Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.9 LAccepted-AOC CHAKKALAKKAL H KOTTAT P O | L1 | Accepted-AOC L1 | |
| 2 | L2₹24.9 L+₹2 L (8.72%)Rejected-Finance | L2 | Rejected-Finance L2 |
| Sl No | Description | Qty | Unit | BIJU JOSE L1 | P SQUARE ELECTRICIALS L2 |
|---|---|---|---|---|---|
| 1.00ELECTRICAL | |||||
| 1.00 | OD484135/2024-2025:Supply, conveyance, Installation, testing & commissioning of 82.5 KVA Diesel Generator set with integral acoustic enclosure as per CPCB-4 norms with srandared acessories as per technical details given below. 1. Engine : a) Make of Engine - cummins/kirloskar/leyland b) Type of Engine- Diesel Engine c) No. of Cylinders - As per manufactures standards. d) Method of Cooling - Water cooled with radiator. e) Aspiration Turbo charged after cooled. f) Design - Suitable for generating set operation 2.Standard accessories with Diesel Engine a) Fly wheel to suit flexible coupling b) Close Coupling c) Air cleaner d) Radiator with fan
provided with fan guard. e) Fuel Pump f) Mechnical governor g) Fuel filter h) Lubricating oil filter i) Exhaust silencer j) Exhaust Muffler k) Battery Charger/Generator 3. Engine Instrument Panel with the following items a) Starting switch with key or button 1 b) Lubricating oil pressure gauge. c) Water temperature gauge. d) RPM Indicator with hour meter e) Battery charging Ammeter 4. Safety Controls for Engine a) Trip for low lubricating
oil pressure b) Trip 2. Alternator make : Leroy Somers or Stanford" (5). Brushless alternator. (a). Make -Stamford /BHEL /Leroy somer. (b). Type - Self exited and self regulated.(c). Capacity -82.5 KVA/ 61.5 KW @0.8PF. (d). System of Voltage - 3 Phase, 415 V, 4 Wire system.(f). Speed - 1500
rpm.(g).Frequecncy -50 Hz.(h). Insulation - Class F/H.The alternator should confirm to IS4722/IS13365. Operation and service manual shall be provided. (6). Fuel Tank. Suitable sizefitted (built in type) inside the acoustic enclosure. (7). Battery. Suitable size fully charged batterywith leads and terminals of appropriate AH capacity as per Manufactures required including batterycharger. (8). Standard control panel. (a) 100A Pole MCCB Set at 70 A and stand by low setearth fault relay using suitable size neutral CT. (b). 1No multi function meter suitable for display of currentin 3Phases, voltage in 3Phases, frequency, power factor, KVA,
KVAh, KVAr, KVArh, KW etc. (c).1No separate KWH meter (d). Necessary measuring CTs of appropriate ratio and burdon for therequired meter.(e). Instrument fuse/MCB (f). Metallic DNB - 1No.(g). Solid state phase indication lamp for supply ON/OF with Fuse / MCB protection | 1 | set | 11,10,000 ₹11,10,000 Lowest | 13,10,000 ₹13,10,000 |
| 1.00 | 90.12.5.31:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 95 sq mm | 20 | metre | 745 ₹14,900 Lowest | 745 ₹14,900 Lowest |
| 1.00 | 90.12.7.31:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 95 sq mm | 20 | metre | 745 ₹14,900 Lowest | 745 ₹14,900 Lowest |
| 1.00 | 90.12.1.42:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 25 sq mm | 15 | metre | 620 ₹9,300 Lowest | 620 ₹9,300 Lowest |
| 1.00 | 90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size | 20 | metre | 300 ₹6,000 Lowest | 300 ₹6,000 Lowest |
| 1.01 | 90.12.10.4:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation77/63 mm or nearest size | 20 | metre | 330 ₹6,600 Lowest | 330 ₹6,600 Lowest |
| 1.01 | 90.12.41.31:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 4 sq mm with factory made clamp | 18 | metre | 390 ₹7,020 Lowest | 390 ₹7,020 Lowest |
| 1.01 | 90.12.5.38:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 4 sq mm | 20 | metre | 210 ₹4,200 Lowest | 210 ₹4,200 Lowest |
| 1.01 | 90.12.39.1:Supply & laying of one number PVC insulated and PVC sheathed armoured copper power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 4 sq mm | 10 | metre | 255 ₹2,550 Lowest | 255 ₹2,550 Lowest |
Tender Value
₹22.2 L
EMD Value
₹50,000
Closing Date
2 May 2025, 4:00 pmClosed
Executive Engineer Thrissur corporation
Executive Engineer Thrissur corporation
Thrissur Corporation - Ollur zonal - Supply and Installation of 82.5 KVA Diesel Generator Set at Zonal office Ollur -Supply and Installation of 82.5 KVA Diesel Generator Set-
2025_LSGD_761921_16
PW2-17409/18,5.5.25EE1
Open Tender
Civil Works - Roads
Item Rate
180 days
Thrissur corporation Office
Please refer Tender documents.
11 documents required · 11 mandatory
₹2,760
₹50,000
22 Apr 2026
26 Apr 2025
5 May 2025
26 Apr 2025
2 May 2025
26 Apr 2025
26 Apr 2025 - 30 Apr 2025
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1240119.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
NIT.pdf
Other Document • 0.03 MB
BOQ_1240119.xls
BOQ • 0.38 MB
SBD.pdf
Other Document • 1.63 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .