AC(Electrical)
SHQ BSF Krishnanagar
Providing three phase electric service connection and Air conditioners for X-ray room and CR system room at Combined Hospital Seemanagar campus under SHQ BSF Krishnanagar
2026_BSF_935280_1
39/SHQ-KNR/AE(E)/NIT/2026-27
Open Tender
Electrical Works
Percentage
60 days
Seemanagar campus
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹3,219
21 Nov 2026
21 Nov 2026
1 Dec 2026
21 Nov 2026
30 Nov 2026
21 Nov 2026
21 Nov 2026 - 30 Nov 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing and fixing 100 A rating 30 KA breaking capacity, four pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc as required. | 1 | Each | 8,127 | ₹8,127 |
| 2 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (i) 4 x 16 sqmm + 1 x 10 sqmm | 20 | Mtr | 2,312 | ₹46,240 |
| 3 | Supplying and fixing MCCB enclosure box suitable for 100 Amp four pole MCCB on surface as per direction of engg in charge. | 1 | Each | 2,684 | ₹2,684 |
| 4 | Providing and fixing 100 Amp 4 way busbar chamber 415 V, on surface/ recess, including connections etc. as required. | 1 | Each | 10,992 | ₹10,992 |
| 5Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Outdoor unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, i/c suitable voltage stabilizer for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll /rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 °C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS: 1391 Part II 2023. The system shall be able to operate up to 50 °C (outdoor ambient temperature). | |||||
| 5.1 | 1 Ton inverter type cooling only | 1 | Each | 44,610 | ₹44,610 |
| 5.2 | 1.5 Ton inverter type cooling only | 1 | Each | 47,570 | ₹47,570 |
| 6 | Add cost index @ 9% on total DSR item | 1 | Each | 731.43 | ₹731.43 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.72 MB
BOQ_982819.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .