Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.6 CrAccepted-AOC QUADIRIYA MANZIL MARA CHENGALA KASARAGOD | CHENGALA | KASARAGOD | KERALA | ₹7.6 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹8.7 Cr+₹1.1 Cr (13.9%)Rejected-AOC | ₹8.7 Cr+₹1.1 Cr (13.9%) | L2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | M S BUILDER PRIVATE LIMITED L1 | S SIVASAMY L2 |
|---|---|---|---|---|---|
| 1.00CONSTRUCTION OF BRIDGE (LAND SPAN) FOR APPROACH ROAD AT VELIYANCODE SIDE | |||||
| 1.00 | 2.4.1.C:Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres Prestressed / Reinforced cement concrete grade M-20 & above. - By Manual Means | 14.66 | cum | 4,312.3 ₹63,235.57 Lowest | 4,312.3 ₹63,235.57 Lowest |
| 1.00 | 12.22:Providing Steel Liner 10mm thick for Curbs and 6 mm thick for Steining of Wells including Fabricating and Setting out as per Detailed Drawing. | 14.13 | MT | 1,60,788.94 ₹22,71,947.72 Lowest | 1,60,788.94 ₹22,71,947.72 Lowest |
| 1.00 | 55.18.4:Bored cast-in-situ M30 grade R.C.C. Pile excluding Reinforcement complete as per Drawing and Technical Specifications and removal of excavated earth with all lifts and lead upto 1000 m Using Concrete Mixer - Pile diameter-1000 mm | 450 | metre | 16,500 ₹74,25,000 Lowest | 16,528.54 ₹74,37,843 |
| 1.00 | 12.1.B.1:Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. Ordinary Soil - Depth upto 3m - Mechanical Means | 44.94 | cum | 101.75 ₹4,573.05 Lowest | 101.75 ₹4,573.05 Lowest |
| 1.00 | OD28364/2024-2025:Providing and laying in position cement concrete of specified grade excluding the cost of centering shuttering- All works up to plinth level -1:4:8 (1 Cement : 4 Coarse sand : 8 Graded stone aggregate 40 mm nominal size) as DSR. Details of cost for 1 cum | 2.34 | cum | 10,131.42 ₹23,687.26 Lowest | 10,131.42 ₹23,687.26 Lowest |
| 1.01 | 12.38.B.2:Cement Concrete for Reinforced Concrete in Pile Cap complete as per Drawing and Technical Specification R C C Grade M-25 - Using Batching Plant, Transit Mixer and Concrete Pump | 42.13 | cum | 10,628.93 ₹4,47,849.97 Lowest | 10,628.93 ₹4,47,849.97 Lowest |
| 1.01 | 13.5.C.P.1:Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications PCC Grade M25 - Using concrete Mixer - Height upto 5m | 76.26 | cum | 12,848.37 ₹9,79,816.7 Lowest | 12,848.37 ₹9,79,816.7 Lowest |
| 1.01 | 13.5.C.q.1:Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications PCC Grade M25 - Using concrete Mixer - Height 5m to 10m | 23.39 | cum | 13,315.58 ₹3,11,478.05 Lowest | 13,315.58 ₹3,11,478.05 Lowest |
| 1.01 | 14.1A.2.2.B:Furnishing and Placing Reinforced Cement Concrete Grade M20 Using Batching Plant, Transit Mixer, and Concrete Pump as per drawing and Technical Specification. For T-beam & slab - Height 5m to 10m | 85.45 | cum | 12,230.63 ₹10,45,119.56 Lowest | 12,230.63 ₹10,45,119.56 Lowest |
Tender Value
₹6.7 Cr
EMD Value
₹2 L
Closing Date
25 Mar 2025, 6:00 pmClosed
Director
Inland Navigation Directorate, Asramam, Kollam-2
GENERAL CSIND Construction of a Lock cum Bridge in CH 316.728 km of West Coast canal at Veliyancode in Ponnani Taluk in Malappuram District (PHASE 2 WORKS) General Civil Work 1
2025_Irrig_747723_1
IRR/IA/TR/1791/2022_5_1_1/1
Open Tender
Civil Works - Bridges
Item Rate
540 days
Veliyancode, Ponnani
Please refer Tender documents.
11 documents required · 11 mandatory
₹11,025
Yes
₹2 L
Yes
8 Sept 2025
7 Mar 2025
27 Mar 2025
7 Mar 2025
25 Mar 2025
7 Mar 2025
Amount
CONSTRUCTION OF BRIDGE (LAND SPAN) FOR APPROACH ROAD AT VELIYANCODE SIDE
2.4.1.C:Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres Prestressed / Reinforced cement concrete grade M-20 & above. - By Manual Means
12.22:Providing Steel Liner 10mm thick for Curbs and 6 mm thick for Steining of Wells including Fabricating and Setting out as per Detailed Drawing.
55.18.4:Bored cast-in-situ M30 grade R.C.C. Pile excluding Reinforcement complete as per Drawing and Technical Specifications and removal of excavated earth with all lifts and lead upto 1000 m Using Concrete Mixer - Pile diameter-1000 mm
12.1.B.1:Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. Ordinary Soil - Depth upto 3m - Mechanical Means
OD28364/2024-2025:Providing and laying in position cement concrete of specified grade excluding the cost of centering shuttering- All works up to plinth level -1:4:8 (1 Cement : 4 Coarse sand : 8 Graded stone aggregate 40 mm nominal size) as DSR. Details of cost for 1 cum
12.38.B.2:Cement Concrete for Reinforced Concrete in Pile Cap complete as per Drawing and Technical Specification R C C Grade M-25 - Using Batching Plant, Transit Mixer and Concrete Pump
13.5.C.P.1:Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications PCC Grade M25 - Using concrete Mixer - Height upto 5m
13.5.C.q.1:Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications PCC Grade M25 - Using concrete Mixer - Height 5m to 10m
14.1A.2.2.B:Furnishing and Placing Reinforced Cement Concrete Grade M20 Using Batching Plant, Transit Mixer, and Concrete Pump as per drawing and Technical Specification. For T-beam & slab - Height 5m to 10m
13.6:Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and Technical Specifications
14.2:Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications
13.14:Supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to IRC: 83 (Part-II) section IX and clause 2005 of MoRTH specifications complete including all accessories as per drawing and Technical Specifications.
14.4:Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications.
13.9.A:Back filling behind abutment, wing wall and return wall complete as per drawing and Technical Specification Granular material
14.6:Construction of precast RCC railing of M30 Grade, aggregate size not exceeding 12 mm, true to line and grade, tolerance of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post for expansion, complete as per approved drawings and technical specifications.
14.9:Drainage Spouts complete as per drawing and Technical specification
8.8:Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces
CONSTRUCTION OF BRIDGE (LAND SPAN) FOR APPROACH ROAD AT MARANCHERY SIDE
2.4.1.C:Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres Prestressed / Reinforced cement concrete grade M-20 & above. - By Manual Means
12.1.B.1:Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. Ordinary Soil - Depth upto 3m - Mechanical Means
12.22:Providing Steel Liner 10mm thick for Curbs and 6 mm thick for Steining of Wells including Fabricating and Setting out as per Detailed Drawing.
55.18.4:Bored cast-in-situ M30 grade R.C.C. Pile excluding Reinforcement complete as per Drawing and Technical Specifications and removal of excavated earth with all lifts and lead upto 1000 m Using Concrete Mixer - Pile diameter-1000 mm
OD29938/2024-2025:Providing and laying in position cement concrete of specified grade excluding the cost of centering shuttering- All works up to plinth level -1:4:8 (1 Cement : 4 Coarse sand : 8 Graded stone aggregate 40 mm nominal size) as DSR. Details of cost for 1 cum
12.38.B.2:Cement Concrete for Reinforced Concrete in Pile Cap complete as per Drawing and Technical Specification R C C Grade M-25 - Using Batching Plant, Transit Mixer and Concrete Pump
13.5.C.P.1:Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications PCC Grade M25 - Using concrete Mixer - Height upto 5m
14.1A.2.2.B:Furnishing and Placing Reinforced Cement Concrete Grade M20 Using Batching Plant, Transit Mixer, and Concrete Pump as per drawing and Technical Specification. For T-beam & slab - Height 5m to 10m
13.6:Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and Technical Specifications
14.2:Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications
13.14:Supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to IRC: 83 (Part-II) section IX and clause 2005 of MoRTH specifications complete including all accessories as per drawing and Technical Specifications.
14.4:Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications.
14.6:Construction of precast RCC railing of M30 Grade, aggregate size not exceeding 12 mm, true to line and grade, tolerance of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post for expansion, complete as per approved drawings and technical specifications.
14.9:Drainage Spouts complete as per drawing and Technical specification
8.8:Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces
CONSTRUCTION OF APPROACH ROAD AT MARANCHERY SIDE
OD30241/2024-2025:Providing stone columns 600 mm dia and disposal of MS Cone including hire charges, machinery etc complete including installation, driving to the required depth and testing as per the direction of departmental officers at site etc. complete Data from PWD , EST No : BR/2020/3149
OD30240/2024-2025:Providing sand pile 100mm dia and disposal of MS cone including hire charges of machinery etc complete including driving to the required depth and testing as per the direction of the departmental officers at site etc.complete
12.1.B.1:Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. Ordinary Soil - Depth upto 3m - Mechanical Means
13.10:Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification.
OD30034/2024-2025:Providing and laying in position cement concrete of specified grade excluding the cost of centering shuttering- All works up to plinth level -1:4:8 (1 Cement : 4 Coarse sand : 8 Graded stone aggregate 40 mm nominal size) as DSR. Details of cost for 1 cum
12.8.E.2.1:Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications. RCC Grade M25 - With Batching Plant, Transit Mixer and Concrete Pump
13.6:Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and Technical Specifications
S SIVASAMY (BID ID -2172008)
Bidder Name
S SIVASAMY
M S BUILDER PRIVATE LIMITED
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
BOQ.xls
BOQ • 0.33 MB
Tenderdocument.pdf
Tender Documents • 3.52 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .