Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 LAccepted-AOC H NO 33 VPO KHERI SALABAT PUR DISTT RUPNAGAR PUNJAB 140111 | RUPNAGAR | RUPNAGAR | PUNJAB | 140111 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹5.5 L+₹49,589 (9.96%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹6.3 L+₹1.3 L (26.5%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L3 | Rejected-Finance Being L3 |
| Sl No | Description | Qty | Unit | SANJEEV ENTERPRISES L3 | M/S BALWINDER SINGH L2 | LA ENTERPRISES L1 |
|---|---|---|---|---|---|---|
| 1.00 | Overhauling to the unserviceable compressor semi sealed type capacity 8.5/5.5 ton by opening, dismantling of compressor, necessary machining / mechanical repair work etc and replacement of worn-out spare parts for smooth functioning of compressor, reassembling and testing for satisfactory operation. The spare parts & other items required for replacement shall be measured and paid under Sch 'A' effective items separately. The spare parts which are not mentioned but are required for smooth and proper functioning / operation of compressor are deemed to include in the unit job complete all as specified and directed.
Note :- Refrigerant gas and compressor oil shall be measured and paid for separately under relevant item of Sch 'A'. | 8 | Each Job | 6,800 ₹54,400 | 750 ₹6,000 Lowest | 1,000 ₹8,000 |
| 2.00 | Supply and fixing in replacement following sections/sizes of V-belt as per existing pattern complete all as specified and directed. | 4 | Each | 175 ₹700 | 200 ₹800 | 170 ₹680 Lowest |
| 3.00 | Supply and filling compressor oil complete all as specified and directed. | 10 | Litre | 365 ₹3,650 | 380 ₹3,800 | 130 ₹1,300 Lowest |
| 4.00 | Material and labour for taking out / purging of refrigerant gas from the system of A/c plant unit upto 1x 17 TR capacity for carrying out vacuum test by vacuuming the whole A/c plant with the help of vacuum pump and checking the complete system for leakages. Carrying out the pressure test by charging the nitrogen gas in the system and checking of any leakage point , repair / rectification of the same and removing the nitrogen gas from the system and charging of refrigerant gas including charging of additional gas as required complete all as specified and directed.
Note: The arrangement of T&P Nitrogen gas shall be contractors responsibility
Note : Refrigerant gas shall be measured and paid for separately. | 12 | Each job | 2,300 ₹27,600 | 700 ₹8,400 Lowest | 900 ₹10,800 |
| 5.00 | Material and labour for charging of refrigerant gas R-22 in AC plant complete all as specified and directed. | 78 | Kilogram | 890 ₹69,420 | 1,000 ₹78,000 | 800 ₹62,400 Lowest |
| 6.00 | Supply and fixing in replacement super enamelled copper winding wire complete all as specified and directed | 3 | Kilogram | 650 ₹1,950 Lowest | 700 ₹2,100 | 1,000 ₹3,000 |
| 7.00 | Supply and fixing in replacement ball bearing as existing pattern complete all as specified and directed. | 12 | Each | 185 ₹2,220 Lowest | 350 ₹4,200 | 200 ₹2,400 |
| 8.00 | Repair and overhauling to air handling unit of central AC plants, dismantling of air filters and cleaning the cooling coil with chemical and refixing the air filter after cleaning and testing and greasing the bearing of blower shaft etc for sector 30 AC plant complete all as specified and as directed. | 1 | Each Job | 1,200 ₹1,200 | 1,000 ₹1,000 Lowest | 1,200 ₹1,200 |
| 9.00 | Repair and overhauling to air handling unit of central AC plants, dismantling of air filters and cleaning the cooling coil with chemical and refixing the air filter after cleaning and testing and greasing the bearing of blower shaft etc for sector 37 AC plant complete all as specified and directed | 1 | Each Job | 1,200 ₹1,200 | 1,000 ₹1,000 Lowest | 1,200 ₹1,200 |
| 10.00 | Servicing of cassette type/ HI wall split type indoor units of cap 1.28/2.0/3.18/1.5/5.5 TR installed at sector 30 Chandigarh complete all as specified and directed. | 20 | Each Job | 1,200 ₹24,000 | 500 ₹10,000 Lowest | 900 ₹18,000 |
Tender Value
₹6.5 L
EMD Value
₹13,100
Closing Date
11 Dec 2025, 6:00 pmClosed
GE I R AND D Chandigarh
Garrison Engineer I R and D, DIHAR Base Lab, Ground Floor, Near 3 (BRD) AF Stn, Industrial Area, Ph-II, Ramdarbar, Chandigarh
REPAIRS AND MAINT OF CENTRAL AC PLANTS ALONGWITH PANELS AND OTHER CONNECTED ITEMS AT SEC 37 CHANDIGARH
2025_MES_740468_1
GE (I) R AND D/CHD-113/2025-26
Open Tender
Civil Works
Item Rate
180 days
Chandigarh
As per tender documents
8 documents required · 8 mandatory
₹500
GE I R AND D Chandigarh
₹13,100
Yes
6 Feb 2026
19 Nov 2025
13 Dec 2025
19 Nov 2025
11 Dec 2025
4 Dec 2025
Amount
Overhauling to the unserviceable compressor semi sealed type capacity 8.5/5.5 ton by opening, dismantling of compressor, necessary machining / mechanical repair work etc and replacement of worn-out spare parts for smooth functioning of compressor, reassembling and testing for satisfactory operation. The spare parts & other items required for replacement shall be measured and paid under Sch 'A' effective items separately. The spare parts which are not mentioned but are required for smooth and proper functioning / operation of compressor are deemed to include in the unit job complete all as specified and directed. Note :- Refrigerant gas and compressor oil shall be measured and paid for separately under relevant item of Sch 'A'.
Supply and fixing in replacement following sections/sizes of V-belt as per existing pattern complete all as specified and directed.
Supply and filling compressor oil complete all as specified and directed.
Material and labour for taking out / purging of refrigerant gas from the system of A/c plant unit upto 1x 17 TR capacity for carrying out vacuum test by vacuuming the whole A/c plant with the help of vacuum pump and checking the complete system for leakages. Carrying out the pressure test by charging the nitrogen gas in the system and checking of any leakage point , repair / rectification of the same and removing the nitrogen gas from the system and charging of refrigerant gas including charging of additional gas as required complete all as specified and directed. Note: The arrangement of T&P Nitrogen gas shall be contractors responsibility Note : Refrigerant gas shall be measured and paid for separately.
Material and labour for charging of refrigerant gas R-22 in AC plant complete all as specified and directed.
Supply and fixing in replacement super enamelled copper winding wire complete all as specified and directed
Supply and fixing in replacement ball bearing as existing pattern complete all as specified and directed.
Repair and overhauling to air handling unit of central AC plants, dismantling of air filters and cleaning the cooling coil with chemical and refixing the air filter after cleaning and testing and greasing the bearing of blower shaft etc for sector 30 AC plant complete all as specified and as directed.
Repair and overhauling to air handling unit of central AC plants, dismantling of air filters and cleaning the cooling coil with chemical and refixing the air filter after cleaning and testing and greasing the bearing of blower shaft etc for sector 37 AC plant complete all as specified and directed
Servicing of cassette type/ HI wall split type indoor units of cap 1.28/2.0/3.18/1.5/5.5 TR installed at sector 30 Chandigarh complete all as specified and directed.
Supply and fixing in replacement display controller complete unit of package type /central type AC plants of various capacity complete all as specified and directed.
Supply and fixing in replacement finned strip heater having terminal at one end and two holes at another end for installation, 240 volt, 3 KW complete all as specified and directed.
Material and labour for preparation of old painted surfaces of control panels of AC plants of any capacity and applying two coats of synthetic enamel paint on steel/iron surfaces complete all as specified and directed.
Supply, install, testing and commissioning of hermetically sealed scroll compressor of capacity 8.5 Ton compatible with R22 refrigerant gas , suitable for duct able AC complete all as specified and directed.
Supply, install, testing and commissioning of hermetically sealed Scroll compressor of capacity 5.5 Ton compatible with R22 refrigerant gas , suitable for duct able AC complete all as specified and directed.
Supply and fixing for display board for electric shock treatment chart/ maintenance chart/ description chart of size 850x600 mm made out of CRCA sheet 2 mm thick with square pipe 35 mmx35 mm fixed around sheet by welding and making hanging arrangements on top of the board. Board shall be painted with two coats of stove enamelled paint (navy blue) over a coat of red oxide primer and writing the detail with fluorescent reflective tape (as per sample) by digital computerized printing style complete all as specified and directed.
Supply and fixing synthetic insulating rubber mat of size 2 metre x 1 metre x 19 mm (ISI Marked) suitable for control panels of AC plants complete all as specified and directed.
Supply and fixing in repair MCCB rating 100 amps, 4 pole, 415 volts breaking capacity 16 KA complete all as specified and directed.
Supply and fixing in repair MCCB rating 200 amps, 3 pole, 415 volts breaking capacity 36 KA complete all as specified and directed.
Supply and fixing in repair MCB SP 6 to 32 amps 240 volts 10 KA 'B' series complete all as specified and directed.
Supply and fixing in repair MCB TPN rating 32 amps, 4 pole, C-type, 415 volts breaking capacity 10 KA complete all as specified and directed.
Supply and fixing in repair MCB TPN rating 40 amps, 4 pole, C-type, 415 volts breaking capacity 10 KA complete all as specified and directed.
Supply and fixing in repair MCB TPN rating 63 amps, 4 pole, C-type, 415 volts breaking capacity 10 KA complete all as specified and directed.
Taking out old unserviceable power/auxiliary contactor from control panel / starter and supply and fix new power contactor of of AC3 rating 12 Amps MNX type and capacity complete all as specified and directed
All as per serial item no 24.00 above but power contactors AC3 rating 22-25 amps ML type -ditto-.
All as per serial item no 24.00 above but power contactors AC3 rating 32-40 Amps ML type -ditto-
Supply and fixing in replacement of terminal block connector complete all as specified and directed.
Supply and fixing in replacement phase failure relay with fixed under & over voltage cut out complete all as specified and directed.
Supply and fixing in replacement digital volt meter complete all as specified and directed.
Supply and fixing in replacement digital ampere meter complete all as specified and directed.
Supply and fixing in replacement three phase preventor complete all as specified and directed.
Supply and fixing in replacement temperature control switch complete all as specified and directed.
Supply and fixing in replacement indicating light universal complete all as specified and directed.
Supply and fixing in replacement toggle switch 15 amps complete all as specified and directed.
Supply and fixing in replacement thermostat for heating control range 0-30 degree centigrade complete all as specified and directed.
Material and labour for painting to existing AC installations sign board of size 1.2 metre x 1.0 metre with two coats of synthetic enamel paint approved colour over a coat of primer and writing letters in 4 inches sizes and colours as required including scrapping out old rusted paints complete all as specified and directed.
Supply and fixing in replacement PCB complete all as specified and directed.
Taking out old unserviceable timer switches from LT panel / starter and supply and fix new timer switches timer switch range 0 to 60 second complete all as specified and directed.
Supply only the new remote control unit (cordless) as per existing model for cassate type/1.5 TR/ 2 TR split type A/C unit complete all as specified and directed.
Supply and fixing on wall/existing conduit and testing cable XLPE Insulated , PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core with thimble arrangement complete all as specified and directed.
Supply and fixing on wall/existing conduit and testing cable XLPE Insulated , PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core with thimble arrangement complete all as specified and directed.
Material and Labour for earthing complete with galvanised steel earth plate electrode 60cm X 60cm X 6.0mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5mtr below normal ground level connected to GI earth strip of size 32x6 mm by means of bolts, nuts, check nuts and washers of galvanised iron complete earth pit of PCC M-10(Nominal mix) using 20mm graded stone aggregate, 50mm thick earth pit cover of RCC M-15 (Nominal mix) using 20mm graded stone aggregate with MS TMT reinforcement bar of 8mm dia @ 150mm centre to centre both ways, MS handle 10mm dia made to shape, PGI funnel, wire mesh and 20mm bore GI water pipe medium grade and 40mm bore light grade GI pipe for protection of earth strip from plate to main switch board, common salt, charcoal dust including testing on completion complete all as specified and as directed all as shown in electrical plate No. 5 including testing on completion and making good the disturbed surfaces of wall floors etc without claiming extra cost complete all as specified and dircted. Note: GI strip & GI pipe beyond 7.5Mtr length from earth electrode shall be measured and paid for separately.
M/S BALWINDER SINGH (BID ID -3501288)
SANJEEV ENTERPRISES (BID ID -3500480)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.47 MB
BOQ_829142.xls
BOQ • 0.27 MB
Tenderdocuments113.pdf
Tender Documents • 1.52 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .