Tender Value
Refer Docs
EMD Value
₹27,960
Closing Date
24 Nov 2020, 6:00 pmClosed
Garrison Engineer , Ramgarh
Ramgarh cantt
Repairing of internal wiring MCB with connected items at SRC GOLF AREA and certain units under GE Ramgarh
2020_MES_387761_1
8300/2098/E8
Open Tender
Civil Works
Item Rate
180 days
RAMGARH CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Ramgarh
₹27,960
Yes
2 Dec 2020
20 Oct 2020
26 Nov 2020
20 Oct 2020
24 Nov 2020
3 Nov 2020
Amount
Taking down carefully any type of point wiring (light, fan, socket bell or power) complete with all fitting such as batten, switch, ceiling rose, pendent, regulator, socket and brackets switch fuse etc removing materials from site and making good disturbed surfaces of walls, floors etc to match the existing surface all as directed .
M & L for point wiring for one light/ fan point/call bell controlled by one switch with 1100 volt grade PVC insulated FRLS 1.5 Sq mm multi stranded copper conductor cable with continuous earth wire of 1.5 Sq mm multi stranded copper conductor cable PVC insulated-unsheathed, drawn in & including concealed rigid non metallic PVC conduit medium grade with fittings (ISI marked) not less than 20 mm dia & sunken anodized pressed sunken boxes made out of not less than 1.0 mm thick sheet, covered with 2.8 mm thick laminated insulated cover make sheet for housing/fixing switches etc complete all as specified and directed.
do- all as per item No 2 above but 1.5 Sq mm for 5 Amp socket outlet on same board with 1.5 Sq mm earth wire complete.
do- all as per item No 2 above but 1.5 Sq mm for 5 Amp switch socket on independent board with 1.5 Sq mm earth wire complete.
do- all as per item No 2 above but 2.5 Sq mm for 15 Amp switch socket on independent board with 2.5 Sq mm earth wire complete.
Supply and fix ceiling rose three terminals PVC/ Polycarbonate, isolated body complete all as specified.
Supply and fix Socket outlet 2 in 1, 5 pin 5 Amp flush type universal 230 volt complete all as specified.
S&F Switch piano, flush type single pole, one way 05 Amp flush type universal 230 volt complete all as specified.
S&F Socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type universal 230 volt complete all as specified.
S&F Switch piano, flush type single pole, one way 15 Amp flush type universal 230 volt complete all as specified.
S & F angle holder complete all as specified and as directed.
S & F LED Lamp 9 Watt complete all as specified and as directed.
S&F Fan regulator electronic type 5 step, 230 volt complete all as specified.
S&F call bell Ding dong, AC 230 volts, single pole complete all as specified.
S&F bell push flush type 5 amp AC 230 volts, single pole complete all as specified.
S&F LED tube light batten suitable for LED T-8 lamps (Cat part No- DMLN1T8-16) pre-wired with LED tube rod 16 W ( Cat part No- LTT8-16) with extruded aluminium body PC diffuser and inbuilt driver of Crompton Greaves or equivalent model of Philips/ Wipro/GE including electrical connection from ceiling rose to light fitting by PVC flexible wire 23/.0076 mm size including earth connection complete.
S&F LED bulk head fitting 15 W with LED lamp , powder coated with die cast housing Code : SSK-BH-9W of syska LED or equivalent model of Philips/ Bajaj including electrical connection from ceiling rose to light fitting by PVC flexible wire 23/.0076 mm size including earth connection complete.
M & L Sub main wiring two single core 4.0 Sqmm PVC insulated FRLS multistanderd copper conductor cable and one run of 4.0 Sqmm PVC insulated unsheathed FRLS multistanderd copper conductor cable for earth wire drawn in & including concealed rigid non metallic PVC conduit medium grade with fittings (ISI marked) not less than 20 mm dia in ncluding taking down of existing conduit or batten complete and making good disturbed surface wall complete all as specified and as directed. Note : - Not : 2 runs of 4 Sqmm cable and 1 run of earth wire shall be measured as one unit length.
S&F sheet metal enclosures for DBs single pole & neutral 4 way double door with 200 Amp rated bus bar suitable to accommodate MCB and necessary electric cable connection through suitable lugs by crimping and making good disturbed area of wall complete all as specified & as directed.
S&F sheet metal enclosures for DBs single pole & neutral 8 way double door with 200 Amp rated bus bar suitable to accommodate MCB and necessary electric cable connection through suitable lugs by crimping and making good disturbed area of wall complete all as specified & as directed.
S&F sheet metal enclosures for DBs single pole & neutral 12 way double door with 200 Amp rated bus bar suitable to accommodate MCB and necessary electric cable connection through suitable lugs by crimping and making good disturbed area of wall complete all as specified & as directed.
S&F MCB single pole 6 to 32 Amp 240 V, ‘B’ Series, 10 KA, complete all as specified and as directed.
S&F MCB SPN, 20 to 40A 240V, ‘B’ Series, 10 KA complete all as specified and as directed.
Taking down old serviceable tube light fitting of any type from wall/ceiling and refixing the same in existing / other position after defect rectification. Note : Spares including fixing for repair will be include in the repairing cost.
S&F LED tube rod 18 Watt with electrical connection as required including testing complete
Supply 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular stranderd conductor 16 Sq mm including testing complete all as specified and directed.
M&L ,for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts check nuts & washers of galvanised iron or steel, protected by GI pipe 15 mm bore (light grade) and watering pipe 20 mm bore GI pipe (light grade) and PCC of chamber and coping shall in 1:3:6 type C-1 using 20 mm graded stone aggregate including excavation and earth work and removal of surplus soil and filling with black cotton soil upto ground level complete all as shown in electrical plate No 3 of SSR Pt-I, 2009 with CI cover 10mm thick of size 300x300mm with charcoal dust and common salt complete and earth lead connected to panel including testing complete all as specified and directed. Note : Earth test result should not less than one ohm.
S&F 3 M surface mounted with SP MCB 25 Amp & plug top with Indicator (Cat part No. PU3M-BT, Make North West) for AC protection complete all as specified
S&F metering panel suitable for opreation on 03 phase and netural,415 V, 50 Hz AC system (04 meters) including testing and refixing of meters, complete all as specified and as directed.
M/S SHAMBHU SHARAN SINGH
M/S ROHIT CONSTUCTION
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .