Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.7 LAccepted-AOC | ₹12.7 L | L1 | Accepted-AOC Single lowest bidder |
| Sl No | Description | Qty | Unit | Kurian Joseph L1 |
|---|---|---|---|---|
| 1.00APPENDIX A - Renovation of Pump house | ||||
| 1.00 | 15.12.1:Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below | 2 | each | 379.56 ₹759.12 |
| 1.00 | 4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) | 0.94 | cum | 9,235.97 ₹8,718.76 |
| 1.00 | 5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform | 1.2 | sqm | 961.24 ₹1,153.49 |
| 1.00 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more | 7.2 | kilogram | 112.43 ₹809.50 |
| 1.00 | 21.1.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):
For fixed portionAnodised aluminium (anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15) | 29.7 | kg | 544.2 ₹16,162.74 |
| 1.01 | 9.48.1:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding | 9 | kg | 226.96 ₹2,042.64 |
| 1.01 | 50.9.15.5:Providing and fixing iron hooks and eyes: 100 mm | 12 | no | 15.19 ₹182.28 |
| 1.01 | 21.10:Providing and fixing double glazed hermetically sealed glazing in aluminium window, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant ) etc. as per specifications, drawings and direction of Engineer-in-Charge complete. | 4.5 | sqm | 5,032.78 ₹22,647.51 |
| 1.01 | 13.1.2:12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand). | 33 | sqm | 353.61 ₹11,669.13 |
Tender Value
₹12.7 L
EMD Value
₹31,766
Closing Date
10 Feb 2026, 3:00 pmClosed
Assistant Executive Engineer
Assistant Executive Engineer Minor irrigation subdivision Civil station Fourth floor Pala
The existing pump house and pond structures have deterioated due to age with corroded steel members and damaged windows and roofing restore the functionality and ensure sustainable irrigation to the adjoining paddy fields renovation of pump house
2026_Irrig_833056_1
RE-1 6770/AEE/MI/SUDN/PALA/2025-26
Open Tender
Civil Works - Others
180 days
MANJOOR
Please refer to tender documents
10 documents required · 10 mandatory
₹2,760
Yes
₹31,766
Yes
25 Mar 2026
3 Feb 2026
11 Feb 2026
3 Feb 2026
10 Feb 2026
3 Feb 2026
APPENDIX A - Renovation of Pump house
15.12.1:Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
21.1.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionAnodised aluminium (anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15)
9.48.1:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding
50.9.15.5:Providing and fixing iron hooks and eyes: 100 mm
21.10:Providing and fixing double glazed hermetically sealed glazing in aluminium window, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant ) etc. as per specifications, drawings and direction of Engineer-in-Charge complete.
13.1.2:12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).
13.46.1:Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
10.1:Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
12.51.1:Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screwscomplete :Ridges plain (500-600 mm)
12.50:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
APPENDIX B - Installation of Pumpset
OD33058/2025-2026:Supply, installation, testing, trial run and commissioning of submersible pumpset with efficiency not less than 50% capable of discharging 15 lps against total head of 73mtrs, with electric motor 25 HP suitable for handling fresh and silty water with maximum rpm 3000. The material of construction of the casing NICI and impeller shall be stainless steel CF8M with Chrome steel A276 type shaft. The prime mover for the pump should be 3 phase totally enclosed water cooled motor confirming to IS 9283, energy efficient standard rating suitable for 415V+/- 10%, 50Hz+/-5% connection with class F insulation, suitable cable confirming to IS 732:2019, length15m as per site conditions. Meter board with fuse as per KSEB specification and electrical inspectorate norms, prefabricated closed type control panel board completely wired and fitted with fully automatic star delta starter, main switch with ISI mark, Ammeter, volt meter, VSS, RYB indicating lamp, 6A MCB for RYB indication lamp, HRC fuse, neutral link, ELCB, suitable capacitor, SSP , 2 nos of earth fit suitable for motor as per KSEB specification and electrical inspectrate norms, with all necessary protection units and instrumentation. The rate inclusive of all the charges of supply, installation including petty civil works,including supporting structure bolting etc, trial run and commissioning .Suitable stainless steel rope for hanging the pump must also be provided. Above works shall be done as per the direction of departmental officer at site.
OD33083/2025-2026:Supply and laying of G.I. pipes complete as per direction of site engineer in charge. External work 80 mm dia nominal bore
OD33439/2025-2026:Providing and fixing gun metal non-return valve of approved quality (screwed end):80 mm nominal boreHorizontal
OD33440/2025-2026:Providing GI bend suitable for GI pipe 80mm and 125 mm NB including cost of materials.
OD33441/2025-2026:Providing and fixing G.I. Union in G.I pipe including cutting and threading the pipe and making long screws etc. complete. (125 mm nominal bore)
OD33590/2025-2026:Supply and laying of G.I. pipes complete as per direction of site engineer in charge. External work125 mm dia nominal bore
APPENDIX C - Renovation of Pond
60.2.2:Bailing out water Using 5HP Pump- Bailing out water with 5HP engine and pump set including conveyance to site and erection,cost of fuel, lubrication oil and other stores, pay of staff etc complete
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil
60.7.1:DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources)
4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns
8.9.1.2:Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete.Granite of any colour and shade
16.21:Engraving letters in hard stone
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1400740.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.05 MB
BOQ_1400740.xls
BOQ • 0.32 MB
SBD.pdf
Tender Documents • 2.23 MB