| Sl No | Description | Qty | Unit | Master Electric Store L4 | AVADH KAARYA SOLUTIONS LLP L3 | R S ELECTRICAL L5 | NEW VICKY ENTERPRISES L1 | SONU TRADERS L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00Highmast Pole & LEDs ,Aviation Lights installation work | ||||||||
| 1.01 | Supply of 12.5 Mtr highmast tower in telescopic polygonal shape made of Hot Rolled Steel Sheets confirm to IS standard. 12.5 Mtr Height consist of two sections from top to bottom suitable for 47-50 m/sec wind speed . Both the Sections jointed via stress-fit method & overlapping of 1.5 times of intersection dia. The head frame assembly is specially design with latching technology in which the luminaire carriage engages a mechanical latch at the mast head upon hoisting, transferring tensile load from the wire ropes to the mast structure, thereby offloading the ropes in rest position. Luminaries carriage should be designed to install upto 6-8 nos luminaries in symmetrical arrangement. Highmast should have raising lowering system integral power tool motor, SS wire ropes, trailing cable, connectors, junction box. Hot dip galvanized lightening final of 1.2 Mtr Long must be mounted at top of head-frame (not on lanten carriage), Foundation bolts along with nuts, washers, anchor plate etc. and common template used for making civil foundation. Highmast & its Luminaire & Aviation Light should be of same make to avoid any Structural compatibility, Service & maintenance issues in future .Wind Tunnel Test Report/Type Test Report of Winch, SS Wire rope, Motor etc. must be submitted before approval .
Manufacturers should comply make in India & have ISO 45001:2018, ISO 14001:2015, ISO 4063 and ISO 3834 Certified and Manufacturing process of Highmast/Poles starting to end ,Galvanization process etc. should be under one premises .
The detailed specification required are as follows : | 1 | Each | 2,18,950 ₹2.2 L | 1,99,355.6 ₹2.0 L | 1,99,000 ₹2.0 L | 1,03,000 ₹1.0 L | 51,929.51 ₹51,929.51 |
| 1.02High Mast Specifications | ||||||||
| 1.03High Mast Specifications Height of mast- 12.5 mtr No. of section- Two section HR Material construction- HR sheet steel conform to IS 2062 / BS EN 10025 or Equivalent Base dia and top diameter- Base 360 mm, Top 150 mm (min) Sheet thickness- Bottom 3mm, Top 3mm Cross section of mast- 20 side polygonal Standard of Galvanisation- As per ASTM A 123/ ISO 1461 or equivalent Thickness of base plate- 25 mm minimum Diameter of Base plate- Minimum 520 mm Lightining protection final- G.I. single spike of length 1200 mm minimum Base wind speed as per IS 875- 180 km/hr or 50 mt/sec. Number of foundation bolts- 6 nos min manufactured from special EN8 Grade steel TS600 type PCD of foundation bolts- 445 mm minimum Type/Diameter/length of foundation bolts- TS 600/24 mm dia/ minimum 850 mm long Design safety factor- As per PLG 07 (ILE TR 07 renamed as PLG 07) Steel grade- BSEN-10025 with tensile strength 355 N/ sqm/ASTM A572 Welding Process- Single Longitudinal weld , No Circumferencial Weld allowed. Thickness of Galvanization- 86 Microns Minimum | ||||||||
| 1.04LANTERN CARRIAGE Material of construction- channel/50 mm dia ERW pipe Galvanized . No. of arms- 6 Arms,Welded,1 section or equivalent No. of Luminiare- 6 Nos. TRAILING CABLE Cable for supply- Copper Conductor,2.5/4.0 sqmm, 5 core maximum according to wattage of LED fittings Insulation /sheathed- EPR insulated & PCP sheathed No of cables/circuits as per mast- 1 No.(3 phase) flexible type multicore WINCH/POWER TOOL Type/SWL of winch-Double drum (DD2GPB) winch tested from IIT/any accredited Lab of Govt. Of India approved with specific load bearing capacity 500 kg min. Drum operation-Individual/combined Method of operation-Motorised/ Manual Motor capacity- 0.75/1 HP power tool 3 phase electric motor reversible type 415/ 250 volt integral (inside high mast) Torque limitor- With mechanical tripping facility No of speeds - Single speed 6 pole | ||||||||
| 1.05STAINLESS STEEL WIRE ROPE Grade/construction-ASIS 316,7/19, SS 316, 7/19 Construction tested from IIT/any accredited Lab of Govt. Of India approved and of reputed make Suspension system-3 Points suspension Number of ropes - 5 Nos. Diameter of Rope (mm)-6 mm dia (min) with 5 Nos. Ropes Breaking load capacity of rope- Minimum 2350 kg X 2 Factor of safety for wire ropes-Min. 5 for combined breaking load HEAD FRAME ASSEMBLY Head frame pully- Cast Aluminium(LM-6) No of Pully- 4 Nos. Head Frame type - Latching type | ||||||||
| 2.00 | Supply of 16M highmast tower in telescopic polygonal shape made of Hot Rolled Steel Sheets confirm to IS standard. 16 Mtr Height consist of two sections from top to bottom suitable for 47-50 m/sec wind speed . Both the Sections jointed via stress-fit method & overlapping of 1.5 times of intersection dia. The head frame assembly is specially design with latching technology in which the luminaire carriage engages a mechanical latch at the mast head upon hoisting, transferring tensile load from the wire ropes to the mast structure, thereby offloading the ropes in rest position. Luminaries carriage should be designed to install upto 8-10 nos luminaries in symmetrical arrangement. Highmast should have raising lowering system integral power tool motor, SS wire ropes, trailing cable, connectors, junction box. Hot dip galvanized lightening final of 1.2 Mtr Long must be mounted at top of head-frame (not on lanten carriage), Foundation bolts along with nuts, washers, anchor plate etc. and common template used for making civil foundation. Highmast & its Luminaire & Aviation Light should be of same make to avoid any Structural compatibility, Service & maintenance issues in future .Wind Tunnel Test Report/Type Test Report of Winch, SS Wire rope, Motor etc. must be submitted before approval .
Manufacturers should complied make in India & have ISO 45001:2018, ISO 14001:2015, ISO 4063 and ISO 3834 Certified and Manufacturing process of Highmast/Poles starting to end ,Galvanization process etc. should be under one premises .
The detailed specification required are as follows : | 3 | job | 2,86,900 ₹8.6 L | 2,40,864 ₹7.2 L | 2,80,000 ₹8.4 L | 1,85,000 ₹5.5 L | 67,000 ₹2.0 L |
| 2.01High Mast Specifications | ||||||||
| 2.02Height of mast- 16 mtr No. of section- Two section HR Material construction- HR sheet steel conform to IS 2062 / BS EN 10025 or Equivalent Base dia and top diameter- Base 410 mm, Top 150 mm (min) Sheet thickness- Bottom 4mm, Top 3mm Cross section of mast- 20 side polygonal Standard of Galvanisation- As per ASTM A 123/ ISO 1461 or equivalent Thickness of base plate- 25 mm minimum Diameter of Base plate- Minimum 570 mm Lightining protection final- G.I. single spike of length 1200 mm minimum Base wind speed as per IS 875- 180 km/hr or 50 mt/sec. Number of foundation bolts- 8 nos min manufactured from special EN8 Grade steel TS600 type PCD of foundation bolts- 490 mm minimum Type/Diameter/length of foundation bolts- TS 600/30 mm dia/ minimum 850 mm long Design safety factor- As per PLG 07 (ILE TR 07 renamed as PLG 07) Steel grade- BSEN-10025 with tensile strength 355 N/ sqm/ASTM A572 Welding Process- Single Longitudinal weld , No Circumferencial Weld allowed. Thickness of Galvanization- 86 Microns Minimum | ||||||||
| 2.03LANTERN CARRIAGE Material of construction- channel/50 mm dia ERW pipe Galvanized . No. of arms- 8 Arms,Welded,1 section or equivalent No. of Luminiare- 8 Nos. TRAILING CABLE Cable for supply- Copper Conductor,2.5/4.0 sqmm, 5 core maximum according to wattage of LED fittings Insulation /sheathed- EPR insulated & PCP sheathed No of cables/circuits as per mast- 1 No.(3 phase) flexible type multicore WINCH/POWER TOOL Type/SWL of winch-Double drum (DD2GPB) winch tested from IIT/any accredited Lab of Govt. Of India approved with specific load bearing capacity 750 kg min. Drum operation-Individual/combined Method of operation-Motorised/ Manual Motor capacity- 1 HP power tool 3 phase electric motor reversible type 415/ 250 volt integral (inside high mast) Torque limitor- With mechanical tripping facility No of speeds - Single speed 6 pole | ||||||||
Updated dates
Tender Value
₹44.9 L
EMD Value
₹89,787
Closing Date
5 Feb 2026, 3:00 pmClosed
AGM EM
FCI Regional Office Lucknow
SITC of Latching Type High Mast Light along with allied electrical works at FSD Dhamora under DO Moradabad.
2026_FCI_895408_1
UP/EM/37/MCW/2025-26
Open Tender
Electrical Works
90 days
FCI FSD Dhamora
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹89,787
FCI Regional Office Lucknow
5 Mar 2026
23 Jan 2026
6 Feb 2026
23 Jan 2026
5 Feb 2026
23 Jan 2026
28 Jan 2026
Highmast Pole & LEDs ,Aviation Lights installation work
Supply of 12.5 Mtr highmast tower in telescopic polygonal shape made of Hot Rolled Steel Sheets confirm to IS standard. 12.5 Mtr Height consist of two sections from top to bottom suitable for 47-50 m/sec wind speed . Both the Sections jointed via stress-fit method & overlapping of 1.5 times of intersection dia. The head frame assembly is specially design with latching technology in which the luminaire carriage engages a mechanical latch at the mast head upon hoisting, transferring tensile load from the wire ropes to the mast structure, thereby offloading the ropes in rest position. Luminaries carriage should be designed to install upto 6-8 nos luminaries in symmetrical arrangement. Highmast should have raising lowering system integral power tool motor, SS wire ropes, trailing cable, connectors, junction box. Hot dip galvanized lightening final of 1.2 Mtr Long must be mounted at top of head-frame (not on lanten carriage), Foundation bolts along with nuts, washers, anchor plate etc. and common template used for making civil foundation. Highmast & its Luminaire & Aviation Light should be of same make to avoid any Structural compatibility, Service & maintenance issues in future .Wind Tunnel Test Report/Type Test Report of Winch, SS Wire rope, Motor etc. must be submitted before approval . Manufacturers should comply make in India & have ISO 45001:2018, ISO 14001:2015, ISO 4063 and ISO 3834 Certified and Manufacturing process of Highmast/Poles starting to end ,Galvanization process etc. should be under one premises . The detailed specification required are as follows :
High Mast Specifications
High Mast Specifications Height of mast- 12.5 mtr No. of section- Two section HR Material construction- HR sheet steel conform to IS 2062 / BS EN 10025 or Equivalent Base dia and top diameter- Base 360 mm, Top 150 mm (min) Sheet thickness- Bottom 3mm, Top 3mm Cross section of mast- 20 side polygonal Standard of Galvanisation- As per ASTM A 123/ ISO 1461 or equivalent Thickness of base plate- 25 mm minimum Diameter of Base plate- Minimum 520 mm Lightining protection final- G.I. single spike of length 1200 mm minimum Base wind speed as per IS 875- 180 km/hr or 50 mt/sec. Number of foundation bolts- 6 nos min manufactured from special EN8 Grade steel TS600 type PCD of foundation bolts- 445 mm minimum Type/Diameter/length of foundation bolts- TS 600/24 mm dia/ minimum 850 mm long Design safety factor- As per PLG 07 (ILE TR 07 renamed as PLG 07) Steel grade- BSEN-10025 with tensile strength 355 N/ sqm/ASTM A572 Welding Process- Single Longitudinal weld , No Circumferencial Weld allowed. Thickness of Galvanization- 86 Microns Minimum
LANTERN CARRIAGE Material of construction- channel/50 mm dia ERW pipe Galvanized . No. of arms- 6 Arms,Welded,1 section or equivalent No. of Luminiare- 6 Nos. TRAILING CABLE Cable for supply- Copper Conductor,2.5/4.0 sqmm, 5 core maximum according to wattage of LED fittings Insulation /sheathed- EPR insulated & PCP sheathed No of cables/circuits as per mast- 1 No.(3 phase) flexible type multicore WINCH/POWER TOOL Type/SWL of winch-Double drum (DD2GPB) winch tested from IIT/any accredited Lab of Govt. Of India approved with specific load bearing capacity 500 kg min. Drum operation-Individual/combined Method of operation-Motorised/ Manual Motor capacity- 0.75/1 HP power tool 3 phase electric motor reversible type 415/ 250 volt integral (inside high mast) Torque limitor- With mechanical tripping facility No of speeds - Single speed 6 pole
STAINLESS STEEL WIRE ROPE Grade/construction-ASIS 316,7/19, SS 316, 7/19 Construction tested from IIT/any accredited Lab of Govt. Of India approved and of reputed make Suspension system-3 Points suspension Number of ropes - 5 Nos. Diameter of Rope (mm)-6 mm dia (min) with 5 Nos. Ropes Breaking load capacity of rope- Minimum 2350 kg X 2 Factor of safety for wire ropes-Min. 5 for combined breaking load HEAD FRAME ASSEMBLY Head frame pully- Cast Aluminium(LM-6) No of Pully- 4 Nos. Head Frame type - Latching type
Supply of 16M highmast tower in telescopic polygonal shape made of Hot Rolled Steel Sheets confirm to IS standard. 16 Mtr Height consist of two sections from top to bottom suitable for 47-50 m/sec wind speed . Both the Sections jointed via stress-fit method & overlapping of 1.5 times of intersection dia. The head frame assembly is specially design with latching technology in which the luminaire carriage engages a mechanical latch at the mast head upon hoisting, transferring tensile load from the wire ropes to the mast structure, thereby offloading the ropes in rest position. Luminaries carriage should be designed to install upto 8-10 nos luminaries in symmetrical arrangement. Highmast should have raising lowering system integral power tool motor, SS wire ropes, trailing cable, connectors, junction box. Hot dip galvanized lightening final of 1.2 Mtr Long must be mounted at top of head-frame (not on lanten carriage), Foundation bolts along with nuts, washers, anchor plate etc. and common template used for making civil foundation. Highmast & its Luminaire & Aviation Light should be of same make to avoid any Structural compatibility, Service & maintenance issues in future .Wind Tunnel Test Report/Type Test Report of Winch, SS Wire rope, Motor etc. must be submitted before approval . Manufacturers should complied make in India & have ISO 45001:2018, ISO 14001:2015, ISO 4063 and ISO 3834 Certified and Manufacturing process of Highmast/Poles starting to end ,Galvanization process etc. should be under one premises . The detailed specification required are as follows :
High Mast Specifications
Height of mast- 16 mtr No. of section- Two section HR Material construction- HR sheet steel conform to IS 2062 / BS EN 10025 or Equivalent Base dia and top diameter- Base 410 mm, Top 150 mm (min) Sheet thickness- Bottom 4mm, Top 3mm Cross section of mast- 20 side polygonal Standard of Galvanisation- As per ASTM A 123/ ISO 1461 or equivalent Thickness of base plate- 25 mm minimum Diameter of Base plate- Minimum 570 mm Lightining protection final- G.I. single spike of length 1200 mm minimum Base wind speed as per IS 875- 180 km/hr or 50 mt/sec. Number of foundation bolts- 8 nos min manufactured from special EN8 Grade steel TS600 type PCD of foundation bolts- 490 mm minimum Type/Diameter/length of foundation bolts- TS 600/30 mm dia/ minimum 850 mm long Design safety factor- As per PLG 07 (ILE TR 07 renamed as PLG 07) Steel grade- BSEN-10025 with tensile strength 355 N/ sqm/ASTM A572 Welding Process- Single Longitudinal weld , No Circumferencial Weld allowed. Thickness of Galvanization- 86 Microns Minimum
LANTERN CARRIAGE Material of construction- channel/50 mm dia ERW pipe Galvanized . No. of arms- 8 Arms,Welded,1 section or equivalent No. of Luminiare- 8 Nos. TRAILING CABLE Cable for supply- Copper Conductor,2.5/4.0 sqmm, 5 core maximum according to wattage of LED fittings Insulation /sheathed- EPR insulated & PCP sheathed No of cables/circuits as per mast- 1 No.(3 phase) flexible type multicore WINCH/POWER TOOL Type/SWL of winch-Double drum (DD2GPB) winch tested from IIT/any accredited Lab of Govt. Of India approved with specific load bearing capacity 750 kg min. Drum operation-Individual/combined Method of operation-Motorised/ Manual Motor capacity- 1 HP power tool 3 phase electric motor reversible type 415/ 250 volt integral (inside high mast) Torque limitor- With mechanical tripping facility No of speeds - Single speed 6 pole
STAINLESS STEEL WIRE ROPE Grade/construction-ASIS 316,7/19, SS 316, 7/19 Construction tested from IIT/any accredited Lab of Govt. Of India approved and of reputed make Suspension system-3 Points suspension Number of ropes - 5 Nos. Diameter of Rope (mm)-6 mm dia (min) with 5 Nos. Ropes Breaking load capacity of rope- Minimum 2350 kg X 2 Factor of safety for wire ropes-Min. 5 for combined breaking load HEAD FRAME ASSEMBLY Head frame pully- Cast Aluminium(LM-6) No of Pully- 4 Nos. Head Frame type - Latching type
Supply of 200 watt LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt). Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 200 watt
Supply of 150 Watt LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt). Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 150 watt
SITC of LED Type Single dome aviation obstruction light of Medium Intensity having 2000 candela output, IP65 Protection NABL approved with mounting bracket.
Installation,Testing & Commissioning of the high mast with the help of suitable tools and plants, including Hydra etc. wiring connections of luminaires with all wiring materials like PVC insulated PVC sheathed flexible cable of size 3x2.5 Sqmm, lugs, MCB and all labour.
Construction of RCC foundation for 12.5 meter High Mast Pole including earthwork in excavation in all kinds of soil , filling of excavated earth in trenches/plinth, providing and laying PCC 1:4:8 with 40 mm aggregate, centering and shuttering for foundation surfaces, supplying and fixing Fe-500D reinforcement steel, and providing and laying RCC M-20 grade with 20 mm aggregate, complete as per drawing and the additional specifications attached in Annexure of MTF and direction of Engineer-in-Charge.
Construction of RCC foundation for 16 meter High Mast Pole including earthwork in excavation in all kinds of soil, filling of excavated earth in trenches/plinth, providing and laying PCC 1:4:8 with 40 mm aggregate, centering and shuttering for foundation surfaces, supplying and fixing Fe-500D reinforcement steel, and providing and laying RCC M-20 grade with 20 mm aggregate, complete as per drawing and the additional specifications attached in Annexure of MTF and direction of Engineer-in-Charge
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Supply, installation, testing and commissioning of outdoor-type Control Panel (IP-65) of size 750x400x250 mm, 415V, 32A TPN, stand-mounted, dust- & vermin-proof, fabricated from 14 SWG CRCA sheet steel with epoxy-polyester powder coating, complete with 32A TPN MCB incomer, 25A TP contactor for automatic switching of Luminares , 22A/9A Contactor,6A control MCB, time switch with bypass arrangement, HRC fuse or equi., ON/OFF push buttons, Toggle Switch-Auto-Off-Manual, R/Y/B/GE indication lamps, terminal blocks, detachable bottom gland plate, internal FRLS wiring with ferrules & lugs, laminated wiring diagram, name plate, danger board, and 35x35x3 mm MS angle stand — fully wired, tested and suitable for high-mast lighting operation.
Supply of PVC insulated PVC sheathed cable of 1.1KV grade armoured Underground aluminum conductor cable as reqd confirming to IS –7098 part I with up to date amendments) of the following size
3.5x 70 sqmm.
3.5x 35 sqmm.
4x 16 sqmm.
4x 6 sqmm.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/HDPE pipe as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Supplying and laying of following size HDPE pipe(PN 6, PE 63) ISI marked along with all accessories like socket, bend, couplers etc. as per latest standard IS Code, Part II complete with fitting and cutting, jointing etc. Direct in ground (75cm below ground level)including excavation and refeling the trench but excludingsand cushioning and protective covering etc.complete as requied. 40 mm dia (OD=40 mm & ID=35 mm nominal)
Supplying and laying of following size HDPE pipe(PN 6, PE 63) ISI marked along with all accessories like socket, bend, couplers etc. as per latest standard IS Code, Part II complete with fitting and cutting, jointing etc. on wall surface as required. (clamped with 1mm thick saddle) 63 mm dia
Supplying and laying of following size HDPE pipe(PN 6, PE 63) ISI marked along with all accessories like socket, bend, couplers etc. as per latest standard IS Code, Part II complete with fitting and cutting, jointing etc. Direct in ground (125 cm below ground level)including excavation and refeling the trench but excludingsand cushioning and protective covering etc.complete as requied. 63 mm dia
Supply and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (conforming to IS 12943 (1990) or equivalent with upto date amendments)
3.5x70 sqmm(38mm)
3.5x35 sqmm(32mm)
4x16 sqmm(28mm)
Supplying and fixing 30A, 415 Volts, TPN industrial type,socket outlet,with 4 pole and earth,metal enclosed plug top alonwith 30A "C" curve,TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outletand complete with connections,testing and commissioning etc. as required
Supplying , installation , testing and commissioning of cubical type,inverted V shaped top, outdoor feeder pillar panel with size (1.0x1.0x.4 Mtr) suitable for operation at 415 (+/-) 6% Volts,50Hz,3 Phase 4 Wire system made out from CRCA sheet steel 2.0 mm and covers shall be cold rolled sheet thickness not less than 1.6mm fabricated factory finished followed-42 by powder coated painting & provided with gaskit etc. to make dust & vermin proof degree of IP ,Weather Proof, hinged type openable door , loaking arrangement , detachable gland plate , connection , interconnections with suitable size (150 Amp capacity) 4 strip high conductivety elctrical aluminium (ALU) busbar codifies in red,yellow,blue and black colour and PVC insulated copper conductor cable 1100Volt grade for internal wiring including providing and fixing digital type Ampere meter, Voltmeter, Indication LED lamp, ,Labeling comprise white letters on black background including foundation works etc as required with following:- (Confoming to relevent BIS/IS standard or equivalent) 1)4P MCCB 150Amps,36KA-01No 2) 4P MCCB 100 Amps.25KA-03 Nos 3) MCB DP 40 Amps -02 Nos 4) TPN MCB 63Amp-02 Nos 5) 4 strip AL Busbar 250Amp- 01 Set
Supply, Installation,Testing & commissioning of LED pylon signage(both side LED lightening) of Specified sizes fabricated out of 1"x1" MS pipe box, 3mm thick computerised router cut ACP Sheet and 3mm thick acrylic sheet pasted from back of the cut out letters, logo and complete content with LED and waterproof & dustproof power supplies for backlit purpose. Powder coated Aluminum sheet shall be fixed from the required side of the entire board to make box section, Light Source: LED modules , Lumens: 120–150 lumens per watt for standard module, Life: min. 60,000 burning hours, Power consumption - ~ 1.5 Watt per module(approx), input:230V, output: 12V DC, 1ft = ~ 3 Module, Working Temperature: -10 ℃ to 55 ℃, making it visible even in low light conditions, Waterproof LED modules, energy-efficient IP68 rated with colour temperature with IP68 grade power supply, Backlight with transparent acrylic backs etc. Frame will be held on min. 2 nos. MS angle of required length of min. size 1"X1" from the ground including required suitable foundation( including required earthwork exacavation , laying PCC(1:3:6), Cement concrete(1:1.5:3) , shuttering, plastering of 6mm including filling of exacavated sand) to support pylon board with " Food Corporation of India, FSD Dhamora, FCI Logo, address etc. written in Hindi and English language on both sides of board .Design as per the latest FCI norms to be provided by FCI and as per the direction of Engineer-in-charge .
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
techsummary_941216.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.88 MB
MTF_Dhamora.pdf
Tender Documents • 2.84 MB
BOQ_941216.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid