Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.7 LAccepted-AOC HIJALPUKUR M M DUTTA ROAD HABRA 24 PARAGANS N | HABRA | 24 PARAGANS N | WEST BENGAL | L1 | Accepted-AOC L1 | |
| 2 | L2₹12.8 L+₹9,624 (0.76%)Rejected-Finance 90 1 287 1 ADARSHA PARA PURBA BIDHYHARPUR SHYAMNAGAR 24 PGS N PIN 743127 | SHYAMNAGAR | NORTH 24 PARGANAS | WEST BENGAL | 743127 | L2 | Rejected-Finance L2 | |
| 3 | L3₹13.0 L+₹28,816 (2.27%)Rejected-Finance | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹36,000
Closing Date
7 Dec 2024, 3:00 pmClosed
EXECUTIVE ENGINEER BIDHANNAGAR ELECTRICAL DIVN
ROOM NO -108 PURTA BHAWAN SALT LAKE KOL 91
Dismantling and refixing of ceiling fans and light fittings in connection with the false ceiling repairing works at academic building and library building at Aliah University New Town campus
2024_WBPWD_770227_1
WBPWD/EE/BED/e-NIQ-44/2024-25
Open Tender
ELECTRICAL WORKS M/R
Item Rate
14 days
Aliah University New Town campus
Please refer Tender documents.
5 documents required · 5 mandatory
₹36,000
19 Dec 2024
22 Nov 2024
9 Dec 2024
23 Nov 2024
7 Dec 2024
23 Nov 2024
Amount
Dismantling of existing damaged electrical wiring, switch board, fittings fixtures etc. due to false ceiling repairing and wall panneling work of civil wing as per direction of EIC.
Lowering and refixing only after washing and cleaning of ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. making necessary disconnection and connection as required as per direction of EIC.
Dismantling of existing single/twin fluorescent light fitting as and when required and store in a safe place as per direction of EIC and Re-fixing of single/twin fluorescent light fitting suspended 25 cm below the ceiling with existing 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with existing “L” type MS clamp whose one side'fixed on ceiling with suitable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts as per GS.
Lowering and refixing only wall mounted fans complete with necessary fittings on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length
Dismantling of existing recessed type fittings from ceiling/wall as applicable as and when required and store in a safe place as per direction of EIC and Re-Fixing only 2ftX2ft/round shape recessed mounted LED fitting complete with all accessories on false ceiling on existing holes and necessary connections etc. as required
Taken down & refixing the 56"/48" celling fans and exhaust fan & 16" wall Bracket Fan and exhaust fan from the celling/Wall with own tools & tackels after repairing.
Oiling cleaning greasing & overhauling including opening the fans part by part & refixing the same after varnishing.
Supply & changing suitable size new bush bearing.(Make approved by E.I.C)
Supply & Fixing 3" nut,bolt,washer ,screw etc. if required.
Supply & changing 2x1/1.40 pvc insulated &sheeted appropiate wires including making necessary connection for Ceilling fan & Exhaust Fan.(Make approved by E.I.C)
Opening testing the 56"/48"celling are cutting the burnt out coils from the starter after cleaning the stator coils. Rewinding the starter coils with supper enameled copper wires of approved guage including backing varnishing and testing complete.
S/Changing new shaft of ceilling fan.
S &f condenser clamp of ceilling fan.
Supply & changing shaft pipe & washer.
S & changing suitable size new ball bearing(Make approved by EIC)
S&F split pin as required size incl. drilling holes if required.
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR'PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe (for horizontal & vertical run in wall and celing portion through prelaid polythen pipe) complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish. 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC. (a) Average run 10 mtr.
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish. (a) On Board
Supplying & Fixing of 2 Row 12 Module GI Modular Switch Board complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works.
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required. (a) 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
(b) 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
Supply and Laying of 4 core 50 sqmm cable on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting. (Make-Gloster/KEI/RR) (Make: Havells/ Polycab/ Gloster/ RR Kabel/ KEI/MESCAB)
Supply and Laying of 4 core 35 sqmm cable on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting. (Make-(Make: Havells/ Polycab/ Gloster/ RR Kabel/ KEI/MESCAB))
Supplying and fixing of 4 core upto 50 sqmm compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables.
Supplying and fixing of 4 core upto 35 sqmm compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables.
Finishing the end of 4 core upto 50 sqmm XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials.
Finishing the end of 4 core upto 35 sqmm XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials.
Supply & Fixing of 48" ceiling fan with stranded safety wire complete with blades, canopy, fork, rubber, bush, etc incl. S&F of 1.5 ft down rod [14SWG) with connecting wire for down rod & making necessary connection as required by 3x22/0.3 mm [1.5sqmm) 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) making earthing attachment, painting the down rod and mending good the damages to original finish [Make- Crompton, Cat No:-HS Plus-1200mm/Orient/Havells of equivalent make]
Supply & Fixing of 450mm sweep full metal body wall mounted fan with stranded safety wire complete with blades, canopy, fork, rubber, bush, etc on wall by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length as per direction of EIC. [Make- EPC/ Crompton 450mm ACVORTEX18WM of equivalent make]
Supply & fixing of 4' long 28 watt T-5 fluorescent tube light on existing fittings having 5800K- 6000K, luminous efficiency not less than 100 Lm/Watt in place of damaged item incl. all accessories as required as per direction of EIC. (Make: Wipro/Philips- Signify/ Crompton)
Supply & fixing of single electronic ballast for 4' long 28 watt T-5 fluorescent tube light on existing fittings in place of damaged item incl. all accessories as required as per direction of EIC. (Make: Wipro/Philips- Signify/ Crompton)
Supply & fixing of twin electronic ballast for 4' long 28 watt T-5 fluorescent tube light on existing fittings in place of damaged item incl. all accessories as required as per direction of EIC. (Make: Wipro/Philips- Signify/ Crompton)
Supply & fixing of 36watt PL-L light on existing fittings having 5800K- 6000K,, luminous efficiency not less than 100 Lm/Watt in place of damaged item incl. all accessories as required as per direction of EIC. (Make: Wipro/Philips- Signify/ Crompton)
Supply & fixing of 18 watt LED PL-L light on existing fittings having 5800K- 6000K,, luminous efficiency not less than 100 Lm/Watt in place of damaged item incl. all accessories as required as per direction of EIC. (Make: Wipro/Philips- Signify/ Crompton)
Supply & fixing of single electronic ballast for 36 watt PL-L light on existing fittings in place of damaged item incl. all accessories as required as per direction of EIC. (Make: Wipro/Philips- Signify/ Crompton)
Supply & fixing of twin electronic ballast for 36 watt PL-L light on existing fittings in place of damaged item incl. all accessories as required as per direction of EIC. (Make: Wipro/Philips- Signify/ Crompton)
Supply & fixing of 2 x 20 watt LED decorative tube light Fitting on surface mounted having 5800K- 6000K, LED, luminous efficiency not less than 100 Lm/Watt Driver wattage should be greater than or eual to the rated fittings wattage incl. all accessories as required as per direction of EIC. (Make: Wipro/Philips- Signify/ Crompton)
Supply & fixing of 18 watt LED PL L light Fitting on existing fittings having 5800K- 6000K, LED, luminous efficiency not less than 100 Lm/Watt Driver wattage should be greater than or eual to the rated fittings wattage incl. all accessories as required as per direction of EIC. (Make: Wipro/Philips- Signify- Essential LED PL L 4P-865 / Crompton)
Supply & fixing of 24 watt, 1' x 1' surface mounted Square LED downligbter Fitting having 2400 Lm LED, having 5800K- 6000K, luminous efficienry not less than 100 Lumen/watt Driver wattage should be greater than or eual to the rated fittings wattage incl. all accessories as required as per direction of ElC [Make: Wipro/Philips- Signify-Rimless Full glow / Crompton).
Supply & fixing of 20 watt slimline ultra LED tube light set on surface/ existing fittings having 5800K- 6000K, LED, luminous efficiency not less than 100 Lm/Watt Driver wattage should be greater than or eual to the rated fittings wattage incl. all accessories as required as per direction of EIC. (Make: Wipro/Philips- Signify- Essential LED PL L 4P-865 / Crompton)
Supply & fixing of 9 watt LED bulb on existing light fittings at stair case light Fitting incl. all accessories as required as per direction of EIC. (Make: Wipro/Philips- Signify/ Crompton)
Supplying & Fixing pendent light fitting complete with holder incl. S&F 24/0.20 twin twisted tinned copper conductor flexible cord and suspended below ceiling/beam upto 45 cm incl. all accessories as required as per direction of EIC. (Make: Wipro/Philips- Signify/ Crompton)
Supply & fixing of 2' long 12 watt T-5 fluorescent tube light on existing fittings having 5800K- 6000K,, luminous efficiency not less than 100 Lm/Watt in place of damaged item incl. all accessories as required as per direction of EIC. (Make: Wipro/Philips- Signify/ Crompton)
Supply & fixing of twin electrinic ballast for 2' long 12 watt T-5 fluorescent tube light on existing fittings in place of damaged item incl. all accessories as required as per direction of EIC. (Make: Wipro/Philips- Signify/ Crompton)
Supply & fixing of 4ft 18 watt 2100 Lumen o/p, colour temperature 5500 K twin LED light fitting with tube Iight on the wall/celling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with "L" type MS clamp whose one side fixed on ceiling with sutable size 4 nos fastener and other side connected with the fitting with suitable size of bolt and nuts incl. S&F EI conduit, "L" type [125mmx125mm) 6mm thick and 25 mm width MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc, by 3x22/0.3 mm (1.5sqmm) 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of 1.10 mt length, (Make- Philips, Cat No. TMC 502P 2xT LED 22W P3242,LED Cat No-MAS LED tube 1200mm 18w865 T8 I, similar to Crompton/Wipro- brand approved by EIC.
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Note:- Rate should be quoted inclusive of all taxes and duties including GST.
MANTHU ELECTRICALS (BID ID -5806867)
T. K. ENTERPRISE (BID ID -5807153)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .