Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.7 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹38.9 L+₹18,161.70 (0.47%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹39.3 L+₹50,199.40 (1.30%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹40.9 L+₹2.2 L (5.57%)Rejected-Finance STREET NO 10 MALLOMAZRA ROAD BHAKHRA ENCLAVE PATIALA PB | PATIALA | PUNJAB | 140401 | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹41.4 L+₹2.7 L (6.90%)Rejected-Finance B 87 SHAM NAGAR KHAYALA ROAD NEW DELHI 110018 | NEW DELHI | NEW DELHI | DELHI | 110018 | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
13 Jul 2024, 6:00 pmClosed
GE (NORTH) TEZPUR
GE (NORTH) TEZPUR, C/O 99 APO
REPAIR /REPLACEMENT OF STREET LIGHTS, PERIMETER LIGHT, BLDGS EARTHING AND REPAIR MAINTENANCE OF DG SET WITH AMF PANEL, VOLTAGE STABILISER AND ALLIED WORKS AT AGE CHARDUAR UNDER GE (N) TEZPUR
2024_MES_660122_1
GE(N)/TEZ/2024-2025/8945
Open Tender
Civil Works
Item Rate
240 days
GE (NORTH) TEZPUR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (NORTH) TEZPUR
₹90,000
19 Oct 2024
15 Jun 2024
20 Jul 2024
15 Jun 2024
13 Jul 2024
29 Jun 2024
Amount
Servicing for DG set of capacity 62.5 KVA installed including Jobs to ensure its satisfactory performance and consumable items repair/replacement and the following items ie: suitable grade engine oil Oil filter, fuel filter, Air filter water separator Radiator cleaning with chemical change of fuel pipe change of fan belt of suitable size and change of hose pipe with clamp etc complete all as specified & directed by Engineer-in-charge.
Servicing for DG set of capacity 50 KVA installed including Jobs to ensure its satisfactory performance and consumable items repair/replacement and the following items ie: suitable grade engine oil Oil filter, fuel filter, Air filter water separator Radiator cleaning with chemical change of fuel pipe change of fan belt of suitable size and change of hose pipe with clamp etc complete all as specified & directed by Engineer-in-charge.
Servicing for DG set of capacity 40 KVA installed including Jobs to ensure its satisfactory performance and consumable items repair/replacement and the following items ie: suitable grade engine oil Oil filter, fuel filter, Air filter water separator Radiator cleaning with chemical change of fuel pipe change of fan belt of suitable size and change of hose pipe with clamp etc complete all as specified & directed by Engineer-in-charge.
Servicing for DG set of capacity 30 KVA installed including Jobs to ensure its satisfactory performance and consumable items repair/replacement and the following items ie: suitable grade engine oil Oil filter, fuel filter, Air filter water separator Radiator cleaning with chemical change of fuel pipe change of fan belt of suitable size and change of hose pipe with clamp etc complete all as specified & directed by Engineer-in-charge.
Servicing for DG set of capacity 12.5 KVA installed including Jobs to ensure its satisfactory performance and consumable items repair/replacement and the following items ie: suitable grade engine oil Oil filter, fuel filter, Air filter water separator Radiator cleaning with chemical change of fuel pipe change of fan belt of suitable size and change of hose pipe with clamp etc complete all as specified & directed by Engineer-in-charge.
Servicing for DG set of capacity 7.5 KVA installed including Jobs to ensure its satisfactory performance and consumable items repair/replacement and the following items ie: suitable grade engine oil Oil filter, fuel filter, Air filter water separator Radiator cleaning with chemical change of fuel pipe change of fan belt of suitable size and change of hose pipe with clamp etc complete all as specified & directed by Engineer-in-charge.
Supply only engine oil Grade 20 W 40 complete all as specified and as directed by the Engineer-in-Charge.
Supply & fixing Battery terminal leads of 3 mtr long to starter of Diesel engine provided with brass connector on one end and cable lug on other end (ISI Marked) complete all as specified and as directed by the Engineer-in-Charge.
complete removal of existing painting by scraping removel of rust etc, cleaning and applying spray painting with two coats of synthetic enamel paint after attending welding work to corroded portion over a coat of red oxide primer to the 62.5 KVA capacity of DG Sets with apple green tint for engine, smoke gray tint for alternator, black for foundation/bases frame and red for all guards including writing of SM/MES Number on Engine and Alternator all as specified and as directed by the Engineer-in-Charge.
complete removal of existing painting by scraping removel of rust etc, cleaning and applying spray painting with two coats of synthetic enamel paint after attending welding work to corroded portion over a coat of red oxide primer to the 50 KVA capacity of DG Sets with apple green tint for engine, smoke gray tint for alternator, black for foundation/bases frame and red for all guards including writing of SM/MES Number on Engine and Alternator all as specified and as directed by the Engineer-in-Charge.
complete removal of existing painting by scraping removel of rust etc, cleaning and applying spray painting with two coats of synthetic enamel paint after attending welding work to corroded portion over a coat of red oxide primer to the 40 KVA capacity of DG Sets with apple green tint for engine, smoke gray tint for alternator, black for foundation/bases frame and red for all guards including writing of SM/MES Number on Engine and Alternator all as specified and as directed by the Engineer-in-Charge.
complete removal of existing painting, by scraping removel of rust etc, cleaning and applying spray painting with two coats of synthetic enamel paint after attending welding work to corroded portion over a coat of red oxide primer to the 30 KVA capacity of DG Sets with apple green tint for engine, smoke gray tint for alternator, black for foundation/bases frame and red for all guards including writing of SM/MES Number on Engine and Alternator all as specified and as directed by the Engineer-in-Charge.
complete removal of existing painting by scraping removel of rust etc, cleaning and applying spray painting with two coats of synthetic enamel paint after attending welding work to corroded portion over a coat of red oxide primer to the 12.5 KVA capacity of DG Sets with apple green tint for engine, smoke gray tint for alternator, black for foundation/bases frame and red for all guards including writing of SM/MES Number on Engine and Alternator all as specified and as directed by the Engineer-in-Charge.
complete removal of existing painting by scraping removel of rust etc, cleaning and applying spray painting with two coats of synthetic enamel paint after attending welding work to corroded portion over a coat of red oxide primer to the 7.5 KVA capacity of DG Sets with apple green tint for engine, smoke gray tint for alternator, black for foundation/bases frame and red for all guards including writing of SM/MES Number on Engine and Alternator all as specified and as directed by the Engineer-in-Charge.
M&L of armature winding and field winding with super enamelled copper wire of appropriate gauge including varnishing of insulating material and heating up, testing etc, complete for DG set of capacity 40 to 62.5 KVA including taking out the old burnt windings. Installed at SFA Nandanam MES/SM No 108762 and STP inside Fort MES/SM No 013-6048-DG/06 all as specified and as directed by the Engineer-in-Charge. Note:(i). The super enamalled copper wire will be measured in Kg as unit. (ii). Qty of copper wire measured through BOD.
M&L in replacement of 12 Volts 92 AH batteries includig cell and plate change as per requirement and terminal and distal water complete all as specified and directed
M&L in replacement for 12 Volts 180 AH batteries includig cell and plate change as per requirements and terminal and distal water complete all as specified and directed
Supply & fixing in replacement Ammeter 0 to 60 Amps complete all as specified and directed
Supply & fixing in replacement Voltmeter 0 to 500 V complete all as specified and directed
Supply & fixing in replacement1.5sqmm PVC insulated multistranded copper conductor control cable complete all as specified and directed.
S & F in replacement earth continuity conductor or main earthing lead of size 25mm x 4mm galvanised mild steel strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. complete all as specified and as directed.
Supply and fixing in replacement 32 mm X 6 mm galvanised mild steel strip for horizontal conductors and down conductors including suitable design of fixing components of galvanised steel as per fig 28 of IS 2309: 1989 complete all as specified and as directed.
Earthing complete with galvanised steel earth plate electrode of size 60cm x 60cm x 6.3 mm thick burried directly in ground( earth pit not less than 2.25 m deep below the normal ground level) with top edge of the plate not less than 1.5m below normal GL connected to GI earth strip of size 25x4mm by means of bolts, nuts, check nuts washers of GI or steel all as shown in electrical plate No-3 of SSR Part I connected to machanery/equipments installed power house/sub station all as specified including testing on completion. Note No-1 the Quoted unit rate shall also include excavation earth work in any type of soil PCC (1:3:6) type C1 RCC pit 1:2:4 type B-1 cover reinforced with 8 mm dia CTD bars @ 150mm C/C both ways funnel with 15mm bore GI watering pipe 20mm dia bore GI protection pipe wire mesh and copper lugs complete all as shown in eletrical plate No-3 of SSR- 2009 (Part-1).
Surface dressing not exceeding 15 cm deep in soft/ loose soil complete all as specified and as directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or water supply pipes lines etc or not exceeding 10 sqm on plan and getting out in soft/ loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ soil complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
Supply & spreading sand cushioning to underground cable in trenches including, levelling hand punning down complete all as specified and directed Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.
M&L laying well burnt old size bricks, sub calss "B" bricks, straight or curved on plan, laid flat with width equal to length of brick, laid dry over electric cable for protection complete all as specified and directed.
Taking down the existing damage / unservicable LT under grund cable any description from trenches /walls/poles/floors etc and depositing where directed of size 6 sqmm 2 core complete all as specified and directed. (Note :- Excavation and earth work will be measured under respective items)
Taking down the existing damage / unservicable LT under grund cable any description of the followings size from trenches /walls/poles/floors etc and depositing where directed of size 6 sqmm 4 core complete all as specified and directed. (Note :- Excavation and earth work will be measured under respective items)
Taking down the existing damage / unservicable LT under grund cable any description of the followings size from trenches /walls/poles/floors etc and depositing where directed at site.and size 10 sqmm 4 core complete all as specified and directed. (Note :- Excavation and earth work will be measured under respective items)
Taking down the existing damage / unservicable LT under grund cable any description of the followings size from trenches /walls/poles/floors etc and depositing where directed of size 16 sqmm 4 core complete all as specified and directed. (Note :- Excavation and earth work will be measured under respective items)
Taking down the existing damage / unservicable LT under grund cable any description of the followings size from trenches /walls/poles/floors etc and depositing where directed at site.of size 25 sqmm 4 core complete all as specified and directed. (Note :- Excavation and earth work will be measured under respective items)
Laying only the under ground cable any type obtained from items Nos 32 above in trench/wall/floor etc are connecting with suitable cable lugs/sleevs etc and size 06 sqmm 2 core complete all as specified and directed by Engr-in Charge
Laying only the under ground cable any type obtained from items Nos 33 above in trench/wall/floor etc are connecting with suitable cable lugs/sleevs etc and size 6 sqmm 4 core complete all as specified and directed by Engr-in Charge
Laying only the under ground cable any type obtained from items Nos 34 above in trench/wall/floor etc are connecting with suitable cable lugs/sleevs etc and size 10 sqmm 4 core complete all as specified and directed by Engr-in Charge
Laying only the under ground cable any type obtained from items Nos 35 above in trench/wall/floor etc are connecting with suitable cable lugs/sleevs etc and size 16 sqmm 4 core complete all as specified and directed by Engr-in Charge
Laying only the under ground cable any type obtained from items Nos 36 above in trench/wall/floor etc are connecting with suitable cable lugs/sleevs etc and size 25 sqmm 4 core complete all as specified and directed by Engr-in Charge
Supply & Lay underground XLPE insulated armoured LT UG electric cable with aluminium conductor 1100V grade in trenches fixed on wall (or) passing through pipes/in floors including testing and commissioning of of size 06 sqmm 2 core complete all as specified and directed by Engr-in Charge .
Supply & Lay underground XLPE insulated armoured LT UG electric cable with aluminium conductor 1100V grade in trenches fixed on wall (or) passing through pipes/in floors including testing and commissioning of of size 06 sqmm 4 core complete all as specified and directed by Engr-in Charge .
Supply & Lay underground XLPE insulated armoured LT UG electric cable with aluminium conductor 1100V grade in trenches fixed on wall (or) passing through pipes/in floors including testing and commissioning of of size 10 sqmm 4 core complete all as specified and directed by Engr-in Charge .
Supply & Lay underground XLPE insulated armoured LT UG electric cable with aluminium conductor 1100V grade in trenches fixed on wall (or) passing through pipes/in floors including testing and commissioning of of size 16 sqmm 4 core complete all as specified and directed by Engr-in Charge .
Supply & Lay underground XLPE insulated armoured LT UG electric cable with aluminium conductor 1100V grade in trenches fixed on wall (or) passing through pipes/in floors including testing and commissioning of of size 25 sqmm 4 core complete all as specified and directed by Engr-in Charge .
M&L for laying 50 mm bore GI pipe, medium grade with all fittings, in crossing road/path or in pole/wall up to junction box/DBs/Main switch board etc including necessary clamping etc. complete all as specified and as directed by Engineer-in-Charge.
Supplying & laying 40 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supplying & laying in trenches 25 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supply and jointing straight through heat shrink joint kit for PVC/XLPE LT UG cable for sizes 10 to 16 sqmm 2/4 core complete including taking down and all as specified and directed
Supply and jointing straight through heat shrink joint kit for PVC/XLPE LT UG cable for sizes 20 to 25 sqmm 3.5/4 core complete including taking down and all as specified and directed
S&F in repair sub main wiring complete with two runs of 1.5 sqmm PVC insulated unsheathed single core multistrand copper conductor cable of 1100 volts grade drawn through new non metalic rigid PVC casing capping on wall alongwith accessories fixed on walls/floors/ceiling with one run of 1.5 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor all as specified and directed by Engr-in-Charge. Note:- Two runs of PVC insulated cable 1.5 sqmm + one run 1.5 sqmm of earth wire and one run of conduit including accessories shall be measured as one length.
S&F ceiling rose polycarbonate type three terminals complete all as specified and directed.
S&F in repair MCB distribution board made of CRCA sheet, powder coated paint comforming of IS 13032, single door fixed in switch boards/wall at various places of capacity 240volt 2 way MCB DB, SPN to IP 38 protection complete all as specified and directed by Engr-in Charge .
S&F in repair MCB of rating 240 Volts, MCB 5-32 Amp B curbe 10 KA complete all as specified and directed by Engr-in Charge
S&F in repairs street light Junction box PVC with operation suitable for accommodating and including heavy duty PVC connector block of 30 amps capacity three phase with one number single pole MCB 06 Amps complete including fixing to pole with suitable brackets, bolts/nuts in connecting cable and testing complete including taking down and all as specified and directed
Taking down the existing mounted LED security lights of gate lights/flood lights/ground lights of any size etc in carrying out repairs including checking luminous replacement of defective spares parts and checking all connection to make the fittings serviceable including replacement of connection while from junction box to fittings and rectifying the same after attending repairs complete all as specified and directed Note : Spare parts requires for making the lights functional will be measure and paid relevenat item
Supply only LED Driver 25 watts suitable for LED security/gate/flood/ground lights comnplete all as specified and directed.
Supply only LED Driver 45/60 wattss uitable for LED security/gate/flood/ground lights comnplete all as specified and directed
Supply only 1.5 sqmm 3 core copper conductor multistrand cable comnplete all as specified and directed
Supply only 15 mm PVC pipe with suitable clamp and nuts/bolts comnplete all as specified and directed
S&F in replacement for 25 W new generation energy saving environmental friendly long life versalile pressure die cast aluminium IP-66 Bldg security light with high power LED as light source complete all as specified and as directed by the Engineer-in-Charge
S&F in replacement for 45 W new generation energy saving environmental friendly long life versalile pressure die cast aluminium IP-66 Bldg security light with high power LED as light source complete all as specified and as directed by the Engineer-in-Charge
S&F in replacement for new generation energy saving garden light 8 W environmental friendly long life aesthetically desiged aluminium landscape luminire for diffused lighting with high power LED as light source complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in replacement, testing commissioning LED Post top latern luminaries outdoor type 60 Watts new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 roadway luminaire with high power LEDs as light source and electronic driver suitable for operation on AC single phase 220-240 Volts, 50 HZ supply, including provision of two single core 1.5 sqmm copper conductor PVC insulated, 1100 Volts, cable not less than 8 meter long etc, connectiing from junction boxes of poles complete all as specified & directed by Engr-in-Charge.
Supply, and fixing in replacement, testing and commissioning LED Post top latern luminaries outdoor type 20 Watts new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 roadway luminaire with high power LEDs as light source and electronic driver suitable for operation on AC single phase 220-240 Volts, 50 HZ supply, including provision of two single core 1.5 sqmm copper conductor PVC insulated, 1100 Volts, cable not less than 8 meter long etc, connectiing from junction boxes of poles complete all as specified and directed by Engr-in-Charge.
Supply and fix for bracket for single street light fitting with GI pipe medium grade 40 mm dia 2 m long bend to shape and double clamped with fabricated MS clamps as directed and fixed out side wall with bolts and nuts including painting including taking down old u/s bracket complete all as specified and directed by Engr-in Charge
Supply & Lay and connecting up Weather proof cable with aluminium conductor 1100V grade of size 10 sqmm 2 core complete including taking down old unservicable all as specified and directed by Engr-in Charge .
M/S GN ENTERPRISE (BID ID -3052307)
M/S RSB ENTERPRISES (BID ID -3052406)
gurchan singh & sons. (BID ID -3060543)
New Era Engineers (BID ID -3051935)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .