Loading…
Loading…
Tender Value
₹9.0 Cr
EMD Value
₹9.0 L
Closing Date
5 Aug 2026, 6:00 pm
The Managing Director
Development of Lift, Parking and Other Tourist Facilities at Uperkot Fort, at Junagadh, Gujarat Phase- 2
324281
2026-Uperkot Fort Junagadh
Open
Civil - All
Works
Gandhinagar
2 documents required · 2 mandatory
₹12,000
Tourism Corporation of Gujarat Limited
₹9.0 L
15 Jul 2026
15 Jul 2026
15 Jul 2026
5 Aug 2026
15 Jul 2026
Name Of Work:- Development of Lift, Parking and Other Tourist Facilties at Uperkot Fort, at Junagadh, Phase -2
Per / SOR Rate 2024-25
Sr. No. Description of Item qty Total Amount
Sr. No. Description of Item qty Total Amount
Unit With 1% L.C.
Dismentaling the existing structure including removing and stacking the
dismentelled materials as and where directed. (B) Rubble Masonry
Excavation for foundation upto 1.5 m depth including sorting out and stacking of
2 useful materials and disposing off the excavated stuff upto 50 Meter lead.(E) Cmt 9131.00 627.47
Excavation for foundation for depth from 1.5 m to 3.0 m including sorting out
3 and stacking of useful materials and disposing off the excavated stuff upto Cmt 389.00 651.26
50 Meter lead.(E) Hard Rock
Filling available excavated earth (excluding rock) in trenches. plinth, sides of
4 foundations etc. in layers not exceeding 20 cm. in depth consolidating each Cmt 2200.00 136.92
disposited layer by ramming and watering.
Filling in foundation and plinth with murrum or selected soil in layers of 20cm.
thickness including watering, ramming and consolidating etc. complete.
Providing & laying Controlled cement concrete M-150 and finishing smooth with
curing etc. complete including the cost of formwork but excluding the cost of
reinforcement for reinforced concrete work in foundation footing base of
columns and mass concrete
Providing & laying Controlled cement concrete 1:2:4 (1-Cement :2 -Coarse sand :
4 -graded stone aggregates 20 mm nominal size) and finishing smooth with
curing etc. complete including the cost of formwork but excluding the cost of
reinforcement for reinforced concrete work in pcc in below ground/plint beam
Providing & laying Cement Concrete 1:4:8 (1 Cement :4 Coarse sand :8 hand
8 brocken stone aggregates of 40mm nominal size) in plinth and curing complete Cmt 1198.00 2,769.69
excluding cost of formwork.
Providing and laying controlled cement concrete M.250 and curing complete
including the cost of formwork but excluding cost of reinforcement for
reinforced concrete work in (A) Foundations footings, base of columns,
Retaining Wall base, Piling Work (Incl. Cost of Liner / Bentonite and pile testing
as per instructions of structural engineer) Complete Fair Finish, as per detailed
& directed by Architect / Consultant & and directed by EIC.
Providing & laying Controlled cement concrete for plinth beam(tie beam), Ground
beam with M-250 cement concrete including finishing smooth with curing etc.
complete including the cost of formwork but excluding the cost of
reinforcement for any cross sectional area of beam.
Providing and laying controlled cement concrete M-250 (1:1:2 ; 1 Cement :1.
coarse sand : 2 hand Brocken stone aggregates 20mm nominal size ) & including
cost of necessary, compacting with vibrator curing centring & shuttering in true
line and level etc, but excluding the cost of formwork & reinforcement for RCC
work in (D) For Columns for any type of cross sectional area up to Floor Two
lvl.… etc., for any type of cross section area complete as directed by E. I. C.
Providing & laying Controlled cement concrete M-250 for R.C.C.lintel including
12 finishing smooth with curing etc. complete including the cost of formwork but Cmt 13.00 6,131.71
excluding the cost of reinforcement.For all floors
Providing TMT Bar FE 500D reinforcement for R.C.C. work including bending,
binding and placing in position complete upto floor two level
Structural steel work ( Confirming to IS 4923-1997) riveted, bolted or welded in
builtup for all type sections, in framed work, including cutting, hoisting, fixing in
14 position and applying a priming coat of approved steel primer all complete as per kg 71408.00 131.83
the structural designs and directions of Engineer in charge.Column, Slab, Beam,
Strucure, All types Of Plate.
(ii) Uncoursed Rubble Masonry with hard stone of approved quality in
15 foundations and plinth and up to Plinth in Cement Mortar 1:5 (1-cement : 5 Cmt 74.00 2,628.91
coarse sand including levelling up etc. complete
Pointing on Uncoursed stone masonry with cement mortar 1:3 (1-cement : 3-
coarse sand)(B) Ruled pointin
Providing and fixing pre-cast Rubber Dye / steel Dye inter locking concrete block
60mm thick with grade of concrete M300 pnumatic compressed / vibrated
17 mechanically and as per approved design Confirming to IS 15658 : 2006 Smt 214.00 706.83
including 35 mm Sand layer for levelling and filling the joint with sand in proper
line and level as per guidlines of IRC : SP 63-2018 etc. Complete.
Providing and fixing pre-cast concrete kerb stone of gray cement based concrete
block 30cm length,30cm height and 15cm thick of M250 grade concret as per
18 approved design and including excavation for fixing in proper line and Rmt 1126.00 374.92
level,filling the joint with C:M 1:3 (1cement:3fine sand) etc complete. (upto
Providing and fixing 1.20 Metre high fencing with 2.0 Metre long M.S. Angle
posts 40mm x 40 mm x6 mm and oil painting 3 coats fixed at 2.5 Mt,C/c. with five
Horizontan lines and two diagonals of galvanised steel barbed wire weighting
9.38 Kg. per 100 Metre, strained and fixed to posts with G.I,staples including
fixing the postsin ground with 0.5 M x 0.5.M x 0.5 M. block in C.C1:5:10 etc
Vacuum dewatering flooring works with anti-skid grooves cutiing & Filling:
Providing and laying M20 grade concrete for no slippery, Vacuum dewatered
flooring including cleaning, trimming, watering the surface, laying in strips to
20 required levels, travelling, smoothening etc., complete . For Serrated finish - For Cum 1168.00 7,110.40
Ramps, Using RMC external source/within the site
(Cement shall not be supplied free of cost by the Employer). Average 100mm
Providing and Fixing 6 mm thick Lexan Polycarbonate multi wall roofing sheet
21 fixed with hilti screw and rubber silicon sealer and alluminium strip of size 50 x 3 Smt 54.00 1,441.90
mm etc completeas directed by Engineer in charge.
Providing and laying Vitrified tiles 8 to 10 mm thick , 24'' x 24'' in skrting risers of
22 steps and dedo on 10mm thick cement plaster 1:3 (1-cement : 3-coarse sand) and Smt 313.00 1,195.02
jointed with white cement slurry
Providing and laying Vitrified tiles 8 to 10 mm thick , in skrting risers of steps
23 and dedo on 10mm thick cement Smt 22.00 1,592.40
plaster 1:3 (1-cement : 3-coarse sand) and jointed with white cement slurry
This proposal covers the providing, fabrication, supply, and installation of a high-
performance Portable Prefabricated Security Cabin at Uparkot Fort, Junagadh,
for Tourism Corporation of Gujarat Ltd. (TCGL). The cabin measures
approximately 3.0 m x 3.0 m x 2.8 m (10’ x 10’ x 9’) and is constructed with
GreenPro-certified materials aligned with sustainability and carbon footprint
offsetting mandates.
The design integrates seven specialized wall sections ensuring superior fire
resistance, thermal insulation (R value 10), termite-proofing, moisture resistance,
frost protection, and full recyclability for sustainability throughout the lifecycle.
Structural integrity is ensured through a GI light gauge frame fabricated via CNC
24 laser cutting and NC bending, engineered for wind speeds up to 180 km/h, No 1.00 6,68,620.00
seismic zone 4 stability, and load-bearing capacity of 320 kg/m².
The cabin features a 2-foot extended roof front side and 1 foot on all sides with
roofing assemblies that are fire-, heat-, and water-resistant, finished with durable
bitumen and UV-resistant membranes. Openings utilize powder-coated Dumal
aluminum windows (5 mm toughened glass) and corrosion-resistant solid WPC
doors, with ISI-approved FRLS wiring and energy-efficient LED lighting and
HVAC points installed. Certification to ISO 9001:2015 ensures quality and
consistency, backed by a comprehensive 10-year warranty covering materials
and workmanship. Furniture consisting of 5 feet table with drawers and locks
and rolling chair and sofa.
This proposal covers the providing, fabrication, supply, and installation of a high-
performance Portable Prefabricated Ticket Window Unit along with office space,
waiting area and washroom at Uparkot Fort, Junagadh, for Tourism Corporation
of Gujarat Ltd. (TCGL). The unit measures approximately 12.0m x 6.0m x 2.8m
(40’ x 20’ x 9’) and is constructed with GreenPro-certified, high-sustainability
materials to align with modern carbon footprint and eco-compliance mandates.
The design integrates seven specialized wall sections ensuring superior fire
resistance, thermal insulation (R value 10), termite-proofing, moisture resistance,
frost protection, and full recyclability for sustainability throughout the lifecycle
by using Greenpro certified Silica Composite Boards. Structural integrity is
ensured through a GI light gauge frame fabricated via CNC laser cutting and NC
bending, engineered for wind speeds up to 180 km/h, seismic zone 4 stability,
and load-bearing capacity of 320 kg/m².
The unit features a 2-foot extensions on all 3 sides, incorporating roofing
assemblies that are fire-, heat-, and water-resistant, finished with high-
performance UV-reflective PU/elastomeric coatings ensuring superior durability
and thermal protection. Openings include powder-coated aluminum windows
with 5 mm toughened glass/fluted glass, equipped with powder-coated MS safety
grills, and corrosion-resistant solid WPC doors with secure locking mechanisms.
The electrical system comprises ISI-approved FRLS wiring, modular DB with
MCB/ELCB protection, energy-efficient LED lighting panels, and pre-wired HVAC
points for future installations. The entire fabrication and installation comply with
ISO 9001:2015 quality standards, backed by a 10-year comprehensive warranty
covering materials and workmanship.
Interior furnishings include a custom-engineered 5 ft ticket counter with laminate
finish, secure drawers, and locks, ergonomic adjustable rolling chairs, spacious
This proposal covers the providing, fabrication, supply, and installation of a high-
performance Portable Prefabricated Café with Washroom at Uparkot Fort,
Junagadh, for Tourism Corporation of Gujarat Ltd. (TCGL). The unit measures
approximately 12.0m x 6.0m x 2.8m (40’ x 20’ x 9’) and is constructed with
GreenPro-certified, high-sustainability materials to align with modern carbon
footprint and eco-compliance mandates.
The design integrates seven specialized wall sections ensuring superior fire
resistance, thermal insulation (R value 10), termite-proofing, moisture resistance,
frost protection, and full recyclability for sustainability throughout the lifecycle
by using Greenpro certified Silica Composite Boards. Structural integrity is
ensured through a GI light gauge frame fabricated via CNC laser cutting and NC
bending, engineered for wind speeds up to 180 km/h, seismic zone 4 stability,
and load-bearing capacity of 320 kg/m².
The unit features a 2-foot extensions on all 3 sides, incorporating roofing
assemblies that are fire-, heat-, and water-resistant, finished with high-
performance UV-reflective PU/elastomeric coatings ensuring superior durability
and thermal protection. Openings include powder-coated aluminum windows
with 5 mm toughened glass/fluted glass, equipped with powder-coated MS safety
grills, and corrosion-resistant solid WPC doors with secure locking mechanisms.
The electrical system comprises ISI-approved FRLS wiring, modular DB with
MCB/ELCB protection, energy-efficient LED lighting panels, and pre-wired HVAC
points for future installations. The entire fabrication and installation comply with
ISO 9001:2015 quality standards, backed by a 10-year comprehensive warranty
covering materials and workmanship.
Dry stone cladding to lift area walls, comprising natural stone panels
mechanically fixed to a concealed metal framing and support system. Stone
panels to be installed without wet trades, using proprietary anchors or fixings to
allow for tolerances, ventilation, and differential movement. System to include
non-combustible framing, backing substrate, fire-rated insulation where required,
and neatly detailed edges, corners, and junctions around lift doors, reveals, and
service panels. All materials and installation to comply with relevant fire safety,
structural, and durability requirements.includes erection of the aluminum
substructure with MS fabrication, Stone, Stone Water Repellent coating, labour
for installation such as stone cutting, kerfing, and fixing, and the supply of
aluminum horizontal channels, SDS, UPVC packing, and MS pipes with red oxide
paint. It also includes the supply and application of stone sealer, Hilti HRD-HR2
M10 × 100 mm anchors(if required), safety materials, and allowance for
unforeseen requirements.
Fabricating, supplying and fixing in position SS railing for staircase and balcony
with brush finish and 304 grade as per Indian Standrd and detailed drawing
including grinding, cleaning and filling the welded spots with SS finish (Only
Length will be paid for payment heigth max.1.0 mt.). including welding, grinding,
28 buffing, polishing and making curvature (wherever required) and fitting the same RMT 80.00 3,535.00
with necessary stainless steel nuts and bolts complete, i/c fixing the railing with
necessary accessories & stainless steel dash fasteners , stainless steel bolts
etc., of required size, on the top of the floor or the side of waist slab with suitable
arrangement as per approval of Engineer-in-charge.The Work to be executed as
per consultant drawing .
Providing and fixing to wall, ceiling and floor galvanised Mild steel tubes
29 (Medium grade) of the following nominal bore, tube fitting and clamps including Rmt 10.00 397.97
making good the wall ceiling and floor.(C) 25mm
Providing and fixing to wall, ceiling and floor galvanised Mild steel tubes
30 (Medium grade) of the following nominal bore, tube fitting and clamps including Rmt 10.00 249.99
making good the wall ceiling and floor.(A) 15mm
Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR
13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of
following dia. nominal bore tube fittings and clamps including making good the
wall, ceiling and floor etc. complete. [C] 25 mm.
Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR
13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of
32 following dia. nominal bore tube fittings and clamps including making good the Rmt 1.00 168.67
wall, ceiling and floor etc. complete.[A] 15 mm.
Providing and fixing Gun metal check or non-return fullway wheel valve.(C)
Providing and fixing Gun metal check or non-return fullway wheel valve.(A)
Providing and fixing wash down water closet (European type, W.C. Pan) with
integral P or S trap including
35 jointing the trap with soil pipe in Cement Mortar 1:1 (1-Cement : 1-fine sand) Each 2.00 1,343.38
(Seal and cover to be measured and paid for separately)(A) vitreous China
Pattern :(i) in white colour
36 Providing and fixing G.I. inlet connection for flush pipe with W.C. Pan Each 2.00 27.78
Providing and fixing plastic seat and cover for wash down water closer with C.P.
37 brass hinges and rubber buffers. (B) Black plastic seal and cover. Each 2.00 288.45
Providing and fixing washbasin with single hole for pillar tap with C.I. or M.S.
brackets painted white including sutting holes and making good the same but
excluding fittings.(A) Vitreous China:(ii) Flat Back washbasin 550 mm x v 400mm
size. (i) In white colour
39 Providing and fixing C.P. brass waste for washbasin or sink. (A) 32mmdia. Each 2.00 67.24
Providing and fixing Rubber plug for sink or wash basin.
Providing and fixing chromium plated, bottle trap with necessary couplings of
approved quality for wash basin.
Providing and fixing pillar tap, capstan head, screw down high pressure with
screws, shanks and back nuts. (i) 15mm dia.
Providing and fixing screw down bib taps of following size.(A) Brass screw down
bib tap polished bright. (i) 15mm dia
Providing and fixing Urinal of approved quality including connection with trap
44 and with integral longitudinal flush pipe.(A) Squating plate pattern white Each 4.00 1,615.72
earthenware 550mm x 300mm.
Providing and fixing 12.5 Litres low level flushing cistern with a pair, of C.I. or
Mild brackets, complete with fittings such as lead valve less syphon, 15mm
nom.nal size brass ball valve with polythene float, C.P brass handle unions and
45 couplings for connections, with inlet, outlet and overflow pipes, 40mm dia. Each 2.00 2,346.92
porcelain enamelled flush bend including cutting holes in walls and making good
the same connecting the flush bend with cistern and closet (overflow pipe to be
measured and paid for separately)(A) Vitreous China (I) In white colour
Providing and fixing chromium plated brass half trun flush cock of approved
quality including fixing in pipe line etc. complete.(i) 20mm dia.
Fixing, Testing and Commissioning C.P. brass Ablution health faucet assembly
47 comprising hand held shower with 8 mm dia flexible tube with mounting bracket Each 2.00 157.29
fixed on wall complete.
Providing and fixing C.P. brass towel rail comlete with C.P. brass brackets fixed
48 to wooden plugs with C.P. brass scews.(B) 600mm x 20mm size. or 20mm Each 4.00 610.32
inlet.(A) 100mm dia. Each
49 Providing and fixing toilet paper holder.(A) C.P. Brass Each 2.00 423.75
Providing erecting and fixing double coated ISI water tank of required capacity
each with all necessary fittings and connection etc. complete on terrace
Providing and fixing SWR pipes PVC 10kg for soil and waste pipes.for following
Fixing Heavy class SS single piece grating 150 x 150 mm size of approved
52 make, including setting in floor with cement mortor to match with floor finish as Each 2.00 36.61
per architect requirements.
Providing and fixing cast iron spigot and socket soil, waste and ventilating pipes
of the following nominal size.(B) 75mm dia.
Providing and fixing cast iron spigot and socket soil, waste and ventilating pipes
of the following nominal size.(C) 100mm dia.
Providing laying (to level or slopes) and jointing reinforced concrete Light duty
non-pressure pipes I.S. class NP2 of the following internal diameter with collars
and butt ends prepared for collar joints including testing of joints complete.(E)
Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1-cement :2-coarse sand
: 4-graded stone aggregate 20mm nominal size) foundation concrete 1:3:6 mix (1-
cement : 3- coarse sand :6-Brick bats 40 + 50mm size) inside plastering 15mm
thick with Cement Mortar 1:3 (1-Cement : 3-coarse sand) finished with a floating
coat of neat cement and making channels in cement concrete 1:2:4 mix (1-
Cement :2-Coarse sand :4-stone aggregate 20mm nominal size) finished smooth
complete including curing and festing (i) Inside size 900mm x 1200mm and 1.5M.
deep including C.I. cover with frame size 560mm diameter total weight of cover
and frame to be not less than 128 kgs. (Wt. of cover 64 Kg. and Wt. of frame
Kg.)(A) With 230mm thick walls of brick msonry using brick having crushing
strength not less than 35Kg. / Sq.cm. in Cement Mortar 1:5 (1- Cement: 5-Coarse
sand) (1) A type depth 0.90 Metre for 150mm diameter sewer.
Constructing Manhole with R.C.C. top slab in 1:2:4 mix Constructing brick
masonry chamber for underground C.I. Inspection chamber and bends with
bricks having crushing strength not less than 35Kg/Cm2 in C.M. 1:5 C.I. cover
with frame (Light duty) 455mm x 610mm intenal dimensions total weight of cover
with frame to be not less than 38Kg. (Wt. of cover 23 Kg.) and Wt. of frame 15Kg.
) (R.C.C. top slabe with 1:2:4 mix (1-cement :2- coarse sand :4-graded stone
aggregate 20mm size) foundation concrete 1:5:10 inside plaster 15mm thick with
cement mortar 1:3 finished smooth with a floating coat of neat cement on walls
and bed concrete etc. complete.(i) Inside dimensions 455mmx 610mm and
450mm deep for single pipe line.
Providing and fixing C.I. Manhole cover 0.60 M. x 0.45M. size having weight not
less than 35Kg.
59 Providing and fixing in position cowel went to pipes.(C) 100mm dia Each 15.00 500.17
(B) Providing sock pit of 5.00 Cu.M. Volume including excavating and filling
brickbats with dry masonry work at top for 45cm. height including covering the
60 top with stone including providing vatas in C.M. 1:3 with finishing curing etc. Each 1.00 3,423.04
complete as directed.
Supply, installation, testing and commissioning of ABC 6 KG fire Extinguisher
Supply, installation, resting and commissioning of CO2 4.5 kg Extinguisher with
Construction of Septic tank inside dimention of 5 m in length & 2.5 m in width &
1.5 m depth including excavating any type of soil as shown and mentioned in the
drawing,providing and laying 0.15 m thick plain cement concrete 1:3:6 ( 1 cement
: 3 coarse sand : 6 graded stone agg.) M.250 concrete grade slab at bottom with
brick masonary 0.230 to 0.450 m thick walls as shown and mentioned in the
drawing CM 1:5 ( 1 cement : 5 coarse sand ) & RCC Top and bottom slabs
cms thick in M.250 (1 cement : 1 coarse sand : 2 graded stone agg) including
63 reinforcement Fe 500D as per design and 20 mm thick cement plaster in CM 1:3 Each 1.00 2,61,454.70
using water proofing compound of approved quality with floating coat of neat
cement slurry inside, top and around tank below 20 cm on ground level, Also
provide Two nos CI Manhole frame and cover of size 60 cm x 45 cm & 75 mm dia.
PVC 6 kgf / Sq cm pressure air vent pipe in 7.00 length with cowl, C-I pipe
mm dia included bend spigot and socket soil, with P & F 12 no. cast iron step of
size 500mm x 150 mm x 22.5 mm with two coat anti corrosive paint etc complete
as per direction of Engineer in charge.
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey
comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long
complete as per standard design. With common burnt clay F.P.S. (non modular)
bricks of class designation
POINT WIRING FOR LIGHT / FAN WITH MODULAR PLATESWITCHES ANCHOR /
65 Providing and laying point wiring in concealed conduits for thefollowing points No. 5.00 520.00
using specified 1100V grade PVC insulated, FRLSmultistranded 3 x 1.5 sqmm
copper conductor
Same as above but for 5A socket controlled by one 5A switch on thesame
Same as above but for 5A socket controlled by one 5A switchindependently
67 mounted including providing wiring with 3 runs of 1.5sqmm pvc insulated No. 5.00 428.00
copper wire through PVC conduit
Same as above but for 5/15A socket controlled by 15A switchindependently
68 mounted including providing wiring with 2 runs of 2.5sqmm and 1 run of 1.5 No. 2.00 495.00
sqmm PVC insulated copper wire through PVCconduit.
Same as above but for AC point with 2 runs of 4 sqmm (P&N) and 1 runof
sqmm (earthing) PVC insulated, FRLS multistrand copper cable in25 mm dia PVC
conduit from MCBDB to 20 A power socket. The conduitshall be partly/fully
concealed in all types o
Supply, laying, and commissioning of wiring using following sizes ofPVC
insulated, FRLS, unsheathed, multistraned copper wire drawn inPVC conduits.
Rate to include supply of 16 GI fish wire, conduits &accessories, wiring,
terminations etc. complete
4 runs of 10 sq mm and 1 run of 6 sqmm copper wire in 40 mm dia PVCconduit
from panel to Distribution Boards
4 runs of 6 sqmm and 1 run of 4 sqmm copper wire in 32 mm dia PVCconduict
72 from panel to Distribution Boards.RMT170144 Rmt 10.00 590.00
Sweep :1400 mmColour :WhiteBearing type :Double ball
73 bearingDown Rod : Clear 300 mm longRegulator : Electronic type ANCHOR/MK m No. 10.00 3,200.00
akeAccessories : Screws, wall nuts etc.
145Supply, fixing and commissioning of 305 mm dia. Exhaust fansincluding bird
74 louvers, frame works and other civil works like chippingand making the surface No. 2.00 1,805.50
good etc.NOS1570146
LIGHT FIXTURES:
Supply, fixing and commissioning of following light fittings. Rate toinclude all
accessories, interconnection of wires from ceiling rose to thefittings and
fluorescent tube /GLS/PL lamps, copper choke etc
1 x 36 W tube light fitting with lamp Philips make cat no. TCS 19/136HPF or
76 1 x 18 W Foot light for drive way parking No 80.00 589.95
77 Angle Holder Anchor make including lamp 60W(Toilet) No 2.00 420.00
78 SITC of Car Charging point with MCB enclosure of 63 A No 5.00 32,000.00
2 x 36 W tube light fitting including lamp Phillps cat no TBS 50/236 HPFor
equivalent (for false ceiling area)
Supply and fixing of wall mounting type meter board made out of 16SWG CRCA
sheet steel and single iron with 3 nos 200A Fuse cutoutsN.L , 1 no. earth link,
no. neutral link and space for accommodating 1no. 3 ph, 4 wire KWH meter
complete with adequa
Supply, erection, testing and commissioning of floor mounting typecubical panel
board made out of 16 SWG CRCA sheet steel with 300 ATPN copper bus bars,
interconnections, earthing, powder coating andcomprising of the followings as
required.(TYPE I AS PER ENCLOSEDDRAWING):Incomer : 2 nos 125A TP switch
81 fuse unit with HRC fuses for DG andEB with interlocking 1 no.125A TP bus No 1.00 36,225.00
coupler / 2 nos. volt meter withvolt meter selector switch / 2 no. ammeter with CT
& Ammeter selectorswitch / 2 sets of Phase indicating lamp (RYB) / Outgoings :
nos 63Aand 6 nos 32A TP fuse switch unit with HRC fuse / 5KVAR capacitor :
Supply, erection, testing and commissioning of floor mounting typecubical panel
board made out of 16 SWG CRCA sheet steel with 200 ATPN copper bus bars,
interconnections, earthing, powder coating andcomprising of the following as
required. (TYPE II AS PER ENCLOSEDDRAWING):Incomer : 2 nos. 125A TP
82 switch fuse unit with HRC fuses for DG andEB / 125A 4 pole change over switch No 2.00 50,025.00
(on line) / 2 no volt meter with voltmeter selector switch / 2 no ammeter with CT &
ammeter selectorswitch / 2 sets of Phase indicating lamp (RYB) / Outgoings :
2nos 63Aand 3nos 32A TP fuse switch unit with HRC fuse/5 KVAR capacitor :
Same as above but with following details:- Incomer :2 nos 63A TPswitch fuse
unit with HRC fuses for DG and EB / 1no. 63A 4 polechange over switch (on line)
/ 2 no volt meter with volt meter selectorswitch / 2 no ammeter with CT &
ammeter selector swi
Supply, installation and commissioning of 63A TPN MCB DB Incomer :1 no 63 A
4 Pole MCB Outgoings : 18 nos, 10A/16A/20A SP MCBs
Supply, installation and commissioning of 32A TPN MCB DB Incomer :1 no 32 A
4 Pole MCB Outgoings : 12 nos, 10A/16A/20A SP MCBs
Supply and laying following size PVC insulated, sheathed, armouredcable of
87 3.5C X 35 sqmm AL cable MTR 90.00 540.00
88 4C X 16 sqmm AL cable MTR 146.00 290.00
89 4C X 6 sqmm AL cable MTR 345.00 210.00
90 4C X 2.5 sqmm AL cable MTR 636.00 195.00
91 3C X 2.5 sqmm AL cable MTR 520.00 150.00
92 3C X 2.5 sqmm copper cabl MTR 200.00 210.00
End termination of following cables with double compression NFLPgland and
93 crimping sockets No 8.00 230.00
3.5C X 35 sqmm AL cable
94 4C X 16 sqmm AL cable No 24.00 205.00
95 4C X 6 sqmm AL cable No 20.00 140.00
96 4C X 2.5 sqmm AL cable No 32.00 120.00
97 3C X 2.5 sqmm AL cable No 28.00 115.00
End termination of following cables with double compression NFLPgland and
98 crimping sockets No 24.00 152.00
3C X 2.5 sqmm copper cabl
Excavation in any type of soil including WBM / asphalt up to 600mmdepth and
99 300mm wide including supply and laying 150mm thick sandon top and bottom of Rmt 100.00 184.00
cable, supply and laying bricks laid flat on top,back filling trench etc. complete.
100 Junction box for yard light pole - No 55.00 811.90
Supply, Fabrication and Erection of 20 mtrs high galvanised Pole havinga base
plate of size 300x300x16 with 1000 mm long 40mm MS pipesuitable for mounting
1 no. fixture as per attached detail specificaton.Job also includes foundation for
P/f 7 mtr high hot galvanised octagonal pole, continously tapered (bolt fixing
type) in single
102 section made out of 3mm thick sheet suitable for bracket having top dia 70-75mm No 52.00 10,925.00
bottom dia 130-150 mm, base plate size 220X220X12 to 240X240X16 mm with
Installation of DG Set.
Supplying and erecting, commissioning and testing of Diesel Generating set
confirming to IS: 4722:1968 & BS:5514 having continuous rating, 3 phase,
volts, 50 cycles A.C. supply comprising of a totally enclosed air/water cooled
diesel engine with multi-cylinders developing suitable BHP not less than
following capacity at 1500 RPM with 10% overload for one hour in 24 hours with
standard accessories like fly wheel, lubricating oil cooler, "A" class governor,
heavy duty fuel wheel and lubricating oil filter, oil bath air filler, lubricating oil
pressure gauge, end exhaust manifold, standard set of tools with adjustable
spanners, screw drivers, cylinder head to cover, joint cylinder head to exhaust,
element lube oil filter, 12 / 24 volts electric starting equipment complete with
standard heavy duty battery, dynamo, cut-outs, ammeter, necessary wiring,
pressure gauge, starter etc and heavy duty Residential type exhaust silencer and
103 vertical hot air duct both indicator lamps duly wired with HRC fuses. No 1.00 5,00,000.00
The alternator & control panel shall be connected with provided suitable
capacity armoured cable and complete with Acoustic enclosure (canopy) made
out of 16 SWG CRCA Sheet, sound absorbing material Rockwool of 64 density &
100 mm thick conforming to IS:8183 / PU Foam of 40 Density - at least 40 mm.
The resin bonded rockwool covered from inside the canopy by perforated sheet
with 3/4 mm holes, sound level not more than 75 dB at a distance of 1 mtr, as per
PVCT norms. Erection, commissioning and satisfactory testing as per
requirement with first filling of fuel, oil, etc. with guarantee / Warrantee of
complete system for Two years. & with obtaining all necessary certificate from
Electrical Inspector. The Capacity and Ratings of DG sets are as below. (M)
Continuous rating of 125 KVA ,BHP not less than 154 BHP(M) Continuous rating
of 125 KVA ,BHP not less than 154 BHP
Supplying, Erecting, Testing & Commissioning the passenger Machine Room
Less lift having following main features: [1] GEAR LESS LIFT
DRIVE comprising of High Starting torque Lift duty 3 phase 440 V A. C.
Permanent magnetic synchronous motor of proper rating with high
efficiency shall be used. [2] Micro processor based / PLC, ACVVF, vector control
drive with encoder feedback closed loop system shall be used for lift car and
door operation which shall be full collective selective operation hall call demand
response, UP/DOWN hall stops, Main, Up/ Down Contactor with overload and
phase reversal relay and safety controls. [3] Car with M S platform with bracings
of adequate size and to sustain the impact load cabin + passenger with safety
factor of fire for steel and side panels of Stainless steel of sheet of grade
duty. Car ceiling will be S.S. finishes with aesthetic appearance with LED ceiling
lights. Car flooring shall be of anti skid PVC with choice of colour of engineer in
charge. Car doors shall be of stainless steel grade 304, hairline finish with centre
opening / telescopic automatic doors. Car panel will also be S.S. 304 finished
with emergency stop device, mechanical door safety device, facility of auto/
attended mode. All car panel buttons and all floor switches must be with brail
language as per lift act. [4] All landing doors shall be fully automatic centre
opening/ telescopic opening made of hairline finish steel grade of 304 with key
holes and infrared curtains with Unlocking facility from outside. [5] Appropriate
battery operated emergency light in the car along with alarm switch shall be
provided. [6] Digital scrolling indicator system for up - 1 down arrow along with
104 floor position indicator shall be provided inside the car and at all floors. No 2.00 25,85,000.00
[7] Full height infra red curtain with multiple criss / crossing light beams shall be
provided. [8] Automatic Rescue Device (ARD) shall be provided accordingly of
passenger capacity. [9] Audio visual indication in the lift car showing over
loading shall be provided such that doors kept open till excess load is removed.
[10] Spring buffers/PU Buffers shall be provided. [11] Car fan with automatic
sleep timer shall be provided. [12] Voice annunciater with suitable music shall be
provided in lift car. [13] Self diagnostics system for operational and safety
parameters shall be provided in control panel. [14] Mechanical over speed
governor, door key holes in the floor doors, fireman switch shall be provided.
[15] Lift machine hoisting arrangement in the lift machine room and monkey
ladder for lift pit should be provided by the lift agency, along with the other steel
structure works, foundations for the machine etc… [16] In the hoist way fascia
plate shall be provided without any extra cost, where ever required as / if
directed by engineer in charge. [17] Permanent wiring in lift machine room and
lift well with proper numbers of light points, with fixtures, exhaust fan and plug
points shall be provided by the agency. Power supply of 3 phase 440 V shall be
made available by department in lift machine room.
4 MP Fixed Lens, WDR, 50 Mtr IR Bullet Camera
CP-UNC-TC41L5C-VMD-LQ
106 4 MP Fixed Lens, WDR, 50 Mtr IR Bullet Camera No 3.00 10462.50
107 8PORT POE+ 2 SFP PORT SWITCH CP-ANW-GPU8G2F2-N12 No 5.00 8525.00
108 16PORT POE+ 2 SFP PORT SWITCH CP-ANW-GPU16G2F2-N12 No 1.00 19375.00
32 Chnl 8 SATA ,RAID TECHNOLOGY ENABLED NVR,
CP-UNR-4K532R8-FI
110 8 TB Surveillance HDD No 4.00 40610.00
111 RF Set for Lifts to Avoid Cabling Inside the Lift Cabin No 2.00 12787.50
112 RJ-45 CONNECTOR No 80.00 15.50
113 IP 65 Rated weather proof BACK BOX No 32.00 139.50
114 12 U 600 X 600 POWDER COATED METAL RACK No 1.00 16275.00
115 OUT Door Weather Proof Box for switch No 5.00 4960.00
116 SFP Module No 12.00 1860.00
117 Fiber Patch Cord No 12.00 1937.50
118 12 PORT LOADED LIU No 6.00 5425.00
119 Splicing for Fiber Core Rmt 48.00 519.25
Installation of Camera, NVR, RACK, Switches and One year support for
Hardware issues only
Fiber Cable laying Including Cable, Conduit & Accessories & Labor.
CORE , GEL FILLED, SINGAL MODE, Armored FIBER OPTIC CABLE
UTP Cable Laying Including CAT - 6 UTP CABLE, Conduit Pipe &
Accessories & Labor
providing and fixing 6 mtr Boom Barrier with remote control operation ,with
include feature manual and auto closed , Smart inbuilt Red & Green LED Light on
Boom Barrier , Safety Photocell all are inclusive in rate ,2 year warranty also
include boom barrier Base R.C.C Foundation as per drawing The rate also
includes for all necessary items Boom Barrier set with 2 Remote controll,
required to complete the job as per Location and consultant's instructions
I/We am/are willing to carry out the work at …………………% above/below percent ( should be written in figures ……………………………………………………) of the
Estimate amount: Estimate amount:
Put to tender Rs. Put to tender Rs.
Note: 1 All work shall be carried out as per Public Works Department Handbook and other specifications of Division or as directed.
AW]\ H SFD AF\WSFD lJEFUGL 5]l:TSF VG[ l0lJhGGL ALHL BF; lJUT D]HA VYJF ;}RGF 5|DF6[ SZL VF5JFG]\ ZC[X[P
Note- 2 All the columns is Schedule should be filled in ink and the total of the entries in the last column should be struck by the contractor under his signature.
VG];}lRDF\ AWF BFGFGL lJUTM ;CLYL EZJL VG[ K[<,F BFGFGL GM\WMGM ;ZJF/M SZL SMg8=FS8Z[ 5MTFGL ;CL SZJL
Note- 3 Rates quoted include clearance of site (prior commencement of work and at its close ) in all respects and hold good for work under all conditions, site,
GM\W 8F\S[,F NZDF\4 :Y/GL s SFDGF VFZ\E[ VG[ 5}~ YFI T[ JBT[ f NZ[S ZLT[ ;FO;}OL SZJFGM ;DFJ[X YFI K[P VG[ T[ NZ TDFD 5lZl:YlT 4 :Y/4 E[H4
v# CJFDFG JU[Z[ C[9/ SFD DF8[ VD,DF\ ZC[X[P
Note- 4 To be continued on additional sheets, if found necessary
GM\Wv$ H~Z H6FI JWFZFGF SFU/M HM0L RF,]\ ZFBJ]\P
Signature of Contractor with Seal
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
02 Uparkot Lift Section.pdf
01. NIT.pdf
03 Uparkot Lift Plan.pdf
04. SBD.pdf
07. CIVIL SPECIFICATION.pdf
08. ELECTRICAL SPECIFICATION.pdf
MOU-1.pdf
MOU-2.pdf
Schedule-B.pdf
Security Cabin Detail.pdf
Site Plan.pdf
Ticket Window Detail.pdf
Download all tender documents and submit your bid