Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance 19 421 VRINDAVAN BUILDING OPP GOVT ITI HMT ROAD KALAMASSERY ERNAKULAM KERALA 683104 | ERNAKULAM | KERALA | 683104 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance C 1 707 1 NEW GIDC ESTATE GUNDLAV VALSAD GUJARAT 396035 UDYAM GJ 25 0001526 | VALSAD | GUJARAT | 396035 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
EMD Value
₹12,000
Closing Date
14 Sept 2020, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
DGM (P and P) UC
DGM (P and P) UC, FACT UDYOGAMANDAL, Eloor
Overhauling and Oil filtration work of Transformers in Petrochemical Plants 2020
2020_FACT_578862_1
05062/2020-21/E21971
Open Tender
Miscellaneous Works
Item Rate
30 days
FACT UDYOGAMANDAL
Please refer Tender documents.
4 documents required · 4 mandatory
₹50
Yes
FACT Ltd
₹12,000
Yes
15 Sept 2020
22 Aug 2020
15 Sept 2020
22 Aug 2020
14 Sept 2020
22 Aug 2020
90 days
Overhauling & Oil filtration work of Transformers in Petrochemical Plants-2020
Overhauling of TELK make 11/0.433 kV, 1.6 MVA Power Transformer of oil capacity-2280 litres and complete body painting. Scope of work: A) Preliminary inspection of the transformer. B) Draining of oil from the transformer. C) Disconnection and disassembling of bushings, conservator, pipe lines, cooling fins, tap-changer, Inspection windows, Explosion vent unit, main tank lid etc. D) Dismantling of conservator tank, Inspection, cleaning, varnishing the interior (if needed) and reassembling after replacement of all gaskets. E) Servicing of MOLG / Level gauge. F) Replacement of explosion vent diaphragm and wire guard together with gaskets. G) Flushing the interior of the body and windings with new oil to clean inside. H) Replacing of all old gaskets of bushings, radiators, drain plugs, conservator, Inspection windows buchholz relay, breather & pipe lines and main lid. I) Inspection of drain valves, radiator valves, HV , LV & Neutral bushings. (shall be replaced if found necessary). J). Dismantling , testing and servicing of Bucholz relay. K) Inspection and tightening the inner connections. L) Rinsing of radiators with oil and inspection. M) Reassembling of the transformer to its original shape. N) Vacuum oil filling of the transformer. O) Processing oil to the required level as per cl.5 of special conditions. P) Testing of oil as per cl.5 of special conditions. Q) Transformer body cleaning and spray painting of the exterior with one coat of epoxy primer and two coats of epoxy paint, including supply of all required materials. R) Pre-commissioning checks for energisation.
Overhauling of ITL make 11/0.433 kV, 1.6 MVA Power Transformer of oil capacity-1220 litres and complete body painting. Scope of work: A) Preliminary inspection of the transformer. B) Draining of oil from the transformer. C) Disconnection and disassembling of bushings, conservator, pipe lines, cooling fins, tap-changer, Inspection windows, Explosion vent unit, main tank lid etc. D) Dismantling of conservator tank, Inspection, cleaning, varnishing the interior (if needed) and reassembling after replacement of all gaskets. E) Servicing of MOLG / Level gauge. F) Replacement of explosion vent diaphragm and wire guard together with gaskets. G) Flushing the interior of the body and windings with new oil to clean inside. H) Replacing of all old gaskets of bushings, radiators, drain plugs, conservator, Inspection windows buchholz relay, breather & pipe lines and main lid. I) Inspection of drain valves, radiator valves, HV, LV & Neutral bushings. (shall be replaced if found necessary). J). Dismantling , testing and servicing of Bucholz relay. K) Inspection and tightening the inner connections. L) Rinsing of radiators with oil and inspection. M) Reassembling of the transformer to its original shape. N) Vacuum oil filling of the transformer. O) Processing oil to the required level as per cl.5 of special conditions. P) Testing of oil as per cl.5 of special conditions. Q) Transformer body cleaning and spray painting of the exterior with one coat of epoxy primer and two coats of epoxy paint, including supply of all required materials. R) Pre-commissioning checks for energisation.
Overhauling of TELK make 11/3.45 kV, 6.3 MVA power Transformer-4K (M/c Sl. No. 110089-3), Oil capacity-3215 litres and complete body painting. Scope of work: A) Preliminary inspection of the transformer. B) Draining of oil from the transformer. C) Disconnection and disassembling of bushings, conservator, pipe lines, cooling fins, tap-changer, Inspection windows, Explosion vent unit, main tank lid etc. D) Dismantling of conservator tank, Inspection, cleaning, varnishing the interior (if needed) and reassembling after replacement of all gaskets. E) Servicing of MOLG / Level gauge. F) Replacement of explosion vent diaphragm and wire guard together with gaskets.G) Flushing the interior of the body and windings with new oil to clean inside. H) Replacing of all old gaskets of bushings, radiators, drain plugs, conservator, Inspection windows buchholz relay, breather & pipe lines and main lid. I) Inspection of drain valves, radiator valves, HV , LV & Neutral bushings. (shall be replaced if found necessary). J) Dismantling , testing and servicing of Bucholz relay. K) Inspection and tightening the inner connections. L) Rinsing of radiators with oil and inspection. M) Replacement of gaskets and look glass of present Breather assembly. N) Reassembling of the transformer to its original shape. O) Vacuum oil filling of the transformer. P) Processing oil to the required level as per cl.5 of special conditions. Q) Testing of oil as per cl.5 of special conditions. R) Transformer body cleaning and spray painting of the exterior with one coat of epoxy primer and two coats of epoxy paint, including supply of all required materials. S) Pre-commissioning checks for energisation.
Transformer oil purification of TWO Numbers of TELK make 11/0.433 kV, 1.6 MVA Power Transformers of oil capacity-2280 litres each. Scope of work: A) Filtering and hot oil circulation till satisfactory oil test results is achieved. B) Testing of oil as per cl.5 of special conditions. Vacuum oil filling method shall be followed during final filling of oil up to conservator level. The contractor shall ensure NIL air locks during final oil filling.
Supply and replacing the ceramic bushes on LT side of Transformer, TELK make 11/0.433 kV, 1.6 MVA Transformer-8C (M/c Sl. No. 110091-4), Oil capacity-2280 litres. Rated current 3150A, Rated Voltage - 3.6KV, Confirming to IS 3347 & IS 2099 Note: This is an optional item and the supply is insisted only on actual requirement.
Supply and replacing the ceramic bushes on LT side of Transformer, ITL make 11/0.433 kV, 1.6 MVA Transformer-12K (M/c Sl. No. 9104), Oil capacity-1220 litres. Rated current 3150A, Rated Voltage - 3.6KV, Confirming to IS 3347 & IS 2099 Note: This is an optional item and the supply is insisted only on actual requirement.
Supply and replacing the ceramic bushes on LT side of Transformer, TELK make 11/3.45 kV, 6.3 MVA Transformer-4K (M/c Sl. No. 110089-3), Oil capacity-3215 litres. Rated current 2000A, Rated Voltage - 3.6KV, Confirming to IS 3347 & IS 2099 Note: This is an optional item and the supply is insisted only on actual requirement.
Supply and replacing the ceramic bushes on HT side of Transformer, TELK make 11/0.433 kV, 1.6 MVA Transformer-8C (M/c Sl. No. 110091-4), Oil capacity-2280 litres. Rated current 250A, Rated Voltage - 12/17.5KV, Confirming to IS 3347 & IS 2099 Note: This is an optional item and the supply is insisted only on actual requirement.
Supply and replacing the ceramic bushes on HT side of Transformer, ITL make 11/0.433 kV, 1.6 MVA Transformer-12K (M/c Sl. No. 9104), Oil capacity-1220 litres. Rated current 250A, Rated Voltage - 12/17.5KV, Confirming to IS 3347 & IS 2099 Note: This is an optional item and the supply is insisted only on actual requirement.
Supply and replacing the ceramic bushes on HT side of Transformer, TELK make 11/3.45 kV, 6.3 MVA Transformer-4K (M/c Sl. No. 110089-3), Oil capacity-3215 litres. Rated current 630A, Rated Voltage - 12/17.5KV, Confirming to IS 3347 & IS 2099 Note: This is an optional item and the supply is insisted only on actual requirement.
Supply of gaskets and oil seals for the transformer, TELK make 11/0.433 kV, 1.6 MVA Transformer-8C (M/c Sl. No. 110091-4), Oil capacity-2280 litres. Specifications of Rubberised Cork Gasket: The supplied gasket shall confirm to IS and following specifications: Type : C- very good oil resistant Grade: R C-70 C Sp. Gravity: 0.7- 0.8 Hardness: 70 +/- 5 irhd Compressibility@ 28 Kg/cm2- 30 +/- 5% for 6.3 mm 33 +/- 5 % for 9.6 mm Recovery@ 28 Kg/cm2- 80 (minimum)
Supply of gaskets and oil seals for the transformer, ITL make 11/0.433 kV, 1.6 MVA Transformer-12K (M/c Sl. No. 9104), Oil capacity-1220 litres. Specifications of Rubberized Cork Gasket: The supplied gasket shall confirm to IS and following specifications: Type : C- very good oil resistant Grade: R C-70 C Sp. Gravity: 0.7- 0.8 Hardness: 70 +/- 5 irhd Compressibility@ 28 Kg/cm2- 30 +/- 5% for 6.3 mm 33 +/- 5 % for 9.6 mm Recovery@ 28 Kg/cm2- 80 (minimum)
Supply of gaskets and oil seals for the transformer, TELK make 11/3.45 kV, 6.3 MVA Transformer-4K (M/c Sl. No. 110089-3), Oil capacity-3215 litres. Specifications of Rubberized Cork Gasket: The supplied gasket shall confirm to IS and following specifications: Type : C- very good oil resistant Grade: R C-70 C Sp. Gravity: 0.7- 0.8 Hardness: 70 +/- 5 irhd Compressibility@ 28 Kg/cm2- 30 +/- 5% for 6.3 mm 33 +/- 5 % for 9.6 mm Recovery@ 28 Kg/cm2- 80 (minimum)
Supply and fixing of new Silica gel air breather assembly with Indicating type Silica gel and air dash pot for 1600 kVA Transformer, Capacity – 3 Litres
Trans Electro
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .