Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹7.1 LAccepted-AOC | L-1 | Accepted-AOC Being L-1 | |
| 2 | Rejected-Technical | - | Rejected-Technical As the firm failed to submit valid registration certificate as Contractor with CPWD, MES, NBCC, BRO, Other Central Govt. Department or Concerned State PWD, hence Disqualify for next stage. |
Tender Value
₹7.2 L
EMD Value
₹14,319
Closing Date
11 Nov 2023, 12:00 pmClosed
Commandant (Engineer)
CONTRACT CELL, CENTRAL ZONE HQR, CRPF, H.C. BLOCK, SECTOR-III, SALT LAKE, KOLKATA (W.B.) PIN-700106
Repairing, Painting and Rehauling Work of 750 KLD STP and Repair, maintenance and Servicing of Pump Motors for WTP, STP and Swimming Pool cum Diving Pool
2023_CRPF_778384_1
B.V(CoBRA Complex)/ 2023-24-CZ-C/Cell(NIT-125)
Open Tender
Civil Works - Buildings
Works
45 days
CoBRA Complex, TAC HQr, Jagdalpur, Bastar, (C.G)
As per tender Enquiry
16 documents required · 16 mandatory
₹0
₹14,319
13 Jan 2024
28 Oct 2023
13 Nov 2023
28 Oct 2023
11 Nov 2023
28 Oct 2023
Amount
Civil Work
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
Distempering with 1st quality acrylic distember (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade : Old work (one or more coats)
Finishing walls with Acrylic Smooth exterior paint of required shade : Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work
12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge
Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20mm nominal size)
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate
Surface dressing of the ground including removing vegetation and in equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m: All kinds of soil
1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern.
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. 0.63 mm thick with zinc coating not less than 275 gm/ m²
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial desilting of manholes and dechocking of sewer lines. Dechocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150mm dia upto 300mm
De-silting of thickly sedimented sludge/sewage and de watering ( Sewage water) from sewage collection Chember 05 Nos by mannual/ mechanical means up to bottom level of Chember , safe and healthy disposal of Sludge/effluent and disinfecting the Chember using bleaching powder completely in all repsect.
Repair, maintenance and services of pump motors fpr WTP, STP and swimming pool cum diving pool
MCB 3- phase
Belt (rubber)
Bearing
Insulation
Fan (motar)
Grease
Panel button (STP)
Panel wiring plate
Starter Coil
Wire 1.5 mm
Filter (Motar)
Replacement of damaged induction mortar STP (0.5 HP)
Labour charges :- Greasing, oiling Lubrications , repair and rectification of electrical control panel with replacement of all relevent component and circuit rewiring works for STP of service, repair of motors (10 HP-8 Nos ,7 HP-5 Nos and 5 HP-12 Nos)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .