| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.5 LAccepted-AOC D NO 38 39 86 3 4 SAIKRUPA RESIDENCY 104 AREA BAPUJI NAGAR MARRIPALEM VISAKHAPATNAM 530 007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹26.8 L+₹22,845 (0.86%)Rejected-Finance | L2 | Rejected-Finance Being Not L1 | |
| 3 | L3₹29.1 L+₹2.6 L (9.76%)Rejected-Finance D NO 29 2 43 SING HOTEL JUNCTION CMR ROAD VISAKHAPATNAM 530 020 | VISAKHAPATANAM | ANDHRA PRADESH | 530020 | L3 | Rejected-Finance Being Not L1 | |
| 4 | L4₹30.1 L+₹3.6 L (13.5%)Rejected-Finance | L4 | Rejected-Finance Being Not L1 | |
| 5 | L5₹38.0 L+₹11.5 L (43.4%)Rejected-Finance DOOR NO 2 31 23 SECTOR 7 SBI COLONY MVP VISAKHAPATNAM 530 017 | VISAKHAPATANAM | ANDHRA PRADESH | 530017 | L5 | Rejected-Finance Being Not L1 |
Tender Value
₹43.2 L
EMD Value
₹86,400
Closing Date
3 Dec 2022, 6:00 pmClosed
GARRISON ENGINEER I DOCKYARD MAINT NAVAL DOCKYARD
GARRISON ENGINEER I DOCKYARD MAINT NAVAL DOCKYARD VISAKHAPATNAM
ATTENDING DAY TO DAY COMPLAINTS/ BREAKDOWNS AND CALL ON REPAIRS FOR 24 HRS OF COPE POINTS, PBS, LT CABLE JOINTS, MARINE SUBSTATION LT PANELS AND ALLIED WORKS IN DOCKYARD JETTY AREA AT NAVAL DOCKYARD VISAKHAPATNAM UNDER GE (I) (DM) VISAKHAPATNAM
2022_MES_561751_1
SSGE/8750/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GARRISON ENGINEER I DOCKYARD MAINT NAVAL DOCKYARD
As per tender documents
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER I DOCKYARD MAINT NAVAL DOCKYARD
₹86,400
Yes
27 Dec 2022
5 Nov 2022
10 Dec 2022
5 Nov 2022
3 Dec 2022
19 Nov 2022
Amount
Attending day to day work and breakdown and call on repair for uninterupted shore power supply cope points, Junction boxes, Pillar boxes, LT cables off sizes, earthings, cable joints etc complete by providing daily minimum 03 electrician and 03 helper during the complete work period complete all as specified and as directed. Note: (a) Contractor shall not claim for outsourcing (b) Work will be measured as per unit specified
M&L for finding of cable fault inside Jetty gallery by disconnecting both cable ends, using insulation tester, cable fault finder and rectification complete by cutting at fault position, fixing of straight through heat shrink joint, for cable sizes 150 sqmm to 500 sqmm, 3.5 core, 1100 volts grade and reconnection of both cable end to original position, replacement of defective aluminium cable lugs, fixing with old or required new nuts-bolts-washers complete with testing complete all as specified and as directed. Note: (a) Items required for rectification such as Heat shrink cable end terminals / straight through joints / heat shrink sleeves shall be measured separately as supply only. (b) Required aluminium cable lugs and nuts-bolts-washers shall be inclusive of quoted rate.
M&L for de-carbonizing/cleaning of LT 415/380 V 3 phase Air Circuit Breaker at Pillar boxes inside/above Jetty Gallery by removing outer door, inner door, by draw-out movable unit from base, keeping aside carefully, removing all cable connection from rear side bus, interconnection bus between main bus and ACB, checking for any defects due to any flush/loose contact, cleaning of all fixed and moving contact point, terminal connection points with CTC and re-fixing moving unit of ACB, cables, bus the same after applying Backtol (red) solution to the bus bar insulator and replacement of defective aluminium cable lugs and tightening the nuts, bolts, spring washers & thimbles complete all as specified and as directed. Note: (a) required male/female ACB contacts, trip coils, closing coils, electronic protection unit will be inclusive of quoted rate. (b) required aluminium cable lugs and nuts-bolts-washers shall be inclusive of quoted rate (c) all cleaning agents are included in the quoted rate. (d) Disconnection and reconnection of cable will be measured separately
M&L for de-carbonizing/cleaning of LT 415/380 V 3 phase, 4 wire Junction boxes inside Jetty Gallery used for distribution of power to different pillar boxes by removing cover, by dismantling bunch of cable termination of 3ph+N busbar (cable terminations are not less than 16 nos in each phase of 150 sqmm to 500 sqmm) taking out aluminium/copper complete busbar off sizes, checking for any defects due to any flush, loose contact and cleaning of complete bus with CTC, cleaning of all bus insulators and re-fixing bus etc after applying Backtol (red) solution to the insulator and and refixing all cable connections, replacement of damaged cable lugs and replacement of damaged nuts, bolts, washers and tightening of all nuts, bolts including one coat of painting to inside chamber of cope point with synthetic enamel paint complete all as specified and as directed. Note: (a) required aluminium or copper busbars, coloured heat shrink sleeve for busbar, cable kits, will be measured as supply only, (b) required busbar insulators, aluminium cable lugs and nuts-bolts-washers shall be inclusive of quoted rate.
M&L for de-carbonizing/cleaning of complete LT 415/380 V 3 phase Pillar boxes inside/above Jetty Gallery by removing cover, by dismantling bunch of cable termination of 3ph+N busbar from inside gallery (cable terminations are not less than 4 nos in each phase of 150 sqmm to 500 sqmm) taking out aluminium/copper complete busbar off sizes, checking for any defects due to any flush, loose contact and cleaning of complete bus with CTC, replacing damaged coloured heat shrink sleeve, cleaning of all bus insulators and re-fixing bus etc after applying Backtol (red) solution to the insulator and refixing all cable connections, replacement of damaged cable lugs and tightening the nuts, bolts, washers including one coat of painting to inside chamber of cope point with synthetic enamel paint complete all as specified and as directed. Note: (a) required aluminium or copper busbars, coloured heat shrink sleeve for busbar, cable kits, will be measured as supply only, (b) required busbar insulators, aluminium cable lugs and nuts-bolts-washers shall be inclusive of quoted rate.
M&L for de-carbonizing/cleaning of complete LT 415/380 V 3 phase Cope points fixed at edge of Jetty with half portion above GL and half portion in gallery by removing cover, by dismantling bunch of cable termination of 3ph+N busbar from inside gallery (cable terminations are not less than 4 nos in each phase of 150 sqmm to 500 sqmm) taking out aluminium/copper complete busbar off sizes, checking for any defects due to any flush, loose contact and cleaning of complete bus with CTC, replacing damaged coloured heat shrink sleeve, cleaning of all bus insulators and re-fixing bus etc after applying Backtol (red) solution to the insulator and refixing all cable connections, replacement of damaged cable lugs and tightening the nuts, bolts, washers including one coat of painting to inside chamber of cope point with synthetic enamel paint complete all as specified and as directed. Note: (a) required aluminium or copper busbars, coloured heat shrink sleeve for busbar, cable kits, will be measured as supply only, (b) required busbar insulators, aluminium cable lugs and nuts-bolts-washers shall be inclusive of quoted rate.
M&L for de-carbonizing/cleaning of complete LT 415/380 V 3 phase Welding Cope points fixed at edge of Jetty above GL by removing cover, by dismantling cable termination of 3ph+N busbar from inside gallery taking out aluminium/copper complete busbar off sizes, checking for any defects due to any flush, loose contact and cleaning of complete bus with CTC, replacing damaged coloured heat shrink sleeve, cleaning of all bus insulators and re-fixing bus etc after applying Backtol (red) solution to the insulator and refixing all cable connections, replacement of damaged cable lugs and tightening the nuts, bolts, washers including one coat of painting to inside chamber of cope point with synthetic enamel paint complete all as specified and as directed. Note: (a) required aluminium or copper busbars, cable kit, coloured heat shrink sleeve for busbar will be measured as supply only. (b) required busbar insulators, aluminium cable lugs and nuts-bolts-washers shall be inclusive of quoted rate.
Dismantling taking out complete burnt cable end termination of sizes 150 sqmm to 500 sqmm, 3.5 core from ACB/MCCB terminals/busbars, cutting cable ends for replacement of burnt/defective aluminiumcable lugs and fixing to ACB/MCCB terminals/busbars with nuts, bolts, washers, aluminium cable lugs complete all as specified and as directed. Note- (a) required aluminium cable lugs and nuts-bolts-washers and busbar insulator shall be inclusive of quoted rate
Supply only Heat shrink cable end terminal for 3.5 core 1100 V, 150 to 185 sqmm complete all as specified and as directed. Make 3M/Denson/M Seal/MS Seal/RPG.
Supply only Heat shrink cable end terminal for 3.5 core 1100 V, 240 to 300 sqmm complete all as specified and as directed. Make 3M/Denson/M Seal/MS Seal/RPG.
Supply only Heat shrink cable end terminal for 3.5 core 1100 V, 400 to 500 sqmm complete all as specified and as directed. Make 3M/Denson/M Seal/MS Seal/RPG.
Supply only Heat Shrink sleeve outer protection insulating tube (Coated) single core, for application range 9-29mm complete all as specified and as directed. Make- RPG/3M/Danson/M Seal
Supply only coloured Heat Shrink sleeve busbar insulation tube single core, for application range upto 150 mm complete all as specified and as directed. Make- RPG/3M/Danson/M Seal
Supply only Busbar anodised aluminium off sizes including required drilling holes for fixing with other bus / cable connections complete all as specified and as directed.
Supply only Busbar anodised copper off sizes including drilling holes for fixing with other bus / cable connections complete all as specified and as directed.
S&F digital Voltmeter 0-500v including connections and rectification of internal wiring defects after dismantling and taking out unserviceable one complete all as specified and as directed.
S&F digital Ammeter 0-2000 A including connections and rectification of internal wiring defects after dismantling taking out unserviceable one complete all as specified and as directed.
S&F LED indicator lamp R-Y-B after dismantling taking out unserviceable one complete all as specified and as directed.
S&F CT (current transformer), 1100 volts grade, CT ratio 800/5 to 2000/5 as per existing shape and size including connections and rectification of internal wiring defects after dismentling taking out unserviceable one complete all as specified and as directed.
M&L for taking out damaged door of Pillar Boxes / cope points due to broken hinges or other reason and making necessary arrangement for fixing new MS fabricated hinges to body of PB/CP and refixing existing door or new door after proper fabrication to existing shape and fixing to hinges, door locks complete all as specified and as directed. Note-New MS sheet as required for door will be measured as supply only
Fabrication and supply doors of PB or JB or cope points made with MS sheet 3mm thick including painting with one coat of red oxide and two coat of synthetic enamel paint complete all as specified and as directed.
S&F Galvanised iron earthing strip 32x6mm including connection with existing strip by making necessary drilled hole incl dismantling taking out unserviceable earthing strip of any size to PB/CP/JB/main earth bus complete all as specified and as directed.
M&L for painting of outside surface of Pillar boxes located outside or inside Jetty with one coat of synthetic enamel paint on every alternate 03 month complete all as specified and as directed.
M&L for painting of outside surface of Cope Points located outside or inside Jetty with one coat of synthetic enamel paint on every alternate 03 month complete all as specified and as directed.
M&L for painting of outside surface of Junction boxes located inside Jetty with one coat of synthetic enamel paint on every alternate 03 month complete all as specified and as directed.
M&L for writing letter on front surface Pillar boxes/Cope Points/Junction boxes located outside or inside Jetty with white colour synthetic enamel paint on black back ground showing Voltage, PB-No, feeder No, Tr-No, SS No/name with letter size 50 mm x40 mm after every alternate 06 month complete all as specified and as directed.
M&L for white washing of PCC foundation of PB/CP/security light pole on every alternate month complete all as specified and as directed.
Supply and fix LT ACB 3 pole 1600 A, 50 KA breaking capacity, 415 V, 50 Hz, manual drawn out type and manually charged with micro processor ET6G trip release protection system against over current, earth fault and short circuit with 2 NO + 2 NC auxiliary switch, main CTs, safety shutter, cradle guard, operating handles complete all as specified and as directed. Make:- Schneider /L&T/ABB.
All as per item No 27 above but of capacity 1250Amps, 3pole complete all as specified and as directed. Make:- Schneider/ ABB/L&T
All as per item No 27 above but of capacity 1000Amps, 3pole complete all as specified and as directed. Make:- Schneider/ ABB/L&T
Supply and fix MCCB, 3 pole, 630 amp, 36 KA breaking capacity, Ics = 100% Icu, with Thermal magnetic release, complete all as specified and as directed. Make- Schneider /Legrand/ABB
Supply and fix MCCB, 3 pole, 400amp, 36 KA breaking capacity, Ics = 100% Icu, with Thermal magnetic release, complete all as specified and as directed. Make- Schneider /Legrand/ABB
Supply and fix MCCB, 3 pole, 250amp, 36 KA breaking capacity, Ics = 100% Icu, with Thermal magnetic release, complete all as specified and as directed. Make- Schneider /Legrand/ABB
Supply and fix MCCB, 3 pole, 100amp, 16 KA breaking capacity, Ics = 100% Icu, with Thermal magnetic release, complete all as specified and as directed. Make- Schneider /Legrand/ABB
M&L for replacement of worn out MS fabricated stand/support of cable/PB/JB inside or outside gallery with suitable size of MS sections by welding, cutting, jointing, and with one coat of red oxide primer and 2 coats of black bituminous paint complete all as specified and as directed.
M&L for taking out damaged Pillar Boxes / cope points from inside of gallery due to rusted surface or other reason and making necessary arrangement for repairing it by removing cables from Busbars/ ACBs/ MCCBs for fixing new MS fabricated body of PB/CP and refixing existing door after repair or new door after proper fabrication to existing shape and fixing to hinges, door locks and painting of inside surface with one coat of epoxy paint and refixing of PB inside gallery to the original location complete all as specified and directed by Engr-in-charge. Note:-New MS sheet as required will be measured as seperately.
B.Veerabhadra Rao
KIRON ENGINEERING CORPORATION
R AND A ASSOCIATES ENGINEERS CONTRACTORS
M/s SS Engineering Enterprises
M/s Sai Venkata Durga Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .