Loading…
Loading…
59 results • Latest
Annual repair and maintenance (Elect) Residential building and Non-Residential buildings at BSF Campus Jalandhar under FTR HQ BSF PB 2025-26 (SH-Replacement of existing poles and light fittings)
Providing, installing, testing and commissioning of decorative Die cast aluminum ornamental street light pole of approx. 2.9 m height with three nos. decorative curved arms, complete with antique finish / powder coating as approved. Pole to include base plate, foundation bolts, internal wiring from terminal box to lanterns, suitable for mounting 40 watt warm LED decorative lantern fittings and all accessories required for proper and safe operation, complete etc as required
PROVIDING AND FIXING OF INDOOR LED LUMINAIRES FOR PROVISIONING COMPLEX OF FTR HQ BSF NB KADAMTALA.
Providing and fixing of 36 watt 2 x 2 feet Square surface/ recessed mounted ultra slim LED professional fitting, Min 100 lm/w for operation on 240 Volt 50 Hz AC supply complete with electronic driver & all accessories etc as required. (Make Havells /Crompton / Philips/ Jaquar).
PROVIDING AND INSTALLATION OF CEILING FANS AGAINST CONDEMNATION AT VARIOUS PLACES OF COMPOSITE HOSPITAL BUILDING, BSF CAMPUS KADAMTALA
Providing and fixing of 1200 mm sweep, BEE 5 star rated, ceiling fan with BLDC Motor, 30 cm long down rod, and all remaining accessories, safety pin, nut bolts, washers, suitable for 230 V, 50 Hz, single phase AC Supply including wiring the down rods of standard length (upto 30 cm) with 1.5 sqmm FRLS PVC insulated, copper conductor, single core cable & providing and fixing phenolic laminated sheet cover on the fan box etc as required. (Havells / Usha /Orient / Crompton make)
Cleaning of over head tank under ground sump and all water storage RCC tank of residential Non residential building Gully trap chamber and Choked sewer line at BSF Campus Gandhinagar under Ftr HQ BSF Gujarat
Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in- harge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account)
UPGRADATION OF TOILET BLOCK AT BOP MANDVI OF 153 BN BSF UNDER SHQ BSF BHUJ.
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
CONSTRUCTION OF TYPE-IV/06 NOS RESIDENTIAL QTRS FOR 50 BEDDED COMPOSITE HOSPITAL AT CAMPUS SALBAGAN AGARTALA. (SH CONSULTANCY SERVICES FOR SOIL INVESTIGATION, PREPARATION OF DETAILED ESTIMATE , PREPARATION OF STRUCTURAL AND WORKING DRAWING)
Soil investigation by boring up to 15.00 mtrs depth in all type of soil/rock strata at various location, performing SPT at 1.50 mtr interval as per IS 2131-1981. Collection of disturbed/ undisturbed soil samples of different strata of soil as per direction of Engineering-in-Charge. Visual and engineering classification sieve analysis and hydrometer analysis, Liquid, plastic and shrinkage limits, specific gravity, chemical analysis and free swell index determination laboratory test to be performed on disturbed and undisturbed soil sample. Bulk density, moisture content, direct shear test, unconfined compression test one dimensional consolidation test and triaxial shear test (un-consolidation, undrained, consolidation- undrained test with measurement of pore water pressure, consolidated drained) laboratory test to performed on undisturbed soil sample. Visual classification water- absorption slope durability, porosity and density, unconfirmed compression test (Both at saturated and in situ water-contest), rock modulus of elasticity and Poisson's ration, Brazilian tensile- strength and point load-strength index laboratory test to be performed on rock samples. Submission of all test reports along with safe bearing capacity of Soil at different levels- in triplicate.