Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.0 LAccepted-AOC 0 0 BASANT AVENUE PHASE II PUNJAB GURDASPUR PUNJAB 143505 | GURDASPUR | PUNJAB | 143505 | L1 | Accepted-AOC Being the lowest bidder | |
| 2 | L2₹37.9 L+₹58,828 (1.58%)Rejected-AOC | L2 | Rejected-AOC Being other than lowest bidder | |
| 3 | L3₹39.7 L+₹2.4 L (6.39%)Rejected-AOC | L3 | Rejected-AOC Being other than lowest bidder | |
| 4 | L4₹40.3 L+₹3.0 L (8.03%)Rejected-AOC BUNGALOW NO 21 CANTONMENT BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | L4 | Rejected-AOC Being other than lowest bidder | |
| 5 | L5₹40.4 L+₹3.1 L (8.40%)Rejected-AOC | L5 | Rejected-AOC Being other than lowest bidder |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
12 Sept 2024, 6:00 pmClosed
GE EAST BAREILLY
Garrison Engineer East Military Engineer Services Shahjahanpur Road Bareilly Cantt
MAINT AND REPAIR OF LOWERING / LIFTING OF SUBMERSIBLE PUMP AND MOTOR, CENTRIFUGAL PUMP AND MOTOR, INCL REPLACEMENT OF PARTS, CLEANING OF OVER HEAD TANK/SEMI UG SUMP AND ALLIED WORKS OF WATER SUPPLY AT HQ UB AREA UNDER GE (EAST) BAREILLY.
2024_MES_661549_2
8349/E8
Open Tender
Civil Works
Item Rate
245 days
BAREILLY
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE EAST BAREILLY
₹98,000
Yes
16 Nov 2024
18 Jul 2024
14 Sept 2024
18 Jul 2024
12 Sept 2024
25 Jul 2024
18 Jul 2024 - 24 Jul 2024
Amount
M&L for Lifting/taking out defective submersible pump of any capacity alongwith column pipe of any size and submersible cable, dismantling the pump from motor, setting aside for repair / servicing / overhauling including lowering the pump set into borewell replacement of packing and nut bolts (if required) and testing after the completion of repair works in the presence of JE/ Engr in charge.
M&L for rewinding to submersible motor 50 HP of any make with super enameled copper winding wire PVC coated 2 mm thick as per taken out qty, Providing PVC separators, PVC sleeves & jointing compound complete all as specified and directed. Note:- Replacement items will be measured and paid seprately under relevent item. If the same motor copper winding wiring burnt due to poor workmenship, second time in the above CA Period, The contractor is responsible to paid and rewind the same at their own cost.
All as per item no 02 above but capacity 41 Hp
All as per item no 02 above but capacity 10/15Hp
All as per item no 02 above but capacity 5/7.5Hp
Repair/Replacement of following parts of the submersible pump and motor for capacity 40/41/50/1015/7.5 HP of original company as approved by Accepting officer. Make : KSB, Crompton, Kirlosker
Thrust bearing plate made out of carbon for submersible motor
Gun metal bush for submersible motor
Shaft sleeve made out of stainless steel for submersible motor
Clamp stud for submersible motor
Rotor balancing of submersible motor
Shaft grinding of submersible motor
GM Neck Ring for submersible pump
Stainless steel sleeve for submersible pump
Stainless steel pump shaft for submersible pump
Stainless steel impeller for submersible pump
Cast iron bowl for submersible pump
Rubber bush for submersible pump
M&L for Painting to pipe of pump house rising mains hydrants, sluice valves, pipe, fittings, NRV, discharge head etc after cleaning, scrapping and making the surfaces free from rust of main externally and painting with two coats synthetic enamelled paint in black / blue / red including marking / writing on pipe etc complete as specified and directed
S&F in repair electric shock treatment chart coloured of size approximetely 900 x 600 x 6 mm thick plywood with teak wood frame including covered with plastic laminated sheet complete all as specified and directed.
S&F in repair machinary maintenance chart coloured of size approximately 3 ft x 2 ft & 6 mm thick plywood with teak wood frame including covered with plastic laminated sheet complete all as specified and directed.
M&L for trimming vegetation or small inequalities clearing all grass vegetation, saplings, shrubs, brushwood, roots, and tree of surroundings area up to 500 sq mtr including cleaning and removing rubbish upto a distance of 50 mtr outside the periphery of the area under clearance of water supply installations complete all as specified and as directed. Note-trimming will be done two times during contrct period at all installations of water supply. etc complete as specified and directed
S&F in repair for Aviation light on OH tank 18/21 mtrs staging (on top of OH tank) with all fittings, fixtures and accessories including 2.5 sqmm wire Three core in 20 mm PVC conduit from light to connection points including 2-way MCB DB with isolator (10 Amp) capacity complete all as specified and directed.
Supplying, Laying, jointing and testing 2.5 Sq mm 2 core, PVC insulated, armoured, heavy duty, Copper conductor cable 1100 volts grade, laid in trenches / ducts, floors, fixed to pole / walls etc. complete all as specified and directed.
S&F in repair for glow sign board (box type) LED of required size 3600 x 600x300 mm made out of MS sheet of suitable size with sheet fixed on front and quality marked with details of Pump House etc on front and rear with different colours including provision of LED power- fittings & fixtures in equal distance to illuminate board including connections with 2.5 sqmm single core stranded copper conductor cable and writing with 10 mm size letters as specified and directed .
Supply & fix in repair 1100 volts grade heavy duty cable PVC insulated aluminum conductor screenedserved with inner sheathing of PVC tape and over all PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4mm GI suspension wire, one twin core cables flat or circular of size 10 Sqmm etc complete all as specified and directed.
S&F in repair Off load change over switch 200 Amp, 4 pole, 415 Volt, etc complete all as specified and directed
Supply and fix in repair energy saving and environemntal friendly long life versatile pressure die-cast aluminium IP-65 roadway luminaire 72 W LED fitting with high power LEDs light source and electronic driver etc complete as specified and directed
S& F in replacement new generation post top energy saving environment friendly, long aesthetically designed with symmetrical light distribution spun aluminium landscape luminaire with power LED,s of 35 Watt as light complete all as specified and directed
S & F in replacement of street light brackets 40 mm bore GI pipe medicum grade upto 1.5 mtr long bend to shape including flat iron clamps and sutable nuts and bolts .etc complete all as specified and directed
Material and labour for replacement of PVC insulated single core multistranded copper cable of size 1.5 sq mm unsheathed 1100 volts grade drawn through conduit / casing capping on surface / pole / wall concealed and making good of disturbed surface including taking down unserviceable wire etc complete all as specified and directed
S&F Bldg Security light energy efficient 1X20 Watt LED 6K Endura cityliner leaf die cast aluminium and fixing arrangement of fitting including 1 mtr 35/50mm GI 90 degree bend pipe complete all as specified.
M&L for Earthing complete with using GI earth plate electrode 600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness off 15 cm all around the plate with using 4 mm dia GI Wire as earth lead moulded and retreived to earth plate at one end and connected to main switch / control board at another end with and including 15 mm dia GI light grade from upper end of earth plate upto external face of the wall of the building including 20 mm dia bore GI pipe light grade as water pipe from chamber to upper edge of the plate GI funnel with wire mess fixed on water pipe and provison of PCC 1:2:4 type B-1 (Using 20 mm Dia graded stone aggregate) duly reinforced with mild steel round bar 6 mm dia @ 150 mm c/c both ways with 10 mm dia mild steel bars as in lifting handle with and including necessarry excavation and earth work including laying the pipe concealed in floor / wall allas per plate NO-3 of SSR Part-I complete all as specified and directed and testing on completiopn (Note:- If the desired resistance is not found earthing shall be done by the contractor at no extra cost to Govt).
Supply & replacement of Contactor ML-3 ,suitable to operate 35-45 HP submersible pumping set Cat part No SS-90721 Make-L&T or equivalent to approved make as specified in CA.
Supply & replacement of Contactor ML-4 ,suitable to operate 50-60 HP submersible pumping set Cat part No SS-90910 Make-L&T or equivalent to approved make as specified in CA.
S&F in repairs electronic timer type ST 100 suitable for operation on 415 volts 50 Hz for 3-30 Sec all as specified and as directed.
S&F in repairs electronic Single phase preventer operation on 415 volts 50 Hz all as specified and as directed.
S&F mini motor protection relay for 35-51hp submersible motores of make L&T all as specified amd directed.
Supply and fix in repair spare conntact kit for ML 3 contractor complete all as specified and directed.
Supply and fix in repair spare conntact kit for ML 4 contractor complete all as specified and directed.
M&L MCCB 4 pole, 415 Volt, fixed type 125 to 160 amp with breaking capacity 36 Ka complete all as specified and directed.
M&L MCCB 4 pole, 415 Volt, fixed type 160 to 200 amp with breaking capacity 35 kA complete all as specified and directed.
M&L seven stage cleaning and sterilization inside the underground / semi under ground sump of 50,000 Gallons capacity through bacteriological treatment by using TERBACK G5 TERBACK G10 TERBACKG65 and UV RAY by involving the following seven (7) stages of cleaning process including cleaning the external surfaces, structure for all scales and other particles any algae, hives and any type with cement and sand mortar (1:4) and applying one coat of white wash to internal surface when became dry and two coat of white wash to external surface complete all as specified and directed. Seven (7) stages of cleaning process as under : (a) First stage is to draining out the reserved water by using exit valve or high capacity pump of dewatering system. (b) Second stage is cleaning all the the algae formation inside the tank removing all scale, dirt, mud inside the tank by using TERBAC G10 Chemical complete. (c) Third stage is scrubbing the walls and floor with mechanized scrubber & fresh water cleaning by high speed jet pump (rotary & flat) to remove all scaling, algae and other formed particles on internal surfaces of the tank completely. (d) Fourth stage is first bacteria screening i.e de-verification by using TTERBACK G5 chemical complete. (e) Fifth stage cleaning the floor of the water tank by heavy duty industrial vacuum cleaner and sludge sucker maximum 1200 W with suitable heavy duty rugged motor to make sump free of any foreign and loose particles of any nature. (f) Sixth stage is second bacteria screening and sterilization method by using UV RAYS by heavy duty UV radiation which shall have 360 degree of sterilization with in the tank to kill all suspended bacteria (The radiation shall portable and effective for sterilization of drinking water tanks for diminution of floating and suspended bacteria).
(g) Seventh stage of cleaning and third screening is to sterilize the floor and wall of the water tank by using laboratory certified branded strong TERBACK G65 or equivalent any non toxic bio-degradable eco-friendly anti-bacterial agent certified by a Govt. approved laboratory to disinfect the tank from all harmful pathogens. Note : (i) Entire T& P should be arranged by the contractor at their own. Only electric power & water shall be supplied by MES at all stipulated rate. (ii) “Date of cleaning” should be written over the outer surface of tank by synthetic enamel paint with lettering not less than 100 mm height. (iii) All safety equipments required like safety helmets, Gumboots, safety belt, mask, safety goggles and necessary insurance for safety of working labors to execute the work is responsibility of the contractor and rates quoted shall be deemed to inclusive of the same. (iv) Contractor will submit Govt laboratory test certificate of TERBAC-G5, TERBACG-10 AND TERBAC G-65.
All as per Srl item No 33 here in before but capacity 25000 gallon.
Supplying & Laying Sub Class `B’ bricks old size with axis of the bricks perpendicular to the axis of the cable as in cable protection all as specified and directed.
M&L Calcium based granularhypo chlorite 65% to 70% disinfectant for water treatment ,Packing in 45 KG ,plastic drums complete all as specified and directed .
Taking out connection of Chlorine / Altoch dosing system , detecting fault and repair /replacement of unserviceable parts and refixing same after completion job and connecting dosing system and testing complete all as specified and directed. (NOTE:- Spares parts shall be measured and paid separately as Supply only ) as under :-
M&L rotor assembly with bearing brackets and tolerance rings suitable for decree dosing pump complete all as specified and directed.
M&L pump tube suitable for dosing pump complete all as specified and directed.
Supply only injectior assembly suitable for dosing pump complete all as specified and directed.
M&L duckwill suitable for dosing pump complete all as specified
M&L diaphragm assembly suitable for dosing pump complete all as specified
M&L weighted suction line stainer suitable for dosing pump complete all as specified and directed.
M&L Agitator Motor electric driven 230 Volt 50 Hz, single phase, 120 W & 900 RPM copper wounded complete all as specified and directed.
Supply only PVC pipe as per existing size all as specified
Supply only grass and weeds killer chemical of make Roundup all as specified and directed.
S&F rubber mat of size 1mtrx2mtrx 12mm at installation of etc complete as specified and directed
S&F pressure gauge of dial 30 to 60 suitable for fixing at 100/150 header mm pipe with all fiting andf fixtures etc complete as specified and directed
S&F in replacement of PVC bib tap 15 mm.bore etc complete as specified and directed
M&L for dismantling of motor, 3 phase, 7.5 KW, taking out burnt winding wire from stator, cleaning all slots properly, repair of pump and rewinding the motor with proper guage of super enamelled winding wire and varnishing properly including baking and providing insulation and packing properly re-assembling the motor with pump and installed at its proper position and testing the same including connection plate etc complete as specified and directed.
M&L for dismantling of non clog type centrifugal pump set of capacity 12.5hp either fixed or floor or on trolley mounred and taling out unsv spares and performin following operation to complete the task-: Rewinding of the motor centrifugal pumping set with insulated copper winding including sleeves as per original approved and replacement of worn out parts including griding of parts testing & transport charges complete all as specified and directed. replacement of motor bearing with lock nut -02 Nos Repalcement of fan motor-01 No Replacement of star coupling set with rubber-01 Each
Take the water sample from the bore well at ph no. 12, 25, 27, 28, 29, 30, 31, 32, 33, 34, 36, 37, 38, 41, 26, 20, 21, 22, 37 MH PH and two consumer end and send it for physical / Chemical / Bateriological test from any recognised govt agency and provide its report to Engr in charge.
S& F in replacement submersible pump and motor electric driven 415 Volts, TP suitable for 200/250 mm bore well casing pipe size 200/250 mm supply complete of 40 HP all as specified and directed. Note:- Old unsv pump and motor will be deposited in MES store
S& F in replacement submersible pump / motor electric driven 230 Volts , SP suitable for 25 mm bore well casing pipe size 50 mm supply with staster complete of 01 HP all as specified and directed. Note:- Old unsv pump and motor will be deposited in MES store
S& F in replacement Pressure Booster Pump / motor electric driven 230 Volts , SP suitable for 20/25 mm bore with staster complete of 01 HP all as specified and directed. Note:- Old unsv pump and motor will be deposited in MES store
S& F in replacement HI Flow 1 HP Centrifugal pump / motor electric driven 230 Volts , SP suitable for 20/25 mm bore with staster complete all as specified and directed. Note:- Old unsv pump and motorwill be deposited in MES store
Supply fixing testing and commissioning submersible cable flat 16 sqmm 3 core PVC insulated and PVC sheathed with multi stranded copper conductor 1100 volts grade fixed to submersible motor column pipe using suitable size of clamps made out of stainless steel flat of size 20x2 mm with steel nuts bolts & washer foe every column pipe of 3 mtr lenght all as specified and directed.
Supply fixing testing and commissioning submersible cable flat 1.5 sqmm 2 core PVC insulated and PVC sheathed with multi stranded copper conductor 1100 volts grade fixed to submersible motor column pipe using suitable size of clamps made out of stainless steel flat of size 20x2 mm with steel nuts bolts & washer for every column pipe of 3 mtr lenght all as specified and directed.
Demolition for cement concrete/road in ground floor and paving n. exc 15 cm thickness below or above ground level including removal of rubbish to a distance exc 1.50 Km and n.exc 5.00 Km etc complete all as specified and directed
M & L for 100 mm thick PCC 1:2:4 type B2 (using 40 mm graded stone aggregate) complete all as specified and directed .
M & L for 40 mm thick PCC 1:2:4 type B1 (using 20 mm graded aggregate) as in floor finishing even and smooth with using extra cement and making impression of expanded metal, whilst concrete making good as per existing surface etc complete all as specified and directed.
Supply and laying steel water tubing medium grade of following bore fixed with wall/laid in floor with and including all GI fittings as required at site complete all as specified and directed.
(a) 50 mm bore
(b) 25 mm bore
(c) 20 mm bore
(d) 15 mm bore
S&F gun metal iron gate valve with iron wheel head, screwed both ends for iron pipe, ISI marked, complete all as specified of the following sizes including dismantling the old unserviceable existing valve complete :-
(a) 50 mm bore
(b) 25 mm bore
(c) 20 mm bore
(d) 15 mm bore
S&F of 'D' Joint of following bore complete all as specified and directed.
(a) 80 mm bore
(b) 100 mm bore
(c) 150 mm bore
(d) 200 mm bore
M&L for repair/rectification of leakage/blockage to water supply distribution lines of following bore of GI tubing by necessary excavation, returning /filling as required , tightening of lose joints of union ,elbow, socket nipple as per site requirement including for replacement of GI union ,socket, nipple as required complete all as directed.
(a) 15mm bore to 20mm bore
(b) 25mm bore to 40mm bore
(c) 50mm bore
M&L for dewatering complete trenches manually for repairing joints by cocking and inserting spurn yarn and Run lead joint, making good/ leakless the existing joint including necessary excavation and earth work like returning, filling etc for pipes of following bore complete all as directed.
(a) 80 mm bore
(b) 100 mm bore
(c) 150 mm bore
(d) 200 mm bore
M&L for dewatering complete trenches,Repair/rectification of leakage and blockageof PPR pipes manually repairing joints by inserting proper accessories and fittings of PPR pipes making good/ leakless the existing joint including necessary excavation and earth work like returning, filling etc for pipes of following bore complete all as directed.
(a) 110 mm bore
(b) 90 mm bore
(c) 75mm bore
Supply and fixing DI fittings for Socket pipe, DI Bends, connecting pieces, bell mouth pieces, tapers, tee pieces of one end flanged and other end spigot or socket upto 150 mm bore complete all as specified and directed.
S&F of Non Return Valve of following sizes at various pump houses complete as specified and directed.
(a) 150 mm bore
(b) 200 mm bore
(c) 100 mm bore
M&L for provision of new wash out points by proper cutting and screwing of existing DI/CI/GI pipe fixing reducer tee of suitable size, supplying and fixing, Jointing, testing CI sluice valve of following size by fixing 02 Nos at each wash out point with flanged ends including necessary mountings nuts, bolts washers and packing fibers gasket on both end and making pit chamber including iron frame cover 3.15 mm thick with locking arrangements complete all as specified and directed.
(a) 150 mm bore pipe
(b) 100 mm bore pipe
(c) 80 mm bore pipe
S&F in replacement of Bib tap of PVC 15 mm bore complete
S&F in repair sluice valve class PN-1.6 heavy duty flanged ends drilled ISI marked confirming to IS: 14846 suitable for 150 mm bore pipe, wheel operated (Handle) with high tensile stainless steel spindle, including nuts, bolts and jointing with jointing materials etc. complete including taking out old existing unservicable sluice valve including making arrangement for safe working all as specified and directed. Make: BIR, KIRLOSKAR ,Kartar or Equivalent as approved by GE.
S&F in repair sluice valve class PN-1.6 heavy duty flanged ends drilled ISI marked confirming to IS: 14846 suitable for 100 mm bore pipe, wheel operated (Handle) with high tensile stainless steel spindle, including nuts, bolts and jointing with jointing materials etc. complete including taking out old existing unservicable sluice valve including making arrangement for safe working all as specified and directed. Make: BIR, KIRLOSKAR or Equivalent as approved by GE.
M&L for repair sluice valve for 80 mm to 200 mm bore , high tensile stainless steel spindle, including nuts, bolts and gas kit ,glands and refixing after repair etc. and Dismantling and taking out sluice valve any size complete all as specified and directed.
Supply, installation, Commissioning and testing LT Busbar chamber, size of 600x 600x400 mm for 3 phase, 6 wire, 415 Volts, AC, 50 Hz supply, Outdoor cubical type, dust and vermin proof, pedestal mounting type suitable for Outdoor applications having suitable shape / size canopy on top, made out of 3.15 mm thick MS sheet with using 25mm x 25mm x 5mm angle iron frame and supports, duly finished with powder coated using two coats of synthetic enamel paint of approved colour over a coat of red oxide primer all over steel surfaces complete with separate compartment of suitable shape and size with shutter and locking arrangement and including PCC work for fixing panel legs and bus bar of Copper conductor suitable shape and size, 6 No of 200 amps rating including taking out end connectinons of the existing cables and fixing the cable with the panel using new lugs and glands of suitable size and Dismantling and taking out old U/S LT Busbar chamber and.
Supply & laying/fixing Floor & Trench,3 layered (outer green coloured UV stabilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded PP-R (polypropylene Random Co-Polymer) pipes, ISI marked including plain PP-R fittings and brass threaded PP-R fittings such as flanges, elbow, bend, sockets, tee etc. as required at site and testing of joints including taking up and down PP-R and PVC pipe and connections, of any bore of pipes complete all as specified and as directed of following size
(a) PN-16, 75mm OD (SDR– 7.4)
(b) PN-16 pipe, 90mm OD (SDR – 7.4)
S&F in replacement PPR gate valve (brass insert) of size 75 mm bore including connection and testing complete all as directed.
S&F in replacement PPR gate valve (brass insert) of size 90 mm bore including connection and testing complete all as directed.
M & L for construction of brick masonry valve pit of size 90x90x90cm (internal dimension) one brick thick wall built in CM (1:4) on 100mm thick PCC (1:4:8) type D2 (using 40mm graded crushed stone aggregate) as in foundation, and 15mm thick rendering in cement mortar (1:4) both externally and internally, external plaster shall be up to 15cm below GL, providing valve pit cover made of 3.15mm thick MS sheet/plate, including provision of hinges, handle and locking arrangement including 40 X 40 X 5mm angle iron frame fixed on top of valve pit by means of MS hold fast 40x5mm and 150mm long, embedded in PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) including two coats of anti-corrosive paint over a coat of red oxide zinc Chrome primer and necessary earth work in soft/loose soil including demolition of old unserviceable existing valve pit & pit cover complete all as specified & directed.
M&L for screwing existing steel tubing of bore 40/50mm in position for alterations or additions (or lengthening screw on pipe to form connector) complete all as specified and as directed.
M&L for screwing existing steel tubing of bore 20 mm in position for alterations or additions (or lengthening screw on pipe to form connector) complete all as specified and as directed.
M&L for running welding in any position as and where directed n.exc 6mm gitrh (thickness of metal to be welded) complete all as specified and as directed.
Taking up cast iron/ PVC / HDPEwater mains of following bore of pipes (including all fittings) with spigot and socket ends and lead joints including burning out joints and recovering lead. 100 mm 150 mm bore
Supply and laying of 150 mm bore centrifugally cast (Spun) ductile iron pressure pipe with spigot & socket end, class K-9 in any length laid in trenches, conforming to IS-8329/2000 with cement mortar lining with and including rubber gasket jointing conforming to IS-15382/tyton joint complete with all fittings e.g Tee, Bends etc all as specified and directed.
All as per item No 84 here in before but for 100 mm bore complete all as specified and directed.
M&L for run lead joint Spigot and socketed pipes and fittings, for the following size of pipe complete all as specified
(a) 80mm bore
(b) 100mm bore
(c) 150 mm bore
M&L for preparation of old concrete / plastered surfaces by scrapping, brooming etc and applying two coats of exterior weather proof acrylic based anti-fungal paint (100% acrylic) smooth emulsion with silicon additives that offer anti alge high performance exterior wall finish with 4 years of performance warranty by manufacturer and certified by paint manufacturer and accessories over dome, wall, columns, beams including all pipe lines etc of overhead reservoir using scaffolding & necessary safety precaution complete all as specified and directed for the following RCC over head reservoir:- (a) RCC overhead reservoir 100000/50000/25000 gallon capacity, 50 to 60 feet staging. Note :- Colour status shall be as under :- (i) Rising main - Blue colour. (ii) Delivery main - Green colour. (iii) Washout main - Red colour. (iv) Overflow main - Yellow colour.
Making connection of PP-R distribution branches 50 to 75 with PP-R main of following size by providing and fixing tee including cutting and making fusion joint etc complete all as specified and directed.
Making connection of PP-R distribution branches 16 to 40 with PP-R main of following size by providing and fixing tee including cutting and making fusion joint etc complete all as specified and directed.
Making connection of PP-R distribution branches 75 to 110 with PP-R main of following size by providing and fixing tee including cutting and making fusion joint etc complete all as specified and directed.
S&F in replacement cast iron medium pressure Air Release Valve of following sizes complete all as specified and directed for.
(a) 150 mm bore
(b) 100 mm bore.
S&F in replacement Pneumatic Actuator valve of size 80mm bore as per site requirement complete all as specified and as directed.
S&F in replacement foot valve 100 mm all as specified and as directed.
S& F in replacement submersible pump & motor electric driven 415 Volts, TP suitable for 200/250 mm dia bore well casing pipe of size 200/250 mm supply complete of 41 HP all as specified and directed.
Taking down the Unseviceable LT panel installed at PH and replacement with new one CPRI approved with following parts including panel board Wall mounted LT panel board indoor type of size 1200 x 1200 x400 mm with sheet CRCA sheet of 2 mm thickness comprising of the following :- ( a) 3 pole power contactor type ML 4 suitable for operation on,440 Volts, AC, 50 Hz -03 Nos (b) over load protection relay with relay range 45-75A suitable for operation on 3 phase, 415 V -01 Nos (c) voltmeter three phase anologue type class 1 voltage range 0-500 V flush mounting 96x96mm (d) ammeter three phase anologue type 5A class 1 of range 0-200 A flush mounting 96x96mm inculding CT 200/5 (e) MCCB 125 A capacity 3 pole for 415V -01 Nos (f) Supply and fix in repair MCCB 200 A capacity 4 pole for 415V -01Nos (g) indicating lamp on all 3 phases R Y B -01 set (h) PVC insulated multistranded copper conductor single core cable 4 sq mm (Nominal cross sectional area) as per site requirement including suitable size of copper lugs etc all as specified and directed-01 Job (j) single phase preventer direct mounting type with relay range 28-40 A 230 Volts suitable for electric motor of water supply installation-01 No (k) Electronic timer type ST 100 suitable for operation on 240/360/415 volts 50 Hz for 3-10 Sec-01 Nos. (l) Painting complete panel board with one coat of silver inside and outside -01 Job
Disconnecting, taking out and removing old existing unserviceable underground, LT cable of any description and in any position complete including taking down protection pipe,PCC Cover/Bricks etc all as specified and directed by the Engineer-in-Charge for the any sizes
Supply, laying, jointing and testing XLPE cable, PVC insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade of any description and any make laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes :-
(a) 70 Sqmm 3.5 core
(b) 95 Sqmm 3.5 core
(c) 120 Sqmm 3.5 core
Excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope / gradient for laying cables/ pipes etc. all as specified and directed including removing cable protection PCC covers/ bricks & stacking serviceable covers / bricks for reuse and disposal of unserviceable covers within 50 m all as specified and directed. Note : Excavation shall be made carefully in order to avoid damage of existing cables and protection covers.
Returning, filling in including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed & tested complete all as specified and directed
Removal of surplus excavated soil exc. 50 mtr but n. exc. 250 mtr distance and depositing where directed at a level not exceeding 1.5 M above the starting point etc complete all as directed.
Supply and laying new dry river sand laid in trenches 8.0cm below the cable and 15cm above the cable and gently punned to 18.0cm as cable cushioning and covering complete all as specified and directed. (Note:- Only punned 18 CM thick sand cushioning shall be measured and paid)
Supply, installation, commissioning and testing in replacement of APFC panel of capacity 40 KVAR (20 KVAR X1,10 KVAR X 1,5 KVAR X 2) powder coated factory made outdoor type of suitable size made of CRCA sheet made from min 3.15 mm thick sheet CPRI manufactures with countersunk holes at bottom for base mounting brackets and sheet steel gland plates for cable entry, formed gasket arround doors, with provision of Lock inserts, earthing straps, door stay complete panel prewired with suitable size of copper cable not less than 2.5 sqmm and grouted in ground by using angle iron frame of size 50mm x 50mm x 6mm, PCC (1:2:4) type C-1 with 20mm graded stone aggregate.Panel comprising with following:- (a) Incoming MCCB 4 pole 100 Amp 16 KA alongwith Spreader terminals with adjustable thermal setting – 01 Nos (b) Multifunctional 4 in 1 meter like Amp,Voltage, frequency, powerfactor as per capacity of panel = 01 No. (c) Phase Indicator Lamp RYB with sheds LED Type - 01 Set of three (d) Capacitor MPPH type with suitable size 3 phase power contactors and with individual 3 pole 415 volt MCBs of suitable capacity including indication lamp of each capacitor. (e) Microprocessor based 3 phase current transformer sencing relay 4 stage = 01 No( for operating of capacitor bank) (f) Auto/Manually switch of capacitor bank (g) PCC 1:2:4 for installation of panel
Supply and fixing all in one solar LED street light IP66 with high efficiency mono crystaline solar panel PV module not less than 12V, 20W lithium ferro phosphate battery with in-built BMS technology, capacity 12.8V, 10.5 Ah high efficiency LED 100LM/W, MPPT solar charge controller and aluminium extruded body & is specially programmed to automatically control the dimming and brightness of light, which increase the backup time and minimum 10 Hrs backup.
Supply and fixing of display board of outer size 4.1X1.0 mtr made out of stainless steel of thickness 2 mm at square pipe 8X8 cm with back support of 40X5 mm stainless steel plate fitted at 3 fet interval of board backside including writing name of installation and unit as directed with reflecting tape of any colour as directed alongwith legs of size 8X8 cm square pipe upto the height of 14 feet from ground with foundation with stand 26 km/hr air velocity alongwith 02 nos of spot light at suitable place as directed with point wiring as directed.
Supply and fixing aesthetically designed decorative banner arm single, enhancing the appearance of the pole including pole of size 50 mm dia of 03 mtr hight fitted in PCC (1:2:4) including foundation and coping of size 1' X 1' X 3' and banner of desired material including supportive rod on upper and bottom side of banner and fixed with clamp on arm and with writing description all as specified and directed by Engr-in-Charge.
sunder and company (BID ID -3086389)
Maa Bhawani Construction (BID ID -3093712)
prabhave traders (BID ID -3087172)
HASINI ENTERPRISES (BID ID -3080975)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .