Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹23,000
Closing Date
27 Jul 2026, 6:00 pmDue tomorrow
GE ARMY GANDHINAGAR
GE ARMY GANDHINAGAR PO BSF CAMPUS GANDHINAGAR 382045
REPAIR AND MAINT OF VARIOUS SUMMER AND COOLING APPLIANCES AT OTM AND CENTRAL INSTITUTE AT MIL STN DHRANGADHRA
2026_MES_775288_1
GE(A)/GNR/TOKEN/67 of 2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
MIL STN DHRANGADHRA
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE ARMY GANDHINAGAR
₹23,000
Yes
27 Jul 2026
29 Jun 2026
3 Aug 2026
29 Jun 2026
27 Jul 2026
13 Jul 2026
29 Jun 2026 - 11 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down Ceiling fan of Sweep, any make, 1200/1400/1500mm, 230 volts of any make & size from any height of the building for finding out the defects such as Capacitor, winding, bearing etc and servicing / overhauling the same, including replacing minor accessories like locking pins, rubber real, PVC sleeve, greasing, clamps, etc as required, and fixing back the same in its original position along with necessary fixing materials such as nut, bolts and washers etc all as specified and as directed by Engineer in charge.
Note:- The spares referred / mentioned here-In- after shall only be paid under supply only. Rest of the spares required for functioning of the fans is deemed to be included in the unit rate quoted. The labour element required for replacing the spares listed here-in-after shall be deemed to included in the unit rate quoted. | 685 | EACH | - | - |
| 2 | Taking down Exhaust fans heavy duty of Sweep 225 to 450mm, 230 volts of any make & size from walls/ trusts for finding out the defects such as Capacitor, winding, bearing etc and servicing/ overhauling the same and fixing back the same in its original position along with necessary fixing materials such as nut, bolts and washers etc all as specified and as directed by Engineer in charge.
Note :- The spares referred / mentioned here-In- after shall only be paid under supply only. Rest of the spares required for functioning of the fans is deemed to be included in the unit rate quoted. The labour element required for replacing the spares listed here-in-after shall be deemed to included in the unit rate quoted. | 55 | EACH | - | - |
| 3 | Taking down Wall mounted/Pedestal fans of Sweep 300 to 450mm, 230 volts of any make & size from walls/floors for finding out the defects such as Capacitor, winding, bearing etc and servicing/ overhauling the same and fixing back the same in its original position along with necessary fixing materials such as nut, bolts and washers etc all as specified and as directed by Engineer in charge..
Note for Item Sl No 1 to 3 : (i). Cost of Bearing, Capacitor and rewinding will be measured and paid separately under the respective item of the Schedule. (ii) Labour element for removing and refixing the Bearing and removing and rewinding the winding will be measured in the respective of the schedule. (iii) Misc items such as nut & bolts, Rubber bush & locking pin etc required for satisfactory completion of job deemed to be inclusive of the unit rate. | 10 | EACH | - | - |
| 4 | Rewinding of fan motor of any make Sweep 1200 and rewinding the same with single strand fine enamel copper conductor of same guage weight and turns and keeping the windings into hot air oven till the moisture evaporates including testing and commissioning complete. Make :Devi Dayal/Atlas/BPL
Note : (1) All the misc items such as impregranted paper, warnising, cotton tape and other misc items required for satisfactory completion of job deemed to be included in the unit rate.
(2) The above repairs are considered to meet the anticipated requirement if any and based on the site requirement the scope will be handed over to the Contractor. | 375 | EACH JOB | - | - |
| 5 | All as item No 04 here in above but for Ceiling fan1400/1500mm sweep. | 35 | EACH JOB | - | - |
| 6 | All as item No 04 here in above but for Exhaust fan 225 to 300mm sweep. | 25 | EACH JOB | - | - |
| 7 | All as item No 04 here in above but for Exhaust fan 350 t0 450mm sweep. | 25 | EACH JOB | - | - |
| 8 | All as item No 04 here in above but for Pedestal / Wall mounted fan upto 450mm sweep. | 6 | EACH JOB | - | - |
| 9 | S&f of Capacitor 2.5/3.15 MFD, AC 250 volts capacity all as directed. Make :Usha / Bajaj / Tibco / CG | 542 | EACH | - | - |
| 10 | Supply only Ball bearing suitable for 1200/1400/1500 mm sweep ceiling fans. Make: NBC/Tata | 350 | EACH | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.36 MB
BOQ_868155.xls
BOQ • 4.48 MB
TenderDocuments.pdf
Tender Documents • 0.80 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].