Providing Service Connection Internal Electrification to Newly Constructed 250 LPH RO Plant Room near Wet Canteen at BSF Campus Yelahanka under STC BSF Bengaluru
2026_BSF_923179_1
01/NIQ/STCBSF/ENGG(E)/2026-27
Open Tender
Electrical Works
Item Rate
15 days
IG STC BSF Yelahanka Bglr
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
Exempted
21 Aug 2026
21 Aug 2026
3 Sept 2026
21 Aug 2026
1 Sept 2026
21 Aug 2026
21 Aug 2026 - 1 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.(i) Group C | 4 | Point | 10 | ₹40 |
| 2 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt).Supplying, Installation, Testing & Commissioning ofLED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till lifeends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumptionshould not more than the specified rating andFixture shall be of relevant BIS standard.Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management:
heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium
Body (Thickness > 1.20 mm)
(i) 18- 22 Watt . Crompton/ Havells/Bajaj make | 4 | Each | 10 | ₹40 |
| 3 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
(i) 2 X 25 sq. mm (22mm) | 2 | Each | 10 | ₹20 |
| 4 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. | 45 | mtr | 10 | ₹450 |
| 5 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. | 4 | Each | 11 | ₹44 |
| 6 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
(i) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire | 2.8 | mtr | 12 | ₹33.6 |
| 6.01 | (ii) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | 1.75 | mtr | 13 | ₹22.75 |
| 7 | Supplying and fixing following way, single pole andneutral, sheet steel, MCB distribution board, 240 V,on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (i) 6 way , Double door . Indoa asian make/ Havells/ /Legrand make | 1 | Each | 14 | ₹14 |
| 8 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(i)Single pole. Indoasian make/ Havells/ /Legrand make | 3 | Each | 15 | ₹45 |
| 9 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.(i) 40 A. Indoasian make/ Havells/ /Legrand make | 1 | Each | 16 | ₹16 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.29 MB
BOQ_970119.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].