Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 LAccepted-AOC PERUMAMATTEM PINARMUNDA KUNNATHUNADU ERANAKULAM | ERNAKULAM | KERALA | 680667 | ₹1.4 L | L1 | Accepted-AOC LOWESTBID aCCEPTED |
| 2 | Rejected-Technical | - | - | Rejected-Technical L2 |
| Sl No | Description | Qty | Unit | ABDUL MANAF L1 | K D George L2 |
|---|---|---|---|---|---|
| 1.00Maintenance Work | |||||
| 1.00 | 10.1:Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. | 140 | kilogram | 115.52 ₹16,172.8 Lowest | 118.99 ₹16,658.6 |
| 1.00 | OD504365/2025-2026:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.35 mm (+0.05%), total coated thickness with zinc coating 120 grams per sq m as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side. of the sheet and polyester top coat 15-18 microns.Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length up to 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with E P D M seal, complete up to any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Details of cost for 216.14sqm
(External dimension of plinth)
Area of roof
20.2x10.70m=216.14sqm
Sheets Used = 20Nos x 10.70m x 1.06m = 226.84sqm
add 3% wastage = 6.81
Total = 233.65sqm | 28 | sqm | 614.89 ₹17,216.92 Lowest | 633.34 ₹17,733.52 |
| 1.00 | OD504362/2025-2026:Providing and fixing 200mm wide square uPVC rain water gutter including all necessary
fittings and making all necessary connections complete as per the direction of engineer in
charge at site. | 10 | metre | 496.49 ₹4,964.9 Lowest | 511.38 ₹5,113.8 |
| 1.00 | 50.18.9.17.2:Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 4 Kgf/cm2- External work - exposed on wall | 5 | metre | 246.18 ₹1,230.9 Lowest | 253.57 ₹1,267.85 |
| 1.00 | 50.18.9.18.1:Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall | 9.5 | metre | 301.71 ₹2,866.25 Lowest | 310.76 ₹2,952.22 |
| 1.01 | 50.18.9.21:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Elbow | 5 | no | 98.92 ₹494.6 Lowest | 101.89 ₹509.45 |
| 1.01 | 50.18.9.21.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Bend | 5 | no | 92.58 ₹462.9 Lowest | 95.36 ₹476.8 |
| 1.01 | 50.18.9.22.12:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x75 mm dia Reducer | 5 | no | 112.01 ₹560.05 Lowest | 115.37 ₹576.85 |
| 1.01 | 50.18.9.22.2:Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow | 5 | no | 109.7 ₹548.5 Lowest | 112.99 ₹564.95 |
Tender Value
₹1.4 L
EMD Value
₹3,493
Closing Date
19 Mar 2026, 10:00 amClosed
ASSISTANT ENGINEER
OFFICE OF THE ASSISTANT ENGINEER,SREEMOOLANAGARAM GP
SMN- 224/25-26-Renovation of Vijayan Smaraka Community Hall -Second Phase in Sreemoolanagaram GP
2026_LSGD_846508_1
56/AESMN/LIDEW/25-26
Open Tender
Civil Works - Others
Item Rate
240 days
Sreemoolanagaram
Please refer Tender documents.
6 documents required · 6 mandatory
₹555
₹3,493
15 Sept 2026
12 Mar 2026
20 Mar 2026
12 Mar 2026
19 Mar 2026
12 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Maintenance Work | |||||
| 1.001 | 10.1:Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. | 140 | kilogram | - | - |
| 1.002 | OD504365/2025-2026:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.35 mm (+0.05%), total coated thickness with zinc coating 120 grams per sq m as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side. of the sheet and polyester top coat 15-18 microns.Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length up to 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with E P D M seal, complete up to any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Details of cost for 216.14sqm
(External dimension of plinth)
Area of roof
20.2x10.70m=216.14sqm
Sheets Used = 20Nos x 10.70m x 1.06m = 226.84sqm
add 3% wastage = 6.81
Total = 233.65sqm | 28 | sqm | - | - |
| 1.003 | OD504362/2025-2026:Providing and fixing 200mm wide square uPVC rain water gutter including all necessary
fittings and making all necessary connections complete as per the direction of engineer in
charge at site. | 10 | metre | - | - |
| 1.004 | 50.18.9.17.2:Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 4 Kgf/cm2- External work - exposed on wall | 5 | metre | - | - |
| 1.005 | 50.18.9.18.1:Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall | 9.5 | metre | - | - |
| 1.006 | 50.18.9.21:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Elbow | 5 | no | - | - |
| 1.007 | 50.18.9.21.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Bend | 5 | no | - | - |
| 1.008 | 50.18.9.22.12:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x75 mm dia Reducer | 5 | no | - | - |
| 1.009 | 50.18.9.22.2:Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow | 5 | no | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.09 MB
sbd.pdf
Tender Documents • 1.72 MB
BOQ_1430113.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .