| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.2 LAccepted-AOC 3 333 F M P ARCS VENGACHUVAD VAZHAKULAM P O MUVATTUPUZHA ERNAKULAM KERALA 686670 | MUVATTUPUZHA | ERNAKULAM | KERALA | 686670 | ₹11.2 L | L1 | Accepted-AOC lowest bidder |
| 2 | L2₹11.3 LRejected-AOC | ₹11.3 L | L2 | Rejected-AOC second lowest bidder |
| Sl No | Description | Qty | Unit | POZITIVE POWER INDIA PVT LTD L2 | Linsta Services L1 |
|---|---|---|---|---|---|
| 1.00SOLAR INSTALLATION | |||||
| 1.00 | OD74818/2025-2026:Supply and providing wall mounted on grid solar Power Conditioning Unit (PCU) of 200-1000
V DC Input voltage range or nearest range and 400V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz,
output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic
distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU
shall adjust the voltage and frequency level to suit the Grid Voltage Frequency and adustiable
for connecting time to grid as per KSEB norms, including Data Monitoring System complete
with accessories wifi/LAN connecting and connected application software etc. fixing on wall
using wall brackets and giving all connection as required (Make Growatt, Havells, Sofar, Evvo,
V-Guard, ABB, Polycab,panasonic, Deye) | 15 | kW | 9,460 ₹1,41,900 | 9,500 ₹1,42,500 |
| 1.00 | OD91675/2025-2026:Supply and providing Solar Photovoltaic Module Bi facial Mono Perc Half Cut/
Topcon Bi facial Mono perc Half Cut of capacity 540 Wp or higher size, manufactured in India, conforming to IS14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. fixing on existing steel frame work using nut bolts/screws etc in suitable direction at site condition and giving connection and inter connection wire tied using suitable steel wire tie as per the system string design an direction of department staff (make Adani, Vikram, Waaree, Tata, Havells,V-Guard) | 28 | each | 22,350 ₹6,25,800 | 25,000 ₹7,00,000 |
| 1.00 | OD74816/2025-2026:Supply & fixing 63/5 A, 5 VA, resin cast metering CT of accuracy class 0.2 | 3 | each | 507 ₹1,521 | 600 ₹1,800 |
| 1.00 | OD74817/2025-2026:Supply & installation of dust and vermin proof, 3 Phase Syntax Meter Board( GS-MB6545) and to fix KSEB meters, fuse units etc as required including fixing it on wall, making
good the damages colour washing etc. as required. | 1 | each | 7,100 ₹7,100 | 3,200 ₹3,200 |
| 1.00 | OD74812/2025-2026:Supplying and fixing Three phase 4wire KWh meter, 415V, 10 - 100 A range ,electronic type in
the existing meter board complete with connections, testing and commissioning etc. as required
(including testing if required, test certificate for submitting KSEB). | 1 | each | 19,250 ₹19,250 | 2,500 ₹2,500 |
| 1.01 | OD74802/2025-2026:Supplying and fixing Three phase 4wire HT TOD NET 240V class 0.2S CT OPERATED METER in the existing meter board complete with connections, testing and commissioning etc. as required for charging On grid plant after dismantling the existing KWH meter (including testing if required, test certificate for submitting KSEB)Make L and T | 1 | each | 14,987 ₹14,987 | 2,500 ₹2,500 |
| 1.01 | OD74815/2025-2026:Supply and providing wall mounted AC DB for on grid solar system for connecting Inverter AC side consists of a). Poly carbonate Enclosure IP65 protection with trasperant front cover with hinged door and termination arrangement, b). SPD Up1.5kV,Up 335VDC In 20kA, Imax 40kA and giving internal connection using suitable wire, c). 6 amps. to 32 amps. ratings, TPN MCB, 'C' curve, 10KA breaking capacity, giving all connection and DB fixing on wall using suitable screws and plugs etc as required. | 1 | each | 8,910 ₹8,910 | 17,500 ₹17,500 |
| 1.01 | 90.14.10.10:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16A -100A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC | 1 | no | 22,080 ₹22,080 | 15,000 ₹15,000 |
| 1.01 | 90.14.11.12:MCCB AccessoriesSupply and fixing shunt release for all voltage range up to 630A. | 1 | no | 2,472 ₹2,472 | 500 ₹500 |
Tender Value
Refer Docs
EMD Value
₹31,769
Closing Date
23 Mar 2026, 2:00 pmClosed
Assistant Executive Engineer
PWD Electrical Sub Division Ernakulam
DEPOSIT-Implementation of Solar Power Project in the Court complex Muvattupuzha-SITC of 15KW ON Grid solar plant at the Court complex Muvattupuzha-General Electrical Work-1
2026_PWD_847419_1
ESDE(ET)-213/AEE/2025-26
Open Tender
Electrical Works
180 days
Ernakulam
Please refer Tender documents.
10 documents required · 10 mandatory
₹2,760
₹31,769
6 Jul 2026
13 Mar 2026
25 Mar 2026
13 Mar 2026
23 Mar 2026
13 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1SOLAR INSTALLATION | |||||
| 1.001 | OD74818/2025-2026:Supply and providing wall mounted on grid solar Power Conditioning Unit (PCU) of 200-1000
V DC Input voltage range or nearest range and 400V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz,
output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic
distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU
shall adjust the voltage and frequency level to suit the Grid Voltage Frequency and adustiable
for connecting time to grid as per KSEB norms, including Data Monitoring System complete
with accessories wifi/LAN connecting and connected application software etc. fixing on wall
using wall brackets and giving all connection as required (Make Growatt, Havells, Sofar, Evvo,
V-Guard, ABB, Polycab,panasonic, Deye) | - | kW | - | - |
| 1.002 | OD91675/2025-2026:Supply and providing Solar Photovoltaic Module Bi facial Mono Perc Half Cut/
Topcon Bi facial Mono perc Half Cut of capacity 540 Wp or higher size, manufactured in India, conforming to IS14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. fixing on existing steel frame work using nut bolts/screws etc in suitable direction at site condition and giving connection and inter connection wire tied using suitable steel wire tie as per the system string design an direction of department staff (make Adani, Vikram, Waaree, Tata, Havells,V-Guard) | - | each | - | - |
| 1.003 | OD74816/2025-2026:Supply & fixing 63/5 A, 5 VA, resin cast metering CT of accuracy class 0.2 | - | each | - | - |
| 1.004 | OD74817/2025-2026:Supply & installation of dust and vermin proof, 3 Phase Syntax Meter Board( GS-MB6545) and to fix KSEB meters, fuse units etc as required including fixing it on wall, making
good the damages colour washing etc. as required. | - | each | - | - |
| 1.005 | OD74812/2025-2026:Supplying and fixing Three phase 4wire KWh meter, 415V, 10 - 100 A range ,electronic type in
the existing meter board complete with connections, testing and commissioning etc. as required
(including testing if required, test certificate for submitting KSEB). | - | each | - | - |
| 1.006 | OD74802/2025-2026:Supplying and fixing Three phase 4wire HT TOD NET 240V class 0.2S CT OPERATED METER in the existing meter board complete with connections, testing and commissioning etc. as required for charging On grid plant after dismantling the existing KWH meter (including testing if required, test certificate for submitting KSEB)Make L and T | - | each | - | - |
| 1.007 | OD74815/2025-2026:Supply and providing wall mounted AC DB for on grid solar system for connecting Inverter AC side consists of a). Poly carbonate Enclosure IP65 protection with trasperant front cover with hinged door and termination arrangement, b). SPD Up1.5kV,Up 335VDC In 20kA, Imax 40kA and giving internal connection using suitable wire, c). 6 amps. to 32 amps. ratings, TPN MCB, 'C' curve, 10KA breaking capacity, giving all connection and DB fixing on wall using suitable screws and plugs etc as required. | - | each | - | - |
| 1.008 | 90.14.10.10:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16A -100A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC | - | no | - | - |
| 1.009 | 90.14.11.12:MCCB AccessoriesSupply and fixing shunt release for all voltage range up to 630A. | - | no | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1432138.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.03 MB
Tendernotice_2.pdf
PDF • 0.05 MB
Tendernotice_3.pdf
PDF • 0.12 MB
Tendernotice_4.pdf
PDF • 0.74 MB
Tendernotice_5.pdf
PDF • 0.38 MB
Tendernotice_6.pdf
PDF • 0.04 MB
Tendernotice_7.pdf
PDF • 0.03 MB
viewnit.pdf
Tender Documents • 0.02 MB
BOQ_1432138.xls
BOQ • 0.26 MB
viewsbd.pdf
Tender Documents • 1.63 MB
Download all tender documents and submit your bid