Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.0 LAccepted-AOC 20 8 EWS PREETAM NAGAR COLONY ALLAHABAD | PRAYAGRAJ | UTTAR PRADESH | 211001 | L1 | Accepted-AOC LOWEST REASONABLE BID | |
| 2 | L2₹43.6 L+₹5.7 L (14.9%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹46.8 L+₹8.8 L (23.2%)Rejected-Finance OPP INCOME TAX OFFICE PAOTA C ROAD JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | Rejected-Technical | - | Rejected-Technical Not Eligible bidder as Details for Balance work has not submitted / uploaded | |
| 5 | Rejected-Technical | - | Rejected-Technical Not Eligible bidder as No remarks in WLR of QE Jun 2023 of HQ CESWC |
Tender Value
₹43.5 L
EMD Value
₹87,000
Closing Date
4 Dec 2023, 6:00 pmClosed
CWE ARMY JODHPUR
CWE ARMY MULTAN LINE ARMY AREA JODHPUR-342010
PROVN OF REPAIR SHED FOR C VEH WITH HARD STANDING WITH 2 TON TRAVELLING TROLLEY AT FD WKSP COY IN ARMY AREA JODHPUR UNDER GE (ARMY) NO. 01
2023_MES_627158_1
82324/85/E8
Open Tender
Civil Works
Item Rate
180 days
JODHPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (ARMY) NO. 01
₹87,000
Yes
18 Jan 2024
7 Nov 2023
9 Dec 2023
7 Nov 2023
4 Dec 2023
20 Nov 2023
8 Nov 2023 - 18 Nov 2023
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out any type of soil/rock complete all as specified and directed.
M&L PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in flooring,path , sub foundation etc complete all as specified and directed.
Excavating in post holes each n exc 0.5 cum , getting out in soft loose soil ,returning filling in and ramming earth or broken rubble mixed with earth around, in layers nt exc 25cm ,watering and removing surplus soil to a distance n exc 50m and making good surface complete all as specified and directed.
M & L for cement concrete in foundations ,filling and mass concrete type C2 1:3:6(40 mm gradede aggregrate) as inpost hole and complete all as specified and directed.
M&L for Reinforced cement concrete (design mix-25) in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter all complete all as specified and directed.
M&L for TMT Mild steel bars 10mm dia and over, cut tolength, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for TMT Mild steel bars , but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.
Surface excavation n.exc(not exceeding) 30 cm deep and averaging 15cm deep and getting out any type of soil complete all as specified and directed.
Hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as specified and directed.
S & F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1998 grade St- 240 complete all as specified and directed.
S & F roof trusses(framed), trussed,purlins,crane gantries,rails(I-section with ISMB 250) and fastenings and heavy bracket framing including distance ieces, cleats etc. complete all as specified and directed.
S&F plates (plain or /mdsplate chequered) channels square cut or notched (ordinary and counter sunk) forming holes with riveted bolted or welding attachement complete all as specified and directed.
M & L for preparing new steel surfaces of any description exc 10 cm in width, priming with red oxide and applied two coat of synthetic enamel paint complete all as specified and directed.
S&F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering to wall fixed with self tapping screws complete all as specified and directed.
M&L 100mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregate as in sub base complete all as specified and directed.
M&L for Cement concrete work in pavement/ hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less complete all as specified and directed.
M&L for squarred rubble walling Jodhpur type regular coursed well bonded ,bedded and solidly hearted built in cement mortar 1:6 complete all as specified and directed.
Extra over squared rubble stone walling Jodhpur type regular course for hammer dressing to face of stone with max depression on face from a straight edge not exc 20mm and dressing complete to squared rubble walling, regular coursed, Jodhpur type complete all as specified and directed.
M&L for Keyed pointing to square rubble masonry Jodhpur type regular course in CM 1:3 complete all as specified and directed.
M&L two coats of cement based paint on newly plastered/ unplastered surface of wall including preparation and one coat of chalk white of serfaces complete all as specified and directed.
M&L for PCC 1:2:4 type B1 Mix using 20mm graded stone aggregate as in hold fast iron fixing,coping, chamfered edges including necessary form work complete all as specified and directed.
M&L PCC solid building blocks 10 cm thick type B1 1:2:4 set in cement mortar (1:6) complete all as specified and directed.
M&L for 15mm thick rendering in CM 1:6 finished even and smooth without extra cement on stone wall surface complete all as specified & directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete all as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
S&F Expanded metal,N exc 4 kg cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members complete all as specified and directed.
Steel rolling shutters, 1.00 thick with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete with gear operated type with bevel gear box and crank handle complete all as specified and directed.
S&F Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc complete all as specified and directed.
S&F Mild Steel Screw bolts Diameter of neck in mm 16-20mm (machine made) with hexagonal or square heads at one end and screwed both ends,each screwed ends to be fitted with washers and one hexagonal or square nut, but length of bolt exc 22.5 cm bt n exc 30cm long, complete all as specified and directed.
Supply and lay in trenches/on wall/on pole/in duct /through protection pipe, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables heavy duty LT cable, 1100 volts grade with aluminium conductor cross sectional area 16 Sqmm 4 core size including retrieving/taking out/taking down old unserviceable cable from duct/trenches/pipes/pole/wall etc. including brick cover and protection pipe and disconnecting the connections. Note:- Excavation and earth work, sand cushioning,PCC cable cover and protection pipe etc. shall be measured and paid for separately.
M&L for dry clean fine river sand as in sand cushioning to underground cable including punning down of sand layer all as specified and directed. Note :- Punned thickness shall only be measured and paid.
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1, flat, size 250x150mm x40 mm
M&L for galvanised steel tubing, light grade, for protection of cable, laid in trenches/road crossing/floor or fixed to pole/wall with all fittings, of size 40 mm bore.
M & L for surface point wiring complete with multistranded copper conductor 1.5 Sqmm PVC insulated unsheathed single core FRLSH cable 1100 volt grade, confirming IS 694 & colour code in conduit system of wiring, drawn through in and including non-metalic PVC surface conduit of size 20/25 mm or med grade as required as site, totally surface for floors / ceiling or fixed on surface of walls / columns / beam / tie beam etc by means of saddles and clips etc incl all conduit accessories / fittings such as tee/ elbow / sockets / junction boxes / inspection covers etc of heavy grade, ISI marked and surface PVC gang box.Wodden Box for mounting switch and sockets , for mounting of switches, sockets fan regulators etc incl 1.5 Sqmm FRLSH PVC insulated, unsheathed flexible multi stranded copper conductor cables as continuous earth wire connected to metallic bodies of luminaries / fans etc at one end and to common earth dolly at other end, suitable for One light/fan point controlled by one, one way switch, complete all as specified and directed.
All as per item No 26.00 here-in-above but with 2.5 Sq mm single core multistanded copper conductor cable for 3 pin 16 Amp socket outlet on independent board .
S&F socket outlet 2 in 1, 6 pin, 6 and 16 amp flush type, 230 Volts, ISI Marked complete all as specified and directed.
S&F switch piano flush type single pole one way 16 Amp, 230 Volts, ISI Marked complete all as specified and directed.
S&F Switch piano type, single pole, one way, 5/6 amps, 230 volts,ISI Marked complete all as specified and directed.
S&F Ceiling rose, three terminals, bakelite body, 230 volts, ISI Marked complete all as specified and directed.
Supply and fixing as MCB DB SPN (double door) 4 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall all as specified and directed by the Engr-in-Charge.
S&F MCB, B Curve type, 10 kA, 6 to 40Amp, SPN with over load and short circuit protection, ISI Marked complete all as directed.
S&F MCB, B Curve type, 10 kA, 6 to 32 Amp, Single Pole with over load and short circuit protection, ISI Marked complete all as directed.
Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp
S&F Bldg security LED Light Luminaire of 35 Watts having IP 65 protection fiting made out of pressure die cast Aluminium housing, operating Voltage 140-270 Volts with in built surge protectore, toughened glass with and including Sutaible size of GI Bracket including drilling holes, nuts & bolts 2 coats of red oxide primer on GI pipe and fixing with wall security light on building wall connecting cable complete all as directed.
S&F air circulator wall fans 230 V single phase oscillating 450 mm sweep , copper winding, Heavy duty motor, suitable for wall /pole/pipe /piller mounting all as directed.
S & F sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 4 Sqmm and one run of 4 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead duly coneected with earth dolly drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm, ISI marked Surface on wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc. complete as directed by Engineer-in-Charge. NOTE: Two runs of cable with one run of earth wire and PVC conduit shall be measured & paid for as one length.
Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of size 25 x 4mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed by the Engr-in-Charge. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
S&F and testing factory made sheet metal enclosure for MCB DB TPN 4 way 415 volt with double door, IP - 43 protection duly with fixed in wall/ concealed in wall /Surface on wall/pile/piller complete and making good disturbed surfaces of wall, floor etc including electric wire connection all as directed by Engineer-in-Charge.
S&F MCB TPN, 'C' Curve type , 415 Volts, 32 Amps with over load and short circuit protection, ISI Marked complete all as directed.
Supply, install ,Erection, testing and commissioning EOT crane 2 ton capacity Comprising following and Notes and Precommissioning factory test as per IS complete all as directed by EIC
Type: Single girder EOT crane
Class & Duty- Class II as per IS: 3177 & 807.
Span- 9 Mtr. Approx.
Height of lift - 5 Mtr.
Bay Length- 20 Mtr.
Speed:- a) Hoisting - 0-3m/min
b) Cross Travel- 0-15m/min
C) Long Travel - motorized
Motors:- All Motors are sq,Cage., crane duty, 40% CDF, IP-55, 150 St./hr., Cl. B/F insulation, foot mounted of BBL/Crompton/Hindustan make as per IS:325.
a) Hosting - 3.0Hp Sq cage
b) Cross Travel - 0.5Hp Sq cage x 1nos.
C) Long Travel - 1 hp Sq cage
Brake:- a) Hoisting - Dc Disc Type
b) Cross Travel - Dc Disc Type
C) Long Travel - Dc Disc Type
Limit Switch shall be provided for all motion.
Gears :- a) Hoisting - Hardened, Horizontal, Helical, Splash Lubricated
b) Cross Travel - Premium/ Hindustan Make Gear Box with warm Gear/ Bonifilioli
Ct wheel - dia 190mmx100,22208 L block
C) Long Travel - Premium/ Hindustan Make Gear Box with warm Gear/ Bonifilioli
Power Supply :- 415 Volts +/- 10%, 3 Phase 50 C/S AC
Control Voltage- 110 volts
Control Panel :- All contactor / overload relays Push button station etc. shall be operated Make like Siemens/Schneider
Wire Rope :- USHA MARTEIN MAKE 12 mm / 6x36 FMC, Fiber core180 kg/ MM Sq. As per IS :2266
No. of Fall:- 4 Falls
Hook :- With Thrust Bearing Plain shank Type as per IS:3815/4637/
Rope Drum :- seamless pipe
LT Wheel Size. :- 250 dia with 90 width
LT Rail Recommended:- 40x40 square rail
Plat Form:- Small Size Platform will be provided in Lt side for Maint. Purpose.
Operation:- Pendent Controlled
Painting:- Golden Yellow Synthetic Enamel/ dark blue /navy blue.
Notes : 1) Rate are demmed to be included for testing at site by OEM/Contractor in presence of User, JE E/M, AGE E/M, and GE, also realease of payment will be restricted as 10 % or as certain percentage decided by GE. After satisfactory Testing full payment will be release. Precommisioning test will be carrired out at manufacturer permisses/company as per IS. 2) OEM/Contractor shall provide drawing for gridder foundation, to be fabrication at time of Vehicle shed errection. 3) Gallentry portion for long travell (Forward & Backward ) of EOT crane is considered in the B/R -I portion for excution 4) OEM shall prvide drawings for grider foundation, to be fabrication at time of serviceable shed.
D DEV COMPANY
Harsh Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .