Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAdmitted-Fee/PreQual/Technical/Finance ATTUKAL BHAVANAM T C 20 1735 1 SASTHRI NAGAR EAST KARAMANA P O THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | 695002 | L1 | Admitted-Fee/PreQual/Technical/Finance | |
| 2 | L2₹1.1 Cr+₹1.2 L (1.12%)Admitted-Fee/PreQual/Technical/Finance | L2 | Admitted-Fee/PreQual/Technical/Finance | |
| 3 | L3₹1.2 Cr+₹4.5 L (4.04%)Admitted-Fee/PreQual/Technical/Finance VALIYAPARMBIL HOUSE POOKATTIRI EDAYUR POST MALAPPURAM 676552 | EDAYUR | MALAPPURAM | KERALA | 676552 | L3 | Admitted-Fee/PreQual/Technical/Finance | |
| 4 | L4₹1.2 Cr+₹12.4 L (11.1%)Admitted-Fee/PreQual/Technical/Finance MANHAKKATTE H MUDUR PO MALAPPURAM | MALAPPURAM | MALAPPURAM | KERALA | L4 | Admitted-Fee/PreQual/Technical/Finance | |
| 5 | L5₹1.3 Cr+₹15.2 L (13.7%)Admitted-Fee/PreQual/Technical/Finance SAI KRISHNA PLAVODU KODUNGANOOR P O VATTIYOORKAVU TRIVANDRUM 695013 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695013 | L5 | Admitted-Fee/PreQual/Technical/Finance |
| Sl No | Description | Qty | Unit | Velayudhan M L4 | VISAKH M R L1 | S.GOPAKUMAR L5 | HAMZA VALIYAPARAMBIL L3 | AJAY T L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00Supply of Materials | ||||||||
| 1.00 | 100.98.134:Supply of HDPE Pipe PE 100 (IS 4984/1995), 8kg, 90mm Outer Dia. | 3,000 | metre | 185 ₹5,55,000 | 166.01 ₹4,98,030 Lowest | 227.4 ₹6,82,200 | 172.71 ₹5,18,130 | 207.51 ₹6,22,530 |
| 1.00 | 100.98.440:Supply of CI Air Valve, Conforming to IS 14848 - 2000, Single Orifice, Small Orifice Type S1, Size 25mm. | 12 | no | 1,874 ₹22,488 | 1,684.64 ₹20,215.68 Lowest | 2,098.52 ₹25,182.24 | 1,752.66 ₹21,031.92 | 2,105.8 ₹25,269.6 |
| 1.00 | 100.98.457:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 80mm. | 20 | no | 4,424 ₹88,480 | 3,976.98 ₹79,539.6 Lowest | 4,758.24 ₹95,164.8 | 4,137.55 ₹82,751 | 4,971.22 ₹99,424.4 |
| 1.00 | OD34032/2026-2027:Specials for HDPE Pipe, 8kg, 90mm Outer Dia.(3 % of cost of pipe) | 3,000 | metre | 6 ₹18,000 | 4.98 ₹14,940 Lowest | 6 ₹18,000 | 5.18 ₹15,540 | 6.22 ₹18,660 |
| 2.00Working Charges | ||||||||
| 2.00 | 100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil. | 675 | cum | 604 ₹4,07,700 | 542.55 ₹3,66,221.25 | 594.12 ₹4,01,031 | 564.46 ₹3,81,010.5 | 295 ₹1,99,125 Lowest |
| 2.00 | 100.1.5:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50 m, in Ordinary Rock. | 225 | cum | 890 ₹2,00,250 | 800.29 ₹1,80,065.25 | 877.12 ₹1,97,352 | 832.6 ₹1,87,335 | 600 ₹1,35,000 Lowest |
| 2.00 | 18.12.8:Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work80 mm dia nominal bore | 900 | metre | 1,026 ₹9,23,400 | 922.06 ₹8,29,854 Lowest | 1,114.01 ₹10,02,609 | 959.28 ₹8,63,352 | 1,152.57 ₹10,37,313 |
| 2.00 | OD33958/2026-2027:Inter connection of newly laid PVC /GI line with existing line of HDPE Pipes of all classes and sizes of pipes including,earth work,required pipe and HDPE specials for interconnecting with PVC/GI Pipes etc.complete as per direction of Engineer in charge | 30 | no | 2,836 ₹85,080 | 2,547.05 ₹76,411.5 Lowest | 2,887.12 ₹86,613.6 | 2,649.89 ₹79,496.7 | 3,000 ₹90,000 |
Tender Value
₹1.4 Cr
EMD Value
₹50,000
Closing Date
24 Nov 2026, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
KWA, PH Circle, Palakkad
Jal Jeevan Mission (JJM)-WSS to Kottayi Augmentation of pipeline in the distribution network using GI and HDPE pipe for completing FHTC work in Kottayi Panchayath-Pipeline Work
2026_KWA_889491_1
13/26-27/SE/PHC/PKD
Open Tender
Civil Works - Water Works
Item Rate
180 days
Kottayi
Please refer Tender documents.
10 documents required · 10 mandatory
₹5,515
Yes
₹50,000
Yes
25 Nov 2026
17 Nov 2026
25 Nov 2026
17 Nov 2026
24 Nov 2026
17 Nov 2026
120 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply of Materials | |||||
| 1.001 | 100.98.134:Supply of HDPE Pipe PE 100 (IS 4984/1995), 8kg, 90mm Outer Dia. | 3,000 | metre | - | - |
| 1.002 | 100.98.440:Supply of CI Air Valve, Conforming to IS 14848 - 2000, Single Orifice, Small Orifice Type S1, Size 25mm. | 12 | no | - | - |
| 1.003 | 100.98.457:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 80mm. | 20 | no | - | - |
| 1.004 | OD34032/2026-2027:Specials for HDPE Pipe, 8kg, 90mm Outer Dia.(3 % of cost of pipe) | 3,000 | metre | - | - |
| 2Working Charges | |||||
| 2.001 | 100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil. | 675 | cum | - | - |
| 2.002 | 100.1.5:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50 m, in Ordinary Rock. | 225 | cum | - | - |
| 2.003 | 18.12.8:Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work80 mm dia nominal bore | 900 | metre | - | - |
| 2.004 | OD33958/2026-2027:Inter connection of newly laid PVC /GI line with existing line of HDPE Pipes of all classes and sizes of pipes including,earth work,required pipe and HDPE specials for interconnecting with PVC/GI Pipes etc.complete as per direction of Engineer in charge | 30 | no | - | - |
stage.html
html • 0.02 MB
finance_1520274.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
KWAGeneralConditionsforeTenderingV5.pdf
PDF • 0.69 MB
Tendernotice_1.pdf
PDF • 1.82 MB
TenderdocTNo13.pdf
Tender Documents • 14.07 MB
BOQ_1520274.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .