| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.7 LAccepted-AOC VILLAGE GUHAR MAJHWAR P O UPPER BHAMBLA TEHSIL BALDWARA DISTT MANDI H P | MANDI | HIMACHAL PRADESH | 175001 | L1 | Accepted-AOC accepted | |
| 2 | L2₹10.7 L+₹2,637.20 (0.25%)Accepted-AOC | L2 | Accepted-AOC accepted | |
| 3 | L3₹11.8 L+₹1.1 L (10.2%)Accepted-AOC | L3 | Accepted-AOC accepted | |
| 4 | L4₹12.1 L+₹1.4 L (13.4%)Accepted-AOC | L4 | Accepted-AOC accepted |
Tender Value
₹12.4 L
EMD Value
₹24,801
Closing Date
18 Apr 2022, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Jal Shakti Division Sarkaghat Distt. Mandi HP
C/O Out let Chamber 14 Nos. Laying, Jointing and Testing GMS Pipe 150 mm dia 440 Rmt.
2022_HPIPH_59058_1
EE-JSD-SKT-Tender-2022-10-80 dated04.4.22
Open Tender
Civil Works
Item Rate
365 days
SARKAGHAT
Please refer Tender documents.
7 documents required · 7 mandatory
₹400
Executive Engineer
₹24,801
Yes
23 May 2022
4 Apr 2022
19 Apr 2022
4 Apr 2022
18 Apr 2022
4 Apr 2022
120 days
Amount
Excavation in foundation, trenches etc. in all kinds of soil such as pick work jumper work, blasting work in soft/hard rock, chiselling in soft/hard rock including wedging out upto all lift, stacking the excavated soil upto all lead clear from the edge of excavation and then returning the stacked soil in 15cm layers when requaired into plinths, sides of foundation etc. consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth as per direction and to the entire satisfaction of Engineer-in-Charge upto all lead and lifts.
Providing and laying cement concrete 1:4:8 (1 cement :4 sand :8 graded stone agg. 40mm nominal size) and curing complete excluding cost of form work in foundation and plinth in all lead and lifts as per direction and to the entire satisfaction of the Engineer-in-Charge.
Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30x30x5mm so as to give a fair finish including centring, shuttering strutting and propping etc. with wooden batten and ballies, in all heights of propping and centring below supporting floor to ceiling not exceeding 4 mtrs and removal of the same for insitu-reinforced concrete and plain concrete work in :-
Vertical surfaces such as wall (any thickness) partitions and the like including attached pillasters, buttresses plinth and string courses and the like in all leads and lifts as per direction and to the entire satisfaction of Engineer-in-charge.
Providing of Tor steel reinforcement for RCC work including bending ,binding and placing in position complete upto floor two level as per direction and to the entire satisfaction of Engineer-in-charge upto all lead and lifts.
Providing and laying cement concrete 1:1.5:3 (1 cement: 1.5sand: 3 graded crushed stone agg. 20mm nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work in :-
Foundation, footings, bases of columns and the like and mass concrete.
Wall ( Any thickness but bot less than 0.1 m thickness) atteched pillasters, buttresses, plinth and string courses, etc. from top of foundation level upto floor two level.
Laying jointing with welding and testing of GMS tube medium grade ( plain ended) in trenches of following dia and wall thickness as per IS: 1239-2001, including jointing the pipes with but welding at both the ends according to relevant BIS standards/approved specifications including manufacturing reducers/tapers, all short pieces and bends as per site requirement made from parent tubes (to be measured and paid alongwith pipes, Bends shall be manufactured in such a way that not more than 11/1/4 degree deflection is enused by a single cut and internal dia is not reduced including hydraulic testing to the enitre satisfaction of Engineer-in -charge. The damaged portion of galvanization due to welding shall be providing with anticorosive treatment by providing two coats of bituminous paint over priming coat as per AWWA specifications C-203-1978 (earthn work in treanches to be measured and paid for seperately).
150 mm dia wall thickness 4.80 mm
Providing/supply and fixing double flanged Cast Iron sluice valve of 150 mm dia of Leader /Kirloskar make conforming to IS: 14846/2000 with up to date amendment as per Class PN-1.00 to withstanding in normal seat pressure of 10.20 Kg/cm2 including champion sheet gasket 3mm thick, i/c welding with M.S. flanges table-5 complete to make the joints leak proof including carriage in all leads and lifts as per direction and to the entire satisfaction of Engineer-in-Charge.
SHITLA DEVI
Rajni Kuamri Thakur Contractor
BABITA THAKUR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .