Loading…
Loading…
Tender ID
Tender Value
₹2.0 Cr
EMD Value
₹7.0 L
Closing Date
6 Feb 2026, 6:00 pmClosed
MANAGING DIRECTOR,GRIMCO GANDHINAGAR
TENDER FOR CIVIL/ INTERIOR/ ELECTRICAL/HVAC WORK FOR GUJARAT INFORMATICS LIMITED, GANDHINAGAR.
266469
13/2025-26
Open
Miscellaneous Works
Works
Gandhinagar
3 documents required · 3 mandatory
₹17,700
GANDHINAGAR
₹7.0 L
17 Jan 2026
17 Jan 2026
17 Jan 2026
6 Feb 2026
17 Jan 2026
Point wiring for Light / Bell with 2-1.5 sq.mm AND earth wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr length , in below type of pipe erected with 6A Modular type switch / bell push AND accessories and earth continuity of following type, erected on PVC / Metallic/Wooden box, single mounting base frame covered with textured/metallic/white front plate modules erected on / in wall / ceiling as per pipe erected, with necessary Lamp holder/ceiling rose / H.D.Connector as directed. (f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete
Providing AND laying 1st class burnt brick masonary for super structure using bricks having crushing strength not less than 35kg/sqcm. AND set in c.m. (1:6) incl. racking AND paint joints incl. scaffolding, watering, curing etc. comp. as directed.
PLASTER WORK : Providing 15mm thk. Cement plaster in single coat on Internal Walls for interior plastering of following finished even and smooth in Cement Mortar 1:3 (1-Cement : 3-Sand) incl. finishing with a floating coat of neat cement slurry.
Supplying AND fixing heavy duty 1200 X 600 mm Vitrified tiles With Epoxy Grout of 8 to 9 mm th. of Approved Brand in flooring as per approved pattern ,AND design laid over neat cement slurry AND cement mortar in (1:6) bedding 20 mm th. average AND joint with colour cement slurry incl. special cornices, corners or angles, tiles etc. incl.Existing Removing Flooring cost and fixing materials, labour, tools, plants, equipmens incl. all lead AND lift comp. as directed by Architect /EIC .(Tiles as per Existing tiles Matching)
Supplying AND fixing heavy duty 1200 X 600 mm Vitrified tiles of 8 to 9 mm th. of Approved Brand in Skirting With Epoxy Grout as per approved pattern ,Match Shade with Existing Flooring AND design laid over neat cement slurry AND cement mortar in (1:6) bedding 20 mm th. average AND joint with colour cement slurry incl. special cornices, corners or angles, tiles etc. incl.Existing Removing Skirting cost of fixing materials, labour, tools, plants, equipmens incl. all lead AND lift comp. as directed by Architect /EIC .(Tiles as per Existing tiles Matching)
Providing ,laying AND Fixing 50 mm thick Expansion Joint by hydro cell Semi rigid UV resistance with High perfomanace laminated closed cell polythene foam joint fillerr in sheet foam as per directed. .Rate Shall Be Consider All Floor AND Work Shall be Execute as per Architect Grimco Manager Instruction.
Providing and filling the expansion joint by polymer confirm to BS 4254-1983 as per required shade and manufactured specifi cation by making groove of 25 mm x 50 mm lather by cutting or by repairing groove and removing mortar drop or any other foreign materials including applying primer and filling required size (oversize of joint PU foam etc. complete as per directed. .Rate Shall Be Consider All Floor AND Work Shall be Execute as per Architect Grimco Manager Instruction.
Maintenance of existing aluminum windows with Wooden frame (to be removed AND refixed) with new ribbons, clear white gaskets, rollers, handles etc complete with applying silicon from outside to restrict the seepage of rain water. Aluminum sections shall be powder coating of approved shade and colour after sanding surface as per instruction and Repair the Existing Wooden Frame with Paint as per Architect and EIC Instruction.
Duct Door finish with cement sheet AND frame : Providing and fixing in position 35mm thick solid core wooden single leaf flush doors of approved make having fire retardant ply facing on both sides and finished with 12 mm thick cement sheet as approved , shutter fixed with floor and above pivot of approved make , pivot cover plate, lock AND handle etc fixtures of approved make list with all necessary fittings etc. aluminum frame 25x30 Complete as per detailed drawings and specifications , Grimco Manager /Architect. Instruction. .Rate Shall Be Consider All Floor AND Work Shall be Execute as per Architect Grimco Manager Instruction.
Floor Protection Sheet Providing and applying covering on flooring for floor protection with Heavy duty bubble sheet on newly placed flooring. The rate should include the cleaning of plastic on completion before handing over completed site.
P.O.P Punning on wall : Providing and applying POP Punning on walls and columns (average 12mm to 25mm the). The rate shall include scrapping, leveling and preparing the surface. The rate shall be inclusive of all types of grooves above the skirting, around the window and door frames. completed as directed by Project manager / Architect.
Providing fixing PLAIN GYPBOARD FALSE CEILING Providing and fixing suspended false ceiling consisting of 12.5mm thick Gypsum board suspended on GI framework. GI framework to consist of GI perimeter channels 0.55mm thick 20mm x 30mm along perimeter of false ceiling of ceiling, screw fixed to wall/partition with nylon sleeves and screws 600mm c/c. Suspending GI intermediate channels of size 0.9mm thick 45mm x 15mm from the soffit at max dist 1220mm c/c with ceiling angle 0.55mm thick 25mm x 10mm fixed to soffit using proprietary supplied GI cleats and steel expansion fasteners.Boards to be finished with proprietary supplied jointing tape and jointing compound and sand papered to achieve a smooth and seamless finish. and 2 coats of primer suitable for Gypsum board applied ready to receive finish.Rate quoted to include vertical all cut-outs required for light fixtures, smoke detectors and other services cut-outs complete as directed by Architect.Rate quoted to include cost of providing support framework formed of perimeter channels for fixing light fixtures, AC grills/diffusers etc. Also to provide concealed perimeter channel support as required to support modular grid ceiling sections at junction between gypboard false ceiling and modular grid tile ceiling.
Gypsum ceiling Patta ( 50mm ht to 250mm ht )- as per above specification. ( Item No : 4.1 )
Grid ceiling : Providing and fixing 2' x 2' modular grid ceiling : providing and fixing modular ceiling systems with mineral fiber board ceiling tiles as per following specifications, rate to include all fastening accessories with approved finishes. Fire retardant tiles of size 600mm x 600mm x 20mm thick of approved colour and type with acoustical property of 0.0nrc, with beveled tegular edge. ( measured on horizontal plane only.) Horizontal plane measurements are to be inclusive of all vertical drops, edge mouldings, fascia's, etc. Rate quoted to include all cut-outs required for light fixtures, smoke detectors and other services cut-outs complete as directed by Architect. Rate quoted to include cost of providing support framework formed of perimeter channels for fixing light fixtures, AC grills/diffusers etc. Also to provide concealed perimeter channel support as required to support modular grid ceiling sections at junction between gypboard false ceiling and modular grid tile ceiling.
Baffle Ceiling : baffle ceiling this shall consist of 'U' shaped 0.5mm thick GAL section , The size of the 'U' sections shall be 25x100 mm with baffle to baffle 100 mm and centre to centre 175 mm (which can be modified as per architect/designers requirement). available in length of 3900mm.which can be modified as per the architect design .The baffles shall be fixed to each other using framework of size 25mmx15mm made using 0.8mm thick GI sheet which is folded and bent to desired profile finished with powder coating. These mild steel framework/sections shall be inserted between two members and fixed using self interlocking system. The mild steel framework in turn are fixed on to he true ceiling above using a suitable suspension system consisting of nuts, Washers, 6mm GI rod and anchor fasteners. This ceiling facilitates easy maintenance. Rate to includes necessary supports as per manufacturer specification. The ceiling and the accessories are provided with powder coated thickness of 100-120 microns.
Wooden Laminate Design finish Rafter Partition ( 100mm x 50mm thick.) Providing and fixing wooden Rafter type partition using 100mm x 50mm made out of solid plywood covered with 1mm thick approved shade of laminate finish at spacing not exceeding 150mm C/C horizontal including supports at floor level and slab/ ceiling level , using 50mm X 50mm X 1.5mm thick "L" angle support cleats fixed with 12mm galvanized metal bolts/screws. Rafter work to be secured to floor, structural support and nearest structural member using galvanized metal screws, including groove pattern as per design. Necessary vertical wooden/ply/aluminium members to be extended up to the slab level above false ceiling for support, No extra cost to be given for support above false ceiling. Any provision of services is included in the rates. Only visible area below false ceiling to be measured in one side front elevation in sqm for mode of payment. The rafter partition shall be executed as per detail architectural drawing. Rate shall include necessary approved hardware items including all materials and labour etc. complete as per detail instruction of engineer-in charge and consultant.
CHIPPING CONCRETE WORK :Chipping of unsound weak concrete material from slab, beam, column and around the reinforcement incl. plaster etc. with manual chiseling with standard power driven percussion type of pneumatic chisel of standard make as directed by Eng.. In Charge incl. tapering all edges and making square shoulders of cavities etc. comp. and disposal of debris outside the premises incl. cleaning of exposed reinforcement using approved alkaline chemical rust remover (doctor fix it rust remover or its equivalent chemical comp. as per manufacturers specification) (Area of RCC surface is to be measured for payment) etc. incl applying 10 to 15 mm avg. thick plaster in C.M. (1:3) incl. curing, scaffolding, curing, Existing Removing AND Scrape Plaster etc. comp. as directed by Grimco Manager /Architect.
applying primer coat of the paint, Putty shall be applying walls and ceiling for making even surface up to finish level.Providing and applying even coats of acrylic emulsion paint / on walls and ceiling up to final finish. Shade and texture of the paint shall be as approved by Architect or EIC. Application of paint shall be with brush and last coat of paint shall be applied with a standard company roller all as approved by architect or All rates are inclusive cost of paint , scrapping the surface, putty, primer, brush, roller, scaffolding cleaning charges etc. complete.
Providing and applying synthetic enamel paint of approved brand to previously painted steel work with one coat of approved quality and of required shade, including cleaning and scrapping the surface with sand paper etc. complete as directed.
Full ht Partition 75mm thick with aluminium framework with 12mm thk mdf exterior grade / 12mm thick hdf finish on both sides ( 75mm thick.) Providing and fixing partition frame work using of 50mm x 38mm x 1.5 mm ( as per IS Standards of Jindal or equivalent make ) thick extruded aluminium box section framework at spacing not exceeding 600mm C/C both ways ( horizontal and vertical ) framework formed using 50mm x 38mm x 1.5mm thick extruded aluminium box section connected using 50mm X 50mm X 1.5mm thick "L" angle support cleats fixed with 12mm galvanized metal screws. partition framework to be secured to floor, structural support and nearest structural member using galvanized metal screws and wooden dowels, 12mm thick HDF Sheet ( IS:303 ) grade on both sides, finished approved shade, and groove pattern as per design. necessary vertical aluminium framework members to be extended up to the slab level above false ceiling for support with all electrical, networking boxes which shall be installed on 25mm x 25mm x 1.2mm thick extruded aluminium "L" angle screwed onto partition framework. required holes/face plate for conduit pipes of electrical / networking cables and other services provision is included in the rates. Only visible area below false ceiling to be measured for mode of payment. No extra cost to be given for support above false ceiling. all complete as per architectural drawing. Rate shall include necessary approved hardware items including all materials and labour etc. complete as per detail instruction of engineer-in charge and consultant.
Low ht Partition Both side Laminate Finish Partition ( 75mm thick.) Providing and fixing partition frame work using of 50mm x 38mm x 1.5 mm ( as per IS Standards of Jindal or equivalent make ) thick extruded aluminium box section framework at spacing not exceeding 600mm C/C both ways ( horizontal and vertical ) framework formed using 50mm x 38mm x 1.5mm thick extruded aluminium box section connected using 50mm X 50mm X 1.5mm thick "L" angle support cleats fixed with 12mm galvanized metal screws. partition framework to be secured to floor, structural support and nearest structural member using galvanized metal screws and wooden dowels, 12mm thick commercial plywood ( IS:303 ) grade on both sides, finished with 1.0mm thick laminate of approved shade, 75mm x 18mm ghana teak wooden patta on low ht partition top / partition side as per site required and groove pattern as per design. with all electrical, networking boxes which shall be installed on 25mm x 25mm x 1.2mm thick extruded aluminium "L" angle screwed onto partition framework. required holes/face plate for conduit pipes of electrical / networking cables and other services provision is included in the rates. In case wood is used at any place due to constraint, it must be finished with duco color or polish matching with laminate. all complete as per architectural drawing. Rate shall include necessary approved hardware items including all materials and labour etc. complete as per detail instruction of engineer-in charge and consultant.
Providing and fixing full height glass partition : made out of glazed partition with Slim line Partitions systems of 45 x 25 mm thick section on all four sides with 10mm thick clear tempered glass, to be butt jointed with 2 to 3 mm edge chamfer AND edge polishing all around. Distance between two butt jointed glass panels not to exceed 4mm. Edges and grooves between glass panels to be filled with as Vertical "I" Section, between Glass to glass joint from FFL up to FCL Level neatly applied all complete as per architectural drawing. Rate shall include necessary approved hardware items including all materials and labour etc. complete as per detail instruction of engineer-in charge and consultant.45 x 25 mm thick section
SOFT BOARD/ PIN-UP BOARD Providing and fixing 12 mm thk. Pinup board comprising of 12 mm thk. back Ply fixed on wall with 15mm thk pinup board (Soft board) covered with fabric of approved co. (Basic rateEQUAL TORs.150 per running meter.) with teak wood beading 1" x 1" all around finished melamine polish.
Pelmet for Roller Blinds- 1.0mm thick Laminate Finish Providing and fixing Pelmet for blinds, made out of 18mm thick ply, exposed edges of the pelmet shall be finished in approved 1.0mm thick Laminate, wooden beading patti on open edge , The pelmet shall be in reversed "U" shape and shall be 200mm wide and up to the nearest Horizontal Mullion. The rate quoted shall be including fixing the pelmet with wooden/ aluminium/ GI support 1200mm c/c anchor bolted to the structural ceiling etc., complete as per detail drawings.
Door frame - Providing and fixing Door frame made out of 1st quality Ghana teak Wooden frame finished with architrave patti on wooden frame with melamine polish/ Colour duco paint Finish fitted with hold fast/ fasteners as approved by architect. All door frames shall be treated with Borer/Anti termite treatment all complete as per architectural drawing. Rate shall include necessary approved hardware items including all materials and labour etc. complete as per detail instruction of engineer-in charge and consultant. (Door Frame Size : 75 mm x 50 mm)
Providing and fixing Roller Blind fixed on window level on wooden batten and curtain lift with cotton thin rope, design and colour as per instruction by engineer – in – Charge with necessary hardware fitting, material and labour etc. complete as per detail drawing and instruction of engineer-in charge and consultant.
WOODEN NAME PLATE AS PER CLIENT INSTRUCTION
Letters for Gujarat Informatics Limited Institute Transformation AND Address Main Entry Side Wall 7" Height Font + 18" X 18" LOGO (SS FINISH)
supplying AND fixing 3m sparkel film on glass with manufacturer specification, as per the detailed technical specifications, drawings and as per the instructions of Engineer- in- charge.
Providing and Fixing Doormat (6' X 2') made up of synthetic material as per the approval from the Architect / EIC.
Providing, supplying Water Dispenser as per approved make. As per instruction at site approved by Architect of Engineer in charge.
Work station in Staff room (Size:- 1350L X 600D X 750H ) TABLE TOP : 25mm thick PLPB board with 2mm thick PVCedge banding finish with as per approved laminate color. LEGS:- 50mm x 50mm CRC square pipe with powder coated finish as per approved shade. BEAM:- 40mm x 40mm CRC square pipe with powder coated finish as per approved shade provided with die casted brackets to support top. SCREEN:- Sandwich fabric Screen supported on Die Casted brackets, Size of Screen:- 900x400x18 mm thk. Wire Manger on table top WIRE CARRIER :- Powder coated wire carrier to be provided for arranging wires for electricity AND data . WIRE RISER:- Powder coated wire riser to be provided for raising wires form floor.
Pedestrian Unit (3 drawer)
Conference Table 7600mm x 1800mm x 750mm Ht Providing and fixing Conference table with 48mm thick table top made out of 18mm + 18mm thick Calibrated block board and finished in 6mm thk solid acrylic surface (corian) top and same structure and corian finish to be taken on end verticle surface in continuation with the top. Intenral C shape vertical surface/Support for table made of 25mm thk claribated block board + 18mm thk calibrated plywood + one side 4.0mm thick natural Veneer + other side 1mm thk laminate finish, total 35mm thick. The middle service box made out of 18mm thk calibrated plywood finished with 1mm thick laminate on both sides of approved shade and beading patti to be finish in monocoat polish. The table internal raceway box and supported box units shall have intermediate support/shelves made in 18mm thick calibrated plywood 303 grade and internal surface only raceway box and table middle raceway boxing out side 1.0mm thick laminate finish with matching wood lipping and top and visible side at both ends finish with 4.0mm natural veneer finish. Provision of electrical wiring service openable shutter as per requirement made in 18mm thick calibrated block board with one side 4mm thk veneer finish AND other Side 1.0mm thk laminate finish. table in required holes/popup box cutout/recessed electrical power track cutout/ face plate for conduit pipes of electrical / networking cables and other services provision is included in the rates. The Table shall have matching wood edge . All exposed wooden surfaces mono coat polished. all complete as per architectural drawing. Rate shall include necessary approved hardware items including all materials and labour etc. Cost to include Borer/Anti termite treatment for wood/plywood completed as directed by Project manager / Architect.
Low ht storage units - Providing and fixing 450mm deep Low height storage unit made of 19mm thick plywood and finished with 1.0mm thick laminate externally and internally. Openable shutter made of 19mm thick plywood to be provided finished with 1.0mm thick laminate internally and externally. Intermediate shelves made of 19mm thick plywood to provided (as per size of box file/office file) finished with 1 mm laminate. The exposed edges of the shelves should have post form edges All complete including necessary hardware, heavy duty hinges, handles, locks etc.
Supplying and fixing Board/Exterior Elevation ANDSinages with 3mm thick exterior grade ACP with Vinyl letters [Non Reflective] including propore M.S.Structure of 45x45mm Hollow square box section of 20guage with one coat of Anticorrossive paint and two coat of oil paint with required anchoring fastners etc.complete as per directed. Rate Shall Be Consider All Floor AND Work Shall be Execute as per Architect Grimco Manager Instruction.
Providing and Supplying Plantation with Fibre glass pots / SS pots ( Plantation Basic Cost Rs 4000/- ) completed as per drawing and details instruction of engineer-in charge and consultant, as per the sample approved by the Architect.
Carpet Flooring _Bike path collection _office aera Scope - Work shall include the furnishing of all materials, equipment and labour to install the complete Carpet system with the manufacturer's approved adhesive. It is the Vendor's / supplier's responsibility to ensure that materials delivered on site is on the decided date by the project team AND it is safeguarded from the time of his purchase until he hands over the finished flooring. It is desirable to store materials in a pred-decided flat, clean and dry surface.Carpet floor shall be installed by a thoroughly experienced vendor and the type of installation shall be as per manufacturer's specifications. The Vendor shall inspect the premises prior to commencement of work and verify that the building is ready for installation.Carpets to be laid as per the pattern indicated on drawing. All wastages, octroi ,freight AND handling to be accounted for and no additional amount shall be paid for the same. Rate to be inclusive of covering of carpet with 50 micron double plastic cover AND sealing of joints with tape. Any pencil marks etc., shall be removed using ordinary pencil eraser. All damaged portions to be replaced free of cost.Providing and laying of Carpet Tile over the specified area with following specification. The floor which receives the carpet to be thoroughly cleaned as per manufacturer's specification. The carpet is to be laid over a bed of manufacturer's approved adhesive spread evenly over the entire floor. The rate shall include cutting, trimming, fixing and clearing away of residual material to a location as directed. The rate shall also include supplying and laying of a protective layer of PVC or HDPE sheet of 50 microns thickness Double Layer, held together with scotch tape. The laid carpet to be vacuumed after the removal of protective cover/on commissioning. If after the protective layer is removed and stains observed in the carpet because of in adequate protection, the same shall be shampooed and made good to the satisfaction of the project managers. The measurements of carpet will be the actual laid area.
Wooden Flooring Supplying, fitting and fixing 8 mm thick Laminated wooden Flooring ( AC-4 Grade ) Work conforming to EN13329:2006 with plank size not Iess than 1200mmX 190 mm (with unilin/tongue-groove locking arrangement) having 0.2mm thick top abrasive layer over a decorative layer followed by a High-density fibreboard (HDF) having density > 940 kg/m3 substrate core over a resin saturated backing layer and installing through unilin or tongue- groove system (having locking strength not less than 1000 kg/m) over a 2 mm thick underlayer polyurethane foam on polythene sheet 250 micron, over a smooth, flat, hard subfloor free from moisture (< 8PERCENTAGE ), grease etc. complete in all respect with requisite accessories like end profile, transition profile, reducer 'T' profile etc. wherever required and preparation of existing flooring surface POP levelling base including as per site location with all other incidental works as per direction AND satisfaction of Engineer in charge. Cost of Laminate Floor Accessories only ( Skirting, End edge, Tmoulding, Reducer ) shall have to be added separately, wherever required. The rate shall include labour, material, maintenance up to handover, cleaning etc. complete. The surface shall be scratch free at the time of handover. All works shall be done as per architect's specifications and instructions.
Providing AND Fixing 2 mm thick PVC Vinyl Flooring AND Skirting as per Approved sample. Cost Shall Be Including Wastage, Fixing Charge , Transportation with all Lead AND Lift . Two Plank Shall Be Joint Proper Line Level with Butt Joint with Proper Finishing as per instruction of Architect AND Grimco Manager. .Rate Shall Be Consider All Floor AND Work Shall be Execute as per Architect Grimco Manager Instruction.
MB chair Providing and placing Medium back chair with Mesh back , KneeTilt Mechanism, Fixed Silver Epoxy Armrest , Gaslift for Seat height adjustment , Standard 5-prong Nylon Base, With Fabric Including necessary hardware completed as per approved design, make and Architect's instructions. ( Basic rate Rs 11000/- per no)
HB chair Providing and placing High back chair with Mesh back , KneeTilt Mechanism, Fixed Silver Epoxy Armrest , Gaslift for Seat height adjustment , Standard 5-prong Nylon Base, With Fabric Including necessary hardware completed as per approved design, make and Architect's instructions. ( Basic rate Rs 22000/- per no)
Sofa (Two Seater)- Providing AND Supplying sofa seat made out of 2"X2" ply wood framing with 4" Thk. Foam for seat AND 3" foam back covered with fully up holster.
SIDE Table Corner table made up of 18 mm thick wooden (PLB) with PVC lipping on all edges with 12mm toughened glass fixed with SS studs, SS Finish Stand complete as per drawings and details. Size 600 x 600 x 450mm height
Item Description
Reception Table : 1200mm X 750 mm X 750mm Customer care Table- Providing AND fixing table as described below: Work top to be made out of 25mm particle board finish with pre laminate of approved shade and make with bottom finished with backer laminate. All edges shall be provided with machine pressed 2mmthick PVC edge band. The work surface shall be provided with 60mm dia grommet hole and with cable raceway below top. There shall be CRCA made electrical panel in intermediate legs for wire carrying. Metal Powder coated leg of 50mm X 50mm cross section and of 2mm thickness. Powder coating should be of 60-80 Microns. Front Modesty- Metal perforated modesty mounted with brackets, it should have 50mm gap from the floor level. Rate is inclusive of Keyboard tray of Inoffit make .CPU trolley M.S. Powder coated with castors complete as per detailed technical specifications and drawing.
CABIN Table 2000mm X 900 mm X 750mm with Side combo storage 900mm X 450mm X 750mm HT Cubical Table with side combo storage- Providing AND fixing table as described below: Work top to be made out of 25mm particle board finish with pre laminate of approved shade and make with bottom finished with backer laminate. All edges shall be provided with machine pressed 2mmthick PVC edge band. The work surface shall be provided with 450mm Aluminum powder coated access flap and with cable dump below top. There shall be CRCA made power pole to carry wires from floor to access flap. Metal Powder coated leg of 50X50mm cross section and of 2mm thickness. Powder coating should be of 60-80 Microns. Front Modesty- Metal perforated modesty mounted with brackets, it should have 260mm gap from the floor level. Side combo storage of size 900X450X750mm HT shall be made up of 18 mm thick prelaminated particle board with three drawers and openable shutters as per drawings. All edges to be finished with PVC edge band . Rate is inclusive of provision of key lock, locking strip and multi – drawer lock, brackets for box-file pedestals. Rate is inclusive of metabox channels/ telescopic channel of ebco make or equivalent for supporting drawer. Rate is inclusive of Keyboard tray of Inoffit make . CPU trolley M.S. Powder coated with castors complete as per detailed technical specifications and drawing.
CABIN Table 1500mm X 750 mm X 750mm with Side combo storage 900mm X 450mm X 750mm HT Cubical Table with side combo storage- Providing AND fixing table as described below: Work top to be made out of 25mm particle board finish with pre laminate of approved shade and make with bottom finished with backer laminate. All edges shall be provided with machine pressed 2mmthick PVC edge band. The work surface shall be provided with 450mm Aluminum powder coated access flap and with cable dump below top. There shall be CRCA made power pole to carry wires from floor to access flap. Metal Powder coated leg of 50X50mm cross section and of 2mm thickness. Powder coating should be of 60-80 Microns. Front Modesty- Metal perforated modesty mounted with brackets, it should have 260mm gap from the floor level. Side combo storage of size 900X450X750mm HT shall be made up of 18 mm thick prelaminated particle board with three drawers and openable shutters as per drawings. All edges to be finished with PVC edge band . Rate is inclusive of provision of key lock, locking strip and multi – drawer lock, brackets for box-file pedestals. Rate is inclusive of metabox channels/ telescopic channel of ebco make or equivalent for supporting drawer. Rate is inclusive of Keyboard tray of Inoffit make . CPU trolley M.S. Powder coated with castors complete as per detailed technical specifications and drawing.
CABIN Table 1350mm X 750 mm X 750mm with Side combo storage 900mm X 450mm X 750mm HT Cubical Table with side combo storage- Providing AND fixing table as described below: Work top to be made out of 25mm particle board finish with pre laminate of approved shade and make with bottom finished with backer laminate. All edges shall be provided with machine pressed 2mmthick PVC edge band. The work surface shall be provided with 450mm Aluminum powder coated access flap and with cable dump below top. There shall be CRCA made power pole to carry wires from floor to access flap. Metal Powder coated leg of 50X50mm cross section and of 2mm thickness. Powder coating should be of 60-80 Microns. Front Modesty- Metal perforated modesty mounted with brackets, it should have 260mm gap from the floor level. Side combo storage of size 900X450X750mm HT shall be made up of 18 mm thick prelaminated particle board with three drawers and openable shutters as per drawings. All edges to be finished with PVC edge band . Rate is inclusive of provision of key lock, locking strip and multi – drawer lock, brackets for box-file pedestals. Rate is inclusive of metabox channels/ telescopic channel of ebco make or equivalent for supporting drawer. Rate is inclusive of Keyboard tray of Inoffit make . CPU trolley M.S. Powder coated with castors complete as per detailed technical specifications and drawing.
Both Side Laminate Finish Solid Flush Door Providing AND fixing 35mm.th. Flush Door Solid Double Core type Both Face water proof Commarcial/Marin Ply AND 1.0 mm th.laminate shall be pasted on both side with adhesives as specified by the manufacturers. The laminate shall be as per approved shade AND texture, of make incl. Sal wood frames of finished size 12cm x 7cm.incl. S.S. Hinges ,Aldrop/lock,Tower Bolt with nessary screws AND Anodized aluminum fixtures AND fastenings as per Drawing, Approve by Architect
Laminate Finish Panelling Providing AND Fixing wall panelling made from 50mm x 25mm x 1.2mm aluminium framework at 600 mm x 600mm C/C both vertically AND horizontally covered with 12mm thick commercial plywood (IS:303 ) grade with 1.0 mm thick laminate of approved shade finished with groove pattern and design completed as per drawing and details instruction of engineer-in charge and consultant, as per the sample approved by the Architect. Soft Board with White Board Panel Providing and fixing Soft Board Panel over existing partition / wall with 12mm marine ply backing and 12mm thick soft board ( Cellotex- VOC FREE) with Gripper System. Edges of the soft board to be finished with 0.8mm laminate to get better finish of corners as directed by the Architect. Consider Basic Price of fabric Rs. 500/Rmt excluding tax, delivery on site and wastage.
PVC FLUTTED PANELLING: P/F of 12 mm PVC wall paneling over Existing tile/ plastered surface with high quality PVC panel complete with all fittings like cleats nails screw etc. The rates inclusive wastage, labour and other necessary fittings complete in all Respect Rate Shall be Including Providing AND Installation 50x50x1.5 mm Allu. Framing, back Side Cement Sheet For PVC Panelling Support , Hardware AND All Required Adhesive Material as per Architect/Grimco Manager Instruction. .Rate Shall Be Consider All Floor AND Work Shall be Execute as per Architect Grimco Manager Instruction.
MD CABIN TOILET AND CHAIRMAN CABIN TOILET AND CONFERENCE ROOM TOILET Providing and construction of Toilet including water proofing work, fixing of approved tiles and all fixture, accessories and plumbing work and proper slope and level in flooring wall dado tiles up to ceiling level as per pattern design including all fixture and fitting as per design and Architect's instructions. (as per below ) (A) Vitrified / Rectified tiles matt finish Flooring 600mm x 600mm with Epoxy grouting ( Basic rate 650/sq mt) (B) Vitrified/ Rectified tiles dado 600mm x 600mm with Epoxy grouting ( Basic rate 650/sq mt) (C) Urinal with Sensor Urinal Aquisense Sensor Concealed type Flushing Valve , wall mount EWC with metro pole flush or Concealed tank tank, Wash basin fixture, both side mirror polish finish granite partition for urinal (F) Plumbing fittings - Bib cock, Bottle trap, Angle stop cock, Flush Cock, two-way bib cock, head faucet, auto sensor pillar cock , Robe Hook, Paper holder, Tissue paper holder, Hand dryer, Auto soap dispenser etc. (F) Granite Wash cabin counter - 600mmm depth granite counter with kota stone base support with 300 mm wide vertical 18mm thick granite band, under counter wash basin. auto sensor pillar cock, Angle Stop cock, wast coupling, bottle trap etc. complete (G) Mirror Size : 600mm x 900mm / as per site location requirement (H) Waterproofing, Sunk Filling with Floor PCC as per site required of toilet with tapecrete as per company manufacturer's specifications
LADIES AND GENTS COMMON TOILET (WITH FLOORING, ASSESORIES, VENTILATION, DOOR) Providing and construction of Toilet including water proofing work, fixing of approved tiles and all fixture, accessories and plumbing work and proper slope and level in flooring wall dado tiles up to ceiling level as per pattern design including all fixture and fitting as per design and Architect's instructions. (as per below ) (A) Vitrified / Rectified tiles matt finish Flooring 600mm x 600mm with Epoxy grouting ( Basic rate 350/sq mt) (B) Vitrified/ Rectified tiles dado 600mm x 600mm with Epoxy grouting ( Basic rate 350/sq mt) (C) Urinal Aquisense Sensor Concealed type Flushing Valve , wall mount EWC with metro pole flush or Concealed tank tank, Wash basin fixture, both side mirror polish finish granite partition for urinal (F) Plumbing fittings - Bib cock, Bottle trap, Angle stop cock, Flush Cock, two-way bib cock, head faucet, auto sensor pillar cock , Robe Hook, Paper holder, Tissue paper holder, Hand dryer, Auto soap dispenser etc. (F) Granite Wash cabin counter - 600mmm depth granite counter with kota stone base support with 300 mm wide vertical 18mm thick granite band, under counter wash basin. auto sensor pillar cock, Angle Stop cock, wast coupling, bottle trap etc. complete (G) Mirror Size : 600mm x 900mm / as per site location requirement (H) Waterproofing, Sunk Filling with Floor PCC as per site required of toilet with tapecrete as per company manufacturer's specifications
supplying, installing, testing and commissioning of Stainless Steel Water Cooler (SS-304) with storage capacity 150–200 Litres and cooling capacity 150–200 LPH, complete with heavy-duty hermetically sealed compressor, copper condenser AND evaporator coil, PUF insulated body, SS-304 inner/outer tank, 2–3 Nos. chrome-plated water taps, inbuilt thermostat control, drain tray with outlet, necessary plumbing fittings, inlet/outlet connections, electrical wiring/MCB, earthing and all accessories required for proper functioning, complete in all respects as directed by Engineer-In-Charge."
Providing and fixing meeting table top 12mm glass with SS stand DIA-900mm
Providing AND erecting weather proof, dust AND vermin proof, floor mounted front operated indoor type cubical panel board necessary IP-42 and above protection as per approval from engineer incharge made from 14 SWG thick CRC M.S. sheet for outer body AND doors, 16 SWG thick CRC M.S.sheet for internal partitions with necessary accesories , supporting angles/ flats channel including cutting, bending, drilling, welding, riveting with internal partitions AND cable alley as per requirements AND instruction of engineer-in-charge with erection of supplied switch gears, BUSBARS, suitable size of inter connecting PVC copper wire / copper-aluminium strips, rubber grommets, rib, bakelite control fuses/MCB for measuring instruments, earth bus AND earth bolts, foundation flange - bolts-base Plates, sufficient nos. of hinged doors, handles with locking arrangement and rubber gasket,heavy duty end terminal connection,danger notice board,necessary ventilation,earthing strip complete. The Panel shall be painted with epoxy powder coating. (The rates excludes the cost of switchgears, bus bars, inter connecting mains AND Copper Aluminium strips, meters, Fuses etc. The dimension shall be measured excluding base beams) The panel shall be supplied with following approved manufacturers with following size.(B) The standard companies switch gear shall be used and only manufacturers at CPRI approved factory (i) with 350mm depth
Providing and erecting Approved make Three pole moulded case circuit breaker having breaking capacity/strength ICU of 35 K.A. and above at 415 V. having Normal current rating 200A.with variable Thermal AND magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections, spreader tinned copper AND complete erected in existing 16 G.M.S. housing.ICSEQUAL TO100PERCENTAGE of ICU only Cat III
Providing and erecting Approved make Earth fault Relay suitable to mount with inter connection suitable to following size of moulded case circuit breaker having CT ratio AND MCCB rating as following along with shunt trip 220V AC. with all internal connections AND complete erected in existing M.S.housing.. (2) 125 A -200 A , CT Ratio 1/200
Providing and erecting following additional parts for panel mounting MCCBs (A)Extended operating rotary handle with pad lock with three position trip,off,on suitable for 25A to 250 A panel mounting cat-III
Supplying and erecting triple pole AND neutral 440V/ 500V panel mounting Aluminium Busbars with four equal Nos. of bus having current density not more than 0.8 Amp. / sq.mm (Rated current / cross section area) duly wrapped with colour insulating tape for phase sequence of following current carrying capacity, erected with necessary bus bar supports /insulators, main cable socket to each busbar,erected in existing cubical panel with necessary connections.(B) Suitable for 200 Amp. Capacity
Providing AND erecting 240 V MCB double pole switch for motor AND inductive load (C Curve) having 10 KA breaking capacity AND confirms to IS : 8828 in existing box having following capacity (A) 6 to 32 Amp. Cat.III
Supplying AND erecting approved make IP 55 grade Company fabricated Timer Panel of following capacity for switch On-Off street lights on time scheduling basis made from 16G CRCA sheet duly epoxy power painted inside and outside with hinged doors and locking arrangement consisting of suitable size of 4 Pole MCB and 4 pole contactor (cat-III)with analog time switch, auto manual switch of same make and suitable input and output Bakelite terminals and with door earthing approved by Engineer in charge. (A) 32 Amp
Supplying AND erecting bank of all polypropylene condenser (APP type) with standard capacity of 2,3,5,7, 10,12.5 AND 15 KVAR units of P.F. correction for operation on 3 phase 50 c/s, 400 /440V (+ / - 10PERCENTAGE ) with externally discharging resistance, earthing terminal AND built on angle iron of channel iron frame work and provided with terminal cover box. Complete erected on provided iron bracket or on floor duly tested by license.
Providing and erecting multifunctional meter suitable for application of Power monitoring and showing measurement of following Voltage, Frequency, Apparent energy, Apparent power, Active and reactive energy, Active and reactive power, Average voltage Vavg, Peak demand power PM, QM, SM, Demand power P, Q, S, Apparent power S, S1, S2, S3, Unbalance current, Power factor and displacement PF (signed, four quadrant), Calculated neutral current, Active, reactive, apparent energy (signed, four quadrant), Active power P, P1, P2, P3, Voltage U21, U32, U13, V1, V2, V3, Phase currents, Average current Iag, Peak demand currents, Reactive power Q, Q1, Q2, Q3, Demand current I1, I2, I3, [Us] rated supply voltage 40...300 V AC 45...65 Hz, 40...300 V DC, Network frequency 50 Hz, Type of network 3P, Display type 7 segments LED, Display colour Red, Messages display capacity 3 fields of 4 characters, Display digits 12 digit(s) - 14.2 mm in height
Supplying and erecting approved make panel mounting type Digital Voltmeter having 3 digits LED display, 0 to 750 AC Volts range erected on existing panel board with all connection, wiring etc .with manufacturers calibration certificate.
Supplying and erecting approved make Analog type moving iron C.T operated Ammeter A C Current suitable slide in scale 0- 400 Amp. with 3 Nos. of Current Transformer erected on panel board with connections.
Providing AND erecting L.T. Current Transformer with bar primary 50/5 to 1000/5 ratio 15 VA burden erected in existing CRCA box duly secured with insulating materials connected to the meter
Supplying AND erecting approved make Power Factor Meter 150mm dia flush/projection type/ balanced AND unbalanced load to work with appropriately provided CT’s 100/5A to 400/5A ratio AND other accessories complete erected in M.S. box AND connected to the circuit by means of PVC copper Core leads.
Supplying and erecting approved make suitable panel indicator LED type lamp, lens cover, complete erected with necessary connections.
Providing , erecting , fabricating the M.S. structure as per requirement on site incorporating proper size of M.S. angles,square,round, flats, bars, channels, sections complete with cutting, welding, grinding AND finishing duly painted with one coat of red oxide with erection on site as per direction of engineer in charge with necessary grouting, cementing, plastering AND finishing complete.
Providing AND erecting capacitor duty contactor 3 phase, 415 V with proper connection for following rating:(A) 10 KVAR
providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed copper conductor with heat resistant PVC insulated conforms to IS 694, IEC - 227 erected in existing pipe of following size (Specifically for control panel, relays, power switchgears, motor starters AND control wiring) with required size of copper lugs, nuts and bolts if required.(b) One wire 1.50 sq. mm
(c) One wire 2.50 sq. mm
(e) One wire 6.00 sq. mm
(f) One wire 10.00 sq. mm
Supplying AND erecting carbon dioxide (CO2) fire extinguisher user of following capacity with necessary clamps made from 50 x 6 mm M.S. Flat with nut AND bolts grouted in wall complete. [A] For 4.5 Kg Capacity
Supplying AND erecting D.C.P. type fire extinguisher for following capacity cartridge type with gun metal cap 150 gram CO2 gas cartridge, powder and brackets confirming to IS 2171 1985 and complete erected with necessary clamps made from 50 x 6 mm M S Flat with nuts and bolts grouted in wall [A] For 5 Kg Capacity
Supplying rubber matting of following thickness as per IS:15652/IEC 61111 (a)3mm
Supplying stand first AID box with antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-aid) adhesive tape for medicinal user, Scissors, anti-septic solution (Savlon or similar) etc. (All above contents shall be of standard makes)
Supplying FIRE bucket round bottom of 9 litres capacity made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and Red out side with FIRE mark, filled with dry-sand and kept on existing stand provided or hung on wall hook.
Wall hook 22 to 25 cms. projection for keeping fire buckets made out of 15 mm dia. M.S rod grouted in wall to a depth of minimum 15 cms.
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables. (F) 3 1/2 core 120 Sq. mm ( 70 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables. (B) 4 core 16 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables.(A) 4 core 10 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand / Solid Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables.(C) 4 core 6 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand / Solid Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables.(B) 4 core 4 Sq. mm
providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed copper conductor with heat resistant PVC insulated conforms to IS 694, IEC - 227 erected in existing pipe of following size (Specifically for control panel, relays, power switchgears, motor starters AND control wiring) with required size of copper lugs, nuts and bolts if required.(g) One wire 16.00 sq. mm
Providing and, fixing heavy duty flange type brass double compression type cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. (E) 3 AND 1/2 core 120 Sq. mm
Item Description
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables.(A) 2 to 4 core 2.5 / 4 Sq. mm
(B) 2 to 4 core 6 Sq. mm
(C) 2 to 4 core 10 Sq. mm
(D) 2 to 4 core 16 Sq. mm
Solder less crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool AND connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (E) 70 Sq.mm.
(G) 120 Sq.mm.
Solder less crimping type Copper lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool AND connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (A) 1.5/2.5 to 6 Sq.mm
(B) 10 Sq.mm
(C) 16 Sq.mm.
Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 AND 3, IEC 61439-1 AND 3 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used) suitable for (A) single phase incoming and horizontal single phase outgoing (b) sheet steel double door (IP-43) (ii)6 way
(iii)8 way
(B) three phase incoming and single phase horizontal type outgoing Per phase isolation type (PPI) (b) sheet steel double door (iii)8 way
(iv)12 way
providing and erecting Approved make RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and suitable for operation on single phase 240 V,50Hz. having characteristic of quick action AND tripping with all advance feature AND do not incorporate any electronic component. for following Max. rating erected as directed (i) 25 Amps.DP Cat. III
(ii) 40Amps. DP Cat. III
(iii) 63 Amps. DP Cat. III
Providing AND erecting 415 V MCB Four Pole for Motor AND Inductive Load (C Curve) having 10KA breaking capacity AND confirms to IS :8828 in existing box having following capacity (b)40 Amp.
Providing AND erecting 415 V MCB three Pole for Motor AND Inductive Load (C Curve) having 10KA breaking capacity AND confirms to IS :8828 in existing box having following capacity (a) 6 to 32 Amp.
providing and erecting Miniature circuit breaker single pole 6A to 25A suitable to operate on 240 V A.C. system and having breaking capacity 10 KA to be erected in existing box. confirming to IS 8828/1996 with ISI Mark Cat.III
Plastic enclosure fitted with DIN rail suitable for incorporating Three /Four nos. MCB
Sheets steel powder coated enclosure suitable for incorporating One/Two nos. MCB.
Supplying AND erecting 20 Amp 10 KA ‘C Curve’ single pole MCB with 20 Amp. Plug socket, company fabricated powder coated sheet steel enclosure erected as directed with connection. [A] Metal Clad Socket with metal clad top Cat.III
Supplying AND erecting approved make RCCB + MCB (Electro magnetic type only) working on residual current device having 10 KA short circuit breaking capacity and 30 mAmp. Sensitivity AND 30 mili sec. tripping time conforming to IS 12640 test knob facility trip free mechanism operating for rated leakage at nominal ten volt, complete erected including all materials lugs screws etc. completed.[f] 63A, 4 pole Three Phase Cat. II
Supplying AND erecting earth pit of minimum bore dia.150mm size approved make Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free hot dipped G.I.Pipes having Outer pipe dia of 50mm having 80-200 Micron galvanising, Inner pipe dia of 25 mm having 200-250 Micron galvanising, connection terminal dia of 12mm with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for following type of applications with chamber and heavy duty cover. (A)(approved make OEM has to submit test certificate including value of earth resistance of installation duly stamped and signed by agency and officer Incharge has to ensure the value of earthing resistane mentioned in test Certificate) AND having back filling compound of (B) Inner chemical (CCM Compound)- Resistivity:- 0.2 ohm / meter testing as per IEC 62561-2017, Voltage drop:- < 1 volt at no load AND dry form, Sulphar content:- <2PERCENTAGE (C) Back fill Compound :- Earthing compound should be capable to retain moisture for long time Necessary test report must be submitted by Agency. (c) For Electrical Installation covering Transformer Neutrals, Lightning arrester Earthing, A.C.Plant AND Sensitive Computer System(like Automation, SCADA) i.e independent Earthing in normal soil. Length of Pipe : 3.00 mtrs Back filling Compound :2 nos Bags of 25 Kg.
Providing and erecting required size HOT deep Galvanised iron strip for earthing of H.T. , OCB/ ACB/ Transformer LT panel board, Motors etc. using proper clamp.
providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed copper conductor with heat resistant PVC insulated conforms to IS 694, IEC - 227 erected in existing pipe of following size (Specifically for control panel, relays, power switchgears, motor starters AND control wiring) with required size of copper lugs, nuts and bolts if required. (e) One wire 6.00 sq. mm
providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed copper conductor with heat resistant PVC insulated conforms to IS 694, IEC - 227 erected in existing pipe of following size (Specifically for control panel, relays, power switchgears, motor starters AND control wiring) with required size of copper lugs, nuts and bolts if required. (f) One wire 10.00 sq. mm
FLOORING RACEWAY AND CABLE TRAY Supply AND installation of readymade Hotdip G.I./ Powder Coated Flooring Raceway AND Junction Box, specification AND instruction of Engineer-in-charge including all materials AND hardware. 100 mm x 38 mm x 1.6 mm thick 2 Compartment flooring raceway
300 mm x 38 mm x 1.6 mm thick 3 compartment flooring raceway
350mm x 350 mm Floor Junction Box With SS Junction Plate.
150mm x 150 mm Floor Junction Box With SS Junction Plate.
Providing and fixing approved make Perforated C type cable tray. Made from sheet steel. The cable tray should be single or double bended as per required and as per IS 2062/1079 and shall be coated with hot dip galvanizing as per IS 2629/4759. with max 17.5PERCENTAGE perforation with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erection with necessary support( included) as per Specification and as per instruction of engineer in charge..(2) 100 X 50 X 1.6 mm Thick
(4) 200 X 50 X 1.6 mm Thick
Point wiring for Light / Bell with 2-1.5 sq.mm AND earth wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr length , in below type of pipe erected with 6A Modular type switch / bell push AND accessories and earth continuity of following type, erected on PVC / Metallic/Wooden box, single mounting base frame covered with textured/metallic/white front plate modules erected on / in wall / ceiling as per pipe erected, with necessary Lamp holder/ceiling rose / H.D.Connector as directed. (f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete
Point wiring for Tissino / Modular secondary light point with 2-1.5 sq.mm AND earth wire of 1.5 sq.mm (green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires, in below type of pipe to be erected complete with earth continuity and necessary connection with primary light with accessories erected on Metal / PVC / wooden box covered with 3 mm thick PC(Polycarbonate) / Acrylic sheet for open / concealed wiring. with necessary Lamp holder / ceiling rose / H.D.Connector as directed. Note:- Maximum up to 6 mtrs length, excess will be considered as Mains for Secondary Point. (f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete
Point wiring for FAN with 2-1.5 sq.mm AND earth wire of 1.5 sq.mm (Green) both are of .ISI marked 1.1 KV Grade FRLS PVC insulated multi strand copper wires up to 10 mtr length, in below type of pipe erected with 6A Modular type switch and hum free EME step type electronic fan regulator mounted and accessories with earth continuity of following type erected on PVC / Metallic/Wooden box, single mounting base frame covered with textured/metallic/white front plate modules erected on / in wall / ceiling as per pipe erected. with necessary ceiling rose / H.D.Connector as directed. (f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete Cat. III
Point wiring for on board Looped Plug with 6A Modular type switch AND 5 pin socket erected on PVC / Metallic/Wooden box, single mounting base frame covered with textured / metallic/white front plate modules erected on / in wall / ceiling with following type accessories Cat. III
Point wiring for Individual Plug with AND earth wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr length, in below type of pipe erected complete with Modular type switch AND 5 pin Plug erected on PVC / Metallic/Wooden box covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following type of accessories . [I] For 6A Plug and 6 a switch with 2-1.5 sq.mm Cu. Wire from nearby switchboard/mcb db board (f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete
Point wiring for Individual Plug with AND earth wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr length, in below type of pipe erected complete with Modular type switch AND 5 pin Plug erected on PVC / Metallic/Wooden box covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following type of accessories . [II] For 16A Plug and 16 amp switch with 2-2.5 sq.mm Cu. Wire from mcb db board. (f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete
Providing AND erecting Switch board for Computer or electric apparatus consisting of following modular type accessories mounted with PVC / Metallic concealed/open box with single mounting base frame covered with textured/metallic /white front plate,modules erected with necessary connections as directed 1 no. 6A/16A universal plug-switch combined. 3 nos. 6A Switch 3 nos. 6A 5 pin Plug For Modular Type Accessories Cat. III
Point wiring for Individual Plug with AND earth wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr length, in below type of pipe erected complete with Modular type switch AND 5 pin Plug erected on PVC / Metallic/Wooden box covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following type of accessories . [I] For 6A Plug and 6 a switch with 2-1.5 sq.mm Cu. Wire from nearby switchboard/mcb db board (f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete
Point wiring for Individual Plug with AND earth wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr length, in below type of pipe erected complete with Modular type switch AND 5 pin Plug erected on PVC / Metallic/Wooden box covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following type of accessories . [II] For 16A Plug and 16 amp switch with 2-2.5 sq.mm Cu. Wire from mcb db board. (f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete
Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size (A) With medium class Rigid PVC pipe and accessories (a) 2 wire 1.5 sq. mm
Item Description
Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size (A) With medium class Rigid PVC pipe and accessories (b) 2 wire 2.5 sq. mm
providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected in / on wall / ceiling with 2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size (A) with medium class Rigid PVC pipe and accessories (a) 2 wire 4 sq. mm
(iii) 18-20 Watts, Surge - 2KV,IP-20, conventional 4 feet
(D) LED Strip Light (ii) Minimum 7.2W -240 LED per meter,(2 wire, IP-65) with non integral suitable Driver complete Cat-lll
(I) Adjustable spot light with COB led having aluminium reflector of following wattage (ii) 12 Watts
LIGHT FIXTURE Supply, Installation, testing AND commissioning of Light fixture in False Ceiling or on wall or bellow slab, Exhaust fan as per Drawing AND as per instruction of engineer-in-charge. All fixtures to be considered with required size of drivers AND Required Hardware etc. 36W 1200mm LED Linear Hanging light with Required Jointer, Elbow AND accessories etc.
17.2 mm LED Profile Light With Requiredd Driver etc.
600MM Dia Round Decorative Light Fxitures Aluminium Profile with Required Hanging Arrangement etc.
Providing AND erecting Approved make Ceiling Fan with double ball bearing ISI mark with Condenser 230 volt A.C.50 Hz 1200 mm sweep complete having 3 blades aluminium body and blade sets having ornamental design shanks , canopy erected with earthing. [ Make shall be approved by Engineer in Charge]
Supply, Installation, testing AND commissioning of Cassette Flase Ceiling Fan Recessed Square Fan With Remote Control For Home And Commercial Use, 360° Air Flow - 600 x 600 mm - White.
Supplying and erecting approved make oscillating type bracket fan A.C. 23OV. 50cy/s 400/450 mm sweep wall mounted with height adjustment and rotary tilting device complete with guard, flexible Core plug top complete erected with lead wires as directed.
Supplying AND erecting approved make low noise decorative exhaust fan having square frame ABS body with inbuilt lowers AND square frame. 200mm with 1350RPM Cat.II
Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceiling erected with necessary PVC fittings AND Junction boxes fixed with adhesive solution AND Clamps with following dia of pipes, in approved manner as directed (c) 32 mm
Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceiling erected with necessary PVC fittings AND Junction boxes fixed with adhesive solution AND Clamps with following dia of pipes, in approved manner as directed (b) 25 mm
Supplying and laying UPVC cable trunking system comprising unplasticised polyvinyl, chloride rigid material with ignition free and flame proof confirming BS with necessary end caps Internal and external bend, flat bends, coupler, tee etc..All necessary accessories and measuring of following sizes (2) 100 mm x 50 mm trunking
Supplying and laying UPVC cable trunking system comprising unplasticised polyvinyl, chloride rigid material with ignition free and flame proof confirming BS with necessary end caps Internal and external bend, flat bends, coupler, tee etc..All necessary accessories and measuring of following sizes (3) 50 mm x 50 mm trunking
Supplying and erecting approved make online Un-interruptible Power Supply system comprising flat cum-boost charger with IGBT base rectifier AND Inverter AND sealed maintenance free SMF batteries. The charger having operating capacity for input 160-270V AC AND inverter having output 230V,50 Hz Ac with 0.8 load power factor with battery, over/under voltage output with over load AND short circuit protection equipment. The system housed in CRC sheet duly powder coated paint with following power backup.with MS painted batteries stand, 10PERCENTAGE Overload capacity for momentary load. (K) 30 KVA 3 - phase with 1Hr Backup
Supplying AND erecting approved make LAN cable of following size in existing pipe as per direction [C] CAT - 6
SITC of Face Plate - Single (Keystone Jack,square) [Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
SITC of Face Plate - Dual (Keystone Jack,square) [Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
SITC of Jack Cat 6 Keystone UTP [Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
SITC of Patch Panel Cat 6 UTP Keystone Type- 24 Port-Fully Loaded [Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
SITC of CAT6 UTP 24AWG PATCH CORD:1M,Plug 30U' Snag less [Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
SITC of CAT6 UTP 24AWG PATCH CORD:2M,Plug 30U' Snag less [Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
SITC of 24U Wall Mount Rack for Mounting devices with all required accessories. There should be 15amp multiplug points power strips in each rack installed on both sides in the rear side of the rack, This should have 2 fans exhaust on the top, with metal perforated door on both side; teh rear side door should be double door. This should also have adequate cable managers alognwith tagging on jack panels itself. The tagging has to be printed (and should not be handwritten) with rack installation AND dressing ( Incl. Equipment Tray, PDU (Power strip) as per Requirement.
Providing AND erecting ` Distribution (MDF) indoor type, back mounted frame as per DoT standard approved with krone strips (d) Suitable for 100 pair
Supplying AND erecting approved make Telephone Cable electrolytic copper conductor PE insulation twisted in two pairs, AND wrapped with FRLS PVC tape AND sheathed with FRLS PVC or HFFR outer Jacket suitable for telephone wiring AND confirming to C-DOT erected in existing pipe. of following size of conductors AND nos.of pairs. With necessary connections. (b) Armoured [Jelly Filled] (4) One Hundred Pairs
SITC of Roddent System As Below Details ( FOR SERVER ROOM ) Master Console in Metal + 8 Transducers Protects Enclosed Area of approx. 600 Sq. Ft. in a plain area. Each Transducer covers 300 Sq Ft. in normal floor, 150 Sq Ft in False ceiling and flooring required of cables supplied Stand AND Bracket to mount the controller
Fire Alarm System Supply, Installation, Testing AND Commisioning of microprocessor based Intelligent addresable 1 loop Fire Alarm Control Panel with each loop and should have a capacity of detector and module combination in Two loop, 4 x 20 character backlit LCD display, Form C contacts for alarm and trouble, Form A for supervisory, Electronic addressing with automatic device mapping, The panel should have a front panel, for logic programming and editing capacibility from the panel and also should have provision for programming from the PC/laptop, Optional Ethernet port for diagnostics, programming and avariety of system reports, Supports up to eight serial annunciators, (LCD, LED-only, and graphic interface), Two-level maintenance alert reporting, Pre-alarm and alarm verification by point, Alarm ON command manually activates alarm condition, Four access levels, sufficient number of programmable relay controls for controlling AHUs, pressurization fans, escalators, monitoring of fire sprinklers and fire hydrant pump, 240 volts AC power supply, Optional earthquake hardening: seismic Importance Factor 1.5, panel. Approved by UL AND FM
Supply, installation, connecting, testing and commissioning of Modbus/BACNET card for BMS integration
Supply, Installation, Testing AND Commisioning of Battery Backup for FACP min 4 hours
Supply, Installation, Testing AND Commisioning of addressable microprocessor based photo thermal multi criteria smoke cum heat detector with mounting based , Integrates optical smoke with rate-of-rise heat sensing, Wide 0.53 to 3.94 PERCENTAGE /ft. (1.7 to 12.35 PERCENTAGE /m) smoke obscuration, Two levels of environmental compensation, Two levels of dirty detector warning, Twenty pre-alarm settings, Five sensitivity settings, Electronic addressing, Environmental compensation, Automatic day/night sensitivity adjustment, Bicolor (green/red) status LED. Approved by UL/ FM
Supply, Installation, Testing AND Commisioning of Flame Detector and with mounting based , Automatic device mapping, Sensor Markings Provide Easy Testing Identification, Non-volatile memory, Electronic addressing, Bicolor (green/red) status LED. Approved by UL/FM
Supply, Installation, Testing AND Commisioning of addressabale type Fault isolator for isolating shorted, dewired and loose circuits between two successive fault isolators with automatics resetting arrangement (base model) Approved by UL/FM
Supply, Installation, Testing AND Commisioning of addressable Manual Glass Break station, Intelligent device with integral microprocessor, Electronic Addressing with Non-volatile memory, Automatic device mapping, Diagnostic LEDs, Designed for high ambient temperature operation. Approved by UL/FM
Supply, Installation, Testing AND Commisioning of control relay module a Form “C” dry relay contact to control external appliances such as door closers, fans, dampers etc. This device does not provide supervision of the state of the relay contact. Instead, the on-board microprocessor ensures that the relay is in the proper ON/OFF state. Upon command from the loop controller, the relay activates the normally open or normally-closed contact. Approved by UL/FM
Supply, Installation, Testing AND Commisioning of Response Indicator
Supply installation of ISI Marked 2 core x 1.5 mm2, Multistrand Copper, FRLS Armoured cable, RED in Colour, laid on surface with GI saddle-spacers every 0.3 meters. Complete with GI Junction Box, lugs, cable compression glands, cable tags and Ferruling.
CCTV SYSTEM Supply,installation ,testing AND Commissioning of Vandal Proof 2 MP 2.8 mm Lens Network IR Dome Camera 1/2.8" Progressive Scan CMOS; H.265+/H.265/H.264+/H.264/MJPEG; Color: 0.028 Lux (F2.0, AGC ON), 0 lux with IR; 25fps/30fps(1920×1080); VCA functions; 3 streams; 3D DNR; BLC/HLC; ICR; EXIR, up to 30m; DC12VANDPoE
Supply,installation ,testing AND Commissioning of Vandal Proof 2 MP 2.8 mm Lens Network IR Bullet Camera 1/2.8" Progressive Scan CMOS; H.265+/H.265/H.264+/H.264/MJPEG; Color: 0.028 Lux (F2.0, AGC ON), 0 lux with IR; 25fps/30fps(1920×1080); VCA functions; 3 streams; 3D DNR; BLC/HLC; ICR; EXIR, up to 30m; DC12VANDPoE
SITC of 8 x 10/100/1000BASE-T PoE ports 2 x Gigabit SFP ports Advanced L2 switching and security features L2+ Static Routing Optional “standard mode” or “surveillance mode” management user interface 65W PoE budget [Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
Supply,installation ,testing AND Commissioning of Up to 16 channel IP camera input, Along with Dual Network Interface, Max 200 Mbps incoming bandwidth, Smart H.265+/H.265/Smart H.264+/H.264/MJPEG, Up to 12MP resolution preview and playback, 4 USB(2 USB3.0, 2USB2.0), 1 HDMI / 1 VGA simultaneous video output, Support Multi-brand network cameras, Support RAID 0/1/5/10
Item Description
Supply,installation ,testing AND Commissioning of 4 TB Enterprise Surveillance HDD
Supply,installation ,testing AND Commissioning of 9 U CCTV Rack Along with Required accessories
Supply, Installation, Testing and Commissioning of RJ 45 Connector
Supply, Installation, Testing and Commissioning of LCD Monitor 19"
Supply, Installation Testing AND Commissioning 15 Mtr. HDMI Interface Cable as per the detailed Specifications supports transmission of 4K Signals as per the detailed Specifications
SITC of 360W ALL-IN-ONE AMPLIFIER [Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
Providing and erecting cordless microphone with UHF Diversity handheld wireless microphone/caller wireless complete with receiver and transmitter unit,Cardiod ,polar pattern,dynamic microphone,LCD display for battery and frequency status and information ,32 preset channels,with compatible groups of 8 channels,14 hrs.battery life,frequency response 80Hz to 18KHz.,RF sensitivity 55 dB,dynamic range >95 dB and receiver having 32 channels,S/N ratio>100 dBA,Dynamic range>95 dB,distortion<1PERCENTAGE [[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
SITC of Ceiling loudspeaker 6W, metal with clamp [Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
Volume Control Supports up to 36W, installations on a 3x3 inch electrical mounting box Supply AND Fixing.
Supply AND Lying of Flexible 2 Core 1.5 Sqmm FRLS Cable along with PVC Conduit AND Required Accessories.
Providing AND erecting approved make Fingerprint and card based Premium Door Controller with LCD and Keypad having following features. (A) Optical Fingerprint and Card based Reader (Card personality Module not included] (B) Dot-Matrix LCD and Touch sense Keypad (C) Built-In interfaces like door lock, door sense, exit Reader, Exit switch, Ethernet RS485, Aux Input AND Aux Output Port (D) 5000 Events, Access Control, Time Attendance, Tamper Detection (E) 4 LEDS and Buzzer
Providing AND erecting approved make Card Reader having following features. [A] Wiegand / RS232 Interface (B) Power supply from COSEC Door controller or through Separate Adaptor (C) Compatible with any COSEC Door controllers (D) 4 LEDs (Status, Alarm, Allowed and Denied) and Buzzer (E) Tamper Detection
Providing AND erecting approved make Card Personality Module (CPM) having following features (A) EM proximity Card Reader Module [Low frequency] (B) Compatible with any COSEC Door Controllers and COSEC Reader CA (C) Supports EM Proximity Card
Providing AND erecting approved make Panel Controller for Multiple Door Controllers having following feature (A) Controls up to 16 Door Conditioners (B) Ethernet RS485, USB,Aux Input and Aux Output Port (C) 10000 Users Capacity and 100000 Events Storage (D) 32-bit processor, 32 MB RAM and 32MB Flash (E) Compact and Elegant Design
Providing AND erecting approved make Application Software Platform for 500 Users having following features (A) With 100 Users (B) Expandable up to 500 Users with COSEC USER100 (C) Supports up to 16 Door Controllers (D) Basic Access Control, Basic Time Attendance and Enrolment Management (E) Compatible with all COSEC Hardware (F) Add Other COSEC software Modules on requirement.
Power Supply for Access Control Controller along enclosure Box
Fire Suppresion System Supply AND Design of Direct Low Pressure System for Main LT Panel , Cylinder BIS Approved filled with FK-5-1-12 Gas, UL Approved, Suitable for Electrical / Electronic sensitive equipments, Cylinder-deep drawn, Hydrostatic pressure tested,Direct Low Pressure Valve with two outlets, Brass Nickel Plated, Stainless Steel connectors, 360 Degree Rotational Handwheel valve for close / open position, Integrated in Valve main body at the top, Secured with Alen key to avoid misuse, Push In Pnematic Fittings, Valve Inlet M30x 1.5, Valve Outlet G1/8", Diptube Thread M16 x 1.5, Pressure Gauge Thread M10x1, Seal Seat Diameter 63.6mm2, Operating Pressure 15 to 23 Bar, Test Pressure 28 Bar, Operating temperature -20 Degree C to + 65 Degree C, Safety Device : Burst Disc, Approved by Kiva Inspecta AB, Sweden, PI marked, TPED approved, Used Standards for type approvals ISO 17871:2015 in conjunction with EN ISO 10297:2014 EN ISO 14246: 2017-12. Note : Gas Calculation have to consider as per Size of Main LT Panel
Supply AND Fixing of End of Line Adapter 1 Nos, Pressure Switch 1 Nos, Heat Sensing Tube 20 Mtrs, T-Connector 1 Nos, End of Line Plug 1 Nos, Health Monitoring Panel 1 Nos for Fire Suppresion
Installation AND Commissioning of the fire suppression system
Providing and erecting approved make split air-conditioning unit consisting of copper condensing unit with fan motor, hermetically sealed rotary compressor with accessories etc. duly connected separately erected evaporating unit and blower motor with its accessories by means of extra supplied proper insulated copper tubing,drain PVC pipes suitable for ( cost includes powder coated Stand, Eco Friendly green gas charging, 15A plug top AND Remote Control) with necessary core cutting. (2)For ISEER Range (KWH/KWH)(4.0 to 4.49) (c) for 2 ton capacity
Supplying AND installing MS standard type stand mounting for outdoor unit of Split A.C. upto 4 TR capacity erected with necessary hardware materials as directed.
Supplying and erecting insulated pair of soft copper tubing open or concealed including power and control cable,necessary PVC drain pipes for Split AC machine up to 4 TR capacity
Supplying and installing MS angle , powder coated / Painted standard type of wall/floor stand mount for outdoor unit of split AC of following capacity, erected with necessary hardware materials as directed.
(A) 25mm*25mm*3mm thick M.S angle suitable for upto 2 TR. Capacity of ac machine
Supply installation testing commissioning Shielded Shielded Control Cables for VRV System with necessary ISI mark Medium class rigid PVC pipes with necessary accessories with termination in machine and control equipments..(B) 3C X 1.5 Sq mm Shielded Armoured
Existing Furniture Return BYE-BACK (ELECTRICAL WIRING, TABLE, CHAIR AND WOODEN PARTITION)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
01_TB.pdf
02_BOQ.pdf
03_04_INTERIOR CIVIL AND ELECTRIC MAKES LIST.pdf
05_Plan.pdf
06_Plan.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .