Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.8 LAccepted-AOC | ₹14.8 L | L1 | Accepted-AOC l1 |
| 2 | L2₹15.3 LRejected-Finance | ₹15.3 L | L2 | Rejected-Finance L2 |
Tender Value
₹15.0 L
EMD Value
₹37,382
Closing Date
12 Jan 2026, 1:00 pmClosed
Executive Engineer
Executive Engineer PH Division,Thiruvalla
MLA SDF Kuttanadu MLA Sri Thomas K Thomas RWSS to Nedumudy Construction of 200mm dia tubewell construction of new pump house and supply erection of suitable HP submersible pumpset in ward No 8 of Nedumudy Panchayath Pipeline Work
2025_KWA_824748_1
2nd RE Tender no.17/2025-26/EE/PH/TVLA
Open Tender
Civil Works - Water Works
180 days
nedumudy
Please refer Tender documents.
9 documents required · 9 mandatory
₹2,760
₹37,382
21 Feb 2026
3 Jan 2026
13 Jan 2026
3 Jan 2026
12 Jan 2026
3 Jan 2026
Amount
Construction of temporary pump house
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
50.2.26.1:Filling with contractor own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge.
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
50.6.1.7:Solid block masonry using pre cast solid blocks ( Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15 cm in : CM 1:6 ( 1 cement : 6 coarse sand ) etc complete
50.6.2.1:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete
50.2.25.1:Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge
4.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources)
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
12.1.3:Providing corrugate G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete ( up to any pitch in horizontal / vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.63 mm thick with zinc coating not less than 275 gm/m2
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
9.95.3:Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete:100x75x4 mm
9.97.3:Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:200x10 mm
50.9.15.1:Supplying and fixing 200 mm Aluminium aldrop
Electrical work-Electrification of pump house
OD160760/2024-2025:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface I recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper<br>conductor single core cable etc. as required- Group B.
OD160969/2024-2025:Providing and fixing 63Amps capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.
OD160970/2024-2025:Earthing with G.l. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate Jlaving locking arrangement and watering pipe etc. with charcoal/coke and salt as required
OD160971/2024-2025:Installation, testing and commissioning of pre-wired, fluorescent fitting I compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc.directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
OD160972/2024-2025:Supplying Fluorescent Lamp with all accessories
OD160973/2024-2025:Supplying and fixing metal box of 200 mm X 125 mm X 60 mm size (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
OD160974/2024-2025:Supplying and providing meter box and panel board for KSEB supply and providing necessary fuse unit and isolators for 3 phase supply as per the direction of departmental officers.
Supply,erection ,testing and commissioning of submersible pump set and Construction of Tube well
OD161247/2024-2025:Providing bleaching powder solution feeding unit for disinfection of water consisting of supplying and providing polyethylene water storage tank (ISI marked) with cover and suitable locking arrangement of capacity 500 Ltr, providing platform of size 1.25 M x 1.00 M for placing PVC tank by structural steel work riveted, bolted or welded in built up sections including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using ISA 75 x 75 x 6, providing 20 mm CPVC pipe connection for inlet water supply to tank from pumping main and out let supply from tank to bottom of tube well including providing two number ball valves in inlet line and one valve in outlet line and providing 50 mm CPVC pipe darin outlet in tank for scovring arrangement including providing 50 mm PVC ball, valve in drain pipe and making the unit functional for collecting water from pumping main and continuous feeding of bleaching powder solution to tube well etc complete including cost and conveyance of polyethylene water storage tank (ISI marked) with cover and suitable locking arrangement of capacity 500 Ltr - 1 No, Steel structural platform using ISA 75 x 75 x 6 - 108 Kg, inlet and outlet pipe connection using 20 mm CPVC pipe and specials - 66 M and valves, drain arrangement all labour charges, supplying 30/40 Ltr PVC bucket - 2 Nos and PVC mug - 2 Nos (for mixing bleaching powder), hire charges of tools etc complete as per the direction of engineer in charge.
OD161466/2024-2025:Supplying 3 x 6 sq.mm copper submersible flat cable having ISI mark
OD161543/2024-2025:Providing and conveying and fixing 90mm CPVC (10kg/cm2) of tube well vertical pipeline with nasasary specials, Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings and testing of joints complete as per the direction of Engineer-in-Charge. 90 mm nominal outer dia pipes
OD161475/2024-2025:Supplying good quality 80 mm GI BEND.
OD161476/2024-2025:Supplying Fabricated 80 mm GI TEE
OD161490/2024-2025:Supplying GSM type base model good quality mobile phone (Keypad type) for operating pump sets via remotely
Interconnecting distribution with pumping main
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.98.1008:Engaging Coolie.
100.98.236:Supply of PVC Pipe, 10kg/cm2, 90mm Dia.
100.9.8:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 90 mm nominal outside diameter pipes.
OD161000/2024-2025:Interconnecting the newly laid 90mm PVC pipe line to the existing 80mm GI pumping main using,90mm PVC adaptor, 90mm PVC pipe, 110mm X 90mm PVC reducer.and making water tight joint including cost and conveyance of all materials,. all labour charges, hire charges of tools etc complete as per the direction of engineer in charge.
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Power allocation charges to KSEB
OD161492/2024-2025:Power Allocation Charges to KSEB
Distribution line laying
100.59.1:Cutting the bituminous / concrete roads with cutting machine for a minimum depth of 200mm along the sides of proposed alignment of the pipe to be laid without causing any damage to other utilities, including the charges for hire and conveyance of tools and plant, cost of consumables and charges for lighting, watching, ribbon fencing, caution boards, traffic diversion, and as per the direction of departmental officers etc. complete, before carrying out the demolition of bituminous / concrete road by mechanical means and carrying out the excavation.
15.43.2:Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.98.1008:Engaging Coolie.
50.2.3.1:Pumping or Bailing out water and removing slush etc by using pump set including cost of labour, oil hire charges of pumpset, etc complete
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
100.98.213:Supply of PVC Pipe, 6kg/cm2, 90mm Dia.
100.9.8:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 90 mm nominal outside diameter pipes.
Alteration of water connection
OD162000/2024-2025:Altering the existing house connections to the newly laid pipe line
OD162020/2024-2025:Providing 20mm (1/2 inch) PVC Air Valve in the water meter assembly for 15mm connection, using 20mm Indian Standard Class 6 uPVC pipes and specials including cost of materials, consumables, hire for tools and labour charges etc. complete and as per the directions of the department officers.
P MANMADAN (BID ID -2454614)
Bidder Name
Ratheesh
P MANMADAN
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1382891.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
KWAGeneralConditionsforeTenderingV5.pdf
PDF • 0.69 MB
Tendernotice_1.pdf
PDF • 0.67 MB
NITREVISED.pdf
Tender Documents • 1.18 MB
BOQ_1382891.xls
BOQ • 0.34 MB
MotherNITorder.pdf
Additional Documents • 0.23 MB
PumpspecialConditions.pdf
Other Document • 0.10 MB
Supplyconditions.pdf
Other Document • 0.28 MB
Download all tender documents and submit your bid