Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.4 LAccepted-AOC | ₹14.4 L Quoted ₹14.5 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹15.8 L+₹1.4 L (9.39%)Rejected-Finance | ₹15.8 L+₹1.4 L (9.39%) | L2 | Rejected-Finance Rejected due to bidder is not L1 |
Tender Value
₹14.6 L
EMD Value
₹29,100
Closing Date
4 Jul 2020, 6:00 pmClosed
Sh K Ramesh Babu, IDSE
Office of the GE (Army) Camp Hanuman, Ahmedabad - 380 004
SPL REPAIR TO BLDG NO T 123 AND PROVN OF KOTA STONE FLOORING AT VERANDAH OF BLDG NO P 08 OF 11 INF DIV SIG REGT AREA AT AHMEDABAD CANTT
2020_MES_349650_1
8104/E8
Open Tender
Civil Works
Item Rate
180 days
GE (Army) Ahmedabad
AS PER NIT
9 documents required · 9 mandatory
₹500
GE (Army) Ahmedabad
₹29,100
Yes
19 Aug 2020
4 Jun 2020
6 Jul 2020
4 Jun 2020
4 Jul 2020
19 Jun 2020
4 Jun 2020 - 19 Jun 2020
Amount
Taking down chowkats or frame with shutters ( without taking off shutters from the frame) n.exc 1.5 sqm each complete all as specified and directed.
Taking down chowkats or frame with shutters (without taking off shutters from the frame) exc 1.5 sqm and n exc 4.0 sqm each complete all as specified and directed.
S&F mild steel angle iron work as in doors frames, conforming to Fe-410-0 complete all as specified and directed.
S&F 2nd hard wood factory made 35mm thick glazed, and skeleton shutters open rebated & prepared to receive, glass, gauge etc. divided into squares with plain chamfered or rounded mitred and rebated any numbers and size of members of shutters as specifed in SSR Part I, Section 8, clause 8.24(a); supllied and fitted to chowkahts complete all as specified and directed.
S&F 2nd class hard wood factory made plain framed panelled door shutters 35mm thick (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both sides. The size of rail and stiles as per IS:1003 (Part I), Klin seasoned and chemically pressure treated complete all as specified and directed.
S&F Stainless steel wire cloth 0.36mm normal dia of wire and average width of aparture 1.40mm and fixed with tinned tacks or Stainless steel wire stapples complete all as specified and directed.
S&F butt hinges 100mm size medium weight cold rolled mild steel complete all as specified and directed.
M&L for 150mm long extructed aluminium handle fabricated type complete all as specified and directed.
S&F Aluminium anodised barrel tower bolt of extruded section 150 mm size complete all as specified and directed.
S&F aluminium alloy anodised sliding door bolt with hasp and stapple ( bolt type) and fixing clips of sheet cast or extruded section with fixing bolts and sliding bolt of extruded section 300mm length & dia not less than 12mm with & including 6 Nos of bolts complete all as specified and directed.
M&L for 18-20mm thick Granite (of any type) work (tablee rubbed and polished) in steps, jambs, pillars, windowcills,cooking platforms and like in cement mortar (1:4) including pointing in white cment (1:2) using marble dust with admixture of pigment to match with shade complete all as specified and directed.
M & L for machine cut kota stone slab size as in flooring, stair case landing. treads of steps etc, 20-25mm thick over cement screed bed laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified including 15mm thick screed bed or bedding in cement mortar 1:6. all as specified nd directed
M & L for machine cut kota stone slab size as in skirting, dado, vertical surfaces etc, 20-25mm thick over cement screed bed laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing incl using backing coat 10mm thick in cement mortar 1:4. complete all as specified and directed.
M&L for 25mm thick cement concrete 1:2:4 type B0, using 12.5mm thick stone aggt for laying floor finishes complete all as speciifed and directed.
M&L for Non Skid ceramic coloured tiles 7mm to 8mm thick, (square or rectangular) area of each tile exc 0.18 Sqm but n. exc 0.38 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15mm thick screed bed in CM 1:6 complete all as specified and directed.
All as per item No 15 above but on verticle surfaces incl 10 mm thick screed bed in CM 1:4 complete all as specified and directed.
Dismantling asbestos cement (corrugated or semi corrugated, etc)sheets in roof covering complete all as specified.
S & F prepainted galvalume aluminium zinc coating GI base corrugated steel sheet 0.60 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / clading to wall, fixed with self tapping screws complete all as specified and directed.(Note : Corrugation colour and shape of sheet shall be approved by GE)
S & F prepainted galvalume aluminium zinc coating GI base plain steel sheet 0.60 mm thick of any colour having tensile strength of 550 Mpa as in ridge, fixed with self tapping screws complete all as specified and directed.
Dismantling timber scantling 40Sqcm and over in section in any position in unframed work as in rafters, purlins etc
S&F mild rolled steel straps in joist, angle ,channel as in purlins, rafters etc conforming to fe410 w complete all as specified and directed.
Demolition of cement concrete unreinforced of Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed.
Taking down cement or lime plaster of any description from stone or brick walls etc including raking out joints, hacking for key scrubbing down with water and disposing off the rubbish complete all as specified and directed.
M&L for 15mm thick rendering on fair faces of brick/ concrete surfaces in CM (1:4) finished even and fair without using extra cement complete all as specified and directed.
M&L for 10 mm thick rendering on surfaces other than fair faces of brick/concrete surfaces in CM (1:6) and finished even and smooth without using extra cement complete all as specified and directed.
Supply only Integral waterproofing compound.
Demolition of Brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L for brick work with sub class 'B' bricks built in CM (1:6) straight or curved on plan & exc 6 m mean radius with old size bricks complete all as specified and directed.
M&L Half brick thick brick work with sub class B brick straight or curved on plan exc 6m mean radius built in CM (1:4) complete all as specified
M&L for cement concrete (1:3:6) type C-1 using 20mm graded stone aggregate 75mm thick as in plinth protection including necessary form work and finishing surface even and smooth w/o using extra cement including bitumen joints complete all as specified and directed.
M&L cement concrete (1:3:6) type C1 (20mm graded aggregate) as kerbs, coping, apex stones, bed plates et incl necessary formwork Complete all as specified and directed.
S & F mild steel bars conforming to Fe 290 Gde E-165 as in guard bars or similar works including welding etc complete all as specified.
S&F steel window with side hung shutters including box type hinges with steel handles and steel peg stay complete with glazing bars dove-tailed or welded complete including one coat of shop coat of primer complete all as specified and directed.
All as per item no. 34 above but without glazing bar complete all as specified & directed.
S&F anodised aluminum windows/Ventilators /III track window complete and any pattern of medium grade sections weighing 0.55 Kg/RM including necessary jointing cleats, glazing clips, rubber gasket, aluminium snap beading, screws, aluminium frame and fittings including 5 mm thick tinted sheet glass and including locking arrangements and all fittings all as per manufacturers instructions complete all as specified and directed.
Dismantling wall and ceiling boards any thickness including cover fillets complete all as specified and directed.
S&F 4mm thick coloured textured designer ceiling board (Everest) of size 595X595 mm fixing with screws/clips including Tee grid suspension system of size 600 mm x600 mm type-1 made out of roll framed hot dipped galvanised steel zinc coated of not less than 120 gm/sqm ,main runner shall be 0.3 mm thick of section 24 mmX33 mm cross runner 0.3 mm thickof section 24 mmx25 mm,wall angle shall be 0.63 mm thick of section 24 mmx24 mm grid shall be suspended by 4 mm dia adjustable quick fit hanger rod ,system exposed portion shall be pre painted polyster coated in off white/white in colour complete with material,fixing, jointing etc complete all as specified and directed. ( Make:- METROC or METACIL or any other equivalent make as approved by GE.
S&F mild steel rolled sections as in framing for fixing boards in ceiling and the like fixed with angle cleats and connecting plates of grade Fe-410-S complete all as specified and directed.
M&L for 6mm thick AC plain building boards fixed to MS frame as in ceiling all as directed by Engr-in-Charge
M&L for preparation of new plastered surfaces on walls and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed.
M&L for prepartion of new plastered surfaces on walls and applying two coats of cement based paint on over one coat of primer on walls complete all as specified and directed by the Engr-in-Charge
M&L for preparation of new steel surfaces exc 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified.
M&L Preparation of old surfaces of wood or wood based materials of any description not other wise described, over 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and as directed by EIC.
M&L for preparation of New surfaces of wood or wood based materials of any description not other wise described, over 10cm width or girth and applying Two coat of synthetic enamel paint, incl one coat Primer complete all as specified and directed.
M&L for complete removal of existing treatment and applying two coats cement based paint on over one coat of Primer on walls complete all as specified and directed by the Engr-in-Charge
M&L complete removal of existing treatement and applying two coats of oil bound distemper over a coat of primer, in old plastered or un-plastered surfaces on walls complere all as specified and directed by Engr-in-Charge
M & L applying 2 mm thick wall care putty on wall for smoothning a surface complete all as specified and directed.
M&L for roughening surfaces by picking, sweeping clean and washing down with water to remove dust and brushing neat cement slurry with 3 kg of cement per sqm complete.
M&L 50mm thick PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in sub base complete all as specified and directed.
M&L screed bed or bedding layer of mortar 20mm thick in CM 1:6 for laying floor finishes complete all as specified and directed.
Material & labour for machine cut kota stone slab size as in flooring, stair case landing treads of steps, 18-22mm thick over cement screed bed laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including 20mm thick screed bed or bedding in cement mortar 1:4 complete all as specified and directed.
Material & labour for machine cut kota stone slab size as in skirting, dado, vertical surfaces etc, 18-22mm thick over cement screed bed laid and jointed with grey cement sluryy mixed with pigment to match the shade of the slab including rubbing and polishing including backing coat 15mm thick backing coat in cement mortar 1:3 complete all as specified.
Taking down carefully surface aluminium or copper point wiring with PVC casing-caping (light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc and making good disturbed surfaces complete.
Point wiring with 1100 volts grade PVC insulated FRLSH multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal boxes of thickness not less than 1.2 mm covered with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets, fan regulators complete for the following :-
One light point controlled by one switch.
One fan point controlled by one switch.
One socket outlet 6 amp controlled by one switch on the same board with other switches.
One socket outlet 6 amp controlled by one switch on indepdendent board.
Point wiring with 1100 volts grade PVC insulated FRLSH multistranded copper conductor cable 2.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 2.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal box of thickness not less than 1.2 mm covered with 3 mm thick phenolic laminated white sheet cover for one 16 amp socket outlet controlled by one switch on independent board complete.
S&F switch piano flush button single pole one way 6 amp complete.
S&F switch piano flush button single pole one way 16 amp complete.
S&F socket outlet 2 in 1, 3 pin 6 & 16 amp flush type complete.
S&F socket outlet 2 in 1, 2 & 3 pin, 6 amp, flush type complete.
S&F hum free electronic step fan regulator 120 - 280 volts of 100 watt capacity including connecting up complete.
S&F ceiling rose 6 amp, 3 plates polycarbonate body complete.
M&L for submain wiring alongwith earth continuity conductor with PVC insulated FRLSH multistranded copper conductor cable (Phase - Red, Neutral - Black, Earth - Green) drawing into and including concealed rigid non metallic PVC conduit, medium grade, ISI marked ivory colour along with accessories of following nominal sizes:-
2x4 sqmm + 1x4 sqmm earth continuity conductor in 20 mm dia conduit..
2x6 sqmm + 1x4 sqmm earth continuity conductor in 20 mm dia conduit..
S&F LED batten (1.2 m) made of Aluminium housing with a PC glossy diffuser duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficacy of 100+ lumens per watt and total power consumption not less than 20 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a color temperature of 6500K, CRI>80, THD < 10% and PF > 0.95 complete. Make : Philips cat ref no. ENDURALED BATTEN " BN 108C LED 20S PSU CDL WH " or Havells Lumiline plus as approved.
S&F In repair energy efficient recessed mounted LED luminaries suitable for for 2'x2' grid ceiling with flat diffuser and lumen output of 3300 lumens having constant current electronic driver duly connected with 0.5 sqmm white color PVC insulated & sheathed three core flexible multistranded copper conductor cable, complete all as specified and directed. Fittings shall be of philips cat ref no.SM335B LED 33-5000PSU OD WH or equivalent in Havells, Pluto Neo Panel 2x2 OR equivalent in Wipro as approved complete.
S&F LED bulkhead fitting 9 watt IP 66 & IK 09 with pressure diecast aluminum housing & polycarbonate diffuser duly prewired for connection with flexible multi stranded copper conductor cable as required all as per Philips cat ref no. WT202W LED6S CW PSU S1 PC or equivalent in Wipro or Bajaj or Havells as approved.
S&F MCB distribution board SPN, 240 volts, 8 ways powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required.
S&F MCBs as per load requirement 'C' series of breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of following ratings:-
Single pole 6 to 16 amp. Make - Legrand DX3 cat ref no. 408587 to 408592 or equivalent in Schneider or Hager as approved.
Double pole 32 amp. Make - Legrand DX3 cat ref no. 408636 or equivalent in Schneider or Hager as approved.
Taking down carefully aluminium or copper submain wiring with PVC surface conduit or casing caping and making good disturbed surfaces complete.
Taking down MCB distribution boards with incoming and outgoing controls any make, any capacity after disconnecting complete.
S&F galvanized unwelded pressed steel terminal boxes concealed in wall of thickness 1.2 mm covered with phenolic laminated white sheet cover 3 mm thick in renewal of wooden meter boards of size 250mm x 300mm x 60mm deep for fixing energy meters complete
S&F fully transparent meter box suitable for energy meter made of polycarbonate/ high grade engineering plastic to permit clear view of display and can be sealed in such way that the entire meter is accessible only after breaking the seal complete.
S&F Microprocessor based single phase 2 wire tamper proof electronic energy meter (Whole current) 10 - 60 amp, accuracy class 1.0 having optical communication port conforming to IS: 13779 housed in fully transparent TOP cover made of polycarbonate / high grade engineering plastic to permit clear view of display and indicator complete. Make - Secure icredit 350 or equivalent in L&T or HPL as approved.
DMA PROJECTS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .