹29,767
Yes
23 Mar 2026
10 Dec 2025
23 Dec 2025
10 Dec 2025
23 Dec 2025
10 Dec 2025
Drilling and boring of pilot hole in any strata by manual means, collection of soil sampales of different strata met with during drilling at various suitable levels and preservation of samples in plythene bags / sample boxes and disposal of excess soil or mud including the cost for water etc. as required to maintain the pilot hole properly as per specification and direction of the Engineer In Charge. (A) 100 mm dia.
Reaming of pilot hole to an enlarged bore hole in any soil starta by manual means, disposal of excess soil or mud, including the cost for water etc. as required to maintain the bore hole properly as per specification and direction of the Engineer-in-charge, A) From 100 mm dia pilot hole to 250 mm bore hole
Providing and fixing of UPVC end cap suitable for UPVC'CM" casing or 'CS' casing or 'RS' pipes as per specification and direction of the Engineer-in-charge, i) 100 mm dia
Providing & lowering of UPVC pipe as per IS:12818 after washing of the bore hole by manual means as per specification and direction of the Engineer-n-charge. A)'CM'casing pipe,i) 150 mm dia
Providing & lowering of UPVC pipe as per IS:12818 after washing of the bore hole by manual means as per specification and direction of the Engineer-n-charge. A)'CM'casing pipe,ii) 100 mm dia
Providing & lowering of UPVC pipe as per IS:12818 after washing of the bore hole by manual means as per specification and direction of the Engineer-n-charge. B) RS pipe i) 100 mm dia
Providing and fixing of UPVC reducer suitable for UPVC 'CM' casing or 'CS' casing or 'RS' pipes as per specification and direction of the Engineer-in-charge, ii) 150x100 mm dia
Washing and development of tube well by using hand pump or by any suitable method and testing of the well as per specification and direction of the Engineer-in-charge.
Providing and shrouding of the deep tube well assembly with washed pea gravels (2.0-4.75) mm effective size) as per specifiation (IS:4097) using deep drilling rig and direction of the Engineer-in-charge, A) with contracor's high power rig i) with pea gravels obtained from Durgapur, West Bengal.
Providing and fitting fixing G.I pipe (medium class0 conforming to IS:1239 for Mark II/III as per Specification and direction of the Engineer-in-chargee. 40mm NB
Fabrication of column pipe including providing &fitting fixing of G.I. flange by cutting the G.I pipe into 3.05 mtrs.size and welding the same with GI flange as per specification and direction of the Engineer-in-charge. (GI pipe will be issued by the Department at free of cost) i. For 50 mm dia GI pipe with 10 mm thick GI flange.
Providing and fitting fixing with PVC insulated 3 core flat copper cable conforming to relevant IS code for Submersible motor with all necessary equipments and fittings as required as per specification and direction of the Engineer-in-charge. i.2.50 sq mm.
Providing and fitting fixing steel sheet enclosed switch fuse unit (suitable for DIN fuses) triple pole with natural link (TPN) 415/500 Volt, L&T/Havells/BCH make etc. Complete as per specification and direction of the Engineer-in-charge.
Supplying and installation of water lubricated submersible pump having ISI marked of capacity 2000 GPH at total head up to 60 mtr. Cuple with submersible motor 2 HP suitable for 240 voltas (+10% variation single phase 50 HP, AC supply DOL starting method to run at 2880 RPM along with 35 mtr 2.5 sqm. PVC insulated 3 (three) core flate copper cables including fitting fixing and lowering if with 40mm dia GI pipe up to 100 FT (30,00 mtr) etc. complete as per direction ofthe Engineer-in-charge (40 mm dia GI pipe and fitting will be paid separately)
Supplying and installation of water lubricated submersible pump having ISI marked of capacity 2000 GPH at total head up to 60 mtr. Cuple with submersible motor 2 HP suitable for 240 voltas (+10% variation single phase 50 HP, AC supply DOL starting method to run at 2880 RPM along with 35 mtr 2.5 sqm. PVC insulated 3 (three) core flate copper cables including fitting fixing and lowering if with 40mm dia GI pipe up to 100 FT (30,00 mtr) etc. complete as per direction ofthe Engineer-in-charge (40 mm dia GI pipe and fitting will be paid separately)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_69420.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.12 MB
DNIeT14.pdf
Tender Documents • 2.65 MB
BOQ_69420.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid